Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
7 May 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
22 conditions · 6 needing a document upload
Financial Eligibility Criteria - The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure - VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. (Page-14, Para 10.2, Part-I of GCC April 2022). Attached Performa as per Annexure VIB - in Tender Document).
Electrical Contractor License: The tendering firm must have valid Electrical Contractor's License issued by any State Government in their own name or in the name of the firm, as per IE Rule 1956 clause No. 45 or as amended from time to time. A copy of the license shall be uploaded along with the tender offer failing which the offer shall be summarily rejected. The license must be valid as on the date of opening of the tender. If the license has been expired as on the date of opening of tender, the license renewal documents must be uploaded along with the copy of the old license. The Contractor shall possess valid License throughout the currency of the contract. The contractor shall ensure timely renewal of the license.
27 conditions · 9 needing a document upload
1) The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. 2) The Bid Security shall be deposited either in cash through e-payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. (3) In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days before closing date for submission of bids(ACS-2 Dated 13.12.2022) iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non-submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder. (As per Clause 5, Page -4,5,6 Part I GCC April 2022 with ACS-2 Dated 13.12.2022)
Subject to exemptions provided under para 5(1) (a) of Part-1 (ITT) of GCC April 2022, the tender must be accompanied by a Bid Security as mentioned in tender documents, failing which the tender shall be summarily rejected. (Clause 6 (a) Annex -I, Page-11, Part-I of GCC April 2022)
Note: i) Any firm recognized by Department of Industrial Policy and Promotion (DIPP as 'Startups' shall be exempted from payment of Bid Security subject to submission of Registration Certificate issued by appropriate authority. ii) Labour Cooperative Societies shall submit only 50% of Bid Security shall also additionally submit Registration Certificate. (As per Clause 5 , Page-5, Part-I of GCC April 2022)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
If a tender is accepted on the quoted rates of bidder which is below the advertised tender value, an additional performance security shall be submitted by the bidder as below: (Railway Board Letter No. 2022/CE-I/CT/GCC-2022/POLICY/Pt.I (E-3320424) New Delhi, Dated 13.03.2026). Bid quoted Below 0 - 5% (inclusive) of advertised cost - Additional Performance Guarantee Nil. Bid quoted Below 5% of advertised cost - Additional Performance Guarantee - 5%
Tenderer Credentials: Documents testifying tenderer previous experience and financial status should be produced along with the tender. (Clause 11, Page-16-17, Part-I of GCC April 2022)
(i) Certificates and testimonials regarding contracting experience for the type of job for which tender is invited with list of works carried out in the past.
(ii) Audited Balance Sheet duly certified by the Chartered Accountant regarding contractual payments received in the past. The documentary proof whether the Balance sheets of each year are audited or not must be submitted. Audited Balance sheet with UDIN shall be submitted to established authenticity of the submitted documents.
(iii) The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
(iv) A copy of certificate stating that they are not liable to be disqualified and all their statements / documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested / digitally signed by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document.
(v) The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under.
(vi) (a) In case of any information submitted by tenderer is found to be false, forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Bid Security besides banning of business for a period of upto two years. (b) In case of any information submitted by tenderer is found to be false, forged or incorrect after the award of contract, the contract shall be terminated. Bid Security, Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of upto two years.
Non-compliance with any of the conditions set forth therein above is liable to result in the tender being rejected.
This tender complies with Public Procurement Policy (Make in India) Order, 2017 - Revision dated 16/09/2020, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2020/RS(G)/779/2/Pt.1 dated 25/09/2020 and amendments / revisions thereof." The full details of the order can be seen at http://dipp.nic.in/whats-new/publicprocurement- preference-make-india-order- 2017. (Authority Railway Boards L. No. 2020/RS(G)/779/2/Pt.1 dated 25-09- 2020)
Contractor is to abide by the provisions of various labour laws in terms of above clause 54, 55, 55-A and 55-B of the Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website ''www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/ company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. (Page- 86-89, Part-II of GCC-April 2022)
Udhna - Electrical (Power) work in connection with providing cover over platform, toilet blocks, seating arrangement and other minimum essential facilities on platform No. 6.
EL-81-38-203-WA-91
EL-81-38-203-WA-91
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹2.5 L
7 May 2026
9 Apr 2026
23 Apr 2026
93 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,26,73,572 | ||
| — | 300.00 | — | — | ||
| Supply of material and providing light/fan point wiring in PVC casing capping / PVC conduit, as per site requirement, with single core multi-strand copper wires, PVC insulated unsheathed, LSHF / ZHFR, of size 1.5 sq.mm. with set of 3 wires for phase, neutral & earth and modular switches, complete with all accessories, junction box, ceiling rose etc, as per specifications in Annexure I. | — | — | — | 1,07,400 | |
| — | 1000.00 | — | — | ||
| Supply of material and providing main/ submain wiring, in PVC casing capping / PVC conduit, as per site requirement, with single core multi-strand copper wires, PVC insulated unsheathed, LSHF / ZHFR, of size 2.5 sq.mm. with set of 3 wires for phase, neutral & earth wire, as per specifications in Annexure II. | — | — | — | 88,000 | |
| — | 3000.00 | — | — | ||
| Supply of material and providing main/ submain wiring, in PVC casing capping / PVC conduit, as per site requirement, with single core multi-strand copper wires, PVC insulated unsheathed, LSHF / ZHFR, of size 4.0 sq.mm. with set of 3 wires for phase, neutral & earth wire, as per specifications in Annexure II. | — | — | — | 3,60,000 | |
| — | 25.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of two module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 3,400 | |
| — | 20.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of four module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 2,960 | |
| — | 20.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of six module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 3,340 | |
| — | 20.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of eight module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 3,700 | |
| — | 20.00 | — | — | ||
| Supply and fixing of modular concealed mounting box of twelve module, with suitable modular base plate and cover, for fixing of modular switches, sockets etc., as per specifications in Annexure III. | — | — | — | 4,720 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular socket 3 pin of 10A capacity with 10A one way modular switch, as per specifications in Annexure IV. | — | — | — | 32,600 | |
| — | 75.00 | — | — | ||
| Supply, fixing, testing & commissioning of modular power socket 3 pin twin heavy duty of 10/20 A capacity with 20A one way modular switch having neon indicator, as per specifications in Annexure V. | — | — | — | 21,975 | |
| — | 10.00 | — | — | ||
| Supply, fixing & commissioning of weather proof modular power socket 3 pin twin heavy duty of 10/20A capacity with 20A SP modular MCB in enclosure made of non metallic polycarbonate thermoplastic material, IP 65, as per specifications in Annexure VI. | — | — | — | 15,000 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing & commissioning of DP MCB (6-40A) in m.s. enclosure, as per specifications in Annexure VII. | — | — | — | 11,160 | |
| — | 10.00 | — | — | ||
| Supply, fixing & commissioning of DP MCB 6-40A, in enclosure made of non metallic polycarbonate thermoplastic material, IP 65 weatherproof, as per specifications in Annexure VIII. | — | — | — | 10,640 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing & commissioning of 63A 4P MCB with m.s. enclosure, as per specifications in Annexure IX. | — | — | — | 11,155 | |
| — | 5.00 | — | — | ||
| Supply, fixing & commissioning of MCB DB three phase with RCBO, I/C: - FP RCBO of 63Amp - 1No and O/G: SP MCB of 10-32 Amp - 12Nos,., enclosure made of non metallic polycarbonate thermoplastic material, IP 65 weatherproof, as per specifications in Annexure X. | — | — | — | 53,300 | |
| — | 91.00 | — | — | ||
| Supply of energy efficient BEE 5 star rated BLDC ceiling fan 1200mm (48") sweep, with down rod and standard accessories, fan & regulator shall be compatible to work with various makes & models, as per specifications in Annexure XI. (Minimum Warrantee - 2 years) | — | — | — | 2,11,302 | |
| — | 91.00 | — | — | ||
| Fabrication, supply and fixing of MS clamps with MS hook made with MS rod of 12mm dia., as per site requirement for installation of ceiling fans in covershed. The clamp shall be made from 30mm x 6mm MS flat in suitable shape, properly galvanized. The firm shall check the site for exact size & shape of clamps as per platform steel structure before fabrication and supply. | — | — | — | 17,381 | |
| — | 500.00 | — | — | ||
| Supply, fixing, testing & commissioning of outdoor type LED tube light luminaires 40W maximum, 4 ft long, whether proof having IP 65/66 protection, System efficacy greater than or equal to 110 lm/W, Lumen Output greater than or equal to 4000 lumens, Colour consistency CRI greater than or equal to 80. Driver Surge protection greater than or equal to 4KV. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). IK 08 protection for durability. Luminaires complete with all accessories and other specifications as per Annexure XII. (Minimum Warrantee - 5 years) | — | — | — | 18,89,500 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 45W maximum, whether proof having IP 65/66 protection, System efficacy greater than or equal to 120 lm/W, Lumen Output greater than or equal to 5400 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV, The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaries complete with all accessories and other specifications as per Annexure XII. (Minimum Warrantee - 5 years) | — | — | — | 89,640 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 60W maximum, whether proof having IP 65/66 protection, System efficacy greater than or equal to 120 lm/W, Lumen Output greater than or equal to 7000 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV. The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaries complete with all accessories and other specifications as per Annexure XII. (Minimum Warrantee - 5 years) | — | — | — | 53,275 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing & commissioning of LED street light lumaires 120W maximum, whether proof having IP 65/66 protection, System efficacy greater than or equal to 120 lm/W, Lumen Output greater than or equal to 14000 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV.The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaries complete with all accessories and other specifications as per Annexure XII. (Minimum Warrantee - 5 years) | — | — | — | 78,320 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing & commissioning of outdoor type LED flood light luminaires 200W ± 10%, whether proof having IP 66 protection, System efficacy greater than or equal to 130 lm/W, Lumen Output greater than or equal to 26000 lumens, Colour consistency CRI greater than or equal to 70. Driver Surge protection greater than or equal to 4KV. The luminaire should have a potted driver, mounted inside the luminaire. Luminaire should have Class B serviceability (i.e., the driver can be replaced or maintained at site). Luminaires complete with all accessories and other specifications as per Annexure XII. (Minimum Warrantee - 5 years) | — | — | — | 2,66,280 | |
| — | 500.00 | — | — | ||
| Survey, design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 Micrometer thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. In case of double sided glow sign, the quantity will be counted as 1.3 times of the schedule quantity. Details as per specifications in Annexure XIII. | — | — | — | 10,92,000 | |
| — | 500.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 Micrometer thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. In case of double sided glow sign, the quantity will be counted as 1.3 times of the schedule quantity. Details as per corresponding specifications in Annexure XIII. | — | — | — | 1,08,500 | |
| — | 1000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 16 sq.mm.x 4 core, as per specifications in Annexure XIV. | — | — | — | 1,08,000 | |
| — | 1000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 25 sq.mm.x 4 core, as per specifications in Annexure XIV. | — | — | — | 1,57,000 | |
| — | 1000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 50 sq.mm.x 4 core, as per specifications in Annexure XIV. | — | — | — | 2,56,000 | |
| — | 1500.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 70 sq.mm.x 4 core, as per specifications in Annexure XIV. | — | — | — | 6,96,000 | |
| — | 1000.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded aluminum conductor cable of size 95 sq.mm.x 4 core, as per specifications in Annexure XIV. | — | — | — | 4,60,000 | |
| — | 959.00 | — | — | ||
| Supply of XLPE insulated, PVC sheathed, armoured 1.1 KV grade, multi-stranded copper conductor cable of size 35 mm² x 4 core, as per specifications in Annexure XIV. | — | — | — | 29,00,975 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing & commissioning of aluminium lugs of size 50 sq.mm. for cable termination, as per specifications in Annexure XV. | — | — | — | 1,500 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing & commissioning of aluminium lugs of size 70 sq.mm. for cable termination, as per specifications in Annexure XV. | — | — | — | 2,400 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing & commissioning of aluminium lugs of size 95 sq.mm. for cable termination, as per specifications in Annexure XV. | — | — | — | 3,100 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing & commissioning of heavy duty copper lugs of size 25/35 sq.mm. for cable termination, as per specifications in Annexure XVI. | — | — | — | 5,400 | |
| — | 200.00 | — | — | ||
| Supply & fixing of heavy duty pipe, made of glass fiber reinforced polyester moulding composite material, Size 50mm dia, 3mm thick, for cable protection as per specifications in Annexure XVII. | — | — | — | 86,000 | |
| — | 50.00 | — | — | ||
| Supply & fixing of heavy duty pipe, made of glass fiber reinforced polyester moulding composite material, Size 75mm dia, 3mm thick, for cable protection, as per specifications in Annexure XVII. | — | — | — | 47,550 | |
| — | 600.00 | — | — | ||
| Supply and fixing of GRP / FRP cable tray, RED in colour, made of glass fiber reinforced polyester moulding composite material, size 200mm width x 75mm depth min., 04mm thick min., including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc., as per specifications in Annexure XVIII. | — | — | — | 4,51,200 | |
| — | 600.00 | — | — | ||
| Supply, fixing, testing and commissioning of bus duct trunking system of 40A (4+2) conductors, 3ph, 4 wire, IP55 with center feed unit, 16A lap off box, plug outlet covers, 16A 1ph selection plugs suitable for glass fuse, ceiling bracket holder, suspension clamp, wall bracket, suspension hook, snap clamp etc. All suspension accessories shall be either galvanized or powder coated, as per specifications in Annexure XIX. | — | — | — | 17,85,000 | |
| — | 450.00 | — | — | ||
| Supply, fixing, testing and commissioning of plug in box/ tap off box of bus duct trunking system with connecting wire of 3 core x 1.0 sq.mm. in PVC conduit to complete the wiring connection to light/ fans, including all material required for fixing arrangement, as per specifications in Annexure XX. | — | — | — | 2,46,150 | |
| — | 24.00 | — | — | ||
| Supply, fixing, testing and commissioning of flexible bend of 40A (4+2) conductors for bus duct trunking system, 3ph, 4 wire, IP55, including all necessary components for connecting two ends of bus trunking, as per specifications in Annexure XXI. | — | — | — | 2,38,080 | |
| — | 27.00 | — | — | ||
| Dismantling of rail poles / light poles by digging a pit around the pole and cutting it 1-1.5 Ft below ground level, filling up the pit with cement concrete mixture, and removing the debris from the site, complete with removal of conductor wires, light fittings, and other accessories and transportation from site to location in the station premises area as advised by SSE, as per scope of work in Annexure XXII. | — | — | — | 73,575 | |
| — | 27.00 | — | — | ||
| Removal of rail poles/ light poles by digging a pit around the pole and cutting it 1.5 feet below ground level, filling up the pit with cement concrete mixure, as per scope of work in Annexure XXIII. | — | — | — | 73,224 | |
| — | 27.00 | — | — | ||
| Stocking of rail poles/ light poles at locations advised by railway authority at the nearest station, as per scope of work in Annexure XXIV. | — | — | — | 13,149 | |
| — | 10.00 | — | — | ||
| Supply of material & installation of maintenance free earth electrode of length 3 meter, including earth enhancement material for earthing for each electrode & other accessories as per Drg. No. SDO/ RDSO/ E&B/001 and RDSO Spec No. RDSO/SPN/197 /2008, as per Annexure XXV. | — | — | — | 1,11,790 | |
| — | 101.00 | — | — | ||
| Supply, fixing, testing & commissioning of G.I. strip 25mm x 6mm for earthing, including cutting, bending, welding, excavation etc., as per specifications in Annexure XXVI. | — | — | — | 10,706 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing and commissioning of Pre-cooling box 3 phase, 440V, with thermoplastic polycarbonate box, having 1 No. MCCB of 100 Amp capacity and heavy duty D-contactor socket of 5 pin of 63 Amp, 415 Volts; Design to be approved before supply of material. Specifications in Annexur XXVII. | — | — | — | 4,11,225 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April-2022.pdf
ATTACHMENT
ClubbedCorrectionSlips.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf Correction
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
AnnexureVIBAnnualContractualTurnoverGCC2022.pdf
ATTACHMENT
BankGuaranteeFormat.pdf
ATTACHMENT
InsuranceSuretyBondforPerformanceSecurity.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
Signages_Standard_SizesforTenders.pdf
ATTACHMENT
EL-81-38-203-WA-912025-2026.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .