GE Jammu
GE Jammu c/o 56 APO Pin-180003
REPAIR AND MAINT OF UG CABLES, ACSR CONDUCTOR, POLES, LT DISTRIBUTION SYSTEM, SECURITY / STREET LIGHTS, SOLAR LIGHTS AND CONNECTED WORKS AT SUNJUWAN, BALIDAN STAMBH, SAINIK ARAM GHAR UNDER GE JAMMU
2021_MES_455362_1
GEJC-22/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹96,000
Yes
3 Sept 2021
28 Jun 2021
26 Jul 2021
28 Jun 2021
24 Jul 2021
12 Jul 2021
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 deep for foundations of poles/stays/cable etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches exc 1.5 m wide and n.exc 3.0 deep for foundations of poles/stays/cable etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in earth including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick each layer complete all as specified and directed.
Removing of surplus soil to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and as directed by Engr-in-Charge.
M&L for sand cushioning with a layer of fine sand (sand for plastering) 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent/abutting each other in trenches over the cable for protection complete all as specified and as directed by Engineer-in-Charge.
Relaying of serviceable bricks breadth wise in trenches for UG cable protection complete all as specified and directed.
Dismantling/uprooting of LT unserviceable pre-stressed concrete/steel poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and directed. Note:- Earth work for taking out of poles shall be measured and paid separately under relevant item of this Schedule.
Dismantling cross arms of MS channel or angle sections etc. and keeping serviceable materials in safe custody for re-use and/or unserviceable materials removing from the site(s) complete all as specified and directed.
Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s) complete all as specified and as directed. Note: - a) Unserviceable stay assembly shall be taken off/dismantled at ground level and making good disturbed ground surface. b) Earthwork for demolition of cement concrete rate should be included in quoted rate.
Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re-use and unserviceable materials removing from the site(s) complete all as specified and as directed.
Dismantling earth wire of any size/dia or copper conductor, guarding craddle or disturbed span and keeping serviceable materials in safe custody for re-use and removing unserviceable materials from the site (s) complete all as specified and as directed.
Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and/or unserviceable materials removing from the Site(s), complete all as specified and as directed.
Supplying, erecting and fixing pre-stressed concrete poles 9 mtr long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint in black and white strips each 30 cm wide each up to 1.5mtr high from coping over a coat of primer including numbering of poles complete all as specified and as directed.
M&L for PCC(1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of electric poles, struts, PCC blocks etc including necessary form work complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of assembly, bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified, struts, PCC blocks etc including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed.
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections, including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat (red oxide, zinc chrome primer), one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and as directed.
Fixing only serviceable cross arm, MS Channel, angle section obtained from item No 9.00 here-in-before as ordered and inclusive of one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed.
S&F stay assembly comprising of stay bow 40cm long, 16mm dia, complete with accessories as shown in electrical Plate No-1 of SSR Part-1 with and including 16mm dia stay rod 180cm long with threaded ends, GI nuts, check nuts, bolts, washers 2 thimbles MS clamp made out of 40x6mm flat Iron includig nuts, bolts and washers, 230mm x 230mm x 6mm thick stay plate and also exposed surfaces shall be given two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repair loop type insulators vitreous porcelain white / brown or green small size with overall dimensions 65 x 90 mm clearance of hole 16 mm dia complete all as specified and directed.
S&F in repair galvanized stay strand of size 7/4.00 mm complete all as specified and as directed.
M&L aluminium conductor steel reinforced (ACSR) of sizes on LT poles including straining, binding with insulators with aluminium binding wire with insulator as in OH conductor, providing PVC sleeves for jumpers complete all as specified and as directed.
Fixing only by re-straining, tightening of ACSR conductors of any size/type on HT/LT poles including necessary new aluminium binding wire for fixing with insulator/PVC sleeves for jumper etc as required complete all as specified and as directed. Note : Serviceable ACSR conductors shall be obtained from item No. 11.00 here-in-before.
S&F in repair PVC fibre separator for LT line 1100 volt OH conductor 3/4 wire system for maintaining horizontal spacing of conductor complete with nut and bolt minimum two no's in a span complete all as specified and as directed.
M&L galvanised steel continuous earth wire 3.15 mm or 4 mm dia and fabricating cradles, hexagonal/rectangular complete all as specified and as directed.
Fixing only serviceable GI wire 3.15 mm or 4 mm dia martial obtained from item No 12.00 here-in-before complete all as specified and as directed.
S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all specified and directed.
Fixing only serviceable pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
S&F shackle type, porcelain, vitreous white, brown or green insulator including galvanised mild steel straps of size 31 x 3 mm, 12 mm dia insulator bolts, nuts and washers for working pressure 1100 volts of size 75 mm height, 90 mm dia complete as specified and directed.
Fixing only serviceable shackle type, porcelain, vitreous white, brown or green insulator including galvanised mild steel straps of size 31 x 3 mm, 12 mm dia insulator bolts, nuts and washers for working pressure 1100 volts of size 75 mm height, 90 mm dia complete all as specified and as directed.
Taking out old / unserviceable under ground LT cables, sub main wiring and connections including pipes, bricks or precast concrete cable cover etc of any from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site complete all as specified and as directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 300 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and pannels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 185 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 95 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 50 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 35 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sq mm 2 core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying mild steel galvanised iron pipe light grade 80mm bore (for passing of cable/laid in trenches fixed to pole / walls / laid under floors / roads) complete with and including fittings as required in repair complete all as specified and directed.
Supply and laying mild steel galvanised iron pipe light grade 50mm bore (for passing of cable / laid in trenches fixed to pole / walls / laid under floors / roads) complete with and including fittings as required in repair complete all as specified and directed.
Labour for Horizontal Boring Road/Foot Path, not exc. 20.00 metre in length complete all as specified and directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 25 to 50 sq mm complete all as specified and directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 70 to 95 sq mm complete all as specified and directed.
M&L for road cutting, PCC hard standing with width 0.4 and depth 0.6 mtr including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface complete all as specified and directed.
Supply and fix in repair cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AL conductor cable of size 95 Sqmm complete all as specified and directed.
Supply and fix in repair cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AL conductor cable of size 95 Sqmm complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground vertically to a depth not less than 3 mtr below ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers, all around, top and bottom and electrode connection by using galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 15mm bore protection pipe light grade for protection strip upto 3m above ground level fixed with two clamps of size 25mm x 3mm flat iron and connected to running earth wire at top of poles for protection of GI wire. PCC chamber in cement concrete (1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion. Notes :- (a) The unit rate shall include for protection pipe, GI water pipe, funnel, wire mesh excavation, RCC pit cover, test point, 4 mm dia galvanised iron wire from top of earth plate upto 5mtr above ground level and if ground level protection is less than 5m, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earth work is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account. (d) Earthing work will be carried out in presence of MES representative.
M&L for refixing at said location with replacement of below mentioned items including connecting the MCCB's bus bars with suitable size of PVC insulated copper cable, copper lugs, cable gland, bolts, nuts and washers, phase terminals etc. complete as specified and directed by Engr-in-charge. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
S&F in repair MCCB 4 pole 630 A breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type) adjustable thermal and adjustable magnetic setting, lcs=75% of lcu complete all as specified and directed.
S&F in repair MCCB 4 pole 250 A breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type) adjustable thermal and adjustable magnetic setting, lcs=75% of lcu complete all as specified and directed.
S&F in repair MCCB 4 pole 400 A breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type) adjustable thermal and adjustable magnetic setting, lcs=75% of lcu complete all as specified and directed.
S&F in repair MCCB 3 pole 250 A breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type) adjustable thermal and adjustable magnetic setting, lcs=75% of lcu complete all as specified and directed.
S&F in repair MCCB 3 pole 200 A breaking capacity 50 KA at 415 Volt AC, 50 Hz (L frame type) adjustable thermal and adjustable magnetic setting, lcs=75% of lcu complete all as specified and directed.
S&F in repair MCCB 3 pole 160 A breaking capacity 36 KA at 415 Volt AC, 50 Hz (HID Series type) adjustable thermal and fixed magnetic setting, lcs=100% of lcu complete all as specified and directed.
S&F in replacement unsv indicators LED set of three pieces as per existing size and sample complete all as specified and directed.
S&F in repair copper wound CT 100/5-03 No's complete all as specified and directed.
S&F in replacement Ampere meter digital type 0-200 / 0 to 400, 0 to 600, 96 sqmm square type flush panel mounted complete all as specified and directed.
S&F in repair Volt meter digital type 0-500 Volt, 96 sqmm square type flush panel mounted complete all as specified and directed.
M&L for replacement of old burnt out aluminium bus bar and connected link bar with proper colour coding with insulation tape of current rating 630/400 Amps including replacement of old rusted nut and bolts, washers complete all as specified and directed.
Supply and fix in replacement of change over switch AC - 230 Volt (side handle) in sheet metal enclosure of capacity 100 Amp, 415 volts 3 phase, four pole complete all as specified and directed. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
Supply and fix in replacement of change over switch AC - 230 Volt (side handle) in sheet metal enclosure of capacity 200 Amp, 415 volts 3 phase, four pole complete all as specified and directed. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
Supply and fix in replacement of change over switch AC - 230 Volt (side handle) in sheet metal enclosure of capacity 400 Amp, 415 volts 3 phase, four pole complete all as specified and directed by Engr-in-charge. Note: Wherever is cable fixing/connection suitable thimble should be used as per site situation.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 70 sq mm 3½ core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 16 sq mm 2 core with necessary aluminium lugs/thimble as required at site to connect the cables to equipment and panels complete all as specified and directed.
Supplying and fixing in replacement of PVC flat serviceable cable 10 sqmm 2 core multi stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
Supplying and fixing in replacement of PVC flat serviceable cable 16 sqmm 2 core multi stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
M&L for replacement distribution board sheet metal enclosure steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door flush to wall fitted complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L for replacement distribution board sheet metal enclosure steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door flush to wall fitted complete all as specified and directed. Note:- Distribution board and MCB's should be same make.
M&L for replacement distribution board double door sheet steel phosphatised powder painted for MCB/DB with copper bus bar and neutral link earthing stud TPN 4 way 415 volts doubled door complete all as specified and directed.
S&F in replacement TP&N vertical load line double door DB with 200 Amps bus bar, 415 Volt sheet metal enclosure suitable for 'G' frame MCCB 4 way complete all as specified and directed.
S&F in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of cap 125 Amps, 10KA complete all as specified and directed.
S&F in replacement isolator 4 pole, TPN 415 volts, 100 Amps rating with rupturing cap 10 KA, complete all as specified and directed.
S&F in replacement for MCB TP&N 63 Amps 415 Volts, 'B' series rupturing capacity 10 KA complete all as specified and directed.
S&F in replacement for MCB SP 6 to 32 Amps, 240 Volt, 'B' series complete all as specified and directed.
S&F in replacement for MCB SPN 32 Amps 240 Volts, 'B' series complete all as specified and directed.
S&F in replacement for MCB SPN 63 Amps 240 Volts, 'B' series complete all as specified and directed.
Supply and fixing in replacement of sheet steel cable and box (bus-bar) 4 way 440 volt, 50 Hz single door with 200 Amp rated bus bar mounted on insulator complete all as specified and directed.
M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 sqmm for phase and neutral and one run of 4.0 sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 sqmm for phase and neutral and one run of 2.5 sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding.
S&F in replacement of GI tube light grade 40 mm bore laid in trenches/road/drain/wall alongwith all fittings complete with MS clamp and nut, bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and directed.
Labour only for repairing and rectification of faults in security lights / street lights / highbay lights by disconnecting the electrical connections and bringing on ground and refixing the same, back in position after carrying out repairs by checking the peanut lamps / electrical connections / electronic drivers etc. and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. Notes: (i) One Electrician and one helper shall be deputed daily to JE E/Ms office during office hours to ascertain the repairs to be carried out for lights under his AOR. (ii) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as supply only. (iii) Necessary arrangements for carrying out repairs shall be undertaken by the contractor.
Labour only for repairing and rectification of faults in high mast light fixed at a height of 16m to 32m by disconnecting the electrical connections and bringing on ground by operating existing motor and refixing the same, back in position after carrying out repairs by checking the peanut lamps / electrical connections / electronic drivers etc. and testing after making it fully serviceable by checking the condition of electronic driver and replacing only if required complete all as specified and as directed. NOTES: (i) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as supply only. (ii) Necessary arrangements for carrying out repairs shall be undertaken by the contractor.
Supply only high energy efficient constant current electronic driver suitable for 220 V, 50 hz, LED street light fitting 18 / 36 watts LED luminaries, 230 Volts complete all as specified and directed. Make : Crompton /Bajaj/Philips/Havells/Wipro
Supply only high energy efficient constant current electronic driver suitable for 220 V, 50 hz, LED street light fitting 40 / 45 / 50 / 60 watts LED luminaries, 230 Volts complete all as specified and directed. Make : Crompton / Bajaj / Philips / Havells / Wipro
Supply only high energy efficient constant current electronic driver suitable for 220 V, 50 hz, LED street light fitting 75 / 80 / 90 watts LED luminaries, 230 Volts complete all as specified and directed. Make : Crompton / Bajaj / Philips / Havells / Wipro
Supply only high energy efficient constant current electronic driver suitable for 220 V, 50 hz, LED street light fitting 100 / 120 Watts LED luminaires, 230 Volts complete all as specified and directed. Make : Crompton / Bajaj / Philips / Havells / Wipro
Supply only LED driver suitable for 150 watt / 200 watt LED fittings in high mast lights complete all as specified and as directed. MAKE : PHILIPS / CROMPTON GREAVES / BAJAJ (to be provided as per the existing make only).
M&L for servicing of solar street light including cleaning of solar panels, checking and cleaning battery and all connection terminals, distilled water topup, solar battery charging controller, LED driver complete all as specified and directed.
S&F in repair solar street light lead acid battery 12v, 75Ah complete all as specified and directed. Make: - Exide / Amaron / Sonic
S&F in repair MPPT Solar PWM controller suitable for battery sizes 12/24/36/48V, 40/60A including connection and testing complete all as specified and directed.
S&F in repair monocrystalline solar photo voltaic 12V, 180 W panel suitable for solar street light including fixing on existing mounting brackets with appropriate angle 45˚ to 60˚ to attain maximum efficiency including connecting and testing complete all as specified and directed.
S&F in repair post top lantern LED type 30 watt 230 watt volts AC outdoor type with decorative post top for 360° indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make : Philips/Havells/Crompton
M&L in replacement of PVC insulated and sheathed cable of size 1.5 sqmm 3 core aluminium conductor multistranded 1100 volt grade 230 volts complete all as specified and directed.
S&F fabrication bracket made out of GI tubing suitable for 45/60/90 watt LED light grade upto 1.2 mtr length, bend to shape suitable for security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Taking down old unserviceable LED Street light / flood light fitting of any type from the pole / bldg after disconnecting electric connection carefully complete all as specified and directed.
S&F in replacement LED street light fitting 120 watt comprising a single piece, environment friendly light fittings including electronic driver, luminarie housing is of pressure die-cast alluminum alloy LM-24 for gear and extruded aluminium lamp housing, operating voltage range is from 85 Volts to 264 Volts AC 50 Hz complete all as specified and directed.
S&F in replacement of LED street light fitting 90 watt comprising a single piece, environment friendly light fittings including electronic driver, luminarie housing is of pressure die-cast alluminum alloy LM-24 for gear and extruded aluminium lamp housing, operating voltage range is from 85 Volts to 264 Volts AC 50 Hz complete all as specified and directed.
S&F in replacement of LED street light fitting 60 watt comprising a single piece, environment friendly light fittings including electronic driver, luminarie housing is of pressure die-cast alluminum alloy LM-24 for gear and extruded aluminium lamp housing, operating voltage range is from 85 Volts to 264 Volts AC 50 Hz complete all as specified and directed.
S&F in replacement of LED street light fitting 45 watt comprising a single piece, environment friendly light fittings including electronic driver, luminarie housing is of pressure die-cast alluminum alloy LM-24 for gear and extruded aluminium lamp housing, operating voltage range is from 85 Volts to 264 Volts AC 50 Hz complete all as specified and directed.
S&F in replacement of LED flood light fitting of cap 200 watt including inbuilt surge protection as per requirement LED flood light fittngs along with IP-65 protection complete all as specified and directed.
Sarbat Construction Co
M/s. Aggarwal Engineers
M/S S K Electricals Regd
bamral builder
SATISH AND CO
Bidder Name
M/S S K Electricals Regd
SATISH AND CO
Sarbat Construction Co
M/s. Aggarwal Engineers
bamral builder
M/S BALI AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .