| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹36.3 L+₹5.9 L (19.5%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance Other tan lowest | |
| 3 | L3₹36.6 L+₹6.2 L (20.4%)Rejected-Finance | L3 | Rejected-Finance Other tan lowest | |
| 4 | L4₹37.5 L+₹7.1 L (23.4%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other tan lowest | |
| 5 | L5₹39.2 L+₹8.8 L (29.1%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L5 | Rejected-Finance Other tan lowest |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM CHAKERI
PROVN OF SECURITY LIGHTS AND CABLING AT CERTAIN LOCATIONS ON PERIMETER ROAD AT AFS KANPUR
2024_MES_640464_1
8695/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹89,800
Yes
13 Jun 2024
2 Feb 2024
5 Mar 2024
3 Feb 2024
29 Feb 2024
16 Feb 2024
Amount
Excavation in trenches not exceeding 1.5 wide and not exceeding 1.5 m in depth for laying of cables, pipes and getting out including trimming the sides and forming botton surfaces to requried levels in soft/loose soil complete all as specified and directed.
Returning, filling in and including spreading,leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
Suppy and spreading ganga sand dry, clean in trenches as cushioning to underground electric cable provided with a layer of 80 mm deep before laying and 150 mm over cable laid in trenches complete all as specified and directed. Note:- Punned thickness shall be considered for measurement purpose.
M & L for well burnt brick sub class B old size of 23 cm x 11.5 cm x 7.5 cm laid dry with width equal to length of whole brick in trenches for cable protection complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where diredted at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M & L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width & not exceeding 60 cm in depth for passing of LT cable and making good of disturbed surface to make with the existing surfaces by using old and new material upto 15 cm in depth and providing 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate finished fair and even complete all as specified and directed.
M & L for making horizontal boring 60 cm deep below road crossing for passing of LT cable in GI pipe complete all as specified and directed.
Supply and laying in trenches / floor or fixed to pole / Wall GI light grade 50 mm boreeith fitting for protecting of cable complete all as specified and directed by Engineer in Charge. Make :- Jindal / Tata / Prakash Surya
Supply, laying, and testing of LT cable XLPE insuable sulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty ) 1100 vilts grade with stranded aluminium conductor of size 16 sq mm 4 core laid in trenches / duct / laid on wall etc. inci. end termination , suitable size lugs, thimbless, glands, nuts, bolts, washers,insulation tape etc. complete all as specified and directed by Engineer in Charge. Make:- Havells / Grandlay / Gloster
All as per item No 9 above but size 25 Sqmm 4 core
All as per item No 9 above but size 25 Sqmm 3.5 core
All as per item No 9 above but size 95 Sqmm 3.5 core
M & L in replacement for new steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws ,type 410 SP-31 ( 9 mtr height) complete including providing two coats of alumnium paint over a coat of red oxide primer and marking pole number with Black Paint as directed by Engineer in Charge all as specified and directed. Note: Excavation, earth work, concrete shall be measured & paid seperately
M & L for plain cement concrete 1:4:8 type D2 usong 40 mm graded stone aggregate as in foundation, filling and mass concrete of pole complete all as specified and directed.
M & L for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregete as in coping of pole complete all as specified and directed.
Material and Labour for mounting bracket made out of galvanized iron medium grade of 40 mm bore bended into requiried shape and size of 1.5 mtr including necessary flat iron clamps made out of 25x4 mm flat iron, nuts, bolts & necessary connections complete all as specified and directed.
S & F Street light junction box 225 mm x 295 mm x 122 mm comprising of 4 nos of aluminium bus bars of suitable rating mounted on epoxy insulators with holes for incoming and outgoing cables, 2 nos of MCB 16 A SPN, 2 nos cable gland and provision for inserting wires with suitablr mounting arrangement on street light pole with MS clamps junction box having IP 66 protection complete all as specified and directed Make:- Sintex / Rittal / Hensel
Supply and fixing of PVC insulted wire copper conductor 1.5 Sqmm 3 core connected with street light to junction box for steel tubuler pole complete all as specified and directed.
M & L for street light timer incl. testing of NATURE Switch for outdoor lighting auromarion using space grade sensors.micro controller suitable for outdoor use IP 55 having features Automatic Switching On at Sunset, Automatic Switching OFF at dawn, No clock setting wide operating voltage range, high voltage trip and reset having specification 230 Volts, 50 Hz with all connected accessories 3 phase, 8 KW complete all as specified and directed. Make:- Kakatiya Energy System PVT Ltd / Bajaj / Healer.
Supply , installation, commissioning and testing of outdoor type LT panel (CPRI Approved) IP-54 protection made out of 3.15 mm thick CRCA sheet matal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 phase, 4 wire, 415 volts properly insulated aluminium bus bar - 04 Nos having capacity 200 amps on phase & neutral dust and vermin proof,both side open with locking arragement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size bulit with brick work in CM (1:4) 15 mm thick plastering in CM (1:6) including glands, lugs,thimbles for all cables complete all as directed Incoming / Outgoing: (i) MCCB 100Amp, 25kA, 415V, 4P-01 No Make MCCB: L&T / Legrand / ABB
Supply, installation, commissioning and test of outdoor type LT panel (CPRI Approved) IP - 54 protection made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 phase, 4 Wire, 415 Volts properly insulated alluminium bus -04 Nos having capacity 400 amps on phase & neutral,dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated,fixing in position by provision of platrform suitable size built with brick work in CM (1:4) 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all cables complete all as directe. Incoming: (i) MCCB 250 Amp, 36kA, 415V, 4P -01 No Outgoing: (i) MCCB 100 Amp, 25kA, 415V, 4P -02 No (ii)MCCB 63 Amp, 25kA, 415V, 4P -02 No Make MCCB : L&T / Legrand / ABB
S & F of energy saving & enviroment friendly LED street light fittings made out of pressure die cast anodized aluminiun housing having rating 90 watt with high efficiency polycarbonate UV stablizer cover with integrated lens to ensure asymmetrical light and overall PI 65 protection complete all as specified and directed.
S & F of LED Flood light of 100 watt comprising of pressure die cast aluminium housing and high purity electro polished anodised aluminium heat shrink with toughened glass of UV stabilised polycarbonat cover for lamp compartment including necessary accessories for effective range complete all as specified and directed.
All as per item No 23 above but flood light of 120 watt
M & L for earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directky to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge plate not less than 1.5 mtr below normal ground level connected to GI strip 32 x 6 mm as earthing lead protected with 40 mm dia GI pipe light grade filling around with charcoal dust and salt including excavation, filling of earth and disposal of surplus soil to a distancenot exceeding 50 mtr and connected by means of GI nuts, bolts and washers including chamber PCC 1 : 3 : 6 type C1 using 20 mm graded stone aggregate in concrete precast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete includng testing complete all as specified in electrical plate no.3 of SSR Part-I(2009) and directed by Engineer in Charge. Note: GI strip up to 7.5mtr shall be deemed to be included in quoted unit rate.
Ashirwad Contractor and Supplier
Vee Key Enterprises
BHATIA ENTERPRISES
santosh electronics
M/s Sohanil Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .