Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC PANDIT JAGAN NATH WALI GALI MALOUT DISTT SRI MUKTSAR SAHIB | SRI MUKTSAR SAHIB | PUNJAB | 151202 | L1 | Accepted-AOC L1 |
Tender Value
₹29.0 L
EMD Value
₹58,080
Closing Date
22 Aug 2019, 5:00 pmClosed
EXECUTIVE ENGINEER
EE WSSD NO.2, FZR AT ZIRA
Augmentation of Water Supply Scheme Gatta Badshah Block Makhu Distt. Ferozepur under 1a(iii)
2019_WB_35918_1
Tender for Village Gatta Badshah under 1a(iii)
Open Tender
Civil Works
Item Rate
390 days
FEROZEPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
TIA
₹58,080
Yes
15 Jun 2020
3 Aug 2019
23 Aug 2019
3 Aug 2019
22 Aug 2019
3 Aug 2019
Amount
Constructing 1 No. of 25 KL (25000Liters ) capacity with sill level not less than 13.00m height upto FSL 15.50 mtr from formation lvel complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing DI K-9 D/F expansion joints conforming to (IS-1536-1989) or lastest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and DI K-9 D/F sluice valave duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet & scour pipes, including providing & installing inlet, outlet, scour pipes and overflow DI K -9 double flanged pressure pipes horizontally cast in sand moulds as per IS -7181/1986 & latest duly ISI marked from bottom dome to duck foot bend and further upto 7.75 mtr. as per detail specifications. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. The specifications & drawings are based on safe bearing capacity of soil of is less than 8.75 ton per sqm. in case the safe bearing capacity of soil is less than 8.75 ton per sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The diffrence in quantities from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR+Prevailing Ceiling Premium including over flow haudi complete in all respect. Providing and fixing automatic electronic water level control device and construction of Plinth Protection around OHSR with masonary toe wall with 40mm thick CC 1:2:4 on top over 100mm thick CC 1:8:16 & inside earth filling complete in all respect.
Providing, Laying, Fixing & Jointing of PVC pipes (ISI Marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing & testing, complete as per specifications
110mm o/d PVC Pipe 6 kg
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department size 0.60m x 0.60m
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 2 & Drawings D-12 & D-17.
Construction of V-NOTCH Haudi (Size 1.80 m x 0.90m ) excluding cost v-notch as per standard design and drawings of Public Health Department.
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications.(as per AC slip no 11) for Manually Excavation including speicals (6kgf/ cm2) Pressure
Providing, Stringing out PVC pipes 6kgf/ Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with Prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. for more than 3 mtr. Street width. (Mechanically ) (6kgf/ cm2) Pressure
PVC pipe 63mm o/d
PVC pipe 90mm o/d
PVC pipe 110mm o/d
Contractor shall quote rates only for dismantling of metalled road and back filling with excavated earth, fully compacted. The restoration of the metalled road to its original condition will be done by the concerned department I.e PWD (B&R)/PMB/ Panchayti Raj.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Providing house hold connection lying, jointing, fixing, testing MDPE / G.I. pipes (as approved by Engineer-in-charge) including cost of Excavation, Refilling, C.I bib cock as per IS:210 with stainless steel spindle, 20mm o/d MDPE pipe 2.50m (length on average basis), 3"i/d clamp, G.M. ferule ISI marked, connection of 10mm i/d ferrule medium, specials such as tees, bends sockets, elbows, nipples (100mm & 150mm), Union couplings, GI hooks etc and gun metal peet valve (heavy pattern) with hand wheels on MDPE pipe lines laid in the ground or inside building, cutting threading, making hole in wall and testing in trenches in the ground all material should be ISI marked (to the approval of Engineer-in-charge) Complete Job in all respect including cost of carriage. (Refer CSR item Nos. 28.34 b, 30.65 b, 28.40 a, 28.43 a, 28.46)
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. As per analysis A13
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 04No. With each of Size 0.6m x 0.6m
Disinfection unit electrically basen dosing plant on Sodium Hypochlorite along with 200 ltr. Of Sodium Hypochlorite in container complete in all respects (as per Technical Manual of DWSS- Clause 6.45 (c ) (Pg 64)
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of 5.00 BHP KSB or equivalent make capable of delivering 189 LPM against a head of 41.00 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65 mm & length 30 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 65 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Construction of Pump Chamber 2.20 x 2.20 m size including Gravil Pit and cost of electric wiring as per DWSS standard design, Drawing & Analysis, complete in all respects. (Including Carriage of Material)
Provision for Sanitary Latrine near Pump Chamber ( as per IHHL)
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
Providing & fixing G.I. Barbed wire 2 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 (as per Analysis A-8)
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. (As per Analysis).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-9
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-5 including Carriage of material
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-6 complete in all respects . including Carriage of material
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-11. including Carriage of material
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
O&M of scheme for 3 Month after execution of work at site. Including Sallary of Pump Operator , Electricity Bill nad Bleaching Powder
Carriage of Surkhi, sand, bajri, ballast, stone, boulders, kankar, building rubbish
Carriage of material excluding initial lead of 5 Km
Fine Sand From Jalalabad (Av. Lead 108 Km)
Course Sand From Pathankot (Av Lead 190 Km.)
Bajri / Gatka From Pathankot (Av Lead 190 Km.)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .