| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | ₹18.6 L Quoted ₹19.0 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹25.0 L+₹6.0 L (31.7%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹25.0 L+₹6.0 L (31.7%) | L2 | Rejected-Finance Being not lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Mar 2022, 6:00 pmClosed
CWE AF BAMRAULI
HQ CWE AF BAMRAULI ALLAHABAD-211012
REPAIR / MAINTENANCE OF VCB, RMU, DISTRIBUTION TRANSFORMER, GOD, ISOLATION TRANSFORMERS INCLUDING MAINTENANCE OF HT OVER HEAD AND UNDER GROUND CABLE AND CONNECTED WORKS AT AF STATION BIHTA
2022_MES_504998_1
87183/C/E8
Open Tender
Civil Works - Others
Item Rate
273 days
Bihta
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bihta
₹50,000
Yes
14 May 2022
17 Feb 2022
25 Mar 2022
17 Feb 2022
18 Mar 2022
4 Mar 2022
Amount
Excavating in trenches, not exceeding. 1.5metre wide and not exceeding 1.5metre deep and getting out in soft / loosecomplete all as specified and directed by Engineer-in-Charge.
Returning filling in foundation / trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete all as specified and directed by Engineer-in-Charge.
Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Engineer-in-Charge. Note :- Punned thickness shall be measured.
Providing, plain cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.
Providing, plain cement concrete 1:3:6 type B1, (20mm graded crushed store aggregate) as in mass concrete, filling and foundation etc complete all as specified and directed.
Labour only for re-laying bricks in trenches dry well burnt bricks obtained in protections of cable laid flat perpendicular to the direction of cable over sand cushioning for protection of cable complete all as specified and directed.
Supply and laying in trenches dry well burnt best class locally available sub class 'B' bricks over sand cushioning for protection of cable complete all as specified and directed.
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 11000 volts connecting and testing complete all as directed by Engineer-in-Charge Note :- Excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately.
Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured cable with aluminum conductor, 11 KV `E’, of cross sectional area 95 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles road crossing etc including taking out of old Cable complete all as specified and directed by Engineer-in-Charge. Note :- (i) Excavation, earthwork, cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule. (ii) Old cable, cable joint, brick cover, pipe etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.
Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured cable with aluminum conductor, 11 KV `E’, of cross sectional area 185 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles road crossing etc including taking out of old Cable complete all as specified and directed by Engineer-in-Charge. Note :- (i) Excavation, earthwork, cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule. (ii) Old cable, cable joint, brick cover, pipe etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.
Supply, laying & testing cross linked polyethylene insulated (XLPE) galvanised steel strip armoured cable with aluminum conductor, 11 KV `E’, of cross sectional area 240 Sqmm, three core (IS-7098) in trenches/through pipes/ducts or on poles road crossing etc including taking out of old Cable complete all as specified and directed by Engineer-in-Charge. Note :- (i) Excavation, earthwork, cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule. (ii) Old cable, cable joint, brick cover, pipe etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.
Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, outdoor terminitation suitable for cross sectional area 50 to 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for cable jointing kit for 11 KV (earthed) heat shrinkable, indoor termination suitable for cross sectional area 50 to 95 Sqmm, 3 core aluminium conductor XLPE Cable including jointing material and accessories complete and cutting of old cable complete all as specified and directed by Engineer-in-Charge.
Taking down carefully switch air break, gang operated, triple pole complete and Supply, installing, connecting and commissioning switch air break gang operated, triple pole, vertical mounted, out door type of 12 insulators, mechanically operated, mounted on insulators and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe heavy grade worked from ground level, with locking arrangements including brass pad locks with key (Make. Godrej/Harrison/Link) for current rating 200 Amp at 11 KV, complete with drop out fuse set fuse carrier and fuse elements having 100 Amp at 11 KV complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, CI frame and charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment as specified and directed & testing on completion. NOTES : (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 20mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Items includes cost of 7.5 metre earth lead strip. Any variation in length shall be adjusted through deviation order. (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides
Supply and fixed in repairs danger notice plate of size 25 cm x 20 cm x 1.60 mm thick mild steel sheet vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made out of 25 mm x 3 mm MS flat iron including bolts and nuts of requitred size for HT 11000 volts complete all as directed.
Material and labour for complete servicing of VCB Make : ABB installed at 11 KV Sub Station No 1 near (MES Office) by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :- (a) Cleaning of breaker chamber (b) Lubrication of shutter mechanism/moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking healthiness of three poles. (n) Checking of damping device and setting. (o) Tightness, checking of power connection. (p) Checking of breaker ON/OFF operation manually and electrically. (q) Checking of closing timings. (r) Checking of tripping timings. (s) Functional checking of all electrical and mechanical operation of brekers. (t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record. (g) Checking/replacement of non functional strip heaters inside the VCBs and allied works. Note: (i) The breaker shall be repaired through authorised dealer or representative of manufacturer Original Equipment manufacturer representative of Siemens. (ii) Spare parts required for repair of VCB shall be measured and paid under relevant schedule items of this schedule as supply only rates. (iii) After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer -in Charge showing all functional/operational system are working satisfactorily.
Material and labour for complete servicing of VCB Make : Siemens / Areva VCB installed at different location of GE(AF) Bihta station by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :- (a) Cleaning of breaker chamber (b) Lubrication of shutter mechanism/moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the panel. (g) Coiling of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking healthiness of three poles. (n) Checking of damping device and setting. (o) Tightness, checking of power connection. (p) Checking of breaker ON/OFF operation manually and electrically. (q) Checking of closing timings. (r) Checking of tripping timings. (s) Functional checking of all electrical and mechanical operation of brekers. (t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record. (v) Checking/replacement of non functional strip heaters inside the VCBs and allied works. Note: (i) The breaker shall be repaired through authorised dealer or representative of manufacturer Original Equipment manufacturer representative of Siemens. (ii) Spare parts required for repair of VCB shall be measured and paid under relevant schedule items of this schedule. (iii) After completion of repair work, VCB shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer -in Charge showing all functional/operational system are working satisfactorily.
Supply only Spring Drum Cat part No 1VYN300950-20
Supply only Spring Cat part No GCE9478006P0102
Supply only Roller Chain Cat part No 1VYN400950-088
Supply only Curve Washer (RHS) New Cat part No GCE7004135R0101
Supply only Curve Washer (LHS) NEW Cat part No GCE7004136R0101
Supply only Stop Washer Cat part No GCE7006075P0101
Supply only D-Shaft Cat part No 1VYN400950-104
Supply only Cam Disc Cat part No GCE7001923P0101
Supply only Half Shaft Cat part No 1VYN400950-106
Supply only Torsion Spring Cat part No 1VYN400950-006
Supply only Torsion Spring Cat part No 1VYN400950-064
Supply only Counter Cat part No GCE9577554P0100
Supply only Blocking Crank Cat part No GCE7003097P0101
Supply only Blocking Crank Cat part No GCE7003097P0102
Supply only Locking Roller Cat part No 1VYN400950-164
Supply only Sprocket Cat part No 1VYN400950-115
Supply only Latch Cat part No 1VYN400950-116
Supply only Torsion Spring Cat part No 1VYN400950-002
Supply only Charging Lever Cat part No 1VYN400950-114
Supply only Roller Bearing Cat part No 1VYN400950-077
Supply only Torsion Spring Cat part No 1VYN400950-010
Supply only Retaining Washer Cat part No GCE0418316P0100
Supply only Lever Assembly Cat part No 1VYN400901-R
Supply only Torsion Spring Cat part No 1VYN400950-009
Supply only Torsion Spring Cat part No 1VYN400950-004
Supply only Shaft Cat part No 1VYN300950-013
Supply only Control Washer Cat part No GCE7001917P0101
Supply only Compression Spring Cat part No 1VYN400950-001
Supply only Stop Cat part No 1VYN400950-136
Supply only Motor - 220V DC/AC Cat part No 1VYN300951-002 (GCE0940084P0106)
Supply only Motor Cut Off Switch Cat part No HAGT444559P2
Supply only Sprocket Wheel Cat part No 1VYN400950-208
Supply only Torsion Spring Cat part No 1VYN400950-003
Supply only Ratchet Plate Cat part No GCE9478400P0101
Supply only Torsion Spring Cat part No 1VYN400950-005
Supply only Retaining Circlip Cat part No GCE0418205P0100
Supply only On-Off Indicator (Display) Cat part No GCE7001910P0101
Supply only Shaft Cat part No 1VYN300950-030
Supply only Tripping/Closing Coil-110V DC Cat part No 1N54450007-M
Supply only Pin Plug Assembly Cat part No IN26570001-AM
Supply only Emergency Trip Assembly Cat part No IVYN400901-AF
Supply only Connection Piece Cat part No 1VYN400950-204
Supply only Aux. Switch Cat part No 1VYN300950-064
Supply only Contact System For VD4-630 A (12 Finger) Cat Part No. GCE8385888R0102
Supply only Aluminimum Contact Arm Assembly for VD4 CB(800A) Cat part No GCE700142R0119
Supply only Copper Contact Arm Assembly VD4 CB Cat part No GCE7001421R0101
Supply only Contact System For VD4-1250 A(DIA.34 &24 Finger) VD4 Cat part No GCE8385888R0101.
Supply and fix in replacement of unsv/melted sleeved copper bus bar 800Amps for interconnection between siemens -3 Nos breakers + 1 No bus coupler including replacement of suitable size of steel nuts, bolts & washers etc complete all as specified and as directed.
Supply and fix close / open push button assembly complete all as specified and directed.
Supply and fix space heater 0.5kw, 230v AC suitable for VCB alongwith suitable size of thermostat for instant tripping.
Material and labour for complete servicing of RMU Make : ABB installed at various 11 KV Sub Stations at AF Stn Bihta by using required transport including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments complete all as directed by Engr-in-Charge. The serviing covers the following :- (a) Cleaning of breaker chamber (b) Checking of closing and tripping coil (c) Checking of Test/service Aux. switch operation (d) Checking of tripping mechanism operation. (e) Spring charging limit switches operation. (f) Checking healthiness of three poles. (g) Tightness, checking of power connection. (h) Checking of breaker ON/OFF operation manually and electrically. (j) Checking of closing timings. (k) Checking of tripping timings. (l) Functional checking of all electrical and mechanical operation of brekers. (m) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB. Note: The breaker shall be repaired through authorised dealer or the representative of OEM manufacturer of ABB. Location : Sub Stn No 2, ATC Sub Stn, TC P/H Sub Stn & Sub Stn No 5 Note : (a) Spare parts required for repair of RMU shall be measured and paid under relevant items of this schedule at supply only rates. (b) After completion of repair work, RMU shall be connected to full load and testing to be carried out infront of GE (AF) Bihta / Engineer - in - Charge showing all functional/operational system are working satisfactorily.
Supply only Bushing 400 Series Bolted Type Cat part No NHP201699R1 Make : ABB
Supply only O' Ring 72x6 Bushing 400 series bolted Cat Part No NHP402076P15 Make : ABB
Supply only Trip coil safeo force Amplifier Cat No 1VDP000142R1 Make : ABB
Supply only Supply and fix VPIS unit, 9-15 kv type, Cat No YN1V400916-587 Make : ABB
Supply only Supply and fix Relay Make : Ashida Cat No 4200013670
Material and labour for scrapping outer/inner body of VCB/RMU and rusted patch by using super emery paper and remove the dust particles, using any cleaning agent, applying two coats of syntetic enamel paint or spray paint as per latest technology and colour code IEC Standards of 11 KV VCB including re-writing of SM/MES No complete all as specified andas directed.
Supply and fix digital COS₵ Meter ,Make –Conzerv ,C.l-1.0,Aux.Supply- 80-240V AC/DC.
Supply and fix digital Ampere Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.
Supply and fix digital Volt Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.
Supply and fix Numerical O/C & E/F Relay , Aux.Supply- 80-240V AC/DC. CT- 5-1A., Cat part No ADR141C.
Supply and fix VAA 33 Aux.3 Element Relay ,Aux.Supply 30V DC,06 ON Contacts,
Supply and fix VAJH13 Master trip relay ,Make- Alstom, Aux.Supply 30V DC.04 ON Contacts & 01NC Contacts
Supply and fix in replacement of damaged/unsv CT of Ratio – 60/5+5A,VA-7.5VA,5P10,C.l-1.0 Make- NPP,Power Foil,
Supply and fix in replacement of damaged 3 Phase PT of ratio – 11KV/110V ,VA-100,C.l-1.0. suitable for existing model VCB Make- NPP,Power Foil.
Supply and fix Bus bar insulator as per existing size model.suitable for HT 11000 volts.
Supply and filling of transformer oil EHV as per IS 335 of 1993 Part II. Note :- (i) Oil shall be brought in the manufacture sealed contrainer (drum) and shall be kept in safe custody of Engineer-in-Charge. (ii) Contractor shall hand over the purchase voucher and manufacturer's test certificate to the engineer in charge. (iii) Di-electric strength shall not be less than 60 KV AT 2.5 MM GAP
Taking out the sample of transformer oil from bottom of each transformer and HT OCB installed at various locations for checking die electric strength & acidity test of oil and carrying out dehydration (Filtration) of cooling/Insulating oil of HT/LT transformers and HT switch gears through straight line oil filtration plant for removing carbon deposit, extracting moisture content etc. After filtration, the oil shall withstand die electric strength 50 KV within 1 minute with 4 mm Gap. Die electric strength & acidity to be tested before and after filtration and submit the test results all as specified.
B.K. ROY & SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .