Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
14 Apr 2022, 6:00 pmClosed
CHIEF ENGINEER AF NAGPUR
HQ CHIEF ENGINEER AF NAGPUR, VAYUSENA NAGAR 440007
IMPROVEMENT TO HANGAR NO 07 AND 08 AT AIR FORCE STATION KANPUR (PHASE I)
2021_MES_468912_1
AF_CHK_801187
Open Tender
Miscellaneous Works
Item Rate
540 days
KANPUR
For MES Enlisted Contractors - Class A, Category a (i) and b (i) For other contractors Meeting Enlistment Criteria of MES for Class A, Category a (i) and b (i)
9 documents required · 9 mandatory
₹2,000
GE (AF) E/M CHAKERI
₹5.0 L
Yes
17 Jun 2022
3 Sept 2021
21 Apr 2022
3 Sept 2021
14 Apr 2022
31 Mar 2022
6 Sept 2021 - 16 Sept 2021
Amount
EXCAVATION AND EARTH WORK
Excavating in post holes or similar holes, each not exceeding 0.5 Cum, getting out in hard / dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation or for shafts,wells,cesspits,manhole,pier holes,etc. not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed
Returning ,filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed
Removing excavated material exceeding 1.5 Km but not exc 5 Km and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Removing of debris or dumped building materials from tech area to out of the MD land upto a total distance 5 km (minimum) complete all as specified and as directed.
Material and Labour for hardcore of broken Stones of gauge n exc 63 mm, deposited spreaded , levelled in layers n exc 15 cm thick watered and rammed to true surface complete all as specified and as directed.
CONCRETE WORK
Material and Labour for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation ,filling and mass concrete complete all as specified and directed
Material and Labour for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in bed block for fixing of structural angle iron post or any other similar work complete all as specified and directed
Material and Labour for PCC type B1 (1:2:4) using 20 mm graded stone aggregate in copings / benchings, string courses and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
Material and Labour for precast RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in manhole cover / drain covers set in CM 1:6 etc complete all as specified and as directed.
Material and Labour for RCC M-25 design mix for foundation beams,plinth beams,bases of columnsetc.basement slabs, under- reamed piles and mass concrete complete all as specified and as directed.
BRICKWORK
Material and Labour for brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
STONE MASONRY WORK
Material and Labour for 16 mm thick granite (of any type) work (table rubbed and polished) in steps jambs, pillars, window -cills cooking platforms and like over 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting and moulding edges complete all as specified and directed.
WOOD WORK
Material and labour for formwork to sides of concrete foundations ,footings,bases of columns,raft and raft beams,sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
JOINERY WORK
Supply and Fix solid PVC wall lining consisting of 5 mm thick single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and as directed.
Supply and Fix 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and as directed.
Supply and fix 40 mm thick insulated PVC wall lining consisting of PVC insulated panels having expanded polystyrene (EPS) having density not less than 25 Kg/Cum stuck to 2mm thick single side prelam PVC sheet duly fitted into the MS frame work.Strips of 5mm thick PVC sheet of width 75 mm feathered at the edges shall be stuck at places where two panels are joined,so as to cover the screws of both the panels using solvent cement 90 degree heat bent strips of 5mm thick PVC sheets of width 75 mmx75mm feathered at the edges shall be stuck at wall joints/pillars etc. as per specifications complete all as specified and as directed.
BUILDERS HARDWARE WORK
Supply and Fix Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
STEEL, ALUMINIUM AND IRON WORK
Supply and Fix mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary and similar work confirming Fe- 290 Grade E-165 complete all as specified and directed
Ditto all as per item 19 above but fixing only using old serviceable mild steel bracket complete all as specified and directed
Supply and Fix Mild steel wind ties or similar work for roof including securing bolts, posts including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed
Supply and Fix mild steel work in support for rain water pipe, hooks, heavy pintle hinges, large hasp hinges, staples , holdfasts, wall tie etc. and similar work confirming to Fe- 290 Grade E-165 complete all as specified and directed
Supply and Fix structural steel work in channel, angle or tee sections fixed independently with connecting plates/welding etc., confirming to Fe 410 - W(Grade E-250 quality A) complete all as specified and as directed.
Supply and Fix rolled mild steel roof trusses (framed), trussed post, purlins, rails and fastenings and heavy bracket framing, beam,tee,angle,channel or flat sections confirming to Fe 410 - W(Grade E-250 quality B) including distance pieces, cleats, etc., complete all as specified and as directed.
Supply and Fix rolled MS plates (plain or chequered) channels, square cut or notched (ordinary or counter sunk), forming holes, with riveted, bolted or welded attachment confirming to Fe 410-W (Grade E-250 quality B) complete all as specified and as directed.
Supply and Fix mild steel bolts purpose made with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut of dia exceeding 20 cm but not exceeding 25 cm and exceeding 30 cm long complete all as specified and as directed.
Supply and Fix mild steel screw bolts 11 to 15 mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or square nut , not exceeding 5 cm long complete all as specified and as directed.
Material and labour for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars 6 to 8mm dia reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia as in stirrups ,spacers and binders complete all as specified and as directed.
Material and Labour for making functional to existing hangar sliding shutter of size exceeding 50 sqm but not exceeding 60 sqm each, by replacing unserviceable ball bearing, shafts(rolling pin),roller correcting/straightening of guide rails etc including greasing for easing of shutter, complete all as specified and directed
Supply and Fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed..
Material and Labour for powder coated aluminium work for two track sliding window with frame of section no20829 &20830 of Jindal or equivalent make. The window shutters shall be of section no 20736 & 20738 of Jindal or equivalent make including supply and fixing 5 mm thick tinted glass, glazing clips, rubber beading alongwith roller, locking arrangement etc as required complete all as specified and as directed.
Supply and Fix powder coated aluminium door with chowkhat /frame made with aluminium section with size 100 x 44 x 2mm thick and shutter of vertical style with section 84x44 x 2mm thick and top /middle / bottom rails of shutter made with 112x44x2mm thick over and including 5mm thick tinted glass panes , including necessary fixing arrangement ,joining cleats, glazing clips, rubber beading ,floor door spring, tower bolts 200mm long ,mortice lock 300 mm ,4 lever, rounded handles etc fixed to shutters complete all as specified and directed
Supply and Fix anodised powder coated aluminium frame for aluminium partition of different standard sections with one or more rebates including jointing cleat for fixing etc. complete all as specified.
ROOF COVERING WORK
Supply and Fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of BMT not less than 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Supply and Fix fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugation side lap fixed with coach screw and washer or self tapping screw in roof, wall etc, all as specified and directed.
Supply and Fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet BMT not less than 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified and directed.
Supply and Fix 0.80mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings with grade of zinc coating 275 all as specified and directed
Supply and Fix eaves gutter of 250 mm dia UPVC half round pipes with including all fittings like clamps , support brackets, rubber gasket, stop end outlet (at both end) and running outlet (at every 5 m interval) to facilitate fixing of 160 mm dia down take pipes complete all as specified and directed
Material and Labour for reinforced elastromeric liquid water proofing compound membrane with resilient acrylic polymers having sun reflectivity Index (SRI) of 105 on top of roof surface in three coats @ 10.76 ltr /10 Sqm. One coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 :1 i.e. 3 part of water proofing liquid and one part of water) and two coats of undiluted elastomeric water proofing liquid. The dry film thickness of complete allocation/ system should not be less than 500 micron complete all as specified and as directed. NOTE: The treatment shall be carried out through authorised representative of manufacturer.
CEILING AND LINING WORK
Material and Labour 16 mm thick of size 600x600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular) including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15mm x 38 mm size (load carrying capacity 14 kg/sqm) spaced at 1200 mm centres securely fixed to the structural soffit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200x 600 mm module, cut sub cross tee/runner 600mm require independent support. Wall angle of size 19mm x 19mm, secured to the periphery of the wall at 450 mm maximum centres. Grid shall be suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia aquiline wire with suitable fasteners and hook clip complete all as specified and as directed.
Material and Labour for 12 mm thick prelaminated particle board, exterior grade prelaminated both side with decorative choice lamination, fixed with anodised aluminium (powder coated) snap beading to aluminium frame work in cup board shutters, partitions, shelves and similar work. Complete all as specified and directed
FLOOR FINISHES AND PAVING WORK
Material and Labour for 5mm thick PU based anti static flooring complete all as specified and directed and as per manufacturer instructions consisting of following steps / stages :- (a) Surface cleaning:- Cleaning of surfaces free from dust, dirt, moisture & all foreign material from the floor. All floor is to be cleaned by means of scrubber. Acid itching, if reqd and water wash is to be done. Then the oil/ grease is to be removed from the floor using Hot compressed air blasting machine. For floor cleaning all mechanized equipments are to be used like scrubbers, sanders, hot blowers, vacuum cleaners, moisture test machine etc. (b) Cutting & filling cracks:- Cutting of existing cracks in ' V- shape' groove (minimum 5cm) by use of diamond cutter to have perfect plane surface without breaking the edges, removing dust by power blower/ compressed air and removing rubbish material outside of MOD land and filling the grooves with epoxy mortar as per manufacturers instructions.
(c) Primer: Providing and applying low viscous epoxy primer having a volumetric ratio of mixing of Resin and Hardener in equal volumes to provide a DFT of around 200 microns. (d) Screed: Providing and applying self levelling screed (epoxy modified mortar) with polymer to aggregate ratio not exceeding 1:4 by trowel to the desired thickness of 2700 microns. The layer is to be desecrated by spike roller to dislodge air pockets. (e) Copper tape GRID : Providing and fixing of 100 microns thick, self adhesive (conductive type) copper tape to ensure quick transfer of charge (Make: 3M or equivalent) including connecting copper wire / tape and earthing etc required to get the desired result. The spacing of copper tape Grid shall be approximately 5 m x 5m C/C both ways. (f)Conductive primer: Providing and applying PU (polyurethane) based conductive coat having a volumetric ratio of resin and hardener in 4:1 to yield a DFT of 100 microns. (g) Self levelling course of PU (polyurethane) top coat : Providing and applying PU based conductive self levelling top coat (high gloss, chemical resistant and light reflective) containing antistats to yield a thickness of 2000 micrones and surfaces resistivity which will not exc 10⁹ Ohms. The cured surface shall be tested with Mega ohm meter as per ASTM F-150 to check the readings as per the design. (h) Joints ( Construction/Expansion/Dummy):- Raking out old decayed/damaged existing sealing compound from the joints of any size and cleaning the joints thoroughly by removing dust, dirt, foreign material etc, and making good the existing damaged joints edges on each side of joints in cement concrete floor by cutting around to true vertical surface by using diamond cutter etc and removing the debris and other foreign materials outside MD land including necessary preparation of surface by cleaning the sides and bottom of surface of joints by using compressed air, and applying epoxy primer and fill the joints with using polyurethane sealant ( single component) of approved make with colour matching to the pu floor complete all as specified and directed.
Material and labour for preparation of new PU antistatic floor surface/ steel surfaces and marking of lines, dashes, arrows, letters etc with two coats of polyurethane based paint of approved shade with surface primed using epoxy based solvent free compound all as per manufacturer's instruction complete all as specified and as directed.
Roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
Brushing neat cement slurry with 3 Kg., of cement per square metre complete all as specified and directed.
Material and Labour for vitrified light shade tiles 10 mm thick (square/rectangular) polished, area of each tiles exc 0.42 Sqm but n exc 1.0 sqm in floors etc. set and and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer of cement mortar (1:6) finished even and rough to receive the top layer complete all as specified and directed..
Ditto all as per item no 47 above but as in skirting over 10mm thick cement plaster (1:4) complete all as specified and directed..
Material and Labour for 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection/path/ hard standing surface finished fair & even without using extra cement complete all as specified and directed...
Material and Labour for 40 mm thick cement concrete type B 2, 1:2:4 (using 20 mm graded granite stone aggregate) in sub base of flooring/ hard standing finished surfaces even and fair complete all as specified directed
Material and Labour for machine cut kota stone slab flooring 20-25mm thick over 15 mm cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Material and Labour for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm cement rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed
Material and Labour for plain cement concrete Type C-1, 1:3:6 (using 20 mm graded granite stone aggregate)as in sub base all complete all as specified and directed
Material and Labour for 75 mm thick cement concrete 1:3:6 type C-2 (using 40mm graded stone agg) as in flooring/plinth protection/sub-base finishing concrete surface even and smooth without using extra cement complete all as specified and directed.
PLASTERING AND POINTING WORK
Material and Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM (1:6) on wall , finished even & smooth without using extra cement complete all as specified and directed..
Material and Labour for two coat plaster 35mm thick (20mm+15mm ) on rough concrete surface on fin, facia, chajja and similar article in cm 1:3 finished even and smooth without using extra cement in any height including necessary scaffolding complete all as specified & directed.
WHITE WASHING, COLOUR WASHING AND DISTEMPERING WORK
Material and Labour for complete removal of existing treatment on wall surfaces complete all as specified directed.
Material and Labour for preparation of old surfaces of walls and applying two coat of Oil Bound Distemper over a coat of primer over 1mm thick wall care putty complete all as specified and directed.
Material and Labour for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed.
GLAZING WORK
Supply and Fix 5.5 mm thick frosted sheet glass, ordinary quality and glazing with wooden beading exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and Fix 5 mm thick tinted glass fixed with rubber beading and aluminium (powder coated) snap beads to aluminium framework in squares / rectangle exceeding 0.5 sqm in each pane complete all as specified and as directed.
PAINTING WORK
Material and Labour for preparation of old painted steel and iron surfaces of any description over 10cm in girth or width not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
Material and Labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
WATER SUPPLY, PLUMBING, DRAINS AND SANITARY APPLIANCES WORK
Supply and Fix PVC SWR pipes 160 mm bore single socketed in any length of pressure rating 4 Kg/Sqcm with or without rubber ring joints fixed to hanger walls complete all as directed.
Supply and Fix PVC SWR bend/shoe of any radius for 160 mm dia complete all as specified and directed.
Supply and fix 20 mm bore galvanised iron tubing light grade with all fittings laid in trenches complete all as specified and directed
Supply and fix 15 mm bore galvanised iron tubing light grade with all fittings laid in trenches complete all as specified and directed
Supply and fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable of size 80mm bore complete all as specified and directed
Supply and fix 40 mm bore galvanised iron tubing light grade with all fittings laid in trenches complete all as specified and directed
ELECTRIFICATION WORKS
Material and Labour for high bay light wiring on celling /roof / trusses with necessary fixing arrangement for 3 core PVC insulated sheathed armoured stranded copper conductor cable of size 2.5 sqmm 1100 volt grade and PVC insulated 3 way brass connector of 6 amps to be provided for each high bay fittings including necessary fixing arrangement of cable with MS strip not less than 20x2.5 mm with suitable nut bolt and washer duly painted with aluminium paint over red oxide primer by maintaining distance not more than one meter & six light controlled by one modular switch complete all as specified and directed. Note:- (i) The cost of PVC insulated brass connector 3 way with 2 mm thick ms enclosed box for each fitting shall be inclusive in quoted rate (iii) The cost of ms plate shall be inclusive in quoted rate (iv) Six light shall be controlled by one 10 Amps modular switch flush mounted , 240 volts AC supply and paid under relevant item of schedule "A" .
Supply and Fix modular switch 10 Amps , one way , 240 volts , 50 Hz AC supply complete with metal flush box for 2 module with cover plate complete .
Material and Labour for concealed point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, fittings etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting and chasing of wall and making good disturbed surface to match with the existing surface complete all as specified and directed, for one light / fan point controlled by one modular switch .
Material and Labour for concealed point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, fittings etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting and chasing of wall and making good disturbed surface to match with the existing surface complete all as specified and directed, for one 6 amps socket point on independent board
Material and Labour for concealed point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, fittings etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting and chasing of wall and making good disturbed surface to match with the existing surface complete all as specified and directed, for one 6 amps socket point on same board
Material and Labour for concealed power point wiring on wall and surface on ceiling / roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 2.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, fittings etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 2.5 Sqmm, 1100 volts grade for continuous earthing including cutting and chasing of wall and making good disturbed surface to match with the existing surface complete all as specified and directed, for one 6/16 amps modular socket point on independent board
Material and Labour for modular switch flush type , one way ,6 Amp, 240 volts , AC supply 1 module complete all as specified.
Material and Labour for modular switch flush type , one way 16 Amp,240 volts , AC supply, 1 module complete all as specified.
Material and Labour for modular sockets flush type 6 Amp, 2/3 pin, 240 volts , AC supply ,2 module complete all as specified.
Material and Labour for modular sockets flush type 6 /16 Amp, 2/3 pin, 240 volts , AC supply ,2 module complete all as specified.
Supply and Fix ceiling rose , polycarbonate insulated body with three terminals, 6 amps , 230 volts complete.
Supply and Fix sheet metal enclosure, 20 amp single pole & neutral with a two pin and earth plug and socket complete in metal clad board (industrial type) with one single pole MCB 20 amp fixed properly on the concealed position all as directed
Supply and Fix double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
Supply and Fix double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
Supply and Fix factory made double door epoxy powder coated distribution board TPN 8 ways (TPN, MCCB, Vertical DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall/ on angle iron frame and suitable for universal mounting and including 200 amp copper busbar, neutral bar, standard DIN rail, earth bar and cable ties for cable management top and bottom removal gland plates with knockout and suitable for one 4 pole MCCB 100 Amps as incomer and SP/TPN MCBs as outgoing complete all as specified and directed.
Supply and Fix MCB SP 6 Amp to 32 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
Supply and Fix MCB SPN 20 to 32 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
Supply and Fix MCB SPN 40 to 63 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
Supply and Fix MCB TPN 20 to 32 amps, 415 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs. complete all as specified and directed.
Supply and Fix MCB TPN 40 to 63 amps, 415 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
Supply and Fix MCCB 4pole, 415 Volt grade, AC 100 Amps, 25KA and Ics =100% Icu with adjustable thermal release complete all as specified and directed.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm alongwith 4 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid metallic MS conduit 16 SWG, ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends ,and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : (i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate. (ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm alongwith 6 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid metallic MS conduit 16 SWG, ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends ,and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : (i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate. (ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm alongwith 10 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid metallic MS conduit 16 SWG, ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends ,and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : (i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate. (ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm alongwith 2 No ,10 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid metallic MS conduit 16 SWG, ISI marked not less than 32mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : (i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate. (ii) Four single core cable and two run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm alongwith 4 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : (i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate.(ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm alongwith 6 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete. Note : ( i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate.(ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for concealed sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm alongwith 10 sqmm multi stranded copper conductor as a continuous earth wire complete drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 20mm dia with all fitting such as tee, bands, reducer, elbow, bell mouth, tube ends and all fixing accessories such as coupler lock, nuts, saddles, pipe, hooks etc fixed properly complete Note : ( i) Cutting &chiselling of wall including plastering of wall and making good disturbed surface shall be included in the item rate.(ii) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.
Material and Labour for servicing, painting and refixing of Air Circulator fan retrieve from item No 153 here in after complete all as specified.
Fixing only Ceiling fan after complete cleaning of all dust,one coat of painting of ceiling fan complete with synthetic enamelled paint by spraying including filling cavities with filler ,writing MES No on ceiling fan and connecting including provision of cable from ceiling rose to fan connector all as directed
Material and Labour for wall mounted LT distribution box, indoor type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and wall legs of angle iron, front openable,having 415V, three phase with neutral , bus bar of capacity 200 Amp made out of aluminium strip fixed on porcelain insulator with nut, bolts and fiber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(a) MCCB 4 Pole , 200 Amps , 25 KA , 415 volts , 50 Hz AC supply - 1 No ( Incomer ) Ics=100% Icu
(b) Single pole & Neutral with a two pin and earth plug and socket 32 amp complete with one single pole 32 amp MCB. - 06 Nos
(c) Three pole & Neutral with a three pin and earth plug and socket 63 amp complete with one triple pole 63 amp MCB. - 02 Nos
Supply and fixing recess mounted LED lightening fitting of capacity 36 watt ,environmental friendly high energy efficient with electronic driver suitable for working on 240 volts, 50 Hz AC supply. System Efficacy 110 lm / watt , rated system of 50.000 burning hours, colour temperature of 5500 to 6500 k, CRI> 70, THD<10% ,power factor 0.95 with IP rating IP20 ,housing made out from metallic CRCA powder coated, cover with high efficiency diffuser , ,complete with 0.5 sq mm pvc insulated multistranded copper wire cable 3 core to be connected with the ceiling rose complete with hanging/fixing arrangements with all accessories all as specified and directed
Supply and fix LED high bay/ medium bay luminaries , energy saving , environment friendly , robust open type with high power COB LED as light source complete with mounting arrangement such as chain flat iron/angle iron/MS rod or any other suitable materials as per site requirement duly fixed in roof/girder/channel , fitting of capacity 100 watt , working on 230 volts , 50 Hz AC supply with minimum system lumen output 9000 lumens and minimum system efficiency of 100 lumens/ Watt, rated system of 50.000 burning hours, colour temperature of 5500 to 6500 k, CRI> 70, with IP-54 rating with THD<10% and P.F >0.95. The luminaries housing should be made of extruded high pressure die cast aluminium for efficient thermal management, sturdiness , excellent corrosion resistance finish with epoxy black powder coated housing with aluminium spun reflector sand blast from inside and electrochemically brightened glass lens over COB for uniform distribution with sealed toughened glass, powered by an in built electronic driver (SMPSbased constant current supply), total power consumption including driver should not exceed 100 watt complete all as directed
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI wire 4 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 15 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth wire /protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Supply and Fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4.00mm dia galvanised iron or steel wire.
Supply and Fix Air termination, single pointed aluminium rod 12mm dia and 900mm long complete all as directed
Supply and Fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw complete all as directed
Supply and Fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed
Material and Labour for shifting of existing LT panel from one location to another location of any capacity and size. Panel shall have fixed on new platform with PCC (1:4:8) type D-2 using 40mm graded stone crushed stone aggregate 15cm thick in foundation, bricks, masonry in CM (1:6) and 15mm thick rendering in CM (1:6) on exposed surfaces and 100mm thick PCC padding (1:3:6) type C-1 on top and grouting bolts etc for panel including necessary connection complete. The platform shall be 45cm height from the nearest road level all as directed
NOTE : The quoted rate shall be inclusive of dismantling LT panel /pole , removal of PCC and reusing if required and making good the disturbed location of LT panel.
Material and Labour for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e. bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply, Laying, jointing, testing and commissioning LT XLPE/ PVC cables, PVC insulated, PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc complete of following sizes :-
(a) 3.5 core 630 sqmm
(b) 3.5 core 400 sqmm
(c) 3.5 core 300 sqmm
(d) 3.5 core 240 sqmm
(e) 3.5 core 95 sqmm
(f) 3.5 core 70 sqmm
(g) 3.5 core 35 sqmm
(h) 4 core 25 sqmm
(i) 4 core 16 sqmm
(j) 2 core 10 sqmm
Note:- The rate of saddles for cable fixing in wall, termination and connecting of cable including providing suitable size and nos of lugs by crimping as directed and specified shall be deemed to be included in the item rate.
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear open able, 440V, 3Ph, 4 wire having bus bar of capacity 1200 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fiber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-(Panel 12 &15)
(A) Incoming
(a) Air circuit breaker 800A four pole manual draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 690V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No Ics=100% Icu
(b) Bus bar (copper strip) 1200 Amp, three phase and half neutral, not less than 30cm long mounted on insulators for incoming supply - 01 No.
(d) Digital multifunctional meter - 01 No.
(e) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 315Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.
(b) MCCB 250Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 02 Nos.
(c) MCCB 100A, 4 Pole, 415V,16KA rupturing capacity, with adjustable thermal magnetic release - 04 No
Supply and Fix ON Load Change over switch having capacity 2000 Amp, 4 pole, 415 Volts with suitable enclosure made out of 3.15mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron complete all as directed
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 2000 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) Air circuit breaker 1250 A four pole manual draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No Ics=100% Icu
(b) Bus bar (copper strip) 2000 Amp, three phase and half neutral, not less than 30cm long mounted on insulators for incoming supply - 01 No.
(d) Digital multifunctional meter - 01 No.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 400 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 04 Nos.
(b) MCCB 200 A, 4 Pole, 415V, 36KA repturing capacity, with adjustable thermal magnetic release - 02No
(b) MCCB 160A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 01 No (spare)
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity1600 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) Air circuit breaker 1000 A four pole manual draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No Ics=100% Icu
(b) Bus bar (copper strip) 1600 Amp, three phase and half neutral, not less than 30cm long mounted on insulators for incoming supply - 01 No.
(d) Digital multifunctional meter - 01 No.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 315 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.
(b) MCCB 250 A, 4 Pole, 415V, 36KA rupturing capacity, with adjustable thermal magnetic release - 02 No
(b) MCCB 200A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 03 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 500 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 315 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.Ics=100% Icu
(b) Bus bar (copper strip) 500Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 250 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
(b) MCCB 63A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 02 No
c)MCCB25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
d) MCCB 16 A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 300 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 200 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos. Ics=100% Icu
(b) Bus bar (copper strip) 300Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 100 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
(b) MCCB 63A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 01No
c)MCCB 32A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 04 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 400 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 250 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.Ics=100% Icu
(b) Bus bar (copper strip) 400Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB125 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
(b) MCCB 63A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 03No
c)MCCB 32A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
c)MCCB 25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 600 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-(Panel 3 &5)
(A) Incoming
(a) MCCB 400 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.Ics=100% Icu
(b) Bus bar (copper strip) 600Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB315 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
(b) MCCB 63A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 02No
c)MCCB 25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 03 No
d)MCCB 16A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 600 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 400 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos Ics=100% Icu .
(b) Bus bar (copper strip) 600Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB 315 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
b)MCCB 25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 03 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 500 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 315 Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.Ics=100% Icu
(b) Bus bar (copper strip) 500Amp, three phase and neutral , not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 set.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(a) MCCB200 Amps, 4 Pole, 415V , 25KA rupturing capacity, with adjustable thermal magnetic release - 01Nos.
c)MCCB 63A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 03 No
c)MCCB 25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 03 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 400 Amp made out of aluminium strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 250Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos.Ics=100% Icu
(b) Bus bar (aluminium strip) 400Amp, 4 pole, not less than 30cm long mounted on insulators for incoming supply - 01 No.
(d) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(b) MCCB 160A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 02 No
(b) MCCB 100A, 4 Pole, 415V, 25KA rupturing capacity, with adjustable thermal magnetic release - 01 No
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 600 Amp made out of aluminium strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) MCCB 400Amps, 4 Pole, 415V , 36KA rupturing capacity, with adjustable thermal magnetic release - 01 Nos. Ics=100% Icu
(c) Bus bar (aluminium strip) 600Amp, 4 pole, not less than 30cm long mounted on insulators for incoming supply - 01 No.
(e) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
(b) MCCB 100A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 01 No
(c) MCCB 63A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 06 Nos
Labour for laying serviceable LT cable retrieve from item No 158 and 159 here in after complete all as specified.
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity 6000 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-
(A) Incoming
(a) Air circuit breaker 4000 A four pole Electrical draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=70 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No Ics=100% Icu
(b) Bus bar (Copper strip) 6000 Amp, three phase and half neutral, not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 No.
(d) Digital multifunctional meter - 01 No.
(e) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
a)Air circuit breaker 1250 A four pole Electrical draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No
b)Air circuit breaker 1000 A four pole Electrical draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No
(c)Air circuit breaker 800 A four pole Electrical draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No
(b) MCCB 400A, 4 Pole, 415V, 36KA rupturing capacity, with adjustable thermal magnetic release - 01 No (spare)
(C) MCCB 250A, 4 Pole, 415V, 36KA rupturing capacity, with adjustable thermal magnetic release - 02 No (spare)
Material and Labour for LT feeder pillar box indoor, compartmentalised type, made out of 2mm thick, CRCA sheet totally enclosed, weather, dust & vermin proof, epoxy powder coated over a coat of zinc chrome primer, CPRI approved, factory made, confirming IP-54 having locking arrangement of suitable size to accommodate all accessories with support of angle iron of size 50 x 50 x 6mm to cover all corner and standing legs of angle iron, front and rear openable, 440V, 3Ph, 4 wire having bus bar of capacity1200 Amp made out of copper strip fixed on porcelain insulator with nut, bolts and fibber separator in between bus bar duly insulated with coloured sleeves, internal wiring with suitable copper cable including installing, testing, commissioning complete with all fitting, new panel fitted by providing following fitments/ accessories :-(Panel 13&14)
(A) Incoming
(a) Air circuit breaker 800A four pole Electrical draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 1100V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No Ics=100% Icu
(b) Bus bar (Copper strip)1200 Amp, three phase and half neutral, not less than 30cm long mounted on insulators for incoming & outgoing supply - 01 No.
(d) Digital multifunctional meter - 01 No.
(e) Neon indicating lamps (R, Y & B) -01 Set.
(B) Outgoing
a) MCCB 500A, 4 Pole, 415V, 36KA rupturing capacity, with adjustable thermal magnetic release- 1No
b)MCCB 400A, 4 Pole, 415V, 36KA rupturing capacity, with adjustable thermal magnetic release- 02 No
(c) MCCB 100A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No (spare)
(c) MCCB25A, 4 Pole, 415V, 16KA rupturing capacity, with adjustable thermal magnetic release - 02 No
Supply install testing and commissioning of APFC Panel of capacity 250 KVAR Company make Automatic power factor improvement system of 3-phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S Sheet and M.S Angle Iron 40 x 40 x 6mm frame, duly powder coated, front & back open able with locking arrangement to facilitate easy maintenance, heavy Cable entry gland provision for hooks on top for mounting panel in Platform. Complete Capacitor and Reactor Filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel, during the maintenance / replacement. Necessary internal connection with proper single core, PVC insulated, multistranded copper wire of adequate size, 650 Volts grade copper wire rating & lugs.
INDICATION: Phase indication for RYB and bank On + OFF display
APFC CONTROLLER: Controller should be of 12 Stage advanced with digital signal processor for fast thyristor switching, Dual PF Mode, Com. Port- 485, programmable discharge time, alarm option on Over voltage, harmonics, display capacitive, inductive, normal position of the system. It should have clearly visible 3 window LED display to display the each phase data ( 38 parameters minimum) separately. In order to have complete system and network control, it should have 7 input channels, 4 voltage and 3 main network current. It should be capable of recording Kwh and calculating harmonics up to 19th level on all phase , sensing current from 3 CT’s for all 3 phase parameters.
The system should be capable of measuring and displaying following parameters for each phase: current, Voltage, Power Factor, Active Power, Reactive Power, Apparent power, THD-I (%), THD-V (%), Individual Harmonics up to 19th , Current and Voltage Harmonics up to 19th, Active Energy (KWH), Reactive Energy (KVARH), Equivalent 3 phase Active Power, Equivalent, 3 phase Reactive Power, Equivalent 3 phase Apparent Power
AXIAL FLOW FAN with thermostat on the Top with MCB Protection
BUS-BARS - 400 amps TP Copper bus bars
SMPS POWER SUPPLY: 24 V, 9A SMPS power Supply for TSM Firing with protection on incoming & Outgoing
INCOMER : 400 Amp TP,MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics =Icu, 36 KA
Low tension current transformer, cast rasin in shape of ratio 400/5 Amp, class accuracy 03.3 complete-03 Nos
OUTGOING ( BANK PROTECTION)
HRC Fuse Link with Fuse Base:
Bank - I - 3 nos of 12A HRC Fuse Link in 32A Fuse base
Bank - II - 3 nos of 25A HRC Fuse Links in 32A Fuse Base
Bank - III - 3 nos of 25A HRC Fuse Links in 32A Fuse Base
Bank - IV – 3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank - V –3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VI –3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VII – 3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VIII –3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank – IX –3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank – X–3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank – XI –3 nos of 40A HRC Fuse Links in 63A Fuse Base
Glass fuse links 2A, with base for Thyrister module Protection
THYRISTOR MODULE – Electronic Thyristor Switching Module( Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink , firing card and axial fan for its cooling operation
Bank - I - 1 no of 15Kvar
Bank - II - 1 no of 15Kvar
Bank - III – 1 no of 20Kvar
Bank - IV – 1 no of 25Kvar
Bank – V – 1 no of 25Kvar
Bank –VI – 1 no of 25Kvar
Bank –VII – 1 no of 25KVar
Bank – VIII – 1 no of 25Kvar
Bank – IX – 1 no of 25Kvar
Bank – X – 1 no of 25Kvar
Bank – XI – 1 no of 25Kvar
CAPACITORS: Capacitor should be Super Heavy Duty( MDXL) with 525V, 50Hz capable of withstanding current up to 4xIn and temperature withstanding up to 70 deg C temperature on its surface without any detoriation in its lifespan
Bank - I - 1 no of 15Kvar
Bank - II - 1 no of 15Kvar
Bank - III – 1 no of 20Kvar
Bank - IV – 1 no of 25Kvar
Bank – V – 1 no of 25Kvar
Bank –VI – 1 no of 25Kvar
Bank –VII – 1 no of 25KVar
Bank – VIII – 1 no of 25Kvar
Bank – IX – 1 no of 25Kvar
Bank – X – 1 no of 25Kvar
Bank – XI – 1 no of 25Kvar
Supply install testing and commissioning of APFC Panel of capacity 200 KVAR Company make Automatic power factor improvement system of 3-phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S Sheet and M.S Angle Iron 40 x 40 x 6mm frame, duly powder coated, front & back open able with locking arrangement to facilitate easy maintenance, heavy Cable entry gland provision for hooks on top for mounting panel in Platform. Complete Capacitor and Reactor Filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel, during the maintenance / replacement. Necessary internal connection with proper single core, PVC insulated, multistranded copper wire of adequate size, 650 Volts grade copper wire rating & lugs.
INDICATION: Phase indication for RYB and bank On + OFF display
APFC CONTROLLER: Controller should be of 12 Stage advanced with digital signal processor for fast thyristor switching, Dual PF Mode, Com. Port- 485, programmable discharge time, alarm option on Over voltage, harmonics, display capacitive, inductive, normal position of the system. It should have clearly visible 3 window LED display to display the each phase data ( 38 parameters minimum) separately. In order to have complete system and network control, it should have 7 input channels, 4 voltage and 3 main network current. It should be capable of recording Kwh and calculating harmonics up to 19th level on all phase , sensing current from 3 CT’s for all 3 phase parameters.
The system should be capable of measuring and displaying following parameters for each phase: current, Voltage, Power Factor, Active Power, Reactive Power, Apparent power, THD-I (%), THD-V (%), Individual Harmonics up to 19th , Current and Voltage Harmonics up to 19th, Active Energy (KWH), Reactive Energy (KVARH), Equivalent 3 phase Active Power, Equivalent, 3 phase Reactive Power, Equivalent 3 phase Apparent Power
AXIAL FLOW FAN with thermostat on the Top with MCB Protection
BUS-BARS - 400 amps TP Copper bus bars
SMPS POWER SUPPLY: 24 V, 9A SMPS power Supply for TSM Firing with protection on incoming & Outgoing
INCOMER : 315 Amp TP,MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics =Icu, 36 KA MAKE -
Low tension current transformer, cast rasin in shape of ratio 400/5 Amp, class accuracy 03.3 complete-03 Nos
OUTGOING ( BANK PROTECTION)
HRC Fuse Link with Fuse Base:
Bank - I - 3 nos of 12A HRC Fuse Link in 32A Fuse base
Bank - II - 3 nos of 25A HRC Fuse Links in 32A Fuse Base
Bank - III - 3 nos of 25A HRC Fuse Links in 32A Fuse Base
Bank - IV – 3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank - V –3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VI –3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VII – 3 nos of 50A HRC Fuse Links in 63A Fuse Base
Bank – VIII –3 nos of 40A HRC Fuse Links in 63A Fuse Base
Bank – IX –3 nos of 40A HRC Fuse Links in 63A Fuse Base
Glass fuse links 2A, with base for Thyrister module Protection
THYRISTOR MODULE – Electronic Thyristor Switching Module( Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink , firing card and axial fan for its cooling operation
Bank - I - 1 no of 15Kvar
Bank - II - 1 no of 15Kvar
Bank - III – 1 no of 20Kvar
Bank - IV – 1 no of 25Kvar
Bank – V – 1 no of 25Kvar
Bank –VI – 1 no of 25Kvar
Bank –VII – 1 no of 25KVar
Bank – VIII – 1 no of 25Kvar
Bank – IX – 1 no of 25Kvar
CAPACITORS: Capacitor should be Super Heavy Duty( MDXL) with 525V, 50Hz capable of withstanding current up to 4 x In and temperature withstanding up to 70 deg C temperature on its surface without any detoriation in its life span
Bank - I - 1 no of 15Kvar
Bank - II - 1 no of 15Kvar
Bank - III – 1 no of 20Kvar
Bank - IV – 1 no of 25Kvar
Bank – V – 1 no of 25Kvar
Bank –VI – 1 no of 25Kvar
Bank –VII – 1 no of 25KVar
Bank – VIII – 1 no of 25Kvar
Bank – IX – 1 no of 25Kvar
(i) The APFC panel and all connected items mentioned shall be of the same make.
(ii) The equipment offered shall be complete in all respects. Any material and components not specifically stated in this specification but which is necessary for trouble free operation of the equipment and accessories specified in this specification, shall be deemed to be included unless specifically excluded. The equipment shall conform in all respects to high standards of engineering design and workmanship and shall be capable of performing in continuous operation.
Supply and Fix superior quality fine finishing reliable hot dip galvanized mild steel cable tray of size not less than width 300mm, height 150mm , 2 mm thick and fixed on angle iron support including suitable size of cable saddles for fixing of cable complete all as specified and as directed.
Material and Labour of MS Angle of size 50x5mm thick, fabricated as required including grouting, welding and flat iron clamp with bolts, nuts & washers drilling for bolts in any shape or size as indicated or directed and including painting with one coat of red oxide primer and two coats of approved paint before fixings and and one coat of approved paint after fixing complete all as specified and as directed
Material and Labour for earth continuity or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or other any indicated situation for loop earthing etc as required 32 x 6mm galvanised iron strip complete all as specified and as directed.
Material and labour for earthing complete with copper earth plate electrode 600 mm X 600 mm X 3 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to copper strip of size 20x3 mm main earthing lead by means of copper bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8 mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 25 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required copper strip of size 20x3 mm all as specified and directed.
DEMOLITION/DISMANTLING/TAKING DOWN
Dismantling floor, hearth or wall tiling ( Glazed tiles, cement concrete tiles, terrazzo tiles )including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of cement concrete ( un-reinforced ) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed
Taking down / removing of PVC floor tiles of any description complete all as specified.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc., including making good breakages in taking out and handling; removing to store or stacking to reuse.
Dismantling plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed.
Demolition of Brick work / stone masonry built in cement mortar complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for all as specified and directed..
Taking down eaves, gutters and rain water pipes including all fittings any size and pattern complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets.
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
Taking down/removing of existing water proofing treatment on roof surfaces and wall surfaces complete, including screed bed, racking out joints, hacking for key scrubbing down with water etc., and removing rubbish out of MD land all as specified and as directed.
Taking down steel glazed ventilator chowkats or frames of not exc 1.5 sqm each from sheet wall cladding all as directed.
Taking down steel/wooden chowkats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame), all as directed.
Taking down wooden chowkats or frames exc 1.5 sqm but not exceeding 4.0 sqm each with shutters (without taking off shutters from the frame), all as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putty or white / colour wash all as required and directed
Taking down main switch/DB/AC box of any capacity including fixing accessories complete all as specified and directed.
Taking down old unserviceable tube light fitting of any capacity and rating complete all as specified and directed.
Taking down old unserviceable Highbay light fitting of any capacity and rating complete all as specified and directed.
Taking down old unserviceable ceilling/wall/ exhaust fan of any capacity and rating and deposit in MES store yard complete all as specified and directed.
Taking down old unserviceable sub main wiring of single phase of size 4 , 6 & 10 sq mm complete single phase .
Taking down old unserviceable sub main wiring of 3 phase of size 10 sq mm complete
Dismantling old existing LT panels of any type/size.
Dismantling old existing MS channel or angle iron complete
Taking down/ getting out carefully old serviceable/ unserviceable LT under ground cable from trench/duct or fixed on walls or laid in duct/ pipe and kept in safe custody for reuse of serviceable UG cable of size185 to 400 Sqmm, 3.5 core cable complete all as specified and directed .
Taking down/ getting out carefully old serviceable/ unserviceable LT under ground cable from trench/duct or fixed on walls or laid in duct/ pipe and kept in safe custody for reuse of serviceable UG cable of size 25 to 150 Sqmm, 3.5/4 core cable complete all as specified and directed.
M.S CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .