| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.3 L+₹4,874 (0.52%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹11.4 L+₹2.1 L (22.3%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
5 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (U)
AGE (I) CIF (U)
REPAIR TO LT NETWORK FOR HQ CIF(U) UNDER AGE (I) CIF(U)
2020_MES_401735_1
AGE(I)CIF(U)-30/2020-21
Open Tender
Civil Works
Item Rate
180 days
AGE (I) CIF (U)
As per NIT
9 documents required · 9 mandatory
₹500
AGE (I) CIF (U)
₹20,000
Yes
9 Mar 2021
8 Dec 2020
7 Jan 2021
8 Dec 2020
5 Jan 2021
23 Dec 2020
60 days
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for laying of cable or pipes, trimming the sides, forming bottom surfaces to required leve, n.exc 10sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed.
M&L for dry sand cushioning to under ground cable 8cm thick before laying the cable and 15cm thick after laying the streching the cable in trenches, including hand punning and consolidating complete all as specified. Note : for payment purpose punned thickness shall be measured.
M&L for sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete, all as specified and directed.
Supply & laying in replacement of cable of size 10 sqmm 2 core, 1100 volts grade XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor laid in trenches or passing through pipes with suitable cable gland and aluminium lugs of required sizes and testing after laying, including taking up old unserviceable cable, complete all as specified and directed. Make:- Universal/Plaza/Gloster/Havells/Nicco.
Supply & laying in replacement of cable of size 16 sqmm 4 core, 1100 volts grade XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor laid in trenches or passing through pipes with suitable cable gland and aluminium lugs of required sizes and testing after laying, including taking up old unserviceable cable, complete all as specified and directed. Make:- Universal/Plaza/Gloster/Havells/Nicco.
Supply & laying in replacement of cable of size 35 sqmm 3.5 core, 1100 volts grade XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor laid in trenches or passing through pipes with suitable cable gland and aluminium lugs of required sizes and testing after laying, including taking up old unserviceable cable, complete all as specified and directed. Make:- Universal/Plaza/Gloster/Havells/Nicco.
Supply & laying in replacement of cable of size 50 sqmm 3.5 core, 1100 volts grade XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor laid in trenches or passing through pipes with suitable cable gland and aluminium lugs of required sizes and testing after laying, including taking up old unserviceable cable, complete all as specified and directed. Make:- Universal/Plaza/Gloster/Havells/Nicco.
S&F in replacement of GI tubes light grade of 50 mm bore with all fitting for cable protection trenches / wall / on pole including sealing of pipe openings with ISI approved sealing compound and necessary clamps sets and nut & bolts including taking down old unserviceable GI pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Energy efficient inverter street light 45 watt with RTC having the following Technical Specifications : - Housing Material : Aluminium PDC, Top maintainable Front Cover : Clear toughened glass Lens : LM80 certified LED LED Lumen Maintenance : 50,000 hours @ L 70 Control Gear : Isolated, Electronic, CC driver RTC enabled Internal Wiring : Insulated Copper wire Hardware : SS & MS Zinc plated and passivated Ingress Protection : IP 66 Impact Resistance : IK05 Operating Voltage : 140 V~270V Operating Temperature : - 10oC ~50oC Emergency light output : Initial Lumen at Battery mode will reduce to 15-20% Emergency time : 1.5-2 hours Max. (Battery Back-up withLi-ion Battery) mounting on 50mm GI medium grade bracket 1.5 mtr long, fabricated to shape fixed with two number flat iron 50x6mm clamps and 12mm dia bolts, nuts, washers and making connection with PVC copper conductor cable of appropriate size including taking up old UNSV street light of any type and size complete all as specified and directed. Make : Halonix Cat Part No.: - HLSLD - ML04-45-CWL-INV-RTC-R
Supply and fixing in replacement Energy efficient inverter street light 60 watt with RTC having the following Technical Specifications : - Housing Material : Aluminium PDC, Top maintainable Front Cover : Clear toughened glass Lens : LM80 certified LED LED Lumen Maintenance : 50,000 hours @ L 70 Control Gear : Isolated, Electronic, CC driver RTC enabled Internal Wiring : Insulated Copper wire Hardware : SS & MS Zinc plated and passivated Ingress Protection : IP 66 Impact Resistance : IK05 Operating Voltage : 140 V~270V Operating Temperature : - 10oC ~50oC Emergency light output : Initial Lumen at Battery mode will reduce to 15-20% Emergency time : 1.5-2 hours Max. (Battery Back-up withLi-ion Battery) mounting on 50mm GI medium grade bracket 1.5 mtr long, fabricated to shape fixed with two number flat iron 50x6mm clamps and 12mm dia bolts, nuts, washers and making connection with PVC copper conductor cable of appropriate size including taking up old UNSV street light of any type and size complete all as specified and directed. Make : Halonix Cat Part No.: - HLSLD - ML04-60-CWL-INV-RTC-R
Supply and fixing in replacement Energy efficient inverter street light 90 watt with RTC having the following Technical Specifications : - Housing Material : Aluminium PDC, Top maintainable Front Cover : Clear toughened glass Lens : LM80 certified LED LED Lumen Maintenance : 50,000 hours @ L 70 Control Gear : Isolated, Electronic, CC driver RTC enabled Internal Wiring : Insulated CU wire Hardware : SS & MS Zinc plated and passivated Ingress Protection : IP 66 Impact Resistance : IK05 Operating Voltage : 140 V~270V Operating Temperature : - 10oC ~50oC Emergency light output : Initial Lumen at Battery mode will reduce to 15-20% Emergency time : 1.5-2 hours Max. (Battery Back-up withLi-ion Battery) mounting on 50mm GI medium grade bracket 1.5 mtr long, fabricated to shape fixed with two number flat iron 50x6mm clamps and 12mm dia bolts, nuts, washers and making connection with PVC copper conductor cable of appropriate size including taking up old UNSV street light of any type and size complete all as specified and directed. Make : Halonix Cat Part No.: - HLSLD - ML04-90-CWL-INV-RTC-R
S&F MCCB double pole 40 AMPS, 16 KA Fixed Thermal &Fixed Magnetic setting including 4 spreader link set of same make as that of MCCB for connection and lugs as required Make : - Havells, Cat Part No. IHDA3BBD0040 or equivalent in Legrant/C&S/Schneider or Hager as approved.
S&F MCCB four pole 63 AMPS, 16 KA Fixed Thermal &Fixed Magnetic setting including 4 spreader link set of same make as that of MCCB for connection and lugs as required. Make : - Havells, Cat Part No. IHDA3BBD0063 or equivalent in Legrant/C&S/Schneider or Hager as approved.
S & F MCCB four pole 100 AMPS, 16 KA Fixed Thermal &Fixed Magnetic setting including 4 spreader link set of same make as that of MCCB for connection and lugs as required Make : - Havells, Cat Part No. IHDA3BBD00100 or equivalent in Legrant/C&S/Schneider or Hager as approved.
Jiwan Singh
M/S MANJIT SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .