Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance | ₹2.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹2.0 L+₹2,402 (1.20%)Accepted-Finance 36 151 E 46 PERIYAR NAGAR THANGAMAPURIPATTENAM METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | ₹2.0 L+₹2,402 (1.20%) | L2 | Accepted-Finance L2 |
| 3 | L3₹2.0 L+₹2,983 (1.49%)Accepted-Finance 36 151 E 73 PERIYAR NAGAR THANGAMAPURIPATTINAM METTUR DAM 2 | METTUR DAM | TAMIL NADU | ₹2.0 L+₹2,983 (1.49%) | L3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | RATHNA AND CO L2 | SSS ENTERPRISES L3 | MEGA ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Charges for cleaning, disconnection of power cables and control cables, terminal tightness checking of actuator terminal blocks, local push button and lubricating the limit switch mechanism. | 70 | Nos | 795 ₹55,650 | 799 ₹55,930 | 775 ₹54,250 Lowest |
| 2.00 | Charges for reconnection of power and control cables, setting of open/close limit/ torque switches, testing of modules, motors and checking of operation. | 70 | Nos | 1,641 ₹1,14,870 | 1,645 ₹1,15,150 | 1,628 ₹1,13,960 Lowest |
| 3.00 | Charges for power/control cable jointing works for actuator. | 2 | Nos | 3,677 ₹7,354 | 3,680 ₹7,360 | 3,660 ₹7,320 Lowest |
| 4.00 | Charges for Cleaning of Converter cubicles, Field Breaker cubicles, Regulation Cubicle and Field Flashing cubicles, AC/DC racks, Air conditioner units, checking the tightness of AC / DC bus bar joints, terminal blocks in Converter panels, Field Breaker panel and Regulation Panel . | 1 | Nos | 8,987 ₹8,987 | 8,990 ₹8,990 | 8,970 ₹8,970 Lowest |
| 5.00 | Charges for Opening/closing time and contact resistance measurement works of Field breaker main and FDR contacts, testing of relays, transformers & timers, carrying out the modification works for conducting the dummy load test in the Digital Excitation System and measurement of Rotor DC resistance and impedance measurement at standstill, barring gear speed and various speeds during rolling of turbine. | 1 | Nos | 6,764 ₹6,764 | 6,770 ₹6,770 | 6,742 ₹6,742 Lowest |
| 6.00 | Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on GT, UAT’s (A& B) and its NGT, terminal tightness checking in marshaling boxes, metering and protection CT’s. | 1 | Nos | 8,964 ₹8,964 | 8,970 ₹8,970 | 8,945 ₹8,945 Lowest |
Tender Value
Refer Docs
EMD Value
₹1,900
Closing Date
15 Sept 2026, 2:00 pmClosed
CHIEF ENGINEER/MTPS-I
CHIEF ENGINEER/MTPS-I
MTPSI ES Circle MRT UnitII TG area AOH maintenance works to be carried for the year 2026 2027 in the Electrical valve actuators Generator Transformer UAT A B and DVR Equipments in TG area.
2026_EB_699914_1
CE-MTPSI-SE-ES-MRT-OT21-26-27
Open Tender
Electrical Works
Works
20 days
MTPS-I/METTURDAM
As per tender specification
4 documents required · 4 mandatory
₹0
₹1,900
Yes
22 Sept 2026
31 Aug 2026
16 Sept 2026
31 Aug 2026
15 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for cleaning, disconnection of power cables and control cables, terminal tightness checking of actuator terminal blocks, local push button and lubricating the limit switch mechanism. | 70 | Nos | - | - |
| 2 | Charges for reconnection of power and control cables, setting of open/close limit/ torque switches, testing of modules, motors and checking of operation. | 70 | Nos | - | - |
| 3 | Charges for power/control cable jointing works for actuator. | 2 | Nos | - | - |
| 4 | Charges for Cleaning of Converter cubicles, Field Breaker cubicles, Regulation Cubicle and Field Flashing cubicles, AC/DC racks, Air conditioner units, checking the tightness of AC / DC bus bar joints, terminal blocks in Converter panels, Field Breaker panel and Regulation Panel . | 1 | Nos | - | - |
| 5 | Charges for Opening/closing time and contact resistance measurement works of Field breaker main and FDR contacts, testing of relays, transformers & timers, carrying out the modification works for conducting the dummy load test in the Digital Excitation System and measurement of Rotor DC resistance and impedance measurement at standstill, barring gear speed and various speeds during rolling of turbine. | 1 | Nos | - | - |
| 6 | Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on GT, UAT’s (A& B) and its NGT, terminal tightness checking in marshaling boxes, metering and protection CT’s. | 1 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_841355.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .