Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 CrAccepted-AOC | ₹19.5 Cr Quoted ₹19.6 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹19.6 CrRejected-Finance | ₹19.6 Cr | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹19.7 CrRejected-Finance 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹19.7 Cr | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹19.9 CrRejected-Finance | ₹19.9 Cr | L4 | Rejected-Finance Rejected being other than lowest |
| 5 | L5₹19.9 CrRejected-Finance | ₹19.9 Cr | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹17.8 Cr
EMD Value
₹12.2 L
Closing Date
30 Aug 2022, 6:00 pmClosed
Chief Enngineer Pathankot Zone
HQ Chief Engineer Pathankot Zone Pathankot
PROVN OF OTM ACCN FOR MECH INF BN R and S PH I AT JAMMU
2022_MES_525059_1
CEPZ-06/2022-23
Open Tender
Civil Works
730 days
GE (P) Jammu
All as per tender documents
7 documents required · 7 mandatory
₹3,000
GE (P) Jammu
₹12.2 L
Yes
21 Sept 2022
19 May 2022
6 Sept 2022
19 May 2022
30 Aug 2022
23 Aug 2022
Amount
Lumpsum price worked out by the contractor for Building work as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal water supply as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Plumbing Works as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Internal Electrification Works as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Protective Works as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Site Clerance and tree cutting as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Road, Path and Culvert Works as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Sewage Disposal as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for Rain Water Harvesting as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for Strom Water Drain RCC Pipe Works as listed in Schedule 'A' Part-XI.
Lumpsum price worked out by the contractor for SECURITY FENCING AND COMPOUND WALL as listed in Schedule 'A' Part-XII.
Lumpsum price worked out by the contractor for External Water Supply as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the contractor for Summer Appliances as listed in Schedule 'A' Part-XIV.
Lumpsum price worked out by the contractor for Hot Water Supply as listed in Schedule 'A' Part-XV.
Lumpsum price worked out by the contractor for External Electrification Works as listed in Schedule 'A' Part-XVI.
Lumpsum price worked out by the contractor for CONNECTING PASSAGE 2.25 M WIDE Works as listed in Schedule 'A' Part-XVII.
Lumpsum price worked out by the contractor for Demolition/Dismantling Works as listed in Schedule 'A' Part-XVIII
INTERNAL ELECTRIFICATION :
Supply and fixing switch piano flush button single pole two way 5 Amps 240 volts complete all as specified and directed.
Supply and fixing bldg street light fittings 30 watt LED new generation energy saving and environmental friendly long life verstatile pressure dicast aluminium luminaire with mid power LEDs as light source and exclusively designed polycarbonate cover alongwith electronic driver, IP 65 protection and impact resistance of IK07 incl suitable bracket complete with all accssories complete all as specified.
Supply and fix distribution board iron clad, double door with IP-43 1K-08 protection suitable for MCCB as incomer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No. 811888 of Indoasian or equivalent of make Havells, Legrand complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
All as per ser item No. 22 above but distribution board 6 way
Supply and fix blank plate suitable of VTPN MCCB, DB, MCB TPN DB, MCB SPN DB all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5 mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board/panel, watering pipeGI Medium grade 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No. 5 of SSR Part-I 1991 or directed by Engineer-in-Charge and testing on completion.
Supply and fix post top lantern 35 watt LED new generation energy saving and environmental friendly long life verstatile pressure dicast aluminium luminaire with mid power LEDs as light source and exclusively designed polycarbonate cover alongwith electronic driver complement the geometry of the area all as specified and directed.
ROAD, PATH AND CULVERT WORKS
Providing & applying 2.5mm thick road marking strips (retro- reflective) of specified shade/colour using hot thermoplastic material by fully/semi automatiac thermoplastic paint applicator machine fitted with profile shoe heater, driven by experienced operator on road surface incl cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc complete as per direction of engr-in-charge and accordance with applicable specification complete all as specified and directed.
Solar cat eye having 3 LED /side of colour red/yellow to a side ( 6nos) house in tough pressure dia casted aluminium allow of size 125 x 125 x 25 mm with built in steam of suitable length for fixing with approxy LED solar cell battery and light sensor well protected in side under tough under cable for 2 to 3 days (night) after full charge in 8-10 hours make oscar or equivalent make as approved by Engr-in-Charge. Cat part no. OS-809
Stainless steel round road delineator having reflector type red/yellow colour in plastic body protected in side polycarbonated sheet, protected with powder coated wiremesh cage system mouted as approved by Engr-in-Charge. Cat part no. OS-802
Reflective type cat ey having colour red/yellow to a side, casted aluminium allow of size 100X100X20mm with built in steam of suitable length for fixing with protected in side as approved by Engr-in-Charge. Cat part no. OS-786
Information board with ACP sheet retroreflective writing one side size 600x900 mm. Made arround of reflective intensive tape dully fixed on angle iron frame 40 x40x4 mm frame with aluminium sheet both side 2mm thick as required with PCC 1:4:8 for post and PCC 1:2:4 for plateforms size 5'x3' complete all as specfied and directed by Engr-In-Charge.
M&L for forming embankments including raising earth and spreading in layers n exc. 30 cm thick, watering, ramming / rolling to obtain standard procter density not less than 95% at optimum moisture content and finishing to required size, shape etc. The rates shall be inclusive of all material, labour and T&P complete in all respect including cost of procurement & excavation of soil of approved quality from the source etc. Note :- Rates include cost of earth/ soil to be brought from outside the defence land
SEWAGE DISPOSAL
Septic tank excavation in any type of soil, PCC in fdn (1:2:4)brick work in CM 1:4 RCC slab covers include angle iron frame with RCC manhole covers , vent shaft and sludge chambers, inlet, outlet etc complete all as shown on drgs for 50 users.
Soakage well excavation in any type of soil, fdn in PCC 1:3:6, walls built in Honeycombing and solid brick work in CM 1:4, RCC cover slab filling with brick bats, complete all as shown on drgs of size 3.0 mtr dia x 3.0 mtr depth.
EXTERNAL WATER SUPPLY
Supply, laying, jointing and testing of DI (Ductile iron) pipe 200mm bore spigot and socketed type of Class K-7 conforming to IS 8329 of 2000 with inside surface of centrifugally cement mortar lined, laid in trenches / on ground suitable for & including rubber gasket (Push-on) joint and jointing material complete all as specified and directed. Note : Excavation, Returning filling, removal etc will be measured and paid separately under relevant items.
Description all as per item No. 38 above but DI pipe of size 100mm dia.
M&L for Cast iron sluice valve of size 200mm dia with steel spindle and flanged ends drilled complete class PN-1.0 conforming to IS-14846 of 2000 any pattern complete with iron wheel head, with rubber gaskets, nuts, bolts washers and packing materials etc all as directed and as per site requirement. (excavation and earth works will be measured and paid for separately).
Description as per item Srl No. 40 above but of size 100mm dia .
Description as per item Srl No.40 above but of size 80mm dia .
Supply and fixing Cast Iron Air Valves with two air outlets, conforming to IS 14845 of size 200 mm dia bore and fixing up in DI Water Supply mains of size 200mm dia. Including bolts, nuts, washers and rubber gasket etc complete all as directed.
Construction of brick masonry valve pit of size 1200mmx1200mmx1200mm (internal dimension of chamber) with brick work in cement morter 1:4 including plastering internally and pointing externally as the work proceeds complete with MS sheet cover 3.15mm thick and angle iron frame 40mm x 40mm x 6mm with handle, locking arrangement and painting with two coats of synthetic enamelled paint over a coat of red oxide primer on steel surfaces including earth work & excavation in any type of soil, disposal of surplus spoil not exceeding 50m concrete etc all as specified and shown on drawing.
Description all as per item No. 44 above but of size 900mm x 900mm x 1050mm
Description all as per item No. 44 above but of size 600mmx600mmx750mm
Excavation by trenchless technology boring holes for crossing pipe/cable under road / nala/canal/culvert pavement hardstanding unsing necessary machinery / T&P all as required at site.
SUMMER APPLIANCES
Supply, install and testing refrigerators, double door, electric driven (single phase) with high / low voltage autocut off for capacity 210 litres frost free with CFC free refrigerant, energy efficient and BEE 5 star rated
Supply, install and testing Deep freezer hard top of capacity 320 litre frost free having double door suitable for 230Volt single phase electric supply.
Supply and Install Desert Cooler with steel body having 450 mm fan size with Aluminium blade ISI Marked electric driven (Single phase) having nominal air flow capacity 5000 CFM with wall thickness of sheet 1 mm and Water tank and body pillar 1.5 mm thick including prewired electric control panel with immersed pump duly ISI marked pump and Fan motor.
Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type and desigend for input variation between 170 V to 250 V with out put voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 05 KVA
Supply and install voltage stabilizer for automatic operation single phase naturally air cooled indoor type and desigend for input variation between 170 V to 250 V with out put voltage stabilized at 230 V with accuracy of +/- 2.5 % and of capacity 01 KVA
HOT WATER SUPPLY
Supply and fix angle iron stand made out of 50 x 50 x 6 mm angle iron and 50 x 6 mm flat suitable for stand for Cold water tanks incl painting the stand with 2 coat of synthetic enemel paint over a coat of red oxide primer complete all as specified and directed.
EXTERNAL ELECTRIFICATION WORKS
Supply and fixing lightning arrestor (set of three) HT metal oxide surge arrester polymeric type complete with all fittings rated voltage 12 KV continuous operating voltage 10.2 KV, normal discharge current 10 KA, max residual voltage at 8/20 impulse 75 KV etc complete all as specified confirming to IEC-600994-2001.
Supply, installation, testing and commissioning LT Feeder Pillar / Panel board cubical type outdoor, factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of suitable size through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coded sleeves. The cup board shall have a bottom channel of IS MC 75mm x 40mm. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable, lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete all as specified and consisting the following switchgears and accessories:
(i) One No Incoming ACB 800A, 415 volt, 4 pole, Manual draw out type, 50 KA rupturing capacity, lcu=lcs =lcw ( I Sec), with adjustable settings 80% to 100 % thermal maganatic release and standard accessories as applicable. (ii) Outgoing, MCCB, 4 Pole, 250 amp, 415V, 36 KA rupturing capacity , with adjustable settings 80% to 100 %, Thermal Magnetic Release (lcs = 100% Icu) - 01 No (iii) Outgoing, MCCB, 4 Pole, 200 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 01 No (iv) Outgoing, MCCB, 4 Pole, 125 amp, 415V, 25 KA rupturing capacity , with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 01 No (v) Outgoing, MCCB, 4 Pole, 10 amp, 415V, 10 KA rupturing capacity with adjustable settings 80% to 100 %,Thermal Magnetic Release (Ics = 100% lcu) - 04 No (vi) Outgoing MCB, SPN, 20 Amp, 230V-01 Nos (vii) Timer switches digital type programmable every 1 min, 230 volt single phase of 20 Amps rating with MCB 20 Amps DP and contactor of rating 20/25 Amps fitted inside panel/steel enclosure including connections.
Supply, installation, testing and commissioning LT Feeder Pillar / Panel board cubical type outdoor, factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of suitable size through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coded sleeves.The cupboard shall have a bottom channel of IS MC 75mm x 40mm. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable, lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete all as specified and consisting the following switchgears and accessories:
Supply, installation, testing and commissioning LT Feeder Pillar / Panel board cubical type outdoor, factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of suitable size through out the length of the TPN bus bar . The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coded sleeves. The cupboard shall have a bottom channel of IS MC 75mm x 40mm. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable, lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air. XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete all as specified and consisting the following switchgears and accessories :-
Material and laying earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top prjgc, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion all as specified and directed.
Material and laying Earthing complete with G.l earth plate electrode 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore including 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion all as specified and directed
Supply and fixing LED street light luminaire with robust single piece pressure die cast aluminium housing with corrosion resistant powder coating and poly carbonate optics covers to insure IP65 and IK-07 protection. Luminaire shall have separate optical and driver compartment. It shall have non yellowing prismatic poly carbonate modular secondary lens optic cover, laminaire shall have finless design dedicated peanut optics, system efficacy of at least 100 lumen/watt as per LM 79 report, minimum 4500 system lumen, 45W system wattage (including driver), colour temperature (CCT) >5700, CRI > 80, humidity 10% to 90% RH, working temperature -10 Deg C to 50 Deg C. The driver shall be fully potted and shall have power factor > 0.95 and THD < 10% with a minimum inbuilt surge protection of internal 4 KV and external 10 KV. SPD should be mechanically fixed and can be replaced on site without opening the luminaire. Driver should be suitable for an operating voltage range of 140 V-270V AC and cut off switch at > 300V AC and self restore. The luminaire should comply with all the required IEC and IS Standards.
M&L for Bracket for fixing of street light fittings bent to shape, made out of 40 mm dia GI pipe medium grade not less than 1.2 mtr long fixed with two sets of MS clamps made out of flat iron of size 50mmx6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. (Note : MS clamps, nuts, bolt and washer shall be measured seperately under relevant item)
S&F pole mounting junction box of size 300mmx200mmx100mm fabricated out of 2mm thick MS sheet, front openable door with hinges, duly painted with aluminium paint internally and externally over a coat red oxide primer suitable to house and including 04 Nos aluminium bus bar of 63 Amps capacity mounted on suitable insulators, one No MCB SP 6A mounted on dinrail, internally wired with suitable size of copper conductor cable, provision on bottom side for cable entry holes including fixing with steel tubular poles with two Nos Fl clamps 25mmx3mm with nuts, bolts and washers complete and making connection with 1.5 sqmm copper conductor unsheathed FRLS PVC insulated 3 core from junction box to security lights fittings duly laid inside the streel tubular pole and bracket. complete all as specified. Note : 40 mm bore GI pipe light grade, MS clamps , nuts , bolts & washers and 3 core 1.5 sqmm cable, GI brackets will be measured separately.
Supply and fixing copper cable multistrand PVC insulated PVC seathead 1.5 Sqmm 3 core all as directed by engr-in-charge
Construction of platform of size 3000 x 2500 x 1200 mm for installation of transformer with brick steps on one side, chain link fencing around transformer, fencing should have hinged door and locking arrangements complete all as shown on drawing No CEPZ/C-TD/002/13 sht 2/5 complete all as specified.
Supply and fix cable route indicator of size 100 mm x 100 mm x 5 mm thick GI plate with insertion three on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC as required for LT/HT cable incl necessery earth work all as specified and directed.
Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 836599.07 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Om Parkash Nargotra Constructions Pvt Ltd
DES RAJ NAGPAL CONTRACTORS PVT.LTD
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
Saru Enterprises Pvt Ltd
SRM BUILDERS AND ENGINERS PVT.LIMITTED
M/S BHATIA BUILDERS AND CONTRACTORS
M/s Ravinder Kapoor Engineers and Builders
KAPAHI CONTRACTS PVT LTD
BHARATSHAH CONSTRUCTION CO
Chandra Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid