Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹9.0 L
EMD Value
₹17,940
Closing Date
25 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VISHWNATH KHICHI
ED - Karnal
Providing 01 No. 45 KVA DG Set in the O/o Executive Engineer, Quality Control Division, PWD BandR Br., Karnal.
2025_HRY_491217_1
2025BD2874F3 2F11 4F76 A377 E83F666291CF665BAR
Open Tender
Electrical Works
Works
90 days
Karnal
2 documents required · 2 mandatory
₹1,000
₹17,940
Yes
17 Dec 2025
17 Dec 2025
26 Dec 2025
18 Dec 2025
25 Dec 2025
18 Dec 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer Electrical Division PWD B&R Br., Karnal
Name of Work: Providing 01 No. 45 KVA DG Set in the O/o Executive Engineer, Quality Control Division, PWD BandR Br., Karnal.
DNITRs. 8.97 Lakhs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] BI01010001010000000000000515BI0100001113 1 Each 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] BI01010001010000000000000515BI0100001114 1 Each 2 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
3 [23.22.8.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts [Through Rate] BI01010001010000000000000515BI0100001115 1 Each 3 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
4 [23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages. [Through Rate] BI01010001010000000000000515BI0100001116 2 Each 4 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
5 [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] BI01010001010000000000000515BI0100001117 2 Each 5 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
6 [23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame. [Through Rate] BI01010001010000000000000515BI0100001118 2 Each 6 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
7 [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] BI01010001010000000000000515BI0100001119 2 Each 7 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
8 [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] BI01010001010000000000000515BI0100001120 25 Metre 8 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
9 [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] BI01010001010000000000000515BI0100001121 2 Each 9 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
10 [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] BI01010001010000000000000515BI0100001122 4 Each 10 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
11 [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] BI01010001010000000000000515BI0100001123 4 Each 11 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
12 [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] BI01010001010000000000000515BI0100001124 20 Metre 12 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
13 [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] BI01010001010000000000000515BI0100001125 15 Metre 13 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
14 [24.13.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 46. 50 Sq mm 3.5core (Arm.) [Through Rate] BI01010001010000000000000515BI0100001126 50 Metre 14 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
15 [24.2.7.3]LT CABLE 7.3. Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm Cable 2 to 4 Core [Through Rate] BI01010001010000000000000515BI0100001127 4 Set 15 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
16 [24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm [Through Rate] BI01010001010000000000000515BI0100001128 16 Each 16 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
17 [24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate] BI01010001010000000000000515BI0100001129 10 Metre 17 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
18 [24.7]RCC FOUNDATIONS FOR DG SET "Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)" Unit: per cum [Through Rate] BI01010001010000000000000515BI0100001130 3 Per Cum 18 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
19 Pdg. And Fixing of wire mesh jali around the transfarmer of size 4` x 8` made out of 75 x 25 x 3.25 mm jali fixed with angel iron frame made out of M.S. Angel 50 x 50 x 6 mm. BI01010001010000000000000515BI0100001131 12 Sqm 19 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
20 Supply and Erection of rubber mat of size 1M x 2 M X 12 mm thick suitable for 11 KV ISI marked complete in all respect up-to the entire satisfaction of the engineer In-charge of the work. BI01010001010000000000000515BI0100001132 2 Each 20 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
21 S/I/T/C of Three Phase 45 KVA (CPCB-IV plus ), Diesel Generating Set with AMF Panel comprising of: A. DIESEL ENGINE: 4 Cylinder, air/ liquid cooled, Turbocharged After cooled, developing 60BHP at 1500 RPM. This is electric start, compression ignition, 4 stroke engine design to run continuously 1500 RPM. Diesel conforms to present CPCBIV plus norms. The diesel engine comprise of following: • Radiator with Fan • G3 as per ISO 8528 Part V class governor • Dry type Air cleaner with service indicator • Lube Oil and Fuel filter • First fill of lube oil and coolant ALTERNATOR: • Electric starter motor with soft starting system • Battery charging alternator • CRDI System • DOC • 1 X 12V DC battery B. Alternator, suitable for continuous operation rated at 1500 rpm 415.00V, 0.80PF, 50.00Hz, Ph. in SPDP enclosure, self-excited, self-regulated Brush less, floor mounted. The alternator conforms to IS:4722,BS EN 60034-1 and will be suitable for tropical condition. ACOUSTIC ENLOSURE: • The Enclosure is of modular construction. • Durable industrial locking system is provided on doors. • The sheet metal components are 9 tanks pre-treated and is Polyester based powder coated (inside as well as outside) for long life. • Specially designed sound attenuators are provided to control sound at air entry and exit points inside the enclosure. • In - build draw in type fuel tank of suitable capacity. • The walls of enclosure are insulated with the fire-retardant and noise absorbent foam/Rockwool so as to comply with the noise level of 75dB(A) at distance of 1mtr. in open free field environment as per ISO 8528 part 10 specified by ministry of Environment and Forest. DG CONTROL PANEL WITH GENSET CONTROLLER: The Control Panel is manufactured with 16/18 gauge CRCA sheet and is powder coated for a weather-proof and long lasting finish. The Control Panel consists of Microprocessor based genset controller, MCCB of suitable rating, Key Switch, Push Button (starter), LED: Battery Charging alternator fail indication, Current Transformer, Instrument fuses. The genset controller has all the basic safeties and protections. including the cost of 50 Ltr. Diesel, 50 Ltr. Diesel Tank Make:- Cummins/Greaves Cotton/Kirloskar/ Perfect Boudin/ Escorta Kubota BI01010001010000000000000515BI0100001133 1 Each 21 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
BOQ_569539.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .