| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.4 L+₹83,754.60 (2.83%)Rejected-Finance RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹31.6 L+₹2.0 L (6.85%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L3 | Rejected-Finance Higher | |
| 4 | L4₹31.9 L+₹2.4 L (7.95%)Rejected-Finance | L4 | Rejected-Finance Higher | |
| 5 | L5₹33.1 L+₹3.5 L (11.7%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L5 | Rejected-Finance Higher |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
REPAIR/MAINT AND DAY TO DAY COMPLAINTS OF EXTERNAL ELECT SUPPLY UNDER GE NAMS
2020_MES_378606_1
GE NAMS - 53 / 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹60,000
Yes
21 Nov 2020
18 Sept 2020
9 Oct 2020
18 Sept 2020
8 Oct 2020
1 Oct 2020
60 days
Amount
Day to day attending complaints & maintaining the electric supply GE NAMS Area round the clock (24 Hours) comprising the following HT /LT net work / transformers / LT panels by contractor/his rep with following networks:-
(i) Feeder No-1 emanating from 66 KV grid Sub station to TOP II, Appx length – 4.5 Km.
(ii) Feeder No-2 emanating from 66 KV grid Sub station to NME, Appx length = 1.8 Km, LT Panels , LT overhead lines appx – 2.50 km and 01 No transformer.
(iii) Feeder No 03 emanating from TOP I Sub station to Old Officer colony Feeder, Appx length = 3 Km along with 08 transformers with GOD s of different capacities , LT Panels , LT overhead lines appx – 4.5 km.
(iv) Feeder No 04 emanating from TOP I Sub station to Back Feeder Appx length = 3 Km along with 07 transformers of different size, LT Panels GOD's, LT over head line appx 4 Km.
(v) Feeder No 05 emanating from TOP II Sub station to Old Kathania Accn Appx length = 2 Km along with 06 transformers GOD'S, LT Panels, LT over head line appx length 4.5 Km with cable/service connections.
(vi) Feeder No 6 emanating from TOP II Sub station to Back Feeder to Army school, central school Appx length = 3.5 Km along with 05 transformers of different cap with GOD's, LT Panels, LT over head line appx 1.5 Km.
(vii) Feeder No 7 emanating from TOP II Sub station to New officer Colony: & OTM 54 Bde HQ, 5 Kumaon,19 JAK, 415 Fd Hosp and 21 PUNAJB Appx length = 4 Km along with 08 transformers of different size with GOD's, LT Panels, LT over head line appx 3 Km with cable/service connections.
(Viii) Feeder No 8 emanating from TOP II Sub station to NOC II, Appx length = 1 Km along with 01 transformer with GOD's, LT Panels over head line appx 2.5 Km.
(ix) Feeder No 9 emanating from TOP II Sub station to CP -6 baffle range Appx length = 4 Km along with 02 transformers of different size with GOD's, LT Panels, LT over head line appx 0.5 Km.
(x) HT feeder No 10 emanating from 66 KV Sub station to New Red Colony, New Kathania & NOC-I Appx length = 2.5 Km along with 06 transformers of different size with GOD's, LT Panels, LT over head line/UG Cable appx 3 Km with cable/service connections.
(xi) HT feeder No 11 emanating from 66 KV Sub station to New Red Colony MAP Ph II& NME Ph MAP Ph II Appx length = 4.5 Km along with 06 transformers of different size with GOD's, LT Panels, LT UG Cable appx 13 Km with cable/service connections.
(xii) HT feeder No 12 emanating from TOP II Sub station to New Kathania MAP Ph II &, NOC-I MAP Ph IIAppx length = 5.5 Km along with 06 transformers of different size with GOD's, LT Panels, LT UG Cable appx 17 Km with cable/service connections.
Preodicity - round the clock
(B) Nature of work to be done -
(i) Maintaining the serviceability and attending break down complaints of electric supply of all the feeder of New ASR Cantt area mentioned under Sl 2.01(i) to 2.12(xii) here in before .
(ii) Attending the complaint of external electric supply – from pole to main board / DB of the occupant .
(iii) Periodical maintenance/complaints of all the feeders mentioned here-in=-before which includes – (a)Replacement of overheated jumper / blown off jumpers .
(b) Replacement of blown off HT fuses .
(c ) Periodical complaints of LT panels .
(d) Suitable Wooden ladder shall be provided by the contractor to do the complaint.
(e) Vehicle shall not be provided by the Department.
(f) Complaint to be done on same day otherwise penalty to be made at @ Rs. 500/- per complaint.
(g) Complaint Register & complaint slip shall be maintained by the contractor and putup to concerned JE/Engr in Charge on daily basis.
Note – (i) Time consuming jobs such as replacement of defective cable by extension of loop and periodical trimming of trees / branches along the over head lines shall be measured and paid separately .
(ii) Minor items such as PVC tape, necessary tools shall be arranged by contractor at no extra cost .
(iii) Mandatory tools – Insulting plier, cutter, screw drivers, DE spanner set shall always be in possession by the contractor .
(iv) Before attending any complaints of external elect supply contractor or his rep shall ensure that proper shut down has been taken.
(v) All safety precaution will be taken by the Contractor/his rep incase of any lapse contractor will be responsible for the same.
Excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil.
Excavation in trenches exceeding 1.5m/in width & not exceeding 3m in depth for and getting out in any of soil.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed.
All as per srl item No 7 here-in-before but of size 120 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 50 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 35 Sqmm 3.5 core.
All as per srl item No 7 here-in-before but of size 25 Sqmm 4 core.
All as per srl item No 7 here-in-before but of size 16 Sqmm 4 core.
All as per srl item No 7 here-in-before but of size 16 Sqmm 2 core.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge of size 50mm outer dia and 38mm inner dia
All as per items No 14 here in before but of size 77mm outer dia and 63mm inner dia.
All as per items No 14 here in before but of size 90mm outer dia and 76mm inner dia
All as per items No 14 here in before but of size 145mm outer dia and 126mm inner dia
Supply and fixing in replacement danger notice plate of 1.6mm thick mild steel sheet , virtreous enameld white, with letters , figures and conventional skull and bones in signal red colour(in three language) and fixed with MS clamps , bolt and nuts of approved size for LT 20 X 15 CM size complete all as specified and directed.
All as per items No 18 here in before but for 66 KV/11KV HT of size 25 x 20CM
Supply and fix in replacement chain link MS galvanised fencing 4 mm dia any mesh /size or type complete all as specified and directed.
M & L in replacement of angle iron fencing channel duly, drilled holes to fix the flat iron fillets (for securing wire mesh etc) including all necessary drilling, posts and struts in fencing including cutting tops to shape as directed , drilling holes , notching for wire etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or reveting etc and similar work conforming to Fe-290Gde E-165 including painting with two coat shynthetic enamel paint over a coat of red oxide complete all as specified and directed.
S&F in repair for galvanished two strand barbed wire 2.24mm dia barbs at 75mm spacing and straining and fixing to anyn type of standard rails straining bolts, incl,securing or tying at crossing with and provn of galvanised MS wire staples or steel pins etc and complete all as specified.
Excavates and relaying cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
S & F in replacement straight through/end termination joint heat shinkable of any size suitable for 3 core 11000 volts XLPE HT UG cable of size 70 Sq mm to 120 Sq mm complete all as specified and directed.
Material and Labour in replacement straight through joint/End temination kit of heats shrinkable suitable for above 185 sqmm to 300 sqmm HT 3 core 11000 volts XLPE cable type complete all as specified and directed.
Material & labour for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed.
Supply and erect steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-31 ( 9 mtr long) erecting in position all as specified/shown on drawing and as directed by Engr-in-Charge Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items.
Supply and fixing LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management,IP 66,Operating Voltage 140-270 Volts, with Lens and Surge Voltage Protection of luminaires 60 watt LED 6000K complete fitting including 1.50mtr(minimum) 2core PVC insulated aluminium cable from conductor to street light fitting all as specified.
Material and labour in replacement for ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent HT/LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
Supply & fixing in replacement of LT stay assembly comprising of 7/3.15mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm incl necessary Excavation and PCC all as specified and directed by Engr-in charge
S&F in replacement loop type porcelain insulator white/brown or green small size with cover dimensions of 65x 90 mm clearance of whole 16 mm as specified and directed by Engr-in charge.
Replacement of pin type porcelain white/brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height,65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint.
M & L in replacement Pre stressed concerete pole 9 mtr long of cross section of 102mm x 172mm at top and 102mm x 279 mm at bottom class 10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic paint in black & white step each upto 1.5 mtr high from coping over a coat of primer including numbering of poles as directed. Note:- (i) Exavation and foundation will be paid and measure separetly.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge.
Material & labour for providing precast cement concrete 1:2:4, type B-1, using 20 mm graded aggregate in landings, cover slabs (for man holes etc) chajjas, water trouhghs, shelves and similar articles including form work complete all as specified and directed.
Material & labour mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less that 0.9mm dia or securing with clips complete all as specified.
Supply and fill up transformer oil topping up having dielectric strength not less than 40 KV at 4 mm gap conforming to IS complete all as specified and directed.
Supply & fixing in replacement Pin/Disc type type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut for 11000 volts grade, including removal of existing insulators complete all as specified and directed.
Supply & Fix in replacement flood Light Luminaire 120 watt with .high power SMD LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter, pressure die cast, powder coated in IP 66 Including protection over temperature complete all as specified and directed
Supply & Fix in replacement flood Light Luminaire 150 watt with .high power SMD LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast, powdre coated in IP 66 Including protection over temperature complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 300 sqmm 3.5 core complete all as specified and directed.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
M & L bricks work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius built in cement mortor 1:4 complete all as specified and directed.
M & L 15mm thick plastering in cm 1:4 over fair faces of bricks/concrete surface finish even and smooth without using extra cement complete all as specified and directed.
Servicing and repair/maint of ACB Switch upto 800 Amp 430 Volt alongwith tripping system and carried out the fwg repair/tests made for smooth operation. (a) Cleaning and greasing of mechanism, Operation, testing of trip and close electrical and manual mode, Spring charging testing electrical and manual mode, Cleaning of panel insulater CT &PT unit, (a) Service will be carried out through Service Engineer of Manfacturer /Authorised Service Engineer only. (b) The cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc essentially required to make the breaker serviceable shall be deemed to be included in the quoted rate.
supply and fixing in replacement of ACB 800Amp gear box with tripping gear machanisam including all minor parts for repair of the ACB complete all as specified directed
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed.
Supply, installation, commissioning in replacement and testing in replacement of switch Air break, Gang operated with 12 insulator switch Triple pole, mechanicaly operated, mounted on insulator and steel frame, for current rating 200 Amp operating Voltage 11 KV out door, vertical mounted type, complete with locking arrengement, assembly with fuse mount carrier and fuse element of required capacity and isolater suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity 10 Amp, with DO fuses assembly and one No. operating Rod of 25 mm dia bore medium grade GI pipe of suitable length, worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD including nut, bolt, washers including taking down existing unservicable set all as specified and directed.
S & F in replacement of guard wire with galvanised steel wire 4mm dia for HT/LT OH line complete all as specified and directed by Engineer-In-charge.
Supply and fixing for earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to GI strip of size 32X6mm as earthing lead by means of nuts, bolts, check nuts and washers of galvanized iron or steel all as shown on Electrical Plate No 3 of SSR Part-I 2009, connected to earthing test point all as specified or indicated including testing on completion. The quoted unit rate shall include the following elements as given below :- (a) Earth electrode as mentioned above (b) Main earthing lead of 32X6 mm GI strip from earth electrode to test point up to 7.5 mtrs. (c) Connecting earthing lead and electrode all as specified and testing complete. (d) Adequate quantity of charcoal and salt (e) GI protection pipe of 40 mm dia light grade of length not less than 5.00 mtrs. (f) Necessary excavation, earth work and PCC pit , angle iron 40x40x6mm frame including RCC cover.
All as per Srl Item No 51.00 here in before but earth lead galvanised iron wire of 4mm dia connected by means of GI nuts, bolts and washers, 15mm bore light grade GI protection pipe
Supply and fixing in replacement of male female contacts of gang operative switch made out of brass and rated capacity 200 amps ,make matching with the existing switch complete all as specified and directed .
Supply and fixing in replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
Supply & fixing in replacement of lighting arrestor metal oxide type gap less heavy duty single pole suitable for rated system voltage 12 KV and working rated 9 KV normal discharge.
Supply & fix in replacement of LED security Light Luminaire 25 watt 6000K with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified.
Material and labour for PCC 1:3:6 type D-2 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 185 sqmm 3 core laid in duct / trench/along pole etc including making connection complete all as specified and directed.
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for road crossing GI tubing of any size for cable protection complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
Supply and laying un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink) for effective thermal management, sturdinessexcellent corrosion resistant IP 66,Operating Voltage 140-270 Volts, PF (0.95), Assemetric Lens Type-1,No. of LEDs=24 Nos,Luminous Flux >5000Lm,Efficacy of LED > 130 Lm/W,Beam Angle 153x107,LED driver current > 750 mA,Surge Voltage Protection (ref IEC61000-4-13 )of luminaires 90 watt LED 5700K complete fitting.
Taking out carefully manually by excavation of existing cable with loops and relaying with DWC pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) HT/LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
Taking out existing gravels/hardcore material from the bottom of substn / equipment completely for cleaning and spraying of anti grass chemical and screnning the hardcore material and refill the same at places complete all as specified and directed by Engr in charge. Note:- Anti Grass chemical and loose filling of aggregate for topping up will be measured and paid separetly respective item of BOQ.
S&F in replacement 70sqmm HT 11KV single core heavy duty insulated cable from top disc insulator to GOD and disc to disc in any lenth as jumper wire with complete nuts & thimbles all as required at site.
Supply & fixing in replacement of MCCB Capacity 36 KA 4 pole 630 Amps adjustable thermal magnet to release type with preader and aluminium lugs all as required at site.
All as per item 68 here in before but 500 Amp 36 KA
All as per item 68 here in before but 400 Amp 36 KA
All as per item 68 here in before but 250 Amp 25 KA
All as per item 68 here in before but 315 Amp 36 KA
All as per item 68 here in before but 200 Amp 25 KA
All as per item 68 here in before but 160 Amp 16 KA
M & L in replacement of out door type aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator of size 90 x 60 x 45 cm made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer and fixed and supported with anlge iron grouted in PCC 1:2:4 upto 0.30 mtr high from ground level all as directed by Engr-In-Charge.
Material and Labour straight through joint heats shinkable suitable for upto 50 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heats shinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material and Labour straight through joint heats shinkable suitable for 185 sqmm to 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material & labour for cleaning away all grass vegetation, scapling shrubs bushes under grouth roots and trees not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness, existing foliage / grass will be uprooted by machinery / maually as per the requirement and safety of cables complete all as specified and directed.
S&F DC Power back min 2Hrs battery backup 24V DC including charging equipment suitable for 11KV 800Amp VCB operting system complete all as specified .
Prunning of trees of over head HT/LT lines by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by Engr in Charge.
Supply and replacement HT 11 KV bush rod suitable for indoor / outdoor type 250 to 315 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
All as per Srl item No 82.00 here-in-before but suitable for 160 to 200 KVA transformer.
Supply and fixing in replacement thermoplastic polycarbonate cable junction boxes IP 55/ IP 65 of dimension 200x160x98mm with metric Knockouts for cable entry with five terminals and cable glands with lock nuts light grey RAL suitable for 16/25 Sqmm UG Cable Complete all as specified and directed By Engineer-in-Charge.
Supply and fixing in replacement aluminium thimble of size 50 sqmm
Supply and fixing in replacement aluminium thimble of size 95 to 120 sqmm
Supply and fixing in replacement aluminium thimble of size 185 to 240 sqmm
Supply and fixing in replacement aluminium thimble of size 300 to 400 sqmm
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and fixing in replacement bracket made out of GI pipe 50/ 40 mm medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for street light all as specified and directed
Material & labour for 2 Pole structure complete painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on HT Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete all as specified and directed. Note:- One 2 pole mild steel struture complete on HT PCC pole steel members fixed thereon shall be considered as 'One Unit'.
Painting of PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping ovdirer a coat of primer including Numbering of poles as directed by Engr-in-Charge
Shifting of transformer from one place to other place within the cantt area including disconnecting / reconnecting all connection any time any capacity all as directed by Engr in charge.
Material and labour in replacement of LT fire resistant PVC self adhesive electrical insulaion tape high quality size minimum 18 mtr long x 1.8 CM width complete.
Material & labour for restrainging ACSR conductor HT/LT providing suitable proper sag all as specified and directed.
Intrernational Engineers
Mahajan construction company
Ghuman Builders
M/S MAHAJAN CONSTRUCTION CO
Mahajan Builder
Bharat Builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .