| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹7.8 L+₹66,575 (9.31%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹8.6 L+₹1.4 L (19.7%)Rejected-Finance HNO 365 STREET NO 12 TALAB TILLO JAMMU RISHI TRADING CO TALAB TILLO ROAD OPP FRIENDS LANE JAMMU JAMMU KASHMIR 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance 3RD LOWEST |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
13 May 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER
ELECTRICITY URBAN DISTRIBUTION CIRCLE, BUNGLOW NO.-9, OLD POWER HOUSE COLONY, RAILWAY STATION ROAD, GORAKHPUR
FOR THE WORK OF AGAINST SANCTIONED PACKAGE NO. 155/2020-21
2021_PVVNV_584992_1
02/EUDC(G)/2021-22
Open Tender
Electrical Works
Lump-sum
30 days
AREA OF EUDD-IV GKP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SUPERINTENDING ENGINEER EUDC
₹7,500
26 May 2021
30 Apr 2021
14 May 2021
30 Apr 2021
13 May 2021
30 Apr 2021
180 days
Amount
fo|qr uxjh; forj.k [k.M&prqFkZ] xksj[kiqj ds vUrxZr tek ;kstuk ys[kk'kh"kZ esa Lohd`r iSdst la[;k 155@2020&21 ¼th0Mh0,0 ekucsyk vkoklh dkyksuh] djheuxj] xksj[kiqj esa U;w ,p0Vh0@,y0Vh0 ykbZu cukus dk dk;Z½ ds dk;ksZ dks lseh VuZdh vk/kkj ij djk;s tkus gsrq dk;Z dk fooj.k%&
Loading, unloading and safe carriage of following materials from Store Centre, Gorakhpur to JE dump Store and JE dump Store to work site with proper stacking :-
11KV XLPE 3x120 sq mm.
ST Pole 11 mtr. Long
11 KV Dropper Angle
11 KV Top channel
Stay complete
11 KV T-off Channel with support
11 KV Disc Insulator with Fitting
11 KV Cable Jointing Kit 3X120 Sq.mm.
11 KV Cable Jointing Kit for 11 KV ABC (3X120+100) Sq.mm.
11 KV ABC cable (3X120+100) Sq.mm.
LT ABC cable (3X120+1X95+1X16) Sq.mm.
Earthing Complete
Single Phase Electronic meter
Three Phase Electronic meter
Supply of following material/fitting complete in all respect :-
Nuts & Bolts of different size
Holding Clamps
GI Pipe 6 inch dia
Distribution Box with Clamp (Distribution box shall be made from 20 SWG CRCA sheet by Deep Drown method with powder coating & size of box shall be 418 mm X 300mm X 120 mm (Roof of the box shall be tapered on both sides to drain the rain water)
Dead end Clamp with I Hook (Insulated) for LT ABC cable (3X120+1X95+1X16) Sq.mm.
Suspension Clamp with I Hook (Insulated) for LT ABC cable (3X120+1X95+1X16) Sq.mm.
Aluminium XLPE Cable 1X35 for energizing Distribution box
LT insulated Piercing Connector for Line to Line Jumpering in case of tapping
LT clamp for STP pole with Nuts & Bolts
LT Cable 2X6 Sq.mm. armoured
LT Cable 4X16 Sq.mm. armoured
Shackle insulator
The excavation of 2 nos. foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of double Pole with fixing of necessary clamps & accessories (Top Channel, Dropper Angle etc.) as per required. All required materials such as Holding clamp/STP clamp, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). Making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
The excavation of foundation pit of size 750mmX450mm and having depth of 1/6th of the full length of the pole. Fabrication & erection of ST 11 mtr. long Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp/STP/LT clamp, LT shackle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc 1:4:8 (Cement, sand & 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). In case of ST Pole making Plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rainwater gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
Erection and grouting of stay in CC ratio 1:4:8 of Cement, Sand and Stone Ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Painting of Pole with Aluminium paint & Red oxide paint provided by contractor
Earthing of ST Pole by MS earthing Rod & 6 SWG earthing Wire as per RESPO norms.
Laying, stringing, sagging, binding and jumpering of ABC (3X120+100) Sq.mm. Cable of 11 KV Line with fixing of required accesiories
Laying, stringing, sagging, binding and jumpering of ABC (3X120+1X95+1X16) Sq.mm. Cable of LT Line with fixing of Distribution Box with Clamp, Insulated Dead end clamp with I hook, Suspension clamp with I hook(Insulated), LT insulated Piercing connector, XLPE 1X35 Sq.mm. Al. cable for enerzing DB.
Laying and dressing of under ground 11 KV XLPE 3x120 sq mm by Horizontal drilling method as per RESPO norms. The Depth of horizontal drilling shall be between 2 to 3 meters or as per site required.
Errection of Cable Jointing Kit & Hoisting of cable on double pole using G.I. Pipe 4"dia 3 Mtr. long (G.I. Pipe 4" Dia and other Necessary Materials excluding 11 KV XLPE Cable 3X120 mm² Cable provided by Contractor)
Errection of 11 KV ABC (3X120+100) Sq.mm.Cable Jointing Kit
Preparing the Single phase electronic meter by fixing plastic/hologram seals and entering meter data on meter register and then marking the lab meter No. on meter cover with permanent marker pen. After that replacement/Installation of Single Phase electronic meters on connections at the outside the main gate of permises of the consumer including the work of Sealing the meter and filling of sealing certificate properly and handing over copy of sealing certificate to consumer and concerned division/subdivision on same day.
Preparing the Three phase electronic meter by fixing plastic/hologram seals and entering meter data on meter register and then marking the lab meter No. on meter cover with permanent marker pen. After that replacement/Installation of Three Phase electronic meters on connections at the outside the main gate of permises of the consumer including the work of Sealing the meter and filling of sealing certificate properly and handing over copy of sealing certificate to consumer and concerned division/subdivision on same day.
Disconnection and Re-connection of consumer cable of complete LT Line (Single/Three Phase)
Dismantling of following Line materials and safe loading, unloading and carraige of dismantled material from work site to departmental store (As per site requirement)
Nuts & Bolts of different size
Holding Clamps
M/S JAI AMBE TRADERS
Rishi Trading Co.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .