Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.4 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹15.5 L+₹2.0 L (15.2%)Rejected-AOC AMBALA CANTT | 2 | Rejected-AOC 2nd Lowest |
Tender Value
₹13.8 L
EMD Value
₹27,700
Closing Date
17 Dec 2019, 1:00 pmClosed
Executive Engineer
EE PHE GWI Division Rewari
Drilling of 1 No and Providing and fixing of 1 No pumping machinery by Pvt RRig Method in Village Israna Distt Panipat
2019_HRY_112125_1
SE/GWI/3720/Israna
Open Limited
Miscellaneous
Works
15 days
Israna Panipat
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Engineer in Chief
₹27,700
9 Jul 2020
10 Dec 2019
17 Dec 2019
10 Dec 2019
17 Dec 2019
10 Dec 2019
Amount
Drilling of 609.60 mm dia bore by Rerverse rotary drilling (Reverse Circulation method) according to ISI specification No.2800-1991 (Part-1) as amended upto date and modified to extent of the specification attached with this schedule of items of work in all kinds of soils and boulders upto 75mm dia except rocky strata including the cost of all consumable stores, fuel oils, soil, stabilizing material and transportation of rig and other accessories to the site of proposed bore and back, complete to the satisfaction of the Engineer-in-Charge with Contractor Pvt. Rig.
Providing and fixing for lowering 273.10 mm i/d dia ERW steel pipes as per IS 4270/2001 as amended upto date, duty ISI marked for casing pipe in 4 to 7 meters random length manufactured out of 8 mm thick MS plates with required number of M.S socket 177.80mm length with inside thread to pmatch the pipe threads and made out of MS plate in to borehole in vertical position including cost of all scaffolding, derricks, Jim, poles, tools and plants, ropes gays MS clamp embedded in foundation etc. complete in all respects to the satisfaction of the Engineer-in-charge of the work including cost of all cutting, threading of pipe where required and all sockets. The pipes shall be painted with anti-corrosive paints and covered tightly polythene.10” i/d M.S. Pipe.
Providing & fixing and lowering 219.10 outer dia ERW steel pipes as per IS 4270/ 2001 as amended upto date duly ISI marked for housing pipe in 4 to 7 meters random length manufactured out of 6.4 mm M.S plates with required number of M.S socket 177.80mm with inside thread to match the pipe threads and made out of M.S plate in to borehole in vertical position, including cost of all scaffolding, derricks, Jim, poles, tools and plants, ropes, gays M.S clamp embedded in foundation etc. complete in all respects to the satisfaction of the Engineer-in-charge of the work including cost of all cutting, threading of pipe where required and all sockets. The pipe shall be painted with anti corrosive paint & covered tightly with polythene.
Labour for lowering 200mm i/d ISI marked stainless steel (SSC) cage as including M.S. Socket with welding material ISI marked Stainless Steel (V-wire welding ) cage as per code No. IS 110:2000 (200 x 8.00 x 0.50 mm).(Supplied by Deptt)
Providing & fixing of M.S. bail plug end cap.
Providing & fixing of Center Guides. (i) 250mm ø ( 1x 3 = 3 Nos.)
Providing & fixing of Center Guides. (ii) 200mm ø (1 x 3 = 3 Nos.)
Providing & fixing of M.S. cap 250mm ø.
Providing & fixing of M.S. Reducing socket 250mm ø x 200mm ø.
Supplying & packing of Pea Gravel (A-Grade) for use as pack in tubewells size of over 2.00mm to 3.35mm with uniformity coefficient Not to exceed 2.00. The Gravel should be confirming To requirement of ISI, 4097-1967 regarding its physical Characteristic quarry at Panchkula/Chandi Mandir.
Providing clay seal of thickness 4.0mm or above consisting of balls of local lay or bentonite mud to be placed in the annular space around the assembly the clay seal should be provided at a level of minimum 25.00m above the top most screens depending onthe logging result.
Development of tubewell with Air Compressor having capacity 450PSI 250 CFM according to clause 9.3 of IS: 2800 - 1991 (Part-I) as amended upto date and specifications attached and as directed by the Engineer-in-Charge of the work including the cost of all consumable stores, fuel, oil, compressors and machinery etc. as required for this work. Developed by Air Compressor of 450 PSI 1200 CFM. (1 x 10 = 10 Hrs.)
Electric logging of Tubewell
Supply and Fixing of Service cable (35sqmm)
Supplying, erection testing and commissioning of submersible pumping sets as per BIS SPECIFICATION No. 8034 - 1989 (as amended up to date for pumps ) and IS 9283 – 1979 (as amended up to date for motor ) the pump motor sets should be capable of pumping clear fresh cold water having characteristics as specified in Clause – 4 of IS 8034 – 1989 and clause 4.1 of IS 9283 – 1979 .600 LPM /90 M Head (V-8) 20.00 BHP Each Make Grundfoss, calama , KSB , Franklin , Texmo.
Prov. and fixng M.S. Clamp
Supplying erection, testing of fully automatic Electric Control Panel Board for tubewells in pump chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of Angle Frame containing 1 No. fully automatic air brake starter suitable for 25 HP motor, Main switch of suitable range with HRC fuse, 1 No. Volt Meter (0 to 500 Volts), 1 No. Amp. Meter of 0 to 100 Amp. 3 Sets of indicating lamp Capacitor of suitable capacity and 1 No. single phase preventers with the timers switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No.II. (Make L&T, Siemens, BCH, Crompton Greaves, Havells).
Prov. and fixng M.S. Base Plate
Prov. and fixng CI Bend 90° (1x 17 =17)
Bidder Name
Amount
Guru Kripa Electrical and Engineering Works
Perfect Engineers
Perfect Engineers
Perfect Engineers
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .