Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹13.0 L
Closing Date
15 Aug 2026, 6:00 pmClosed
commissioner nagar nigam pali
Suraj pole pali
SITC of Ground mounted solar and 25 year comprehensive operation and maintenance under jal hi amrut scheme of amrut 2
2026_DLB_578820_1
Solar
Open Tender
Solar Power Plants
Percentage
150 days
nagar nigam PALI
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
commissioner nagar nigam pali
₹13.0 L
Room no. 30 nagar nigam pali
7 Oct 2026
28 Jul 2026
17 Aug 2026
28 Jul 2026
15 Aug 2026
28 Jul 2026
3 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SITC of Solar Plant | |||||
| 1.01 | SITC of Grid interactive Solar Photovoltaic Power Plant of required capacity having specifications as per A, B, C, D, E, Fand G
(a) Solar Photovoltaic module: MNRE approved and ALMM listed, SPV module of capacity 610 Wp or above, Anodized Aluminium Alloy Framed Topcon G12R Topcon Bifacial, manufactured in India, conforming to 15 14286/IEC 61215, 15/IEC 61730-Part-1, IS/IEC 61730-Part-2., 2 mm Low Iron ARC semi-tempered glass , IP-68 PPL Junction box, 4.0 sq.mm cable with MC4 solar connector, conversion efficiency shall not be less than 22.21 % on STC, performance warranty for their output peak watt capacity > 90% at the end of 10 years and > 80% at the end of 25 years.
(b) Inverter / PCU: MPPT integrated, IGBT/MOSFET based and microprocessor/ DSP controlled Power Conditioning Unit (PCU) of AC nominal power output rating equal or greater than the required KWp of the module in IP-65 Enclosure, of 250-1500 V DC Input voltage range and 400 V AC, TPN, 50Hz +/- 2.5 Hz, Efficiency 97%, THD <3%, Overloading capacity/10%, remote monitoring facility and PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.
(c) Module mounting structure: MMS Steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759, All bolts, nuts, fasteners shall be hot dip galvanized, MMS shall be designed and installed to withstand the speed for the wind zone of the location with factor of safety 1.5, STAAD report of structure to be submitted
(d) Array Junction Box / DCDB IP 65 AJB /Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. DC fuses with SPD type-II/MOV type surge arrester to be provided.
(e) ACDB: IP 65 ACDB/Enclosure mounted on MMS with Polyamide glands and MC4 Connectors and cable ferrules for identification. MCB/MCCB with SPD type-II/MOV type surge arrester to be provided.
(f) Earthing and Lightning protection: The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors (LAs). as per NFC17-102:2011/IEC 62305 standard and three no. of Earthing with suitable size earth conductor
(g) Solar meter and Cable: Laying of array cables to PCU/ DCDB unit along with supplying & fixing of necessary Gl raceways/MS conduit lugs and suitable size aluminium armoured cable from ACDB to Electrical panel (up to 50 Mtr.) Discom approved solar meter (Direct or CT operated) with suitable size IP65 enclosure or MIP box with CT. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications mentioned in tender documents and as per tender terms condition, approved drawing and direction of Engineer in-charge. | 1,000 | KWp | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.90 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
solarterms.pdf
Tender Documents • 3.75 MB
BOQ_1028635.xls
BOQ • 0.38 MB
Solar_merged.pdf
PDF • 1.68 MB
cori1.pdf
PDF • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .