Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.6 LAccepted-AOC | ₹78.6 L Quoted ₹78.8 L | L1 | Accepted-AOC Bidder quoted L1 rates |
| 2 | L2₹79.8 L+₹1.0 L (1.32%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹79.8 L+₹1.0 L (1.32%) | L2 | Rejected-Finance Bidder not quoted L1 rates |
| 3 | L3₹88.3 L+₹9.5 L (12.1%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | ₹88.3 L+₹9.5 L (12.1%) | L3 | Rejected-Finance Bidder not quoted L1 rates |
| 4 | L4₹92.8 L+₹14.0 L (17.8%)Rejected-Finance S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹92.8 L+₹14.0 L (17.8%) | L4 | Rejected-Finance Bidder not quoted L1 rates |
| 5 | L5₹98.5 L+₹19.7 L (25.0%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹98.5 L+₹19.7 L (25.0%) | L5 | Rejected-Finance Bidder not quoted L1 rates |
| Sl No | Description | Qty | Unit | AGRAWAL ASSOCIATES L2 | Star Electrical L1 | PARAMOUNT ELECTRICALS L4 | Vijaypower Generators Limited L7 | NATIONAL ENGINEERING CORPORATION L6 | Prasur Electricals & Engineering Co. L5 | Shri Sai Electricals L3 | SBS Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing upto 315 KVA capacity transformer for platform by disconnecting both HT and LT connections, including lifting, shifting, loading, unloading, transportation, and depositing the transformer in MES store yard from the work site, complete all as specified and as directed.
Note: All necessary tools & plants (T&P) required for dismantling shall be included in the quoted rate. | 4 | EACH JOB | 5,000 ₹20,000 Lowest | 15,000 ₹60,000 | 15,000 ₹60,000 | 6,000 ₹24,000 | 5,000 ₹20,000 Lowest | 11,500 ₹46,000 | 8,000 ₹32,000 | 25,000 ₹1,00,000 |
| 2.00 | Dismantling and carefully removing the existing plinth of size 2.0 m × 2.0 m × 1.60 m, comprising PCC 1:4:8 (Type D-2) lean concrete, fly ash brick masonry in CM 1:6, including top portion consisting of 100 mm thick PCC 1:2:4 (Type B-1) using 20 mm graded stone aggregates laid over 75 mm thick PCC 1:4:8 (Type D-2), laid over compacted moorum filling, including 10 mm thick plaster, dressing of sides, ramming of bottoms, excavation, getting out of excavated soil, and disposal of surplus excavated soil to a place not less than 50 m away, complete all as specified and as directed. | 4 | EACH JOB | 5,000 ₹20,000 | 2,500 ₹10,000 Lowest | 5,000 ₹20,000 | 50,000 ₹2,00,000 | 5,000 ₹20,000 | 7,500 ₹30,000 | 6,500 ₹26,000 | 20,000 ₹80,000 |
| 3.00 | M&L for construction of plinth of minimum size 2.0m x 2.0m x 2.2m for transformer by using 100 mm thick PCC 1:4:8 (2.5mx2.5mx0.1m approx) type D-2 as in lean concrete, brick masonary in CM 1:4, the top of the plinth shall consist of 150 mm thick reinforced ready mix concrete (RMC) ,grade M-30 (including 10mm TMT bars) , 10mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5mm all around upto and including 1.0m from the Edge of the plinth including excavation (3mx3mx0.6m approx), removal & of soil, filling with approx 0.35 Cum Moorum/red bajri complete all as specified and directed. | 4 | EACH JOB | 50,000 ₹2,00,000 | 60,000 ₹2,40,000 | 50,000 ₹2,00,000 | 78,000 ₹3,12,000 | 40,000 ₹1,60,000 | 18,500 ₹74,000 Lowest | 55,000 ₹2,20,000 | 80,000 ₹3,20,000 |
| 4.00 | Supply, installation, testing and commissioning of copper wound transformer step down, outdoor type complete with standard fittings, HT 22 KV 3 Phase, LT 0.433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 2021, minimum level 2, of capacity 250 KVA complete all as specified and directed. | 3 | EACH JOB | 13,00,000 ₹39,00,000 Lowest | 13,78,000 ₹41,34,000 | 17,00,000 ₹51,00,000 | 20,37,000 ₹61,11,000 | 20,00,000 ₹60,00,000 | 18,45,000 ₹55,35,000 | 17,25,000 ₹51,75,000 | 20,00,000 ₹60,00,000 |
| 4.01Continuous Rating : 250 KVA No-Load Voltage Ratio : 22 KV / 433 V Tapping on HV [%] : As per provision of latest BIS Standards Phase & Frequency : 3 Phase & 50 Hz Connection : Delta Star Vector Group : DYN 11 Cooling : ONAN Type : Outdoor Insulation : Class A NOTE : The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted against respective item is deemed to be included for the same: Terminal Arrangement: [a] LV Side: Cable Box & HV side : Open bare bush with LA and arcing horns protection [b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side. [c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil. [d] Routine tests mentioned in these tender documents and relevant IS are to be followed. | |||||||||||
| 4.02Fittings: [a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device. [b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug [c] Pressure Release Valve [d] Oil filling hole cum air release plug [e] Drain Valve cum Sampling Valve [f] Top Filter Valve with Plug [g] Rating Plate with Diagram Plate [h] Lifting lugs for Transformer [j] Lifting lugs for Core [k] Earthing Terminals [l] Thermometer Pockets [m] Silica Gel Breather [n] Explosion Vent [o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB [p] 100mm size Oil Temperature indicator, dial type with alarm and trip contacts [q] 100mm size Winding Temperature indicator, dial type with alarm and trip contacts [r] Buchholz Relay with 2 Shut-Off Valves | |||||||||||
| 5.00 | Supply,installation, testing and commissioning of copper wound transformer step down, outdoor type complete with standard fittings, HT 22 KV 3 Phase, LT 0. 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 2021, minimum level 2 of capacity 315 KVA complete all as specified and directed. | 1 | EACH JOB | 18,00,001 ₹18,00,001 | 16,40,000 ₹16,40,000 Lowest | 19,00,000 ₹19,00,000 | 22,14,000 ₹22,14,000 | 21,75,000 ₹21,75,000 | 19,88,500 ₹19,88,500 | 19,25,000 ₹19,25,000 | 22,65,000 ₹22,65,000 |
| 5.01Continuous Rating : 315 kVA No-Load Voltage Ratio : 22 KV / 433 V Tapping on HV [%] : As per provision of latest BIS Standards Phase & Frequency : 3 Phase & 50 Hz Connection : Delta Star Vector Group : DYN 11 Cooling : ONAN Type : Outdoor Insulation : Class A NOTE : The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted against respective item is deemed to be included for the same: Terminal Arrangement: [a] LV Side: Cable Box & HV side : Open bare bush with LA and arcing horns protection [b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side. [c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil. [d] Routine tests mentioned in these tender documents and relevant IS are to be followed. | |||||||||||
| 5.02Fittings: [a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device. [b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug [c] Pressure Release Valve [d] Oil filling hole cum air release plug [e] Drain Valve cum Sampling Valve [f] Top Filter Valve with Plug [g] Rating Plate with Diagram Plate [h] Lifting lugs for Transformer [j] Lifting lugs for Core [k] Earthing Terminals [l] Thermometer Pockets [m] Silica Gel Breather [n] Explosion Vent [o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB [p] 100mm size Oil Temperature indicator, dial type with alarm and trip contacts [q] 100mm size Winding Temperature indicator, dial type with alarm and trip contacts [r] Buchholz Relay with 2 Shut-Off Valves | |||||||||||
| 6.00 | M&L for earthing complete with galvanised 'steel earth plate electrode '60×60cm.× 6mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less'than 1.5 metres below normal 'ground level, connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron steel riveted to the earth plate. The earth strip protected by provision of GI medium grade pipe 40mm dia including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick RCC cover in 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of Phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No.3 of SSR Part I 2009 connected to earthing test 'point all as specified or indicated and connected to lift machine as indicated 'including testing on completion complete all as specified and directed by Engr-in-Charge.
NOTE: Galvanized iron strip 32 mm × 6 mm and GI pipe of 40 mm bore (medium grade) for encasing the GI strip up to 7.50 m length per earthing shall be included in the quoted rate. | 18 | EACH JOB | 6,500 ₹1,17,000 | 8,000 ₹1,44,000 | 7,000 ₹1,26,000 | 7,200 ₹1,29,600 | 6,000 ₹1,08,000 | 9,500 ₹1,71,000 | 5,500 ₹99,000 Lowest | 8,000 ₹1,44,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
22 May 2026, 6:00 pmClosed
COMMANDER WORKS ENGINEER PUNE - 01
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85969 SPECIAL REPAIR / REPLACEMENT OF BER TRANSFORMERS INCLUDING CONNECTED ACCESSORIES AND PROVISION OF STANDBY HT UG CABLE UNDER GE (SOUTH) PUNE
2026_MES_761931_1
85969 CWE PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (SOUTH)
₹1.9 L
Yes
12 Aug 2026
24 Apr 2026
29 May 2026
24 Apr 2026
22 May 2026
15 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing upto 315 KVA capacity transformer for platform by disconnecting both HT and LT connections, including lifting, shifting, loading, unloading, transportation, and depositing the transformer in MES store yard from the work site, complete all as specified and as directed.
Note: All necessary tools & plants (T&P) required for dismantling shall be included in the quoted rate. | 4 | EACH JOB | - | - |
| 2 | Dismantling and carefully removing the existing plinth of size 2.0 m × 2.0 m × 1.60 m, comprising PCC 1:4:8 (Type D-2) lean concrete, fly ash brick masonry in CM 1:6, including top portion consisting of 100 mm thick PCC 1:2:4 (Type B-1) using 20 mm graded stone aggregates laid over 75 mm thick PCC 1:4:8 (Type D-2), laid over compacted moorum filling, including 10 mm thick plaster, dressing of sides, ramming of bottoms, excavation, getting out of excavated soil, and disposal of surplus excavated soil to a place not less than 50 m away, complete all as specified and as directed. | 4 | EACH JOB | - | - |
| 3 | M&L for construction of plinth of minimum size 2.0m x 2.0m x 2.2m for transformer by using 100 mm thick PCC 1:4:8 (2.5mx2.5mx0.1m approx) type D-2 as in lean concrete, brick masonary in CM 1:4, the top of the plinth shall consist of 150 mm thick reinforced ready mix concrete (RMC) ,grade M-30 (including 10mm TMT bars) , 10mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5mm all around upto and including 1.0m from the Edge of the plinth including excavation (3mx3mx0.6m approx), removal & of soil, filling with approx 0.35 Cum Moorum/red bajri complete all as specified and directed. | 4 | EACH JOB | - | - |
| 4 | Supply, installation, testing and commissioning of copper wound transformer step down, outdoor type complete with standard fittings, HT 22 KV 3 Phase, LT 0.433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 2021, minimum level 2, of capacity 250 KVA complete all as specified and directed. | 3 | EACH JOB | - | - |
| - | Continuous Rating : 250 KVA
No-Load Voltage Ratio : 22 KV / 433 V
Tapping on HV [%] : As per provision of latest BIS Standards
Phase & Frequency : 3 Phase & 50 Hz
Connection : Delta Star
Vector Group : DYN 11
Cooling : ONAN
Type : Outdoor
Insulation : Class A
NOTE : The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted against respective item is deemed to be included for the same:
Terminal Arrangement:
[a] LV Side: Cable Box & HV side : Open bare bush with LA and arcing horns protection
[b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side.
[c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil.
[d] Routine tests mentioned in these tender documents and relevant IS are to be followed. | - | - | - | - |
| - | Fittings:
[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.
[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug
[c] Pressure Release Valve
[d] Oil filling hole cum air release plug
[e] Drain Valve cum Sampling Valve
[f] Top Filter Valve with Plug
[g] Rating Plate with Diagram Plate
[h] Lifting lugs for Transformer
[j] Lifting lugs for Core
[k] Earthing Terminals
[l] Thermometer Pockets
[m] Silica Gel Breather
[n] Explosion Vent
[o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB
[p] 100mm size Oil Temperature indicator, dial type with alarm and trip contacts
[q] 100mm size Winding Temperature indicator, dial type with alarm and trip contacts
[r] Buchholz Relay with 2 Shut-Off Valves | - | - | - | - |
| 5 | Supply,installation, testing and commissioning of copper wound transformer step down, outdoor type complete with standard fittings, HT 22 KV 3 Phase, LT 0. 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:1180 2021, minimum level 2 of capacity 315 KVA complete all as specified and directed. | 1 | EACH JOB | - | - |
| 5.01 | Continuous Rating : 315 kVA
No-Load Voltage Ratio : 22 KV / 433 V
Tapping on HV [%] : As per provision of latest BIS Standards
Phase & Frequency : 3 Phase & 50 Hz
Connection : Delta Star
Vector Group : DYN 11
Cooling : ONAN
Type : Outdoor
Insulation : Class A
NOTE : The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted against respective item is deemed to be included for the same:
Terminal Arrangement:
[a] LV Side: Cable Box & HV side : Open bare bush with LA and arcing horns protection
[b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side.
[c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil.
[d] Routine tests mentioned in these tender documents and relevant IS are to be followed. | - | - | - | - |
| 5.02 | Fittings:
[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.
[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug
[c] Pressure Release Valve
[d] Oil filling hole cum air release plug
[e] Drain Valve cum Sampling Valve
[f] Top Filter Valve with Plug
[g] Rating Plate with Diagram Plate
[h] Lifting lugs for Transformer
[j] Lifting lugs for Core
[k] Earthing Terminals
[l] Thermometer Pockets
[m] Silica Gel Breather
[n] Explosion Vent
[o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB
[p] 100mm size Oil Temperature indicator, dial type with alarm and trip contacts
[q] 100mm size Winding Temperature indicator, dial type with alarm and trip contacts
[r] Buchholz Relay with 2 Shut-Off Valves | - | - | - | - |
| 6 | M&L for earthing complete with galvanised 'steel earth plate electrode '60×60cm.× 6mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less'than 1.5 metres below normal 'ground level, connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron steel riveted to the earth plate. The earth strip protected by provision of GI medium grade pipe 40mm dia including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick RCC cover in 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of Phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No.3 of SSR Part I 2009 connected to earthing test 'point all as specified or indicated and connected to lift machine as indicated 'including testing on completion complete all as specified and directed by Engr-in-Charge.
NOTE: Galvanized iron strip 32 mm × 6 mm and GI pipe of 40 mm bore (medium grade) for encasing the GI strip up to 7.50 m length per earthing shall be included in the quoted rate. | 18 | EACH JOB | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
85969TenderDocs.pdf
Tender Documents • 4.83 MB
BOQ_853485.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .