Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹32.7 L+₹3.9 L (13.5%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹41.9 L+₹13.1 L (45.2%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
16 Sept 2023, 6:00 pmClosed
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/MAINT OF DG SETS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2023_MES_614451_1
8123/SAR-42/2023-24
Open Tender
Civil Works
Item Rate
333 days
GE (AF) SARSAWA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(AF) SARSAWA
₹90,000
Yes
10 Oct 2023
19 Aug 2023
23 Sept 2023
19 Aug 2023
16 Sept 2023
2 Sept 2023
19 Aug 2023 - 2 Sept 2023
Amount
Receiving Electrical & Mechanical complaints related to DG sets installed at AFS, Sarsawa allied units from complaints section/ JE E&M/ Engineer-in-Charge in written or by telephoically & attending the same within 2 hrs. This item is inclusive of all preliminary work like opening of connectios, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues, removing air lock (if any), reconnecting the DG set back for proper functioning. Part shall be measured & paid separately under respective item of schedule. Note : Non compliance of attending breakdown & complaints within 2 hours after notification of the complaint will attract penalty @ Rs.1000/- per complaint/day shall be recovered from contractor's payment for each complaint so notified. contractor shall deploy sufficient resources along with personnel safety equipments to keep all the DG sets functional complete all as specified and directed
Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 02 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos. (f) Bendex assembly – 01 No (g) Tension sleeve – 01 No. (h) Gear assembly – 01 No.
All as per Item No.2 above but 24 Volts DC capacity complete all as specified and directed.
Supply only in replacement of Governor assembly for DG Set capacity 100 KVA to 200 KVA as per existing Make all as specified and directed by Engr-in-Change.
Supply only in replacement of Governor assembly for DG Set capacity 30 to 63 KVA as per existing all as specified and directed by Engr-in-Change.
De-coupling of Engine from alternator of DG set capaciity 30 to 63 KVA, removal from canopy and loading with hydra for transportation to workshop complete for repair/ overhauling including replacement of following items and refixing the same in position complete after repair work all as specified and directed
Supply only of the following new parts listed from srl No. 07 to 22 for Engine assembly repaired under Schedule `A' item No 6 above :- (Note :- Fixing element of these items including lathe work if any is included under the rates quoted by the contractor for Schedule `A' item No 6 Piston assembly suitable for DG set capacity 30 to 63 KVA
Main/ Began bearing set suitable for DG set capacity 30 to 63 KVA
Connecting rod bush suitable for DG set capacity 30 to 63 KVA
Thrust Washer suitable for DG set capacity 30 to 63 KVA
Valve set inlet and exhaust suitable for DG set 30 to 63 KVA
Valve guide suitable for DG set 30 to 63 KVA
Cylinder liner suitable for DG set 30 to 63 KVA
Piston ring suitable for DG set 30 to 63 KVA
Timming oil seal suitable for DG set 30 to 63 KVA
Connecting rod suitable for DG set 30 to 63 KVA
Main oil seal suitable for DG set 30 to 63 KVA
Gasket kit suitable for DG set 30 to 63 KVA
PC nozzel suitable for DG set 30 to 63 KVA
PC nozzel banjo bolt suitable for DG set 30 to 63 KVA
Valve stamp seal suitable for DG set 30 to 63 KVA
Turbocharger assembly suitable for DG set 30 to 63 KVA
De-coupling of Engine from alternator of DG set capaciity 100 to 200 KVA, removal from canopy and loading with hydra for transportation to workshop complete for repair/ overhauling including replacement of following items and refixing the same in position complete after repair work all as specified and directed
Supply only of the following new parts listed from Srl No 25 to 39 suitable for Engine assembly repaired under Schedule ‘A’ item No 23 above :-” (Note :- Fixing element of these items including lathe work if any is included under the rates quoted by the contractor for Schedule `A' item No 23 Piston assembly suitable for DG set capacity 100 to 200 KVA
Main/ Began bearing set suitable for DG set capacity 100 to 200 KVA
Coneccting rod bush suitable for DG set capacity 100 to 200 KVA
Thrust Washer suitable for DG set capacity 100 to 200 KVA
Valve set inlet and exhaust suitable for DG set 100 to 200 KVA
Valve guide suitable for DG set 100 to 200 KVA
Cylinder liner suitable for DG set 100 to 200 KVA
Piston ring suitable for DG set 100 to 200 KVA
Timming oil seal suitable for DG set 100 to 200 KVA
Connecting rod suitable for DG set 100 to 200 KVA
Main oil seal suitable for DG set 100 to 200 KVA
Gasket kit suitable for DG set 100 to 200 KVA
PC nozzel suitable for DG set 100 to 200 KVA
PC nozzel banjo bolt suitable for DG set 100 to 200 KVA
Valve stamp seal suitable for DG set 100 to 200 KVA
Turbocharger assembly suitable for DG set 100 to 200 KVA
Supply only in replacement of Self starter 24 volts for DG set Upto 200 KVA Make -Lucas complete all as specified and directed
Supply only in replacement of Self starter 12 volts for DG set Upto 200 KVA Make -Lucas complete all as specified and directed
Disconnecting and taking out the radiator of under mentioned capacity of DG sets strip opening completer radiator assembly, cleaning of tubes with using de-scaling solution or pressure pump, including soldering / gas welding of leakage of tubes. Cutting the rusted portion of in let or out let tubes including gas welding of new MS water tubes assembling the complete radiator including replacement of gasket, hose pipe with clamps nut bolts, and testing for making it leak proof including oiling/servicing of water cooling assembly , replacing unserviceable parts, re-assembling and fixing the same in position and testing the system complete all as specified and directed by Engineer-in-Charge :- (a) 30KVA to 63 KVA
All as per Serial Item No 42 here-in-above but for 100 KVA to 200 KVA DG Set
Supply only in replacement of air cleaner filters for DG Set capacity 30 to 63 KVA complete all as per sample specified and as directed
All as per Serial Item No 44 here-in-above but for 100 KVA to 200 KVA DG Set
Opening the coupling of DG Set of capacity 30 to 63 KVA, dismentling the outer cover & taking out the fly wheel ring and transport to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair complete all as specified & directed.
All as per Serial Item No 46 here-in-above but for 100 KVA to 200 KVA DG Set
Supply only in replacement of AVR complete all as specified and as directed DG Set of capacity up to 200 KVA Make: Kirloskar/Cummins/Ashok Layland.
Supply only in replacement V Belt/Grooved for the DG Set of Capacity 35 to 63 KVA complete all as specified and directd. Make : DUNLOP/MRF/JK
All as per item No 20 above but for capacity of DG Set 100 to 200 KVA complete alkl as specified and directed. Make : DUNLOP/MRF/JK
Supply only in replacement of new alternator (A 115, 12 V 35 Amp) all as specified & directed. Make: Lucas/Kirloskar
Supply only in replacement of Neon lamp for high & low voltage complete all as specified and as directed.
Supply only in distilled water in sealed cane for batteries complete all as specified and as directed
Supply only in replacement of fuel tank cap with locking arrangement as per matcing to existing complete all as specified and directed
Supply only in replacement of radiator cap with chain as per matcing to existing complete all as specified and directed
Supply only in replacement of fuel pipe length of 1 Mtr alongwith locking clamp benzo bolt for Diesel tank as per matcing to existing complete all as specified and directed
Supply in replacement of butterfly hinges for canopy as per existing size complete all as specified and directed
Refixing the Genrating Set doors with provn of butterfly hinges. After repir of door as per matcing to existing complete all as specified and directed
Supply in replacement door rod bush as per matcing to existing complete all as specified and directed
Supply in replacement high pressure pipe HA294 complete all as specified and directed
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm complete all as specified and directed
Supply only in replacerment of battery brass terminal (Heavy duty) comple all as specified and directed by Engr-in-Change
Remoulding of battery post terminal as per existing size complete all as specified and directed by Engineer-inChange
Supply in replacement Radiator hose pipe of size 50mm dia with clamp for DG Set complete all as specified and directed
Preparation of existing surface of D.G. Set at various locations capacity 30 KVA to 100 KVA by scraping out the old existing peeled off paint layer, filling the cavities with suitable filler, making the surface smooth and applying two coats of synthetic enameled paint by spray machine including writing necessary details of D.G. Set i.e. SM No. & MES No. in the pattern and style with using synthetic enameled white paint complete as directed by Engineer-in-Charge.
All as per Serial Item No 65 here-in-above but for 100 KVA to 200 KVA DG Set
Supply only on load change over switch in replacement cap 63 Amps 415 VOLT with SHEET ENCLOSER complete all as specified and directed make: Havells/L&T/ Schneider/ABB/ Indo Asian
Supply only on load change over switch in replacement cap 100 Amps 415 VOLT with SHEET ENCLODER complete all as specified and directed Make: Havells/L&T/ Schneider/ABB Indo Asian
Supply only on load change over switch in replacement cap 200Amps 415 VOLT with SHEET ENCLOSER complete all as specified and directed make: Havells/L&T/ Schneider/ABB Indo Asian
Supply only new current transformer (CT)coil of ratio as per matching to existing all as specified and directed.
Supply only in replacement LED Indiator lamp complete all as specified and directed L&T/BCH/C&S
Supply only in replacement Push butten complete all as specified and directed L&T/BCH/C&S
M & L for Heavy duty lead acid battery 12 Volts, 180/150 AH with electrolyte fully charged battery connecting and fixing at its position complete all as specified and directed. Make : Exide (Express) or equivalent make
M & L for Heavy duty lead acid battery 12 Volts, 80 AH with electrolyte fully charged battery connecting and fixing at its position complete all as specified and directed. Make : Exide (Express) or equivalent make
Supply only in replacement of control wire FR LS copper conductor 10 core PVC insulated flexible cable 2.5 Sqmm all as specified and directed.
Supply only in replacement of DWC pipe 25mm dia all as specified and directed by Engineer in Change
S & F in replacement of Automatic Battery Charging 12/24 volts for charging of batterys up to 180 AH, operating Input voltage 170v to 270V, Forced air coiled with high input and output isolation 3000V AC and High Surge protection,overload,over voltage protection with input current 2.6 Amp at 230 Volt AC all as specified and directed.
M & L for repairs/welding of various portion of DG set and its foundation, exhaust system, radiator fan assembly, protection guard etc. complete all as specified and directed by Engineer-in-Charge.
Supply only of the following new parts suitable for water cooling assembly of DG Set repaired above item No 81 above :- Rubber hose pipe set complete for 30 to 63 KVA DG set complete all as specified and directed
All as per Serial Item No 82 here-in-above but Water pump assembly set complete for 30 to 63 KVA DG set complete all as specified and directed
All as per Serial Item No 82 here-in-above butRubber hose pipe set complete for 100 KVA to 200 KVA DG set complete all as specified and directed
All as per Serial Item No 82 here-in-above but Water pump repair kit set complete for 100 KVA to 200 KVA DG set complete all as specified and directed
Taking out carefully unserviceable fuel injector pump assembly for 30 to 63 KVA DG set cleaning/ oiling/servicing fuel injector pump assembly, recalibration of Fuel Injector Pump after replacing unserviceable nozzles, re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly all as specified and directed by Engineer-in-Charge. (NOTE :- (i) Repairs/servicing / reassembling and testing of Fuel injector pump shall be carried out through a authorised service center on fully automatic testing machine. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as supply only but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Supply only of the following new parts listed from Srl No 88 to 106 suitable for Engine assembly repaired under Schedule ‘A’ item No 86 above :-” (Note :- Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 86) Kit Injector barrel plunger as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Gasket Governor set as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Ball Bearing as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Nozzles with copper washers as per matching to existing to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Gasket fuel pump as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Screen filter as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Ball check as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Gasket Injector as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Seal ‘O’ ring as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Pump gear fuel as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Shaft fuel pump drive as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Shaft tachometer drive as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Bushing tachometer drive as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Seal key way as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Plunger Governor as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Bearing thrust as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Plug Injector orifice as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Seal dust as per matching to existing complete all as specified and directed
All as per Serial Item No 87 here-in-above but Kit seal as per matching to existing complete all as specified and directed
Taking out carefully unserviceable fuel injector pump assembly for 100 to 200 KVA DG set cleaning/ oiling/servicing fuel injector pump assembly, recalibration of Fuel Injector Pump after replacing unserviceable nozzles, re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly all as specified and directed by Engineer-in-Charge. (NOTE :- (i) Repairs/servicing / reassembling and testing of Fuel injector pump shall be carried out through a authorised service center on fully automatic testing machine. (ii) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs etc. (iii) The quoted rates of contractor are deemed to be included cost of transportation to and fro authorized service centre.
Supply only of the following new parts listed from Srl No 108 to 126 suitable for Engine assembly repaired under Schedule ‘A’ item No 106 above :- (Note :- Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 106) Kit Injector barrel plunger as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Gasket Governor set as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Ball Bearing as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Nozzles with copper washers as per matching to existing to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Gasket fuel pump as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Screen filter as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Ball check as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Gasket Injector as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above butSeal ‘O’ ring as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Pump gear fuel as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Shaft fuel pump drive as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Shaft tachometer drive as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Bushing tachometer drive as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above butSeal key way as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Plunger Governor as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Bearing thrust as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Plug Injector orifice as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Seal dust as per matching to existing complete all as specified and directed
All as per Serial Item No 107 here-in-above but Kit seal as per matching to existing complete all as specified and directed
M&L for preventive maintenance/servicing of AMF panel of DG set of Capacity 30 to 63 KVA within an interval of three month upto the date of completion comprising by removal of dust/dirt/carbon particles by air blower, tighting of loose connection, replacement of worn out wires, lugs, setting of relay timer switch checking AC/DC circuits and replacement of unserviceable control wiring with 1.5 Sqmm, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694 testing the AMF panel on full load after completion of repairs all as specified and directed by Engineer-in-Charge. Note : The quoted rates of the contractor are deemed to include for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch `A’ as `supply only ‘ but quoted rates are inclusive of replacement of small/minor parts such as nuts, bolts, washers/lugs/gaskets etc.
All as per Serial Item No 126 here-in-above but for 100 KVA to 200 KVA DG Set
Supply only the following spares/parts/ components listed from Srl No. 129 to 147 of AMF Panels repaired item No 126 & 127 above. Note : (i) Fixing & testing element of the following items is deemed to be included in the rates quoted by the contractor for respective item no 127 & 128 above (ii) Contractor shall have no claim on account of variation of quantities of following items or non execution of the item(s). Electronic timer, type ET-100, suitable of 240 Volts, 50 Hz, AC supply, for 0 -10 seconds (ON delay). (Make : L&T/PIC/Aditya Electronic)
Electronic timer, suitable of 240 / 415 Volts, 50 Hz, AC supply, for 0-60 seconds (OFF delay). (Make : L&T / PIC / Aditya Electronic) complete all as specified and directed
Power Contactor, 3 pole, coil voltage 415 / 440 Volts, 50 Hz with 2 NO + 2 NC auxiliary contacts, having current rating (AC3) of 225 Amps at 415 volts equivalent of make Siemens / GE/BCH/L&T complete all as specified and directed
Power Contactor, 3 pole having current rating (AC3) of 200 Amps at 415 Volts equivalent of make Siemens / L&T / BCH/GE. complete all as specified and directed
Pla relay 24 Volts DC, 11pin, 2 change over, cat part No. 2C/O – MPC -24D of pla complete all as specified and directed make or equivalent of Eagle man.
Bimetal overload relay type MNX with relay range 24 – 40 Amps suitable for 3 phase 415 volts, AC supply complete all as specified and directed
Electronic DC timer suitable for 12/24 Volts DC supply, for 0-60 seconds. (on delay).complete all as specified and directed (Make : L&T / PIC / Aditya Electronic)
Under voltage relay suitable for 3 phase 415 volts, AC supply (Make : PIC / Aditya Electronic )
Engine starting relay with sequence timer & Master timer suitable for 12 / 24 Volts DC supply. (Make : PIC / Aditya Electronic)
Indicating lamps neon type with holder for 12 / 24 volts DC supply (RYB) (Make : L&T/BCH or equivalent.
Electronic timer, suitable of 240 / 415 Volts, 50 Hz, AC supply, for 0-154.01 seconds (ON delay). (Make : L&T / PIC / Aditya Electronic)
Ammeter 0-200 Amp/ 0-150 Amps/ 0-100 Amps, 96mm X 96mm, electromechanical type suitable for existing CTs of class 1.0 (Make : AE/IMP/Meco / Simco/Rishab)
Voltmeter 0-50 Volts, 96 mm X 96mm, electromechanical type for measuring DC supply. (Make : AE/IMP/Meco / Simco/Rishab) complete all as specified and as directed.
Contractor MNX-95 complete all as specified and as directed.
Contractor MNX-110 complete all as specified and as directed.
Contractor MNX-140 complete all as specified and as directed.
Contractor MNX-325 complete all as specified and as directed.
Contractor MNX 95 spare Coil 240 V, %0 Hz complete all as specified and directed by Engineer in Change .
Dismantling and taking out old unserviceable Dynamo assembly of 63 KVA to 200 KVA Three phase 50 HZ capacity of DG set for repair and replacement of defective parts like rotar assembly, Carbon brush, Bearing and rewinding to stator with suitable gauge of copper wire, sleeve, glass paper and Varnish, soldering to commutator assembly, reassembling & fixing the same in position and testing the dynamo assembly all as specified and directed by Engineer-in-Charge.
General servicing of DG set of any make which include taking down and replacement/ repair of diesel filter, oil filter, lubricating Engine oil (15W40 Make : Valvoline), rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, gaskets, burnt parts, measuring earth resistance values (as required) etc and tightening of nuts, bolts, washers, greasing, etc for proper running of DG sets complete all as specified and directed. Capacity : 35 to 63 KVA
All as per Serial Item No 148 here-in-above but capacity of DG set 100 to 200 KVA complete all as specified and directed.
Supply only coolent for radiator of DG sets upto 400 KVA Make: Bosch sealed Packing complete all as specified and directed.
Supply only Rain guard for DG Set canopy door comple all as specified and directed by Engineer-in-Change
De-coupling of alternator from Engine, transportation to workshop, complete dismantling washing to remove carbon particls, rewinding of arrmature /field coils/stator with copper wire/strip of size as per original with insulation, pre-heating in oven, varnishing and re-heating, assembly of alternator, testing and coupling with engine at site and full load testing complete all as directed by Engr-in-Charge
Supply only in replacement of Ball bearing up to 63 KVA DG Set as per existing size all as specified and directed by engineer in Change
Supply only in replacement of Ball bearing up to 100 to 200 KVA DG Set as per existing size all as specified and directed by engineer in Change
M&L for remetalling of bearing seat on rotor shaft/in end cover housing machining on lathe to match with the existing size of bearing complete all as specified and directed by the engr-in-Change
Comprehensive preventive and periodical maintenance of 400 KVA DG Set with Engine Make Cummins and Alternatr Make Stamford as per OEM Standards maintenance Schedule. Note : AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to department within 15 days of issue of work order failing which penality @ Rs 500 per day shall be imposed. (ii) following material shall be mesured and paid separately under respective items of Sch
Material for 400 KVA DG Set listed from Srl No. 157 to 164 Element , lubrication oil filter Item No 3401544 complete all as specified and directed.
All as per Serial Item No 157 here-in-above but Filter Fuel Item No 5317717 complete all as specified and directed.
All as per Serial Item No 157 here-in-above but Separ ator fuel water Item No 4345001 complete all as specified and directed.
All as per Serial Item No 157 here-in-above but Element inner Item No 4957709 complete all as specified and directed
All as per Serial Item No 157 here-in-above but Element outer Item No 4957708 complete all as specified and directed
All as per Serial Item No 157 here-in-above but Element element crn resistor Item No 4072352 complete all as specified and directed
All as per Serial Item No 157 here-in-above but Valvo Line Premium Blue 7800 Plus Item No 505441 complete all as specified and directed
All as per Serial Item No 157 here-in-above but Inhibitor, corrosion Item No 4926654 complete all as specified and directed
Comprehensive preventive and periodical maintenance of 320 KVA DG Set with Engine Make Cummins and Alternatr Make Stamford as per OEM Standards maintenance Schedule. Note : AMC to be carried out through OEM only. MOU to this effect shall be submitted by the contractor to department within 15 days of issue of work order failing which penality @ Rs 500 per day shall be imposed. (ii) Following material shall be mesured and paid separately under respective items of Sch
Material for 320 KVA DG Set listed from Srl No. 166 to 174 Element , lubrication oil filter Item No 3401544 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Filter Fuel Item No 3973232 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Filter Fuel Item No 3973233 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Resistor corrosion Item No 4058965 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Element Filter Item No A041R279 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Element Air Filter Item No A041R273 complete all as specified and directed
All as per Serial Item No 166 here-in-above but inhabitor, corrosion 5liters Item No 3816986 complete all as specified and directed
All as per Serial Item No 166 here-in-above butt Valvo Line Premium Blue 7800 Plus Item No 505441 complete all as specified and directed
All as per Serial Item No 166 here-in-above but Foil sealed test strips cc2602B Item No 3403800 complete all as specified and directed
Supply only in replacement of radiator assembly for DG set of 35 KVA as per existing make all as specified and directed by Engineer-in Change
Supply only in replacement of radiator assembly for DG set of 63 KVA as per existing make all as specified and directed by Engineer-in Change
Supply & Fixing G.I strip 32x6mm with saddles & fixing screw etc complete all as specified and directed by Engineer in Change
M & L for earthing with galvanised steel earth plate 600mm x 600mm x 6 mm thick electrode burried directly in ground (earth pit not less than 3.0 m deep below ground level) with top edge of the plate not less than 2.4 m below normal ground level connected to galvanised iron strip 32mm x 6mm by means of brass / gunmetal bolts, nuts and washers of all as shown in electrical plate No 3 of SSR Part-I connected to test points including PCC earth pit having outer dimension of 60cm x 60cm x 60cm and internal dimension of 30cm x 30cm x 30cm with CI cover, GI protection pipe 40mm dia. light grade for earth lead from earth plate to testing point and for watering pipe 20mm dia medium grade, with one number funnel duly welded wire mesh, filling of charcoal and salt surrounding the earth plate incl. excavation and earth work in any type soil complete all as specified and directed including testing on completion.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar Complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness Complete all as specified and directed.
M/LCement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete.
M&L for coloured designer Chequered cement concrete tiles 300X3000X25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments complete all as specified and as directed by Engr-in-Charge
M&L for 20mm thick screed bed or bedding layer of mortar CM 1:6 for laying floor finishes complete all as specified and as directed by the Engr-in-charge.
Supplying and laying in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed
SUBHASH CHAND CONTRACTOR
Gupta Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .