Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹6.6 L+₹8,165.31 (1.25%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID VALUE | |
| 3 | L3₹6.6 L+₹8,818.54 (1.35%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID VALUE |
Tender Value
₹6.5 L
EMD Value
₹13,065
Closing Date
24 Jan 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
HMC 4 MG ROAD HOWRAH 711101
Renovation works of sludge pump house with surrounding at HWW Padamapukur under Howrah Municipal Corporation (2nd Call)
2025_MAD_979125_5
HMC/HWW/P-07/2025-26
Open Tender
CIVIL WORKS
Percentage
30 days
HMC AREA
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹13,065
27 Apr 2026
24 Dec 2025
27 Jan 2026
24 Dec 2025
24 Jan 2026
24 Dec 2025
Dismanlting all types of masonry excepting cement concrete plain or reinforced,stacking serviceable materials at site and removing rubbish as directed within a led of 75m. a) in ground floor including roof [Ref : P.W.D.(Bldg.), Page-10, Item No. 01]
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof (a) upto 150 mm. thick [Ref : P.W.D.(Bldg.), Page-10, Item No. 01]
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. a) in ground floor including roof [Ref : P.W.D.(Bldg.), Page-10, Item No. 03]
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. [Ref: P.W.D (Bldg) 2017, Page - 11, Item-10]
Labour for Chipping of concrete surface before taking up Plastering work. [Ref: P.W.D (Bldg) 2017, Page - 192,Item - B.(1)]
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm [Ref : P.W.D.(Bldg) 2017, Page - 1, Item-2(b]
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. [Ref : P.W.D.(Bldg.), Page- 1, Item-3.(a)]
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) [Ref : P.W.D.(Bldg.), Page-2, Item No. 4]
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. [Ref : P.W.D.(Bldg.), Page-14, Item No. 1]
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion [Ref: P.W.D (Bldg) 2017, Page - 23, Item.- 1.a]
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor [Ref: P.W.D (Bldg) 2017, Page - 16, Item.- 16]
st class bricks in cement mortar (1:4) (a) In foundation and plinth [Ref: P.W.D (Bldg) 2017, Page - 15, Item.- 7,(3rd Corrigenda)]
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. [P.W.D.(Bldg.). Page- 42, Item - 36.(a)]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL [Ref : P.W.D (Bldg) 2017, Page-43, 44 Item No. 40.a.(i).II]
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety [Ref: P.W.D (Bldg) 2017, Page-26 Item No- 10] Analysis no-15.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick [Ref : P.W.D.(Bldg.) Page-48, Item-14
Plaster with sand and cement mortar including rounding off corners or chamfering corners as directed and including raking out joints or roughening of concrete surface, curing with cost and carriage of all materials. (a)With 4 : 1 cement mortar. ii)20 mm thick plaster [Ref : P.W.D.(Bldg.), Page -189 Item-1 (3rd Corrigenda)]
Neat cement punning on cement plaster surface. [Ref : P.W.D.(Bldg.), Page -192, Item-15]
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) 1st class Best Indian teak. [Ref : P.W.D.(Bldg.). Page- 114, Item-1]
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. i) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm. (a) 1st class best Indian teak. [Ref: P.W.D.(Bldg.). Page- 117, Item - 1.(i).(a)]
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. ii) Grill weighing above 16 Kg./sq.mtr and above [Ref: P.W.D.(Bldg.). Page- 104, Item-13.(a).(i) & 3rd corri.]
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (c) 40mm X 6mm, 125mm Length [Ref: P.W.D.(Bldg.). Page- 140, Item-4.(C)]
Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete. 1.000 Each 1954.00 1954.00 [Ref: P.W.D.(Bldg.). Page- 143, Item-16.(b)]
Door stopper.(Brass) [Ref: P.W.D.(Bldg.). Page- 143, Item-19.(i)]
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark (vii) 100mm. X 58mm. X 1.90mm. [Ref: P.W.D.(Bldg.). Page- 140, Item-5.(vii)]
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (b) 250mm long [Ref: P.W.D.(Bldg.). Page- 142, Item-10.i.c.]
Supplying bubble free float glass of approved make and brand conforming toIS:2835-1 [Ref: P.W.D.(Bldg.). Page- 243, Item-9(v)]
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. [Ref : P.W.D.(Bldg.), Page-106, Item No.-18]
Supplying empty Cement bags in good condition. [Ref : P.W.D.(Road). Page- 336, Item-18.28]
Filling empty Cement bags with dry earth or sand,stitching the bag (cost of thread included) and carrying and placing them in position and all incidental charges complete but excluding cost of sand and gunny bags. [Ref : P.W.D.(Road). Page- 336, Item-18.29]
Supply of Silver Sand [Ref : P.W.D.(Bldg.). Page- 300, Item-6
Cleaning rubbish, sludge, weeds scum, liquid earth, mud etc.etc.from road side masonary drain/ hume pipe drain/ culvert etc. by mathor labour after removing concrete.Slab/manhole cover etc.without damaging the same and refixing the same properly after cleaning as necessary and removing the sludge etc.etc.by using iron pans,buckets including all labour, tools & plants including removing the spoils in dry condition and disposing the same by truck beyond the road side in conformity with municipal/corporation rules for such disposal including loading into truck and cleaning the road side in all respects as per direction of the Engineer in-Charge. [Ref : P.W.D.(S&P). Page- 1
Supplying, fitting and fixing in position FRP/GRP/COMPOSITE UV stabilizer Gully Pit Cover with high abrasion surface of 7mm top thicknes, density of 2KG/m³ of approved make with rim of approved make (Heavy type) (ii) 20 M.T. Gully pit cover (yard gully) with arrangement for opening of size Frame Clear Opening 640 mm X 240 mm. Cover Out to Out 700 mm X 300 mm. [Ref : P.W.D.(S&P.), Page -95, Item-11.(ii)]
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification andas per direction of the EIC. (In Ground Floor) i) Water based interior grade Acrylic Primer (b) Two Coats [Ref: P.W.D.(Bldg.). Page- 196, Item-7.(b).(i)]
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. iii) Two coats. [Ref: P.W.D.(Bldg.). Page- 196, Item-10]
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (b) Two Coats [Ref: P.W.D.(Bldg.). Page- 196, Item-8.(b)]
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion [Ref: P.W.D.(Bldg.). Page- 196, Item-7.(b)]
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. [Ref: P.W.D.(Bldg.). Page- 200, Item - 1.(b)]
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. [Ref: P.W.D.(Bldg.). Page- 200, Item - 1.(a)]
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : iv) Two coats (with any shade except white) [Ref: P.W.D.(Bldg.). Page- 201, Item -2.(b).(iv)]
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : iv) Two coats (with any shade except white) [Ref: P.W.D.(Bldg.). Page- 201, Item -2.(b).(iv)]
Dewatering by pumps including all leads, lifts and making all arrangements of disposal, where continuous flow of water from a source other than natural or ground water in encountered in case of emergency maintenance works related to leakage, breakage and making wet connections. 1200.000 Hp-Hr 33.00 39,600.00 [Ref:K.M.D.A.(W.S.) Page-82,Item No-6.1]
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge [Ref : P.W.D (Bldg) 2017, Page-12, Item No. 13]
Add 18% GST
Add 1% Cess
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tendernotice_2.pdf
PDF • 6.12 MB
BOQ_2386647.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .