Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 CrAccepted-Finance | ₹7.1 Cr | L1 | Accepted-Finance Being L1 |
| 2 | L2₹7.1 Cr+₹274.09 (<0.01%)Accepted-Finance | ₹7.1 Cr+₹274.09 (<0.01%) | L2 | Accepted-Finance Being L2 |
| 3 | L3₹7.1 Cr+₹673.43 (<0.01%)Accepted-Finance | ₹7.1 Cr+₹673.43 (<0.01%) | L3 | Accepted-Finance Being L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically non-responsive |
Tender Value
₹7.1 Cr
Closing Date
13 Sept 2021, 12:00 pmClosed
Chief Enginner, MOBEDS
3rd Floor Birla Building, Khurai Chingangbam Leikai, Imphal East
Infrastructure Development of Pettigrew College at Ukhrul District (Sh- Construction of 100 Bedded Girls Hostel)
2021_DMA_1514_1
MOBEDS-77/2021
Open Tender
Civil Works - Buildings
Item Rate
540 days
Ukhrul District
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Member Secretary, MOBEDS
Exempted
12 Nov 2021
2 Sept 2021
13 Sept 2021
2 Sept 2021
13 Sept 2021
2 Sept 2021
Amount
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5 m including getting out the excavated soil and disposal od surplus excavated soil as directed within a lead of 50 m (a) Hard/Dense Soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming andwatering, lead upto 50 m and lift upto 1.5 m.
Filling with sandy soil under floors including watering, ramming, consolidating and dressing complete
Providing and laying cement concrete in foundation and plinth excluding the cost of centering and shuttering in a).1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size)
Extra for providing and mixing water proofing materials in cement concrete work in the proportion recommended by manufactures
Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per sqm on damp-proof course after cleaning the surface with brushes and final with a piece of cloth lightly soaked in Kerosene oil.
Providing and laying in position specified grade of reinforced cement concreete excluding the cost of centering, shuttering, finishing and reinforcement -All work upto plinth level (a) 1:1:2(1 Cement : 1 k/coarse sand :2 graded stone aggregate 20 mm nominal size).
Reinforced Cement Concrete work in walls (any thickness) i/c attached pilasters, buttresses, plinth & string courses, fillets ,Column ,pillars ,abutments ,posts and struts etc.up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement (b).1:1.5:3 (1 Cement : 1.5k/coarse sand :3 graded stone aggregate 20 mm nominal size).Upto floor five level
Reinforced cement concrete work in suspended floors, roofs, landing, balconies,shelves,chajjas,lintels,bands,plain windowsill,Staircases and spiral staircase upto floor five level excluding the cost of centering, shuttering,finishing and reinforcement with (a) 1:1.5:3 (1 Cement : 1.5 k/coarse sand :3 graded stone aggregate 20 mm nominal size
Reinforcement for R.C.C. work i/c. bending, binding and placing in position complete.
.a) Thermo-Mechanically Treated bars.
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in (Using 12mm shuttering ply)
(a).Foundation, footing, bases of columns etc. and mass concrete.
(b).Sides and soffits of beams,beam haunchings,cantilevers girders,bressumers and lintel not exceeding 1 m in depth
(c ).Flat surface such as soffits of suspended floors,roofs landings and the like others floor etc.upto 200mm in thickness
(d ).Columns,pillars,posts and struts(Square,rectangular or polygon in plan)
( e).Stair cases with sloping or stepped, soffits i/c risers and stringers excluding landing
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete Cement mortar 1:6 (1 cement : 6 coarse sand) a).In Plinth
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:3 (1 cement: 3 k/coarse sand) a).In Plinth
Half brick masonry 2nd class (Local first class) in cement mortar
1:3 (1 cement: 3 sek /coarse sand) in superstructure. a).Ground Floor
b).First floor
c).Second floor
d).Mumty
Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position.a). Local best quality Uningthou a).Local best quality Uningthou
P/F 38 mm. thick panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright finished or black enamelled M.S. Iron butt hinges with necessary screws.
Providing 40 x 3 mm flat iron hold fast 40 cm long i/c fixing to frames with 10 mm dia bolts nuts & wooden plugs & embedding to cement concrete block 30 x 10 x 15 cm 1:3:6 (1 cement:3 coarse sand:6 stone aggregate 20 mm nominal gauge).
Providing and fixing Brass sliding bolts bright finished with nuts & screws etc. complete.a)300x12mm
P/F Brass Tower bolts(Barrel type) with screws etc, complete.a)250x10
Providing & fixing Brass handles with necessary screws etc. complete. a)125 mm
Providing & fixing bright finished brass hand drawn hooks and eyes..(a)150mm
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position.a).Uchan/Tairen/Tolhao/Khangra.
Corrugated G.I. sheet walling 24 B.G. i/c fitting and fixing to wooden frames with necessary screws and nails complete (frame work to be paid separately).
Supply & installation of stainless steel railing (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stinless steel nuts and bolts complete, i/c fixing the railing with necessary accessoties & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge
Providing & fixing in position collapsible steel shutters with vertical channels 20mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pulleys complete with bolts & nuts, locking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
Marble stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1cement: 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with - (a).White Marble slab 20 mm thick. a).60x60cm
10 mm thick marble tiles in risers of steps , skirting , dado walls and pillars laid on 10 mm thick base of cement mortar 1 : 3 ( 1 cement: 3 coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete
Extra for nosing in marble stone for treads
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. a).Size of Tile -600 x600mm.(Single Charged)-Non-Branded
Providing and laying Vitrified tiles in different sizes (thickness to be speciied by manufacturer ) ,with water absorption less than 0.08% and conforming to IS :15622 of approved brand & manufacturer ,in all colours and shade in skirting ,riser of steps,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 sekmai coarse sand), including grouting the joint with white cement & matching pigments etc.a).Size of Tile -600 x600mm.(single Charged)-Non-Branded
Providing and fixing 1st quality ceramic glazed wall tiles(colour) conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster 1:3 (1 cement:3 fine sand).
15 mm cement plaster 1:3 (1 cement:3Fine sand).
15 mm cement plaster 1:3 (1 cement:3fine sand) finished with a floating coat of neat cement.
Distempering (two or more coats) with oil bound washable distemper of
approved quality on new work I/c priming coat to give an even shade.
Finishing walls with weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Applying one coat of cement primer of approved quality on wall surface.
Providing and applying plaster of paris of 2mm thickness over plastered surface to prepare the surafce even and smooth complete.
Applying ready mixed priming coat pink primer of approved quality on wood work.
Applying ready mixed priming coat ( Red lead primer of approved quality ) on steel work..
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved quality in all shades on new work to give an even shade.
Painting (two or more coats) with synthetic enamel paint of approved quality all shades except black or chocolate on steel on new work to give an even shade.
CHLORINATED POLYVINYL CHLORIDE (CPVC) pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. including cutting chases and making good the walls etc. External work a).50mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Conceal work a).32mm dia
SANITARY FITTINGS COMPLETE
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: a).White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: a).White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
BRASS AND CP BRASS FITTINGS
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :a).15 mm nominal bore
Providing and fixing brass stop cock of approved quality. a).15 mm diameter
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. a).2000 litres net capacity storage tanks
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :a).Rectangular shape 453x357 mm
Providing and fixing 600 x 20 mm C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type )
Providing and fixing C.P. brass toilet paper holder
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
SH:-PVC Pipes and Fitting
Providing and fixing PVC soil ,waste and vent pipes.External a).100mm dia
Providing and fixing PVC vent cowl.a).100mm dia
Providing and fixing MS holder bat clamps of approved design to 100 mm HCI pipe socket i/c cost of cutting holes and making good the walls etc.
including cost of cutting holes and making good the walls etc.
Providing and fixing PVC soil ,waste and vent pipes.a).75mm dia
Providing and fixing PVC NAHANI TRAP.a).75mm
Providing and fixing grating of approved quality for Nahni trap.a).Stainless Steel
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.A).Flexible pipe--32 mm dia
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge.A).110mm dia
Supply and installation of water pump Tulu(Texmo) 1HP of approved quality.
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres Hard/Dense Soil
Filling available excavated earth(excluding rock) in trenches,plinth sides of foundation etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8(1 cement: 4course sand: 8 graded stone aggregate 40mm. nominal size
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering,shuttering,finishing and reinforcement-All work up to plinth level: 1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size).
Steel reinforcement for R.C.C work including straightening,cutting, bending, placing in position and binding all complete.a)Thermo mechanically treated bars
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in
(a).Foundation, footing, bases of columns etc. and mass concrete.
b).Flat surface such as suspended floor, roofs landings and the like floors etc. upto 200 mm in thickness
c).Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
Providing and fixing C.I. Cover frame (for manhole and chambers).a).600 mm x 450 mm (heavy duty)
Earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms lift upto 1.5metres including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres a).Hard/Dense Soil
Filling available excavated earth(excluding rock) in trenches,plinth sides of foundation etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering in 1:4:8(1 cement: 4course sand: 8 graded stone aggregate 40mm. nominal size
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering,shuttering,finishing and reinforcement-All work up to plinth level: 1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size).
Steel reinforcement for R.C.C work including straightening,cutting, bending, placing in position and binding all complete.a)Thermo mechanically treated bars
Providing form works i/c centering and shuttering so as to give a rough finish, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for in-situ reinforced concrete and plain concrete work in
(a).Foundation, footing, bases of columns etc. and mass concrete.
b).Flat surface such as suspended floor, roofs landings and the like floors etc. upto 200 mm in thickness
c).Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
Providing and fixing C.I. Cover frame (for manhole and chambers).a).600 mm x 450 mm (heavy duty)
Writing for light point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch, modular plate suitable size GI-Box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc. as reqd.
1. Group A
2. Group B
3. Group C
Wiring for light point/power plug point with 2x4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit along with 1 no. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc as reqd.
a) Light Plug Point
b) Power Plug Point
S/F suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 3 pin 5/6 am modular socket outlet and 5/6 amp modular switch, connection painting etc as reqd. (for light plugs to use in non residential building)
S/F suitable size GI box with modular plate and cover in front on surface or in recess i/c P/F 6 pin 15/16 and 5/6 amp modular socket outlet and 15/16 amp modular switch, connection painting etc as reqd. (for light plugs to use in non residential building)
Wiring for Circuit/Sub-main wiring along with earth wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc. as reqd.
1. 2x1.5mm2 + 1x1.5mm2 earth wire
2. 2X2.5mm2 + 1X2.5mm2 earth wire
3. 2x4mm2 + 1x4mm2 earth wire
4. 2x6mm2 + 1x6mm2 earth wire
S/F 20W, LED New E-Lite LED triyca batten tube fittings, Havells
S/F recessed 15 W LED Downlight with all accessories i/c connection etc.
S/F 56" sweep (1400 mm)AC ceiling fan complete with down rod, canopy, 3(three) blades but without regulator etc as reqd. (Make Bajaj / Usha or Similar)
Supplying and fixing stepped type electronic fan regulator on the existing PVC Switch box i/c connection etc as reqd.
S/F 450 mm sweep exhaust fan complete with all accessories i/c connection etc as reqd.
S/F Single Pole 5 amp to 32 amp. Rating 230 V 'B' series MCB for lighting & other load in the existing MCB DB complete with connection testing & commissioning etc. as reqd.
S/F 63 A double pole 240V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
S/F (following rating) double pole 230V moulded case circuit breakers (MCCB) AC-415V having a sensitive current upto 300MA in the existing MCB DB complete with connection testing and commissioning etc. as reqd. a) 100 Amp. 4 Pole 230V 300MA
S/F (following way) single/double pole and neutral, sheet steel MCB distribution board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphatised and powder pained including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
S/F of (the following) metal boxes with phenolic laminated sheet cover in front : a) 200mmx250mmx100mm deep
S/F bus bar chamber with four strips Cu bus bar of length 600mm suitable for 63A capacity complete with all accessories i/c connection, earthing the body etc. as reqd.
S/F wall mounted metal board of welded construction with minimum 35mmx35mmx6mm, angle iron frame work with 25mmx6mm flat iron as intermediate members i/c connection etc as reqd.
Earthing with copper earth plate 600mmx600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as reqd.
P/L earth connection from earth electrode with 4mm dia copper wire in 15mm dia G.I Pipe etc as reqd.
P/F 8 SWG dia copper wire on surface or in recessed for loop earthing along with existing surface/recessed conduit wiring/sub-wiring/cable etc. as reqd.
FIRE FIGHTING
Supply and installation of fire hydrant pipe as per required dia as in the following
150 mm dia
80 mm dia
Supply and fitting of cast iron butterfly valve
150 mm dia
Providing and installation of cast iron NRV 1.6 rating
150 mm dia
Supply and fitting of ms support
Supply and fitting of pressure gauge as per requirement
supply and installation of internal landing valve of 63 mm
Supply and installation of hose cabinet suitable for one hose pipe , branch pipe with front glass and fire code paints
Supply and installation of RRL hose pipe of 63 mm dia, 15 mtr long
Supply and installation of Hose drum with 20 mm RRL nozzle fitted
Supply and installation of branch pipe
Supply and installation of fire fighting pump
Supply and installation of fire fighting pump panel
Supply and installation of ABC type fire extinguisher 4 kg
Supply and installation of CO2 type fire extinguisher
Supply and installation of 2 way fire hydrant inlet
supply and installation of 25 mm gate valve
M/S Mingyao Ruivanao and co
M Gunananda Sharma
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .