Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹3.0 Cr+₹27.2 L (10.1%)Rejected-Finance JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | ₹3.0 Cr+₹27.2 L (10.1%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹3.1 Cr+₹38.0 L (14.1%)Rejected-Finance | ₹3.1 Cr+₹38.0 L (14.1%) | L3 | Rejected-Finance Being not lowest |
Tender Value
₹3.4 Cr
EMD Value
₹6.7 L
Closing Date
14 Feb 2022, 6:00 pmClosed
Col Jiagar Trivedi, SM
HQ CWE (AF) GUrgaon Old Palam ROad, Delhi Cantt - 110010
PROVISION OF PIPE LINE FOR USING TREATED WATER IN ARBORICULTURE AT AFSSR GURGAON UNDER GE (AF) GURGAON
2021_MES_482385_3
CWE/GGN/GT-18/2021-22
Open Tender
Civil Works
Lump-sum
540 days
AF Stn AFSSR
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (AF) Gurgaon
₹6.7 L
Yes
3 Mar 2022
17 Jan 2022
16 Feb 2022
17 Jan 2022
14 Feb 2022
31 Jan 2022
17 Jan 2022 - 30 Jan 2022
Amount
Sch 'A' Section I (Structure Work) under Srl No. 1.01 Note: These schedules are pre-priced by MES. Rates to be quoted by contractor after verify and workout their own rates as per detailed drawings enclosed. Department shall not entertain any claim due to any variation in the estimate and prepriced inserted by MES, if any.
Lump sum price worked out by the contractor for Structural Work as listed in Sch 'A' Section I (refer prepriced shedule attached seperately)
Sch 'A' Section II & III under Srl No. 3 & 4 These schedules are pre-priced by MES. Details of section II & III are given in Tender Documents
Lump sum price worked out by the contractor for SEWAGE SYSTEM as listed in Sch 'A' Section-II (refer prepriced shedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Section-III (refer prepriced shedule attached seperately)
MISCELLANEOUS ITEMS under Sch 'A' Section-IV are not prepriced by MES and item Rate to be quoted by contractor for each item.
Supply, erection, testing and commissioning of factory assembled and tested electric motor driven thee phase 415 Volt AC, 650 LPM of water as at minimum 50 mtr head and capacity not less than 40 HP comprising of heavy duty type split casing type centrifugal pump, Cast iron body with bronze impeller, casing ring, sleeves etc. coupled to TEFC SQ CASE (IE3 Efficiency) electric motor of suitable capacity 1500 RPM by means of flexible coupling and mounted on a common fabricated MS base frame and GI pipe heavy duty at suction and GI heavy duty delivery pipe of suitable size as reccomended by manufacturer upto suitable lenghth at suction end and delivery connection to header with necessary fittings . NOTE- (i) Cost of GI pipe heavy duty at suction and GI heavy duty delivery pipe of suitable size as reccomended by manufacturer upto suitable lenghth at suction end and delivery connection to header with necessary fittings shall be included in overall cost quoted (ii) COST OF FOUNDATIONS AS PER MANUFACTURERS RECCOMMENDED DRAWING WITH NUTS, BOLTS, ANTI VIBRATION PADS INCLUDED IN OVERALL RATES QUOTED.
M & L for trenchless boring under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size upto 150mm bore for protection of UG cables complete all as specified and as directed.
S&F, testing and comissioning flanged non-rising type cast iron foot valve of size 150 mm suitable for pressure rating duly drilled holes for fixing of nutss and bolts ISI marked and confirming to IS:4038 including rubber gasket, nutss, bolts, and washers complete all as specified and as directed. Note: Rate is included for Nuts & Bolts, flange etc.
M & L for Cast iron Air valves with two air outlets, 100 mm dia bore and fixing up in PPR water pipe mains including nuts & bolts, washer etc complete all as specified and directed.
M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep , from the top of MS cover fixed on PCC Base , top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class"B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessray earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed.
M&L for water pop up sprinkler head irrigation system for garden Lawn Patio 180 degree of dia 25 mm bore incluyding 0.5 mtr long 25 mm inner dia PP-R pipe, socket of any type and other fixing material for fixing with PP-R pipe all as directed and specified. Note: All fixing material is included in the unit rate. Sprinkler will be fixed ever 90 mm.
Supply, erection, testing and commissioning of Ozone Generator of capacity 40 gm/hr & Oxygen Concentrator with the following Technical specificaaion :- (a) Ozone Generator Design Basis Ozone Requirment : 40 gm/hr Method of Ozone Injection : Recirculation Based in Tank Ozone Generator Specifications Model Proposed : OZ-AIR®IMD 40-OXY Ozone Output : 40 gm/hr @ 60-80 gm/m3 Type of PSU : IGBT Based Corona Ozone generator Type of Di-electric : SS-316 L / Quartz (Air Cooled) Utilities & Requirments Power : 220-230 VAC / 50 Hz / 1Ø / 0.4 KW Feed Gas Requirment Purity & Flow Rate : 5 LPM~0.3 m3/hr @ 90 % ± 2% MOC of Enclouser : SS-304L Dimensions & Weight : 700 X 250 X 750 / 55 kgs ; make: ozonic/creative OZ-AIR
(b) Oxygen Concetrator Oxygen Concetrator Specifcations Model Proposed : OZ-AIR®HG-5 Oxygen Output : 5 LPM @ 93% + 2% Power : 220-230 VAC / 50 Hz / 1Ø / 0.35 KW Dimensions & Weight : 450 X 500 X 450 / 33 kgs MOC of Enclouser : ABS Plastic (with SS Skid) Ozone Mixing System Components Ozone SS-316L Recirculation Pump Flow & Pressure : 2.0-2.5 m3/hr @ 2.5-3.0 kg/cm2g Power Supply : 220-230 VAC / 50 Hz / 1 PE / 0.55 KW PTFE Ventury Injector with NRV (1 Inch) Ozone Silicon Tubing In-Built Common Control Panel for All System Components including with all type & size of pipe with fitting and electrical cable os suitable size from LT Panel to equipment required at site for smooth functiong of Ozone Generatpr is included in the quoted rate. COST OF FOUNDATIONS AS PER MANUFACTURERS RECCOMMENDED DRAWING WITH NUTS, BOLTS, ANTI VIBRATION PADS INCLUDED IN OVERALL RATES QUOTED.
Supply, erection, testing and commissioning of Ozone Generator of capacity 160 gm/hr and Oxygen Concentrator with the follwing Technical specificaaion :- (a) Ozone Generator Design Basis Ozone Requirment : 160 gm/hr Method of Ozone Injection : Recirculation Based in Tank Ozone Generator Specifications Model Proposed : OZ-AIR®ILG 160-OXY-WC Ozone Output : 160 gm/hr @ 80-100 gm/m3 Type of PSU : IGBT Based Corona Ozone generator Type of Di-electric : SS-316 L / Quartz (Water Cooled) Utilities & Requirments Power : 220-230 VAC / 50 Hz / 1Ø / 1.5 KW Cooling Water Requirment Flow & Pressure : 400-500 LPH @ 1.5-2.0 Kg/cm2g Type of Water : Potable Water (≥ 250C) (Max 200 PPM) Feed Gas Requirment Purity & Flow Rate : 20 LPM~0.6 m3/hr @ 90 % ± 2% MOC of Enclouser : SS-304L Dimensions & Weight : 1200 X 940 X 860 / 95 kgs
(b) Oxygen Concetrator Oxygen Concetrator Specifcations Model Proposed : OZ-AIR®HG-10 Oxygen Output : 10 LPM @ 93% + 2% Power : 220-230 VAC / 50 Hz / 1Ø / 0.35 KW Dimensions & Weight : 450 X 500 X 450 / 33 kgs MOC of Enclouser : ABS Plastic (with SS Skid) Ozone Mixing System Components Ozone SS-316L Recirculation Pump Flow & Pressure : 4.0-5.0 m3/hr @ 2.5-3.0 kg/cm2g Power Supply : 220-230 VAC / 50 Hz / 1 PE / 1.0 KW PTFE Ventury Injector with NRV (1 Inch) Ozone Silicon Tubing Cooling Tower For Ozone Di-electric Cooling Model Proposed : OZ-AIR® DTC-2 Draft Cooling Tower with Pump Material of Construction : FRP In-Built Common Control Panel for All System Components including with all type & size of pipe with fitting and electrical cable os suitable size from LT Panel to equipment required at site for smooth functiong of Ozone Generatpr is included in the quoted rate. NOTE : COST OF FOUNDATIONS AS PER MANUFACTURERS RECCOMMENDED DRAWING WITH NUTS, BOLTS, ANTI VIBRATION PADS INCLUDED IN OVERALL RATES QUOTED.
(a) Incoming :- MCCB 200 Amp ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge (incoming) - 01 No
(b) Outgoing :- (i) MCCB 160 Amp,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.- 02 Nos (ii) MCCB 100Amp,3 pole, 50 Hz, 415 V with rupturing capacity 25 KA - 02 Nos. (iii) Spare space for mounting MCCB along with bus bar connection - 01 No. (iv) Automatic Star Delta starter 15 HP capacity, overload relay, 415V, 3 Phase connected with motor - 01 Nos (v) Automatic Star Delta starter 40HP capacity, overload relay, 415V, 3 Phase connected with motor - 02 Nos. (vi) Change over switch 200 Amp 4 pole - 01 Nos. (vii) APFC Panel with 15 KVAR shunt capacitor, 3 Phase - 02 Nos and and 7.5 KVAR shunt capacitor, 3 phase - 02 Nos
Manning and operation of entire scheme by providing adequate manpower in two shits for AFSSR STPs and in one shift for NTS STP for the period of 11 months after completion of the work, complete all as specified and directed. Note : The operator will ensure treated water supply up to discharge point including cleaning of all sprinklers for smooth functioning.
Supply and fixing of unarmed copper cable 3 core 25 Sqmm, PVC insulated, sheathed mutistranded copper conductor, water proof suitable for pump set complete all as specified and directed.
Supply and fix route path indicator for PPR Pipe (treated water) to be fixed at a distance of every 50 mtr made of cast iron plate 1, 6mm thick, inscribed as "NOT FOR DRINKING PURPOSE" fixed with MS angle iron 25 x 25 x 4mm, 450mm long and grouted in PCC 1:2:4 up to 150mm long complete all as specified and directed by Eng-in-Charge.
RAMESH AND CO
SNG BUILDERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .