Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC | ₹7.8 Cr | L1 | Accepted-AOC Being Lowest and reasonable Tender |
| 2 | L2₹8.5 Cr+₹69.4 L (8.93%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹8.5 Cr+₹69.4 L (8.93%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹10.5 Cr+₹2.7 Cr (34.6%)Rejected-Finance NOT SPECIFIED | ₹10.5 Cr+₹2.7 Cr (34.6%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹10.5 Cr+₹2.7 Cr (34.8%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹10.5 Cr+₹2.7 Cr (34.8%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹11.6 Cr+₹3.8 Cr (49.2%)Rejected-Finance | ₹11.6 Cr+₹3.8 Cr (49.2%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹8 Cr
EMD Value
₹7.3 L
Closing Date
4 Aug 2023, 6:00 pmClosed
Chief Engineer (Navy) Mumbai
Headquarters, Chief Engineer (Navy) Mumbai 26, Assaye Building, Colaba Mumbai 400 005
CONSTRUCTION OF OFFICE CUM TRANSIT AND RESIDENTIAL ACCOMMODATION FOR OFFICE OF DEFENCE ESTATES OFFICER MUMBAI CIRCLE, COLABA, MUMBAI
2023_MES_593840_1
87920/E8
Open Tender
Civil Works
Lump-sum
540 days
Mumbai
As per tender documents
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) No 1 NW Mumbai
₹7.3 L
Yes
5 Oct 2023
9 May 2023
7 Aug 2023
9 May 2023
4 Aug 2023
21 Jul 2023
10 May 2023 - 16 May 2023
Amount
SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-'A' Part-I B/F
SCHEDULE "A" PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
SCHEDULE "A" PART-III (DEMOLITION/DISMANTLING) Total of Sch-'A' Part-III B/F
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (INTERNAL ELECTRIFICATION) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (ROADS & HARDSTANDING) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (SEWAGE DISPOSAL) Total of Sch-'A' Part-VIII B/F
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-IX B/F
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-X B/F
SCHEDULE "A" PART-XI (FIREFIGHTING) Total of Sch-'A' Part-XI B/F
SCHEDULE "A" PART-XII (LIGHTNING PROTECTION) Total of Sch-'A' Part-XII B/F
SCHEDULE "A" PART-XIII (WATER COOLER & GEYSER) Total of Sch-'A' Part-XIII B/F
SCHEDULE "A" PART-XIV (COMPOUND WALL & GATE) Total of Sch-'A' Part-XIV B/F
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS)
SITE CLEARANCE, EXCAVATION & EARTHWORK
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Note for 16.01 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
DEMOLITION/ DISMANTLING
Removing demolished debris/rubbish material (except retrieved material as specified in Sch. of Credit and disposing it outside Ministry of Defence Land. Note for 17.01 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
Dismantling curtain rod
Taking down PVC flushing cistern with all fittings
Taking down short body pillar cock of any type
Taking down short body bib tap of any type
Taking down Vitreous China wash basin of any size with all fittings complete
Taking down Wash down water closet (EWC) with all fitting
Taking down mirror
Taking down shower of any type
Taking down stop cock of any type
Taking down stainless steel towel rail
Taking down old U/S tubelight fitting of any type and capacity from walls/ceiling etc. all as directed & specified by EIC.
Taking down old u/s MCB DBs complete with MCBs, isolator etc of any type and capacity from walls/ceiling etc. all as directed & specified by EIC.
Taking down by disconnecting electric energy meter and deposited to MES store yard
Taking down by disconnecting ceiling fan from existing and deposited to MES store yard
Taking down LT panel with all accessories complete.
INTERNAL WATER SUPPLY
Supply and fix Sink cock with swinging casted round shape spout (Wall mounted module) 15mm dia, quarter turn with wall flange complete all as specified & directed.
Supply and fix over head shower 120mm round shape single flow (ABS body crome plated with grey face plate) with rubit cleaning system as specified & directed.
Supply and fix Pillar cock 15mm dia bore single lever, long neck with aerator complete all as specified & directed
S & F two way bib cock 15mm dia complete all as specified & directed
S & F Health faucet with flexible pipe (ABS body) with 01 meter long PVC tube & wall hook, complete all as specified & directed
Supply and fix wall mixer with provision for over head shower complete with 115mm long bend pipe on upper side, connecting legs & flanges all as specified & directed.
Supply and fix 25mm brass forged pressure reducing valves complete all as specified & directed.
Supply and fix 32mm brass forged pressure reducing valves complete all as specified & directed
Supply and fix 50mm brass forged Pressure reducing valves (PRV) complete all as specified & directed
Supply and fix 50mm brass forged Non return valves (NRV) complete all as specified & directed
INTERNAL ELECTRIFICATION
S & F Supply and fixing LED lights fitting 1x 10W, 2 fit, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make-HAVELLS Cat no LHEXBLP7PN1W018 or equivalent in makes mentioned in Particular Specifications
Supply and fixing LED luminaire 300 mm x 300 mm, 18 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S & F LED Bulb 9W for lamp holder. Make - HAVELLS Cat no LHLDDBEBBI8R009 or equivalent in makes mentioned in Particular Specifications
Earthing complete with galvanized steel earth plate electrode 600mm x 600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected using galvanised iron strip 32 × 6mm as earthing lead by means of bolts, nuts, check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,strip up to 7.5m, medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown all as specified and as directed. IE- 04, FF-06, Lift-04, LP-06, DG Set -4, EES-14, EWS: 4
EXTERNAL ELECTRIFICATION
Supply, installation, testing & commissioning of compact manual operating indoor type load Break Switch of capacity 400 Amps, 3 Pole, 11 KV, 50 HZ conforming to IEC 62271-1 mounted within metal clad enclosure capable of breaking normal loads & fault loads. It can be tripped by hand push button shunt trip coil or a fuse trip mechanism complete all as specified and as directed by Engineer-in-Charge..
Supply, installation,testing and commissioning Main LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting, CPRI approved,separate compartment for ACB/MCCB/metering equipments/cable gallay etc,Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Incommer (a) 400 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 250 Amp, 415V, 35 KA - 01 No. (Main incommer) (c) MCCB 3 Pole, 125 Amp, 415V, 25 KA - 02 Nos. (Bldg A (G+7) & Fire Fighting LT Panel (d) MCCB 3 Pole, 63 Amp, 415V, 10 KA - 01 No. (for G+3 Bldg) (e) MCCB TPN , 100 Amp, 415 V, 10 KA - 01 No. (For DG AMF Panel) (f) MCB TPN , 100 Amp, 415 V, 10 KA - 02 Nos. (For APFC Panel & spare) (g) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (h) Voltmeter, Digital type of suitable capacity- 01 No. (j) R-Y-B phase indicating lamp- 01 set (k) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
Supply, installation,testing and commissioning LT panel for G+7 Bldg suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved,separate compartment for ACB/MCCB/metering equipments/cable gallay etc,Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- Incommer (a) 200 A rated copper bus bar with colour coded heat shrinkable sleeve (b) MCCB 4 Pole, 125 Amp, 415V, 25 KA - 01 No. (Main incommer) (c) MCB TPN, 40 Amp, 415V, 10 KA - 02 Nos. (for 7th floor & 01 No. spare) (d) MCB SPN, 40 Amp, 240 V, 10 KA – 07 Nos. (for Ground floor to 6th floor) (e) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (h) Voltmeter, Digital type of suitable capacity- 01 No. (f) R-Y-B phase indicating lamp- 01 set (g) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPN 4 ways, 415V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed including MCBs as under: (a) MCB TPN, 63 Amp, 415V, 10 kA, C-curve – 01 No. (Main Incommer) (b) MCB SP 6-32A, 230V, 10kA, C-curve – 09 Nos (08 Nos. for qurts & 01 No. spare) Make- L&T Cat No DBTPN004DD or equivalent in makes mentioned in Particular Specifications
Supply, installation,testing and commissioning DG Utility Panel suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved,separate compartment for ACB/MCCB/metering equipments/cable gallay etc,Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- (a) 200 Amp rated copper bus bar with colour coded heat shrinkable sleeve - 01 No. (b) Auto transfer switch (ATS) of 100 Amp capacity 4 pole with adjustable time delay of Make -Havells or techno-commercial equivalent makes mientioned in PS (c ) MCCB 4 Pole, 100 Amp, 415V, 35 kA - 01 No. (Main Incommer) (d) MCCB 4 Pole, 100 Amp, 415V, 25 kA - 01 Nos. (for Lift Panel) (e) MCCB 3 Pole, 100 Amp, 415V, 25 kA - 01 No. (For Pump house panel) (f) MCB SPN 20 Amp, 230 V 10 kA - 05 No. (01 No. for security light, 01 No. for PH/ Substn bldg, 02 Nos. for both bldgs common area lighting, 01 No. spare) (g) Ammeter, Digital type, with suitable CTs of suitable capacity - 01 set (h) Voltmeter, Digital type of suitable capacity- 01 No. (j) R-Y-B phase indicating lamp- 01 set (k) Internal wiring with suitable size of PVC insulated stranded copper conductor duly crimped with copper lugs ferruled. “(l) Intelligent street light control Alpharex3 digital time switches – Astro suitable for 2 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, with combination function for creating switching programs in which the devices are switched according to astronomical time and / or fixed preset times, Daily astronomical calculation of the sunrise/sunset times based on the entered location with suitable contactor of 25A rating, 25 A SPN MCB all complete as specified and directed – 01 No (For street light control
Supply and fixing of outdoor weather proof PVC enclosure junction box of size 250x200x100mm fitted to the pole fixing with MS FI clamps size 25mm wide x 2mm thick 02Nos, suitable size nut, bolts and washers complete for terminating incoming and outgoing cables complete all as specified & directed by Engineer-in-Charge. Make:- National/Sintex .
EXTERNAL WATER SUPPLY
Cutting in position existing 300mm bore CI main insertion of tee 300 x 300 x 80mm bore for tapping out for branch connecting including fittings i.e. CI Tee, collar, tail piece, run lead joints and necessary excavation, refilling and disposal of surplus material as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of Monoblock type centrifugal pump suitable for 300 LPM water flow, upto 36 MWC head, self-priming, single-stage, centrifugal type pump having cast iron casing, enclosed type dynamically balanced phosphorous-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE-3 efficiency and conforming to IS 12615-2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring /rubber type mounding suitable for operation on 3-Phase, 415 V +/- 10%, 50 Hz AC supply complete all as specified and directed
Supply and fixing of CI foot valve flanged 80mm dia ISI mark with rubber flap complete with fange joint including jointing materials i.e. rubber gasket nuts bolts and washers etc complete all as specified and directed
SITC of factory made LT Panel (Pump House Panel) cubical type floor mounting dust and vermin proof made out of 2 mm thick CRCA sheet steel with angle iron base frame, free standing on cable duct with cable entry holes at the bottom suitable for operation on 440 Volts, AC 3 phase, 4 wire, 50Hz with 200 Amps rated copper Bus Bar, fully compartmentalised, vermin proof, painting with powder coating 7 tank process suitable for IP-52 protection including suitable PCC foundation as per manufacturer recommendation complete and comprising of the following :- (a) 200 Amp rated copper bus bar with colour coded heat shrinkable sleeve-01 No. (b) MCB 3 pole 40 Amps, 415V, 25 KA-02 No (for main pump and standby pump) (c) DOL starter suitable for pump set catered in item No. 21.02 - -02 Nos (d) Digital Voltmeter 0 to 500 Volts-1 No. (e) Digital Ammeter 0 to 200 A with CTS-1 No. (f) Phase indicating lamp LED type -set of three incoming. (g) Complete wiring of panel board with suitable size of PVC insulated copper conductor cables (h) MCB 4 pole 63 Amps, 415 V, 25 KA -1 No. (Incomer)
FIREFIGHTING
Supply and fix Gun metal branch pipe dia. 63 mm with nozzle of 20 mm dia for hose reel conforming to IS 8090. Make: Lifeguard LG Code - LG-411 or equivalent in makes mentioned in Particular Specifications
M & L for low smoke zero helogen (LSOH) flame retardant fire alarm cable 2 core , 1.5 sqmm conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V , having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber drawn through and including concelead conduit heavy duty (through the wall and ceiling) and fixed on saddles (through the vertical shaft ), earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range - 30 0 C to + 70 0 C and minimum bending radius being 6 times the overall cable diameter, RED in colour , including laying, termination and ferruling complete all as specified and directed by engineer-in charge.
GI slotted type cable trays of the following sizes using MS angle, channels, flats etc. All MS supports used shall be given one coat of red oxide primer & 2 coats of synthetic enamel paint of approved colour of size 100 x 50 mm x 2mm (for Pump House)
S & F Fire Extinguisher, Dry Chemical Powder (ABC) Type, 6 Kg capacity, as per IS:15683 with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and braket operating temperature -30°C to + 60°C. Make: Lifeguard LG Code - LG-126 or equivalent in makes mentioned in Particular Specifications
S & F Fire Extinguisher, CO2 Type, 4.5 Kg Capacity,ISI marked, confirming to IS:15683 complete with delivery hose horn, wheel type release valve, locking arrangement, pressure gauge, operation manual and braket operating temperature -30°C to + 60°C. Make: Lifeguard LG Code - LG-134 or equivalent in makes mentioned in Particular Specifications
Material and Labour for construction of valve chambers size 900 x 900 x 900mm depth with PCC foundation in the ratio 1:4:8 brick work cement mortar in the ratio 1:4 using old size of class B bricks,.PCC coping at the Top in the Ratio 1:2:4; Plastering 15mm thick in the ratio 1:4 including MS sheet cover 3mm thick with angle iron frame 25 x 25 x 4mm, locking arrangement complete with painting on steel surfaces with one coat of red oxide paint over two coats of synthetic enamalled paint including earthwork completeall as specified and and directed. FF: 02, EWS: 02
Supply, installation, testing and commissioning Fire Fighting Panel suitable for working on 3 phase, 4 wire, 415 volts, AC,50 HZ, indoor type,cubicle , floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection fabricated out of 2mm thick CRCA sheet powder coated painting , CPRI approved,separate compartment for ACB/MCCB/metering equipments/cable gallay etc,Front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing cables and connecting the outgoing MCCBs/switch gears with main bus bar by using aluminium bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cable lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mmx50mmx6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer-in-Charge comprising of following:- (a) 200 Amp rated copper bus bar with colour coded heat shrinkable sleeve - 01 No. (b) MCCB 4 pole 125 Amps, 415V, 35 KA - 01 No (Main incommer) (c) MCCB 3 pole 100 Amps, 415V, 25 KA - 02 Nos (for main pump) (d) MCB 3 pole 32 Amps, 415V, 10 KA - 01 No (for jockey pump) (e) FASD starter suitable for pump sets catered in Item No 9 & 10 of Sch-‘A’ Part-XI on Page No 53- 03 Nos (f) Digital Voltmeter 0 to 500 Volts- 1 No. (g) Digital Ammeter 0 to 200 A with CTs- 1 No. (h) Phase indicating lamp L E D type -set of three incoming. (j) Complete wiring of panel board with suitable size of PVC insulated copper conductor cables. Note - The fire fighting panel will be duly automated with logical relays and pressure switches for automatic operation of jockey pumps & main fire pumps as mandated by porovisions of NBC-2016, the cost of all items is deemed to be included and nothing extra will be paid on this account.
Supply and fix in position drain/test assembly comprised of 2 Nos 65mm dia brass tested heavy duly ball valve with screwed ends confirming to IS 554 with ISI mark (Zoloto/Leader/RB), including necessary G.I. ‘C’ class pipes, union (1 No) & site glass fitting etc complete.
TELEPHONE & LAN SOCKETS
M & L Telephone jack with pressed steel sunken box with 3 mm thick PVC top cover complete. Make :Precision Cat No. PR15 or equivalent in makes mentioned in Particular Specifications
M & L rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc for external dia 20 mm
WATER COOLER
Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA
LIFTS
Design supply, installation, testing & commissioning of 13 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 7 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 13 passenger (884kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.20 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commericial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [ixv] Flooring: 5 mm thick Alu. chequred plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 08-08 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor
Design supply, installation, testing & commissioning of 08 passenger lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 7 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. The lift shall conform to the following technical specifications. [i] Type of Lift: Passenger lift [ii] Load Capacity: 08 passenger (544kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3-Ph, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 1.43 m² [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 800 mm X 2000 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commericial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 800 mm X 2000 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [ixv] Flooring: 5 mm thick Alu. chequred plate / as per OEM design [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing
(e) Battery operated alarm bell & emergency light (rechargable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 03 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 08-08 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.
[xviii] Operation: Simplex, full collective automatic operation with and without attendant. [xix] Machine Room: Located above the hoist way, details as per building drawings [xx] Hoist way: Construction details as per building drawings [xxi] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxii] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room. [xxiii] Mirror of suitable size to be provided on complete wall opposite to main door above SS railing. [xxiv] Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
BLANK
DG SET
Supply, installation, testing and commissioning of silent DG Set, conforming to IS: 10002- 1981, complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS: 13364- 1992, mounted on a common base frame & coupled through a flexible coupling or close coupled complete with platform, control panel having meters, sound-proof canopy, etc. of capacity 62.5 KVA complete all as specified and directed. [a] Engine: 3 cylinder, in-line, 4 stroke, rated at 1500 RPM, Mechanical FIP, radiator cooled engine, heavy duty, dry type replaceable paper element air cleaner with restriction indicator, air to air aftercooling, turbocharger, pulse tuned exhaust manifold, stainless steel exhaust flexible connection,Inline fuel pump with A1 class mechanical governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, battery charging alternator with 1 x 12 V, 88 AH DC battery.
[b] Alternator: Brushless type, screen protected, revolving field, self-excited and self-regulated alternator, Class 'H' insulation limited to temperature rise of class H, Sailent pole revolving field, Single bearing, Automatic voltage regulator conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength [c] Control Panel: RAL 9003 White Powder coated control panel manufactured with 14/16 gauge CRCA sheet for weather-proof and long lasting finish. The control panel consists of the following parts: [i] Controller: Aluminum bus bars with suitable capacity with incoming/outgoing terminals [ii] Indicating lamps for ‘Load ON’ and ‘Set Running’ [iii] Instrument fuses duly wired and ferruled [iv] Copper cables of suitable capacity with incoming and outgoing terminations
[v] MCCB of suitable rating with overload and short circuit protection,100 amps 415 v tp mccb 02 nos [d] Microprocessor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP [e] Engine Metering: Oil pressure, engine temperature, starting battery voltage, engine running hours [f] AC Alternator Metering: L-L voltage and L-N voltage, current (phase and total), kVA (phase and total) and frequency [g] Engine Protection: Low lube oil pressure, high/low coolant temperature, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level [h] AC Alternator Protection: Over/under voltage, over/under frequency, loss of AC sensing. [i] Data Logging: Engine hours, control hours and upto 5 recent fault codes [j] Configurable glow plug control
[k] 12 V DC operation [l] Silencer: Critical grade silencer suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB [m] Mounting Arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. [n] Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning (h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department."
Idustrial products India
United Sales Corporation
Garima Construction Co
MC Gandhi and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .