Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAdmitted-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹27.2 L | L1 | Admitted-Finance |
| 2 | L2₹32.8 LAdmitted-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹32.8 L | L2 | Admitted-Finance |
| 3 | L3₹34.6 LAdmitted-Finance FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹34.6 L | L3 | Admitted-Finance |
| 4 | L4₹36.0 LAdmitted-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | ₹36.0 L | L4 | Admitted-Finance |
| 5 | L5₹36.4 LAdmitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹36.4 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | the bhimani group of companies L4 | R J ENTERPRISES L3 | Chakshu Enterprise L2 | Shree Ayyappa Engineering L5 | sapana enterprises L1 | cooltech engineering services L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for carrying out 'B' check for 200 KVA DG set all as per manufacturers instructions complete all as specified and directed.
Note : Cost excluding spares and Engine oil. | 1 | Each job | 3,692 ₹3,692 | 3,410 ₹3,410 | 2,950 ₹2,950 | 3,620 ₹3,620 | 3,500 ₹3,500 | 3,630 ₹3,630 |
| 2.00 | Description All as per item No 1 above but 160 KVA capacity | 2 | Each job | 3,100 ₹6,200 | 3,300 ₹6,600 | 2,860 ₹5,720 | 3,100 ₹6,200 | 3,500 ₹7,000 | 3,110 ₹6,220 |
| 3.00 | Description All as per item No 1 above but 125 KVA capacity | 1 | Each job | 3,156 ₹3,156 | 2,950 ₹2,950 | 3,000 ₹3,000 | 3,050 ₹3,050 | 3,500 ₹3,500 | 3,060 ₹3,060 |
| 4.00 | Description All as per item No 1. above but 100 KVA capacity | 2 | Each job | 2,790 ₹5,580 | 2,750 ₹5,500 | 2,750 ₹5,500 | 2,790 ₹5,580 | 3,500 ₹7,000 | 2,800 ₹5,600 |
| 5.00 | Description All as per item No 1 above but 82.5 KVA capacity | 2 | Each job | 3,250 ₹6,500 | 2,700 ₹5,400 | 2,690 ₹5,380 | 3,250 ₹6,500 | 3,500 ₹7,000 | 3,260 ₹6,520 |
| 6.00 | Description All as per item No 1 above but 75 KVA capacity | 1 | Each job | 2,980 ₹2,980 | 2,700 ₹2,700 | 2,710 ₹2,710 | 2,980 ₹2,980 | 3,300 ₹3,300 | 2,990 ₹2,990 |
| 7.00 | Description All as per item No 1 above but 50 KVA capacity | 1 | Each job | 2,500 ₹2,500 | 2,416 ₹2,416 | 2,460 ₹2,460 | 2,500 ₹2,500 | 3,300 ₹3,300 | 2,510 ₹2,510 |
| 8.00 | Description All as per item No 1 above but 7.5 KVA capacity | 2 | Each job | 1,760 ₹3,520 | 1,930 ₹3,860 | 1,800 ₹3,600 | 1,800 ₹3,600 | 3,300 ₹6,600 | 1,790 ₹3,580 |
| 9.00 | Supply only Engine oil grade 20 W 40 for incorporation against "B" check complete all as specified and directed. Make : Castrol/ Servo or equivalent. | 300 | Ltrs | 295 ₹88,500 | 235 ₹70,500 | 210 ₹63,000 | 295 ₹88,500 | 360 ₹1.1 L | 285 ₹85,500 |
| 10.00 | Supply and filling inhibitor corrosion (coolant additive concentrate) required for topping up, complete all as specified and directed.
Make : Castrol/TVS/Servo. | 60 | Ltrs | 252 ₹15,120 | 198 ₹11,880 | 200 ₹12,000 | 252 ₹15,120 | 235 ₹14,100 | 242 ₹14,520 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Mar 2026, 6:00 pmClosed
GE (NW) BHANDUP
GE (NW) BHANDUP, MUMBAI
REPAIR/ REPLACEMENT OF STREET LIGHTS, SECURITY LIGHTS, DG SETS WITH OTHER MISC CONNECTED WORKS AT NCHC POWAI AND ULHASNAGAR UNDER GE (NW) BHANDUP
2026_MES_753152_2
8481/B
Open Tender
Civil Works
NCHC POWAI AND ULHASNAGAR
AS PER TENDER DOCUMENTS.
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹70,000
Yes
3 Jun 2026
16 Mar 2026
31 Mar 2026
16 Mar 2026
30 Mar 2026
23 Mar 2026
16 Mar 2026 - 21 Mar 2026
M&L for carrying out 'B' check for 200 KVA DG set all as per manufacturers instructions complete all as specified and directed. Note : Cost excluding spares and Engine oil.
Description All as per item No 1 above but 160 KVA capacity
Description All as per item No 1 above but 125 KVA capacity
Description All as per item No 1. above but 100 KVA capacity
Description All as per item No 1 above but 82.5 KVA capacity
Description All as per item No 1 above but 75 KVA capacity
Description All as per item No 1 above but 50 KVA capacity
Description All as per item No 1 above but 7.5 KVA capacity
Supply only Engine oil grade 20 W 40 for incorporation against "B" check complete all as specified and directed. Make : Castrol/ Servo or equivalent.
Supply and filling inhibitor corrosion (coolant additive concentrate) required for topping up, complete all as specified and directed. Make : Castrol/TVS/Servo.
Supply and toping up of acid mixture suitable for lead acid batteries of 12 volts, complete all as specified and directed.
Supply only Electrolite cum distiled water suitable for lead acid battery complete all as specified and directed.
Supply only fuel filter & oil filter suitable for 200 KVA DG set capacity as per existing size complete all as specified and diretced. Make- Kirloskar/ Mahle/ C&G/ Leyland
Description All as per item No 13 above but 160 KVA capacity
Description All as per item No 13 above but 125 KVA capacity
Description All as per item No 13 above but 100 KVA capacity
Description All as per item No 13 above but 82.5 KVA capacity
Description All as per item No 13 above but 75 KVA capacity
Description All as per item No 13 above but 50 KVA capacity
Description All as per item No 13 above but 7.5 KVA capacity
Supply only of air cleaning filter inner with necessary 'O' rings for the DG sets of existing make and model of capacity of 200 KVA DG set complete all as specified and directed. Make:- Kirloskar/ Mahle/ C&G/ Leyland
Description All as per item No 21 above but 160 KVA capacity
Description All as per item No 21 above but 125 KVA capacity
Description All as per item No 21 above but 100 KVA capacity
Description All as per item No 21 above but 82.5 KVA capacity
Description All as per item No 21 above but 75 KVA capacity
Description All as per item No 21 above but 50 KVA capacity
Description All as per item No 21 above but 7.5 KVA capacity
S&F in repairs of fan belt suitable for DG set of 50 to 200 KVA capacity complete all as specified and directed. Make- FENNER/ Roflex/ Vegrip
S&F in repairs of fan belt suitable for DG set 7.5 KVA capacity complete all as specified and directed. Make:- FENNER/ Roflex/ Vegrip
Draining the fuel from existing diesel tank in a separate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position of DG set 200 KVA
Description All as per item No 31 above but 160 KVA capacity
Description All as per item No 31 above but 125 KVA capacity
Description All as per item No 31 above but 100 KVA capacity
Description All as per item No 31 above but 82.5 KVA capacity
Description All as per item No 31 above but 75 KVA capacity
Description All as per item No 31 above but 50 KVA capacity
Description All as per item No 31 above but 7.5 KVA capacity
Repairing radiator for 160 KVA DG set including dismantling from chasses and taking to the workshop for necessary welding / brazing, cleaning work etc including testing for leaks if any , steam washing the radiator and re fixing on the chasses complete all as specified and as directed.
Description All as per item No 39 above but 82.5 KVA capacity
Description All as per item No 39 above but 75 KVA capacity
S&F in replacement solenoid switch for DG set upto 200 KVA capacity complete all as specified and directed.
Supply and fix in replacement of unserviceable Maintenance free battery 150 Ah 12 volts complete all as specified and directed. Make:- Exide/ Amron or equivalent.
Supply and fix in repair unserviceable Maintenance free battery 180 Ah 12 volts complete all as specified and directed. Make:- Exide/ Amron or equivalent.
Supply and fix in replacement unserviceable battery lead copper lead of 25 Sqmm copper conductor, 2 Mtr length with brass terminal complete suitable for DG set 7.5 KVA to 160 KVA all as specified and directed. Make:- Exide/ Amron or equivalent.
Dismantling and calibrating & repairing the fuel injector assembly from authorized dealer of capacity 82.5 KVA DG set complete all as specified and directed
Description All as per item No 46 above but 100 KVA capacity
Description All as per item No 46 above but 75 KVA capacity
Taking down unserviceable battery charger and supply and fix new automatic electronic battery charger 10 Amps, 12 Volts, including making electric connections and to be housed in AMF panel complete all as specified and directed. Make : Mahamai / Span / Vinitech/ NHP.
Disconnecting of electrical connections from the unserviceable self starter of 7.5 KVA DG Set of any make/type and taking down self starter, carrying out repairs,overhauling,servicing of self starter including replacing the unserviceable parts such as bearing,carbon assembly, clutch assembly etc and other parts to make the self starter in serviceable condition, fixing back the self starter in its original position and connecting up all connections and testing complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity upto 82.5 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 82.5-200 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable water pump of DG set 50 to 200 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Supply only armature coil for self starter of DG set 50 KVA to 82.5 KVA capacity complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity 50 KVA to 82.5 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 50 KVA to 82.5 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable water pump of DG set 50 KVA to 82.5 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Supply only armature coil for self starter of DG set 100 KVA to 125 KVA capacity complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity 100 KVA to 125 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 100 KVA to 125 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable water pump of DG set 100 KVA to 125 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Supply only armature coil for self starter of DG set 160 KVA to 200 KVA capacity complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity 160 KVA to 200 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 160 KVA to 200 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable water pump of DG set 160 KVA to 200 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Supply and fix in repair power contactor MN 45, 45 Amps, 415 Volts,50 Hz, complete all as specified and directed.
Supply and fix in repair DC Contactor MNO 40,complete all as specified and directed.
Supply and fix in repairs Line Voltage Meter (LVM) unit suitabe for 7.5 KVA to 50 KVA all as apecified and directed.
Supply and fix in repairs Digital Engine Controller Display Unit for 7.5 to 50 KVA DG Set
Supply only Digital type electronic auto mains failure controller (AMF) with inbuilt programmer and necessary control wiring, complete all as specified and directed. Make:- L&T/ Siemens/ Procom
Supply and fix in replacement digital type Frequency meter, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in replacement digital type volt meter, complete all as specified and directed. Make:- L&T/ AE /IMP
Supply and fix in replacement digital Ampere meter with CTs, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in replacement power contactor MN 45, 45 Amps,415 Volts,50 Hz, complete all as specified and directed.
Supply and fix in replacement DC Contactor MNO 40, complete all as specified and directed.
Supply and fix in replacement Line Voltage Meter (LVM) unit suitabe for 62.5 KVA to 100 KVA complete all as apecified and directed.
Supply and fix in replacement Digital Engine Controller Display Unit for 62.5 to 100 KVA DG Set
Supply only Digital type electronic auto mains failure controller (AMF)with inbuilt programmer and necessary control wiring, complete all as specified and directed. Make:- L&T/ Siemens/ Procom
Supply and fix in replacement digital type Frequency meter, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in replacement digital type volt meter, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in repair digital Ampere meter with CTs, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in replacement power contactor MN 45, 45 Amps,415 Volts,50 Hz, complete all as specified and directed.
Supply and fix in replacement DC Contactor MNO 40,complete all as specified and directed.
Supply and fix in replacement Line Voltage Meter (LVM) unit suitabe for 125 KVA to 200 KVA all as apecified and directed.
Supply and fix in replacement Digital Engine Controller Display Unit for 125 to 200 KVA DG Set
Supply only Digital type electronic auto mains failure controller (AMF)with inbuilt programmer and necessary control wiring, complete all as specified and directed. Make:- L&T/ Siemens/ Procom
Supply and fix in replacement digital type Frequency meter, complete all as specified and directed. Make:- L&T/ AE/ IMP
Supply and fix in replacement digital type volt meter, complete all as specified and directed. Make :- L&T/ AE / IMP
Supply and fix in replacement digital Ampere meter with CTs, complete all as specified and directed. Make:- L&T/ AE/ IMP
M & L spray painting of silencer of upto 20 KVA DG Set capacity with two coat of black/silver synthetic enamel paint over a coat of red oxide primer after cleaning, scrubbing and filling cavities complete all as specified and directed
M & L spray painting of silencer of 50 KVA to 82.5 KVA DG Set capacity with two coat of black/silver synthetic enamel paint over a coat of red oxide primer after cleaning, scrubbing and filling cavities complete all as specified and directed
M & L spray painting of silencer of 100 KVA to 150 KVA DG Set capacity with two coat of black/silver synthetic enamel paint over a coat of red oxide primer after cleaning ,scrubbing and filling cavities complete all as specified and directed
M & L spray painting of silencer of 160 KVA to 200 KVA DG Set capacity with two coat of black/silver synthetic enamel paint over a coat of red oxide primer after cleaning ,scrubbing and filling cavities complete all as specified and directed
Supply and fixing in repair of LED street light fitting new generation energy saving and environment friendly long life LED 60 Watt with following specifications: 230 V AC outdoor type,top opening , IK-08, seperate driver compartment, input voltage AC 140V-270V, power factor > 0.95, beam angle 140 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , Pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 120 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and 6 kV surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with manufacture warrenty complete all as specified and as directed by engineer-in-charge.
Supply and fixing in replacement of LED street light fitting new generation energy saving and environment friendly long life LED 70 Watt with following specifications: 230 V AC outdoor type,top opening , IK-10, seperate driver compartment, input voltage AC 140V-270V, power factor > 0.95, beam angle 180 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , Pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 145 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and 6 kV surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with manufacture warrenty complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting new generation energy saving and environment friendly long life LED 90 Watt with following specifications: 230 V AC outdoor type,top opening , IK-10, seperate driver compartment, input voltage AC 140V-270V, power factor > 0.95, beam angle 180 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , Pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 145 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and 6 kV surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with manufacture warrenty complete all as specified and as directed.
Supply and fixing in replacement of LED flood light fitting new generation energy saving and environment friendly long life LED 210 Watt with following specifications: 230 V AC outdoor type,top opening , IK-10, seperate driver compartment, input voltage AC 140V-270V, power factor > 0.95, beam angle 180 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , Pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 150 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and 6 kV surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with manufacture warrenty complete all as specified and as directed by engineer-in-charge.
Supply and fixing in replacement of LED secuirty light fitting new generation energy saving and environment friendly long life LED 35 Watt with following specifications: 230 V AC outdoor type,top opening , IK-08, seperate driver compartment, input voltage AC 140V-270V, power factor > 0.95, beam angle 140 x 90 degree , colour temperature 6500 K , rated life 50,000 Hours , Pressure die cast aluminum hosing and heat resistant with tempered PC cover with integrated lens, efficiency 120 lumen/watt ,BIS Certified to LM-79/LM-80 lamp with impact and corrosion resistant including thermal management , over-voltage,short circuit ,open circuit and 4 kV surge protection in multiple optics complete with IP 66 protection including bracket of suitable size with manufacture warrenty complete all as specified and as directed.
Supply and drawing through conduit pipe on pole/ wall for making connection to the light fittings 3 Core, Copper cable,PVC insulated and sheathed heavy duty 1100 volt grade multi stranded copper conductor (FRLS) cable 1.5 Sqmm complete all specified and directed.
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 155 x 155 x100 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for Three phase and neutral (Four terminals) for cable in cable out entire complete. Terminal box to be fixed to wall/ Pole complete all as specified and directed. Make : Sintex/national
Taking out existing unserviceable FRP terminal box and S&F mounting type weather proof terminal box of size 250 x 250 x105 mm heavy duty (machine mould) consisting of 01 No MCB SP 06 Amps and backlite connector of 32 A for Three phase and neutral (Four terminals) for cable in cable out entire complete. Terminal box to be fixed to Pole complete all as specified and directed. Make : Sintex/ National
Supply and fix in repairs pipe bracket made out of 40 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Supply and fix in repairs pipe bracket made out of 25 mm dia GI pipe, medium grade, upto 1.5 mtr long, bent to shape and fixed on existing pole/ wall including necessary clamp/saddle and fixing by screw/bolt complete all as specified and directed.
Taking down unserviceable LT cable complete all as specified and directed
Supply and laying in replacement cable XLPE insulated, armored heavy duty electric cable, galvanized steel strip or wire armored, with aluminum conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm x 2 core. complete all as specified and directed.
Supply and laying in replacement cable XLPE insulated, armored heavy duty electric cable, galvanized steel strip or wire armored, with aluminum conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminum conductor of size 10 sqmm x 4 core complete all as specified and directed.
Supply and laying in replacement cable XLPE insulated, armoured heavy duty electric cable, galvanised steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm x 4 core complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed.
Supplying and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches for cable protection complete all as specified and directed.
M&L in repairs of GI pipe 80 mm dia light grade with all fittings for cable protection including taking down old GI pipes and fittings complete all as specified and directed.
M&L in repairs of GI pipe 50 mm dia light grade with all fittings for cable protection including taking down old GI pipes and fittings complete all as specified and directed.
M&L for Preparation of old exposed surface of LT steel tubular poles of any type / size with bracktes clamps etc and spray painting with one coat of aluminium paint upto 6 mtr long and exposed surface of pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole no's with paint all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation filling & mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping / fountation of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified and directed.
Supply and fixing in repairs analog timer switch 3P module, 24 Hrs preprogram complete all as specified and directed
M&L for LT straight through joint heat shrinkable kit suitable for 3 ½ / 4 core of size 10 to 16 sqmm underground cable all as specified and directed.
Description all as per item no.124 above but 25 to 50 sqmm
Description all as per item no.124 above but 70 to 120 sqmm
Description all as per item no.124 above but 150 to 185 sqmm
Taking out unserviceable LT cable of size 25 sqmm to 185 sqmm complete all as specified and directed
Supply and laying cable XLPE insulated, armoured heavy duty electric cable, galvanized steel strip or wire armoured, with aluminium conductor electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm x 3.5 core
Description all as per item no.129 above but 35 sqmm, 3.5 core
Description all as per item no.129 above but 50 sqmm, 3.5 core
Description all as per item no.129 above but 95 sqmm, 3.5 core
Description all as per item no.129 above but 120 sqmm, 3.5 core
Description all as per item no.129 above but 150 sqmm, 3.5 core
Description all as per item no.129 above but 185 sqmm, 3.5 core
Supply and fix including taking down old unserviceable MCCB of MCCB 125 Amps 4 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix including taking down old unserviceable MCCB of MCCB 100 Amps 4 Pole, with breaking capacity 16 KA, as per site requirement and complete all as specified and directed.
Supply and fix including taking down old unserviceable MCCB of MCCB 160 Amps 4 Pole, with breaking capacity 25 KA, as per site requirement and complete all as specified and directed.
Supply and fix including taking down old unserviceable MCCB of MCCB 200 Amps 4 Pole, with breaking capacity 25 KA, as per site requirement and complete all as specified and directed.
Supply and fix including taking down old unserviceable MCCB of MCCB 250 Amps 4 Pole, with breaking capacity 36 KA, as per site requirement and complete all as specified and directed.
Supply and fix including taking down old unserviceable MCCB of MCCB 100 Amps 3 Pole, abjustable type, 50Hz with breaking capacity 16 KA, as per site requirement with sheet metal enclosure and complete all as specified and directed.
M & L for painting of epoxy with hardner paint for DG Set preparation oil painted surface by scratching and apply epoxy paint with compressed air gun machine and complete all as specified and directed
M & L for painting of epoxy with hardner paint for LT panel board other MS steel surface, preparation oil painted surface by scratching and apply epoxy paint with compressed air gun machine and complete all as specified and directed
Surface dressing n. exc 15 Cm of surrounding area of power house, LT panel and any out door installation in soft/ loose soil (including bush Cutting)complete all as specified and directed
M & L Structural steel, rolled section such as joist, beam, channel, angle, Tee, in available lengths for structural farm of panel complete all as specified and directed
M&L for finding faults of LT UG XLPE cable of any size and any length upto 240 Sqmm by using computerized / primary current injection method / any other method as directed by the Engr-in-charge and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint including exaction, refilling and testing after jointing all as required and directed for cable upto 70 sqmm. Note: Joints shall be paid for separately.
Description all as per item no.146 above but 70 to 120 sqmm
Description all as per item no.146 above but 150 to 185 sqmm
M&L for Earthing complete with galvanized steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanized earth lead strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed
M&L for DG Set shifting from NCHC ulhasnagar to NCHC Powai of capacity 7.5 KVA duly inclusive of removing of all connections carefully and lifting it from base and carefully placing it behind administrative office at NCHC Powai including making of PCC foundation with 1:3:6 PCC and making rain shed for DG sed with all MS bars, nut bolts and Galvanised sheet as per required for 4 mtr x 2.5 mtr shed and 2 mtr x 3 mtr PCC plinth and making the connection of DG set to main MCCB incomer of Admin office. Note: All necessary repairs and earthing not written in this item will be paid saparetly, PCC plinth and rain shed rates are covered in this item.
Supplying fixing of manual operated Changover switch with rain proof PVC enclosure of capacity 125 KVA , 4 pole, 25 kA complete all including making drilled holes and fixing to wall complete all as specified.
Supplying fixing of manual operated Changover switch with rain froof PVC enclosure of capacity 250 A, 4 pole, 25 kA complete all including making drilled holes and fixing to wall complete all as specified.
Supplying fixing of automatic and manual operated Changover switch with rain froof PVC enclosure of capacity 400 A , 4 pole , 35 kA complete all including making drilled holes and fixing to wall complete all as specified.
Supply install and testing of Automatic Main Failure (AMF) panel suitable for 50 KVA DG Set , out door, floor mounted/pedestal tyuupe cubical, self supported,CPRI approved make front and rear openable, double door hinged type with locking arrangement and slopping top canopy ventilations on both sides with wire mesh, IP-52 protection with dust and vermin proof etc.fabricated out of 3.15 mm CRCA sheet duly powder coated with 7 tank chemical process,mounted/fixed on and including MS angle iron stand of 1.0 mtr height (50 cm above FFL and 50 cm below FFL) ,fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation,control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size/capacity of copper strips for switch gear connection from main bus bar,earth bus strip of 32x6 mm size for entire length of panel ,suitable size of MS gland with gland plate and alluminium lugs/thimbles for all incoming/out going cables including 02 Nos earthing as per SSR Earth plate No 3 with MS earthplate etc.complete all as directed by GE including and accommodating the followings:- (i) 4 Pole, 415 Volts rating, rupturing capacity 25 KA thermal magnetic release, fixed over load and short circuit protection -02 (1 No each for commercial & DG supply) (ii) AMF control circuit with HRC back up fuses complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications of M/s Powerica/Goel Power Engineears/KALA GENSET incorporating engine start ,stop,three attempt starting facility and failure to start etc.
Multicore sensing cable 2.5 sqmm x 8 core PVC XLPE armoured copper cable for DG set to AMF auto sensing of main power faliure complete with end termination all directed by engineer-in-charge.
Supply and fixing LED Post top 30 Watt Elegant and conical aesthetic pleasing design with powder coated finish using high heat conductivity material which increases heat dissipation speed IP-65/66 ingress protection , cool/warm white with <10% THD and lumen efficiency 90 lm/watt CRI> 70 complete including installation on suitable size of MS pipe included all as per specified and as directed.
Supply and fixing of garden cone Bollard lights 10 watt , die cast aluminium housing ,opel diffuser with in-built LED, operating temperature -10 to 50 degree, power factor .0.9, CRI>80Ra , 50,000 hrs lifespan surface mounted complete all as per directed by Engineer-in-charge.
Supply and fixing of Cable copper XLPE Armoured, 1100 V, conforming to IS : 7098 Pt-I 1988 , size 6 sqmm 2 core in trenches all as specified and direcetd.
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL. Preffered. Make-Legrand Cat No. 0104 DLP Series . Honeywell VP18 Series . NIEDAX -HKL1022.1 Series all as per following:
PLASTIC TRUNKING 195X50MM
FLEXIBLE COVER 180MM WIDTH
END CAPS
FLAT ANGLE FOR 195X50-DLP TRU
INTERNAL ANGLES-ADJ FRM 80 DEG
EXTERNAL ANGLES-ADJ FRM 60 DEG
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL. Preffered. Make-Legrand Cat No. 0104 DLP Series . Honeywell VP18 Series . NIEDAX -HKL1022.1 Series all as per following:
PLASTIC TRUNKING 105MMX50MM
FLEXIBLE COVER 85MM WIDTH
DLP END CAP 150X50
FLAT ANGLES
INTERNAL ANGLES-ADJ FRM 80 DEG
EXTERNAL ANGLES-ADJ FRM 60 DEG
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL. Preffered. Make-Legrand Cat No. 0104 DLP Series . Honeywell VP18 Series . NIEDAX -HKL1022.1 Series all as per following:
PLASTIC TRUNKING 105MMX50MM
FLEXIBLE COVER 85MM WIDTH
DLP END CAP 150X50
FLAT ANGLES
INTERNAL ANGLES-ADJ FRM 80 DEG
EXTERNAL ANGLES-ADJ FRM 60 DEG
Supply of PVC DLP - On wall trunking with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation.Trunking should confirm to the current specifications of NF C 68-104 in terms of both performance and level of functions provided by the system. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. Trunking should be delivered in length of 2m. The trunking covers and partitions should be in PVC white RAL 9003.The accessories should be in plastic ABS white RAL. Preffered. Make-Legrand Cat No. 0104 DLP Series . Honeywell VP18 Series . NIEDAX -HKL1022.1 Series all as per folollowing:
PLASTIC TRUNKING 80MMX50MM
FLEXIBLE COVER 65MM WIDTH
END CAP
FLAT ANGLES
INTERNAL ANGLES-ADJ FRM 80 DEG
EXTERNAL ANGLES-ADJ FRM 60 DEG
Supply and fixing LED Solar security light fitting 35 Watt with 12 V lithium ferro phosphate (LFP) battery, IP66 ingress protection, Pressure die cast aliminium, pole top or side entry mounted 6500 K cool white complete including installation on pole or on wall all as specified and direcetd.
Removal of existing submain wiring of upto Submain 6sqmm three phase and keep it in safe custody for refing after fixing of cable tray and inclusing placing the submain wiring in new flexible pipe complete.
Labour only for attending of energency DG set Breakdown complaints with trained DG set mechanic for faults and rectifying them complete all as specified and directed.
Supply and fixing of DG set acquastic insulation foam complete including removal of old insulation from DG set and completely sealing of DG set to prevent the entry of rodents inside DG set with complete with all required material all as specified and directed by engineer-in-charge.
Supply and fixing in repair DG set door and hinges by taking out old broken door hinges and fixing of new door hinges complete.
M&L for filling of fine sand filling in open electrical ducts and FOL room complete all as specified and directed by enginer-in-charge.
M&L for fixing of new LT connectors including removal od old burnt porcelin/PVC connectors complete all as specified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 53,546.00 (Minus) as listed in Schedule of Credit. Note (for item 1 to 170): Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height G+4 to G+16 configuration , Necessary scaffolding and safety measures required during execution of work are including in this items. Note 3:- Any T&P required at site will be arranged by contractor without any finantial effect to department and rates for the same are included in respective items. Note 4 : Contractor supervisor to report on daily basis to the concerned JE as detailed by the Engr-in-Charge on daily basis to collect the complaints from complaint cell/ JE in morning by 9.15 am on working days, supervise the work and again report to AGE/JE in evening by 4.45 pm to submit the progress and details. In case of absence of supervisor penalty will be imposed for 500 per day. Note 5: While Quoting the tender contractor must keep in mind that the fitting and fixtures will be fixed as per day to day complaint recieved from various locations i.e NCHC Powai, Ulhasnagar and 23 A Mahada Powai and the contractor must engage the adequate labour to resolve complaints within 24 hrs time frame (except holidays and rainy days) after reciving of complaint without any extra cost to govt or as directed by engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
TENDERDOCUMENTS_8481.pdf
Tender Documents • 1.35 MB
BOQ_847445.xls
BOQ • 1.12 MB
Download all tender documents and submit your bid