Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.4 LAccepted-Finance E TYPE SHOPPING CENTRE SARNI DISTT BETUL M P 460447 | BETUL | MADHYA PRADESH | 460447 | ₹91.4 L | L1 | Accepted-Finance L1 |
| 2 | L2₹1.1 Cr+₹17.1 L (18.7%)Accepted-Finance MANJEET TRADERS WARD NO 18 SHASTRI NAGAR BURHAR ROAD SHAHDOL MP 484001 | SHAHDOL | SHAHDOL | MADHYA PRADESH | 484001 | ₹1.1 Cr+₹17.1 L (18.7%) | L2 | Accepted-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Due to nonsubmission of documents to confirm PQR clause (I), turnover certificate against PQR clause (IV) and Affidavit against PQR clause(V) and Annexure IX is also not submitted on stamp paper.order copy enclosed is not of same/similar type |
| 4 | Rejected-Technical | - | - | Rejected-Technical Submitted performance certificate confirms successful operation less than 6 months. Order copies enclosed is not of sufficient value to fulfil PQR Clause(III) and turnover ( for PQR clause IV) of the firm is less than desired average annual turnover |
| Sl No | Description | Qty | Unit | MANJEET TRADERS L2 | S.S. ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Air circuit breaker( rating 800A/1000A) required for retrofitting in existing module (rating 90KW, 110KW,132KW & 150KW ) of Unit 1 & 2
Specification given in Annexure-I of tender schedule for retrofitting of Draw out ACB in existing module. Technical Specification of Major items should be ISI standard. | 26 | Nos | 2,18,000 ₹67,55,122.4 | 2,03,248.3 ₹62,35,658 Lowest |
| 2.00 | Motor Protection Numerical relay
(Specification given in Annexure-I) | 26 | Nos | 55,000 ₹17,04,274 Lowest | 66,714.7 ₹20,46,806.84 |
| 3.00 | Retrofitting Charges of air circuit breaker in existing module including retrofit kit.
(As detailed scope of work given in tender schedule) | 26 | Nos | 78,000 ₹23,93,040 | 28,000 ₹8,59,040 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2 L
Closing Date
10 Aug 2026, 3:30 pmClosed
SE Purchase dongalia
SE Purchase dongalia
Module Modification (Module rating 90 KW, 110 KW, 132 KW, 150 KW) by retrofitting of Air Circuit Breaker at 2x600 MW, SSTPP, Dongalia
2026_MPPGC_515989_1
PT-3819
Open Tender
Miscellaneous Goods
Item Rate
90 days
Dongalia
Please refer Tender documents.
18 documents required · 18 mandatory
₹5,000
Yes
₹2 L
Yes
7 Sept 2026
7 Jul 2026
12 Aug 2026
7 Jul 2026
10 Aug 2026
7 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Air circuit breaker( rating 800A/1000A) required for retrofitting in existing module (rating 90KW, 110KW,132KW & 150KW ) of Unit 1 & 2
Specification given in Annexure-I of tender schedule for retrofitting of Draw out ACB in existing module. Technical Specification of Major items should be ISI standard. | 26 | Nos | - | - |
| 2 | Motor Protection Numerical relay
(Specification given in Annexure-I) | 26 | Nos | - | - |
| 3 | Retrofitting Charges of air circuit breaker in existing module including retrofit kit.
(As detailed scope of work given in tender schedule) | 26 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.50 MB
detailedNIT3819.pdf
Tender Documents • 0.49 MB
tend3819.pdf
Tender Documents • 0.40 MB
NEWSBD.pdf
Tender Documents • 19.14 MB
nit3819.pdf
Tender Documents • 0.67 MB
BOQ_626326.xls
BOQ • 0.27 MB
Technicalbidfinal.xls
Additional Documents • 0.36 MB
ModelCertificate.pdf
Additional Documents • 0.17 MB
checklistannexureopennew.pdf
Additional Documents • 1.45 MB
3742.pdf
PDF • 0.63 MB
3652.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .