| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹34.9 L+₹3.3 L (10.3%)Rejected-AOC | L2 | Rejected-AOC Not being lowest bidder | |
| 3 | L3₹35.6 L+₹3.9 L (12.3%)Rejected-AOC | L3 | Rejected-AOC Not being lowest bidder | |
| 4 | L4₹38.5 L+₹6.9 L (21.7%)Rejected-AOC | L4 | Rejected-AOC Not being lowest bidder | |
| 5 | L5₹40.3 L+₹8.6 L (27.3%)Rejected-AOC | L5 | Rejected-AOC Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹89,000
Closing Date
10 Jun 2021, 6:00 pmClosed
GE I R nd D West Bengaluru
GARRISON ENGINEER I R nd D WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
MAINTENANCE, REPAIRS TO HT 11 KV PANELS, TRANSFORMERS, HT VCB/OCBs, LT DISTRIBUTION SYSTEM, EARTHING AT PHASE-I AND FAR FLUNG AREA OF GE (I) R AND D (WEST) BENGALURU
2021_MES_438840_1
GE(I) R ND D (WEST)/BAN/09 OF 2021-22 8879E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Bengaluru
Refer NIT
8 documents required · 8 mandatory
₹500
GE I R nd D West Bengaluru
₹89,000
Yes
27 Jul 2021
5 May 2021
16 Jun 2021
6 May 2021
10 Jun 2021
28 May 2021
6 May 2021 - 27 May 2021
Amount
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard / dense soil all as directed.
Returning and filling in, soils, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Taking down existing 11 KV grade cable Supply and laying New XLPE insulated, screened, bedded galvanized steel strip / wire armoured heavy duty with aluminum conductor, of cross sectional area 185 sq mm 3 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed.
Taking down existing 11 KV grade cable, Supply and laying New XLPE insulated, screened, bedded galvanized steel strip / wire armoured heavy duty with aluminum conductor, of cross sectional area 95 Sq mm, 3 core with cable protection works (as applicable) laid in trenches/ ducts/ fixed on pole/ wall/ laid under road/ path/ culvert/ drains/ encased in pipe, jointing and testing complete all as specified and as directed.
Taking down existing 1100 Volts grade cable and laying only new XLPE insulated cable, screened, bedded galvanized steel strip/wire armoured heavy duty with aluminium conductor of cross sectional area 185 Sq mm 3.5 core with cable protection works (as applicable) laid in trenches/ducts/fixed on pole/wall/laid under road /path/culvert/drains/encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed. Notes for Sl Item Nos 6 to 12 :- Cables will be issued under Schedule 'B' free for laying only.
All as per Serial Item No 6, here-in-above, but 3.5 Core 150 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary lugs, jointing and testing complete all as specified and as directed.
All as per Serial Item No 6, here-in-above, but 3.5 Core 95 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary and testing complete all as specified and as directed.
All as per Serial Item No 6, here-in-above, but 3.5 Core 70 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary and testing complete all as specified and as directed.
All as per Serial Item No 6, here-in-above, but 3.5 Core 50 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary and testing complete all as specified and as directed.
All as per Serial Item No 6, here-in-above, but 3.5 Core 35 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary and testing complete all as specified and as directed.
All as per Serial Item No 6, here-in-above, but 4 core / 3.5 Core 10 Sq mm with cable protection works (as applicable) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary and testing complete all as specified and as directed.
Disconnecting the GOD of any capacity and make from main power supply after taking proper shut down and carrying out repairing of unserviceable GOD by taking down, dismantling & removing dust, carbon deposits or any other substance and replacing worn out parts of fixed contacts-03 Nos, moving contacts-03 Nos, reassembling complete GOD, re installing in position after applying petroleum jelly on moving and fixed contacts complete all as specified and as directed.
Taking down unserviceable air brake switch, Supply and fix, new switch, air brake, gang operated 11 KV, HT Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete all as specified and as directed.
Taking down old drop out fuse and supply and fixing Drop out fuse with fuse links and wire fuse complete of capacity HT 11 KV 200 Amps 10(KA) station class complete with fixing clamps, bolts, nuts and washers fixed in repairs complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing Lightning arrester Expulsion type of capacity HT 11 KV 65 (KA) station class complete with fixing clamps, bolts, nuts and washers fixed in repairs complete all as specified and as directed by Engineer-in-charge.
Dismantling, Repairing and rewinding of transformer capacity 160/200 KVA after disconnecting all electric connections and removing from position, transporting to work shop and carrying out the following works complete all as specified and as directed. (a) HV and LV of copper winding (b) Testing and commissioning ,Varnishing of HV,LV Winding , filling fresh transformer oil to the capacity as required, cleaning and Painting of Transformer after completion of all job fixing to the bed connecting to the existing power line etc., complete
Servicing and Painting of two/four pole structure ,OCB, Transformer, and panel board and old steel joists mild steel channels & supports with one coat of aluminium paint and colour paint as per the existing colour of the equipments including colour code for RYB to indicate the colour code for body earthing & lighting arrestor complete including taking proper shut down & greasing the GOD switch & tightening of all bolts & nuts and replacement of ACSR conductor and PVC sleeves , worn-out lugs, PG clamps and HT fuses in the structure as required at site including two coats of white wash for masonry plat form complete and one coat of synthetic enamel paint for weld mesh, removing of Weeds / Plants inside the yard and Cleaning and painting of Chain link fence for transformer area complete all as specified and as directed.
Supplying and spreading 20 mm graded stone aggregate inside the fencing area of transformer all as directed .
Supplying and spreading 40 mm graded stone aggregate inside the fencing area of transformer all as directed .
Material and labour for laying of un-reinforced precast concrete cable cover, class HV, type 1 flat size 300mm x 180mm x 40mm (ISI marked) all as directed and specified
Material and labour for laying of reinforced precast concrete cable cover, class HV, type 1 flat size 300mm x 180mm x 40mm (ISI marked) all as directed and specified
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
Material and labour for laying of burnt bricks sub class `B’ bricks of size 230 x 115 x 75 mm, laid in trenches for cable protection all as directed and specified
Taking out old unserviceable joints including Supplying, jointing new outdoor termination heat shrinkable new jointing Kit suitable for 11 KV, XLPE cable of size 3 core 185 Sq mm, testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new indoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 185 Sq mm, testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new outdoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 95 Sq mm , testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new indoor termination, heat shrink type joint, suitable for 11 KV (earthed) grade XLPE armoured aluminium conductor cable of size 3 core 95 Sq mm, testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new Straight through cable jointing kit suitable for 11 KV, HT UG XLPE cable of size 3 core 185 Sq mm, testing, complete all as specified and as directed
Taking out old unserviceable joints, Supplying, jointing new Straight through cable jointing kit suitable for 1100 V, LT UG XLPE cable of size 3.5 core 50 to 185 Sq mm, testing, complete all as specified and as directed
Supply and fix, Aluminium lugs suitable for cable of size 70 to 240 Sq mm complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 40 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 50 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Taking down unserviceable cable protection pipe, Supply and Fixing on walls / pole with clamps / laid in trenches, 100 mm bore Galvanized iron tubing, light grade, as cable protection, complete all as specified and as directed.
Material and labour, Galvanized earth strip of size 25 x 4 mm earth continuity or main earthing lead fixed to Wall/ trenches /ducts through Galvanized iron pipe including necessary clamps, nuts, bolts, etc., and connecting up complete all as specified and as directed.
Supply and fix in repairs, CT ratio coil 600/5 Amps of 230 volt (Set of 3) complete all as specified and as directed.
Supply and fix in repairs, CT ratio coil 400/5 Amps of 230 volt (Set of 3) complete all as specified and as directed.
Supply and fix in repairs, Neon indicator lamps RYB 3 phase (set of 03) complete all as specified and as directed.
Calibration of IDMTL relays comprising to over current and earth fault at HT systems through primary and secondary injection method and testing complete of control relays panels installed with HT OCB/VCB's panels and all as directed
Repairing of potential transformer (PT) 11 KV/110 V withdraw able type with automatic shutters by disconnecting PT from main power supply of OCB/VCB panel, separating fixed and moving chambers opening of covers, cleaning, meggering the windings etc & commissioning after replacement of following unserviceable spare parts complete all as specified and as directed. NOTE :- i) Spare parts, Components will be measured and paid separately under relevant items of this schedule'. ii) Components / accessories to be replaced shall be inspected and approved by Engineer-in-Charge, iii) Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed.
Supply only HT PT fuse of capacity 11 KV - 3 Amps all as specified and as directed.
Supply only fixed Contacts of VCBs, all as specified and as directed.
Supply only moving contacts of VCBs all as specified and as directed.
Supply and fix, Transformer breather assembly with silica gel filled including removing the unserviceable breather unit of 500 gram capacity complete all as specified and as directed.
Supply and fix, Transformer breather assembly with silica gel filled including removing the unserviceable breather unit of 1000 gram capacity complete all as specified and as directed.
Repair to power distribution transformer of capacity between 200 KVA to 1500 KVA to stop oil leakage by draining out transformer oil complete in moisture proof drum, dismantling top cover along with conservator tank, Marshaling box, breather etc and replacing gasket, washers, oil seals etc and reassembling transformer, refilling oil after filtration by high vacuum oil filtration plant & testing complete all as directed.
Supply only ISI Marked transformer oil in sealed drum and topping up of transformer oil in transformers and HT OCB's after filtration with 50 to 60 KV/min of die-electric strength of oil by high vacuum oil filtration plant complete all as specified and as directed.
Disconnecting the power distribution transformers and HT OCB's of any capacity from main power supply and carrying out oil filtration through high vacuum oil filtration plant, extracting the moisture content, dust, sludge and carbon deposits from oil and bringing to 40 KV/min die electric strength through 2.5 mm gap of testing electrode including carrying out acidity and di-electric strength test before and after oil filtration and submission of test certificate complete all as specified and as directed.
Supply and fix, HT brass spindles with porcelain bush of power distribution transformer of capacity 315 KVA to 500 KVA including taking out unserviceable spindle complete all as specified and as directed.
Supply and fill dehydrating breather with first fill dehydrating agent (silica gel) supply and fix Dehydrating agent (silica gel) of power distribution transformers including taking out unserviceable Silica gel complete all as specified and as directed.
Detection /localization of fault in HT 11 KV UG cable of any size and length, by means of cable fault locator including pinpointing the exact location of fault ,retrieving the exposing damaged portion carefully for further inspection and repairs complete all as specified and as directed . NOTES :- (i) Charges for cable fault equipment carried out by BESCOM/ other agencies are deemed to be included in the item rate quoted (ii) Contractor on demand by the department has to arrange the above equipment without any delay failing which necessary penalty will be levied by the department.
Supply and fix, MCCB, 4 pole, 415 volts, 400 amps, 36 kA breaking capacity including taking out old unserviceable MCCB complete all as specified and as directed.
Supply and fix, MCCB, 4 pole, 415 volts, 250 amps, 36 kA breaking capacity including taking out old unserviceable MCCB complete all as specified and as directed.
Supply and fix, MCCB 4 pole, 415 volts, 200 Amps, 36 KA breaking capacity including taking out old unserviceable MCCB all as specified and as directed..
Supply and fix, MCCB 4 pole, 415 volts, 160 Amps, 36 KA breaking capacity including taking out old unserviceable MCCB all as specified and as directed..
Supply and fix, MCCB 4 pole, 415 volts, 25 to 100 Amps, 16 KA breaking capacity including taking out old unserviceable MCCB all as specified and as directed..
Servicing and repairing of LT Air Circuit Breaker by drawing out ACB mechanically from cabinet, cleaning entire parts, greasing, oiling, tightening of nuts/bolts and replacing unserviceable spare parts and reassembling the same, complete all as specified and as directed. Note : Spare parts of following items shall deemed to be included in quoted rate :- i) Under voltage release coil 230 V - 1 No ii) Shunt release Coil 230 V - 1 No, iii) Closing Coil 230 V - 1 No
Material and labour for plain cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate as in coping to poles, panels, etc., including necessary formwork, complete all as specified and as directed.
Disconnecting the HT Vacuum circuit breaker (VCB) of any capacity and take from main power supply, carrying out servicing of HT VCB's 400/630 Amps capacity by drawing out the VCB trolley from the HT panel, opening the top cover of oil tank, drain out the oil in moisture proof drum, cleaning of entire parts of switch gear such as fixed and breaking mechanism with emery paper, cotton waste etc., checking for proper alignment for smooth movement of fixed and moving contacts after applying petroleum jelly, tightening of screw, bolts, nuts etc, filling of the tank with oil after filtration and checking of all internal wiring, re-assembling the VCB in position, connecting VCB with main power supply and testing to the satisfaction of Engineer-in-charge. Note:-Shut down available on user permissions.
B5BUILDING SOLUTIONS
Pacific Enterprises
H S S ENGINEERS AND CONTRACTORS
kamadhenu Electricals
Solar Electricals and Electronics
GS TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .