Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹9.2 L+₹49,656.58 (5.71%)Rejected-Finance 194A LUKER GANJ ALLAHABAD UP | ALLAHABAD | ALLAHABAD | UP | 211001 | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹10.0 L+₹1.3 L (14.9%)Rejected-Finance 25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹10.0 L+₹1.3 L (15.3%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹14.0 L+₹5.3 L (60.5%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-Finance In order but L5 |
| Sl No | Description | Qty | Unit | A.V. ASSOCIATES L3 | Manish Enterprises L2 | KUKREJA BROTHERS L4 | SIYA ASSOCIATES L1 | yameen enterprises L6 | PARADISE INFRA POWER COMPANY L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in CM 1:3 and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as directed by Engineer - in- Charge. | 415 | Per Point | 6 ₹2,490 | 5 ₹2,075 | 5 ₹2,075 | 4.11 ₹1,705.65 Lowest | 10 ₹4,150 | 30 ₹12,450 |
| 2.00 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. (Rate for cutting chasis of walls all are included in the quated rate) | - | - | - | - | - | - | - | - |
| 2.10 | One light point or one fan point or bell point controlled by one switch or bell push | 100 | Per Point | 230 ₹23,000 | 220 ₹22,000 Lowest | 280 ₹28,000 | 221 ₹22,100 | 350 ₹35,000 | 330 ₹33,000 |
| 2.20 | One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch | 45 | Per Point | 230 ₹10,350 | 220 ₹9,900 Lowest | 280 ₹12,600 | 221 ₹9,945 | 350 ₹15,750 | 330 ₹14,850 |
| 2.30 | One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch | 30 | Per Point | 125 ₹3,750 | 120 ₹3,600 | 100 ₹3,000 | 81 ₹2,430 Lowest | 125 ₹3,750 | 100 ₹3,000 |
| 3.00 | All as per serial item No 2 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed | 40 | Per Point | 300 ₹12,000 | 320 ₹12,800 | 360 ₹14,400 | 241 ₹9,640 Lowest | 450 ₹18,000 | 380 ₹15,200 |
| 4.00 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in Existing PVC concealed Conduit Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. | - | - | - | - | - | - | - | - |
| 4.10 | One light point or one fan point or bell point controlled by one switch or bell push | 120 | Per Point | 190 ₹22,800 | 200 ₹24,000 | 180 ₹21,600 | 171 ₹20,520 Lowest | 350 ₹42,000 | 330 ₹39,600 |
| 4.20 | One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one, one way 05/06 Amps switch | 30 | Per Point | 210 ₹6,300 | 200 ₹6,000 | 180 ₹5,400 | 171 ₹5,130 Lowest | 350 ₹10,500 | 330 ₹9,900 |
| 4.30 | One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch | 30 | Per Point | 125 ₹3,750 | 120 ₹3,600 | 100 ₹3,000 | 81 ₹2,430 Lowest | 125 ₹3,750 | 100 ₹3,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
5 Jun 2025, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
REPAIR /MAINT AND ATTEND DAY TO DAY INTERNAL ELECTRIFICATION COMPLAINT OF LEKHANAGAR UNDER AGE E/M (ES) AT GE(U) MEERUT CANTT
2025_MES_707040_1
8681/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE (U) Meerut Cantt
₹50,000
Yes
12 Sept 2025
8 May 2025
12 Jun 2025
8 May 2025
5 Jun 2025
22 May 2025
Amount
Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in CM 1:3 and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as directed by Engineer - in- Charge.
Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings. (Rate for cutting chasis of walls all are included in the quated rate)
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 2 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable in Existing PVC concealed Conduit Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one, one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 4 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
Supply & fixing switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed .
Supply & fixing of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed .
Supply & fixing bell, AC, 230 volts, single pole, ding dong type size compete all as specified & directed.
Supply & fixing switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed .
Supply & fixing socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing ceiling fan regulator, electronic, type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed.
Supply & fixing lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed
Supply & fixing of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed.
S&F 20 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F 10 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 2' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
Supply & fixing in repair/replacement switch piano flush type, 05/06 Amps single pole , one way 240 volts complete all as specified & directed .
Supply & fixing in repair/replacement of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed .
Supply & fixing in repair/replacement bell, AC, 230 volts, single pole, ding dong type size compete all as specified & directed.
Supply & fixing in repair/replacement switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed .
Supply & fixing in repair/replacement socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing in repair/replacement of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing in repair/replacement ceiling fan regulator, electronic, type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed.
Supply & fixing in repair/replacement lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed
Supply & fixing in repair/replacement of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed.
S&F in repair/replacement 20 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F in repair/replacement 10 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 2' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S & F in repair/ replacement Recess mounted economical LED panel light 2`X2` 36 watt with high quality diffuser for uniform light with 100lm/w housing of pressed aluminium sheeet with complete all as specified and directed.
S&F in repair/ replacement LED Bulk Head Fitting 10 Watt housing made up corrosion resistant unbreakable PC with high quality diffuser for glare free Aesthetically designed gaskit IP65 protection, efficacy 95lm/watt complete all as specified and directed.
Supply and fix in repair LED post top for gate light 45 Watt with spun aluminium housing and pressure die-cast spigot. Clear polycarbonate diffuser for uniform bright light, efficacy 95lm/watt, with IP66 degree of protection & impact resistance complete all as specified and directed.
Demolition and removing from site old PCC and Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge. (for foundation of post top and bollard).
S&F PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs as in repair complete all as specified and as directed by the Engr-in-Charge.
M & L for sub main wiring with 1.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
M & L for sub main wiring with 2.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
M & L for sub main wiring with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing complete all as specified & directed including taking out old u/s sub main wiring any size.
Supplying and fixing in replacement 10 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, two twin core cable flat or circular complete all as specified and directed.
Supplying and fixing in replacement 6 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, two twin core cable flat or circular complete all as specified and directed.
Supply & fixing in repair/replacement MCB , SP, AC, 240 volts of 05 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing in repair/replacement MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply & fixing in repair/replacement MCB, SPN, AC, 240 volts of 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed
Supply & fixing in repair/replacement MCB, TPN, 415 volts of 100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed
Supply & fixing in repair/replacement MCB DB Box 8 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity.
Supply & fixing in repair/replacement MCB DB Box 4 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity.
Supply & fixing in repair/replacement Sheet Metal Enclosures TPN, 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity.
Supply & fixing in repair/replacement Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB TPN as incomer with necessary internal wiring, MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed including taking out old u/s DBs any capacity.
S&F in repair/replacement MCCB 4Pole 415 V fixed type, 63/100 Amps with breaking capacity 16 KA complete al as specified and directed
Supply & fixing Sheet Metal Enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections complete all as specified & directed including taking out old u/s any capacity.
Supply and fix in repair metal clad socket 20 Amp 2P+E, 230 volt AC complete all as specified and directed
Supply and fix in repair metal clad plug 20 Amp 2P+E, 230 volt AC complete all as specified and directed
S & F in repair casing caping 25 mm complete all as specified
S & F in repair casing caping 15 mm complete all as specified
S & F in repair flexible conduit 25 mm complete all as specified
S & F in repair flexible conduit 32 mm complete all as specified
S&F in repair Hylum sheet 3 mm thick of 9"x5" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
S&F in repair Hylum sheet 3 mm thick 9"x7" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
S & F in repair for LED Bulb 12 watt 240 volt complete all as specified and directed.
Supply & Fix in replacement LED Emergency LED linear Lamp, Wattage 12W, Voltage /frequency 220-240V/ 50-60Hz, Cool Day light, PF > 0.9 CCT 6500K, upto 4 Hrs Back up all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I.
Supplying, fixing in replacement LED Security light including connecting and testing of energy saving & environment friendly, made out of pressure die cast anodised aluminium with toughened glass cover housing, 30 watts LED to achieve electrical safety class 1, Pf >0.95, lumens >110 lm/W, Ingress protection not less than IP65, including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed.
Taking down of existing unserviceable wall fans and S&F wall mounting fan 400 mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified.
Taking down of existing unserviceable ceiling fans and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete alll as specified and directed.
Taking down existing unserviceable ceiling fan of 1200mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified.
Taking down existing unserviceable exhaust fan of 450mm/380mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan, cleaning and testing the fan for its rpm and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified.
Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, check nuts, pin etc. and re-assembling and refixing in position, connecting and testing complete all as specified.
Taking down of existing unserviceable exhaust fan plastic body 250mm and S&F exhaust fan plastic body 250mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified.
Renewal of cylinder capacitor 2.5 MFD with earthing terminal for ceiling fan / cabin fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene, SH (self healing), of the following capacities complete all as specified.
Renewal of cylinder capacitor 4 MFD with earthing terminal for Exhaust fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene, SH (self healing), complete all as specified.
Supply & Fix in repair ceiling fan down rod of MS pipe 15mm bore of length as per site measurement including cutting/threading making tide for fixing providing check nuts wachers etc complete.
S & F in repair ceiling fan blade white colour 1200 mm sweep with and including nut bolts for fixing suitable for Usha, Polar, Orient complete all as specified and directed.
S & F in repair PVC insulated 23/0.0076 flexible cord twin core with stranded copper conductor as specified and directed
Renewal of ball bearing of any size for celing fans/ wall bracket fan, cabin fans, table fan etc (bearing number 6201,6202,6203 as required). all as specified and directed.
Taking out unserviceable bush from ceiling fan and making arrangement for ball bearing by lathing at workshop complete all as specified and directed.
Renewal of Gunmetal bush bearing of suitable for exhaust fan etc. of any size complete all as specified and directed.
Renewal of mild steel hanging clamps suitable for any sweep of fans including necessary nuts, bolt and washers and split pin complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty LT power cables with aluminium conductor, 1100 volts grade cross sectional area 10 sqmm 2 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty LT power cables with aluminium conductor, 1100 volts grade cross sectional area 16 sqmm 4 core including lux of cable complete all as specified and directed.
Dismantalling of existing cable and Supply, laying and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty LT power cables with aluminium conductor, 1100 volts grade cross sectional area 25 sqmm 4 core including lux of cable complete all as specified and directed.
Exacavation in trenches in soft/ loose soil not exceeding 1.5 m wide and not exceeding 1.5m deep and getting out for laying of underground cables complete all as specified.
Returning filling in ( soil) including spreading , levelling ,watering and well ramming in layers not exceeding 25cm thick all as specified and directed .
Removing exacavated materials (soil) to a distance not exceeding 50m away from the starting point and dipositing where directed at a level not exceeding 1.5m above all as specified and directed by Engr-In-Charge.
Sand cushioning for underground cables 8 cm before laying the cable and 15 cm after laying and streatching the cable, complete all as specified. (Note: Punned thickness shall be measured).
Material and labour for brick protection with sub class B bricks using old size bricks , laid dry, flat over cable , longer length of brick laid perpandicular to the cable in trenches all as directed.
Attending the complaints of non functional ceiling /exhaust fan of any sweep and testing and repairing the ceiling /exhaust fan without taking down by checking/replacing of fan condenser ,fan regulators hanging accessaries and connection of wires etc.,and making fan serviceable all as directed. Note: (a) items such as fan condenser,fan regulator ,flexible cable multi stranded 2 core shall be measured and paid separately . (b) Reapiring up to two fans at a time in one quarter will be consider as one complaint and more than two fans at a time , two complaints / visit shall be considrered for same quartrer
Attending the complaints for checking of existing electrical fittings and fixtures in qtrs at sectors area for continuous electric supply including carrying out minor repairs etc as required to make the items functional and replacing tube rods, chokes, CFLs, copper cable , switches, sockets, holders etc as per suitable size and capacity at site complete all as specified. (Note - (a) items such as switches, sockets,holders, ceiling roses, tube light fitting, CFL fitting, ceiling light fitting , mirror light fitting, bulk head gitting etc shall be measured and paid under respective items of schedule. (b) Repairing up to four points at a time in one quarter will be measured as one complaint .
Manish Enterprises (BID ID -3314159)
A.V. ASSOCIATES (BID ID -3306751)
KUKREJA BROTHERS (BID ID -3313702)
PARADISE INFRA POWER COMPANY (BID ID -3303538)
yameen enterprises (BID ID -3307253)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .