Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.2 L+₹6,085.50 (0.30%)Rejected-Finance | L2 | Rejected-Finance not found lowest | |
| 3 | L3₹20.7 L+₹57,581.50 (2.86%)Rejected-Finance | L3 | Rejected-Finance not found lowest | |
| 4 | L4₹21.3 L+₹1.2 L (5.78%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L4 | Rejected-Finance not found lowest | |
| 5 | L5₹21.6 L+₹1.5 L (7.24%)Rejected-Finance HOUSE NO 172 A CANAL ROAD SUJANPUR TEH DISTT PATHANKOT 145001 PUNJAB | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance not found lowest |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
1 Mar 2025, 6:00 pmClosed
Maj Nitin Bisht
GE Basoli PO Lakhanpur Distt Kathua (JK) 184152
GE/BAS-61/2024-25 Special repair to building No NP-57, np-59 and NP-60 at Madhopur under GE Basoli
2025_MES_696280_1
GE/BAS-61/2024-25
Open Tender
Civil Works
Item Rate
120 days
Madhopur Stn under GE Basoli
As per tender docs
8 documents required · 8 mandatory
₹500
GE Basoli
₹55,000
Yes
25 Mar 2025
3 Feb 2025
3 Mar 2025
3 Feb 2025
1 Mar 2025
19 Feb 2025
Amount
Excavation in trenches n exc 1.5 m wide and nexc 1.5 m in depth for foundation of pole/stay and laying of UG cable/GI pipe and getting out in any type of soil complete all as specified and directed.
M&L returning, filling and including spreading, levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5mtr above the starting point , complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkat with shutter (Without taking of shutter from frame) area exceed 1.50 Sqm but not exceed 4.00 Sqm each complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid,bedded and pointed in any mortar complete all as specified and directed.
Dismantling of ceiling asbestos cement board any thickness including cover fillites complete all as specified and directed.
S&F Pressed steel frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike mate etc complete of size 125x60mm, including two coats of synthetic enamel paint over a coat of red oxide primer Complete all as specified and directed
M&L for providing cement concrete 1:3:6 type C-0 using 12.50mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed.
S&F 35mm thick IInd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.20 (a) of SSR Part-I 1991 (Larger size to be provided) complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified and directed.
S&F 3 mm thick figured glass glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 200 mm long complete all as specified and directed.
S&F aluminium handle, cast type, anodised ,150 mm size. complete all as specified and directed
S&F aluminium alloy , anodised ,sliding door with hasp and size 250mm long with hasp, staples and fixing clips of sheet extruded section and fixing bolts of extruded section complete all as specified and directed.
S&F For MS 300mm ordinary rat tail rod pattern springs including roller and roller plate.complete all as specified and directed.
S&F Harrision rails 20mm dia of stainless steel with and including stainless steel brackets, Stops, rollers etc. complete all as specified and directed.
M&L for preparation of treated/un-treated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise describe applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Material & Labour for Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube, factory made with double side shutter wire gauged shutter & glass glazed shutter (wire cloth and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down cement plastering on stone wall/brick wall etc including racking out of joints hacking for key scrubbing down with water etc complete all as specified and directed
M & L Rendering 15mm thick in cement mortar 1:4 and finished even and smooth without using extra cement and preparation of new plastred surfaces and applying two coats of cement base paint on walls over a coat of primer complete all as specified and directed.
M & L Rendering 10mm thick in cement mortar 1:6 and finished even and smooth without using extra cement and preparation of new plastered surfaces and applying two coats of distemper oil emulsion over a coat of 1mm thick wall putty complete all as specified and directed.
Material and labour for plain cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates using FE 410-W (Gde-E-250) Quality A complete all as specified and directed .
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed
Dismantling of AC (Corrugated or semi corrugated etc) sheets in roof covering including ridges complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including complete all as specified and directed .
M&L for Machine cut kota slab fooring 18 to 20 mm thickness over cement screed base laid and jointed with gray cement slurry mixed with pigment to matche the shade of the slab including rubbing and polishing and 20mm thick screed bed or bedding layer of mortar in cm 1:6 for laying floor finishes complete all as specified and directed.
M&L Kota stone slab 16-18 mm thick as in riser of steps, skirting, dado and pillar laid over cement screed and jointed with gray cement slurry mixed with pigment to matche the shade of the slab including rubbing and polishing, and Rendering 10 mm thick in CM 1:4 as for backing coat of wall tiles complete all as specified and directed
S&F in position suspended false ceiling system using E-grid suspended ceiling grid system of M/S Saint Gobain. The size of grid shall be 600x600mm with GI frame work main runner 38x24mm cross tee 25x24mm and wall angle 24mmx24mm using 8mm thick ceiling panel laminated wth PVC film on front face and foil back available in due drop texture as per IS- 2095 Part-I 1996 fixed in the grid of E grid suspended ceiling Grid system duly suspended by 4mm dig GI bar hangers from the purlins of the roof with butter fly clips complete all as specified and directed .
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L hard core of gauge n.exc. 63 mm, deposited, spred and leveled in layers n.exc 15 cm thick, watered and rammed to a true surface with broken stone or boulders complete all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed
All as per item No above but except brick complete all as specified and directed
M&L 75 mm thick PCC, type C-2, 1:3:6, (using 20mm graded crushed stone aggregate) as in sub base of floor. complete all as specified and directed.
M&L coloured chequered cement conrete tiles 30cm x 30cm x 25mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor 15mm thick cement screed bed or bedding layer in CM 1:4 complete all as specified and directed
M&L 75 mm thick PCC, type C-2, 1:3:6, (using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core including takingout existing complete all as specified and directed.
Supply and fix for DWC high density polythylene pipes having dia 63/50 as per site requirement having corrugation on the wall and plain surface on the wall conforming to IS : 14930 (Part-I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fitting as required complete all as specified and directed.
Taking down copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as per specified and directed.
M&L for point wiring one light point/fan point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) in and including PVC concealed conduit having thickness 1.8mm with all fittings, pressed sunken box thickness of sheet not less than 2mm thick suitable for modular switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping as required and making good disturbed surface area and white wash/colour was to matching with the existing colour complete all as per specified and directed. Note (a) Insulation test of point wiring (b) colour coding is to be maintained. (Ph-Red, N-Black, Half-Yellow, Earth-Green) (Make of 1.5 sqmm copper wire: Grandaly, L&T and plaza PVC conduit . Make: Finolex/Palaza/Bajaj/Kamplast). (b) Rate for cutting chases for conduit and flushing metal boxes including making good the disturbed wall deemed included in quoted rates. (c) Modular switches, sockets, cover plates and all connected, accessories shall be paid separately in respective items.
All as per item No 46 above but for one 3 pin 5 amps socket outlet on the same board with other switchs complete all as per specified and directed.
All as per item No 46 above but for one 3 pin 5 amps socket outlet on independent board with other switchs complete all as per specified and directed.
M&L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) in and including PVC concealed conduit having thickness 1.8mm with all fittings, pressed sunken box thickness of sheet not less than 2mm thick suitable for modular switches and sockets for 5 pin 15 amps socket outlet, including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor (FRLS) as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping as required and making good disturbed surface area and white wash/colour was to matching with the existing colour complete all as per specified and directed. Note (a) Insulation test of point wiring (b) colour coding is to be maintained. (Ph-Red, N-Black, Half-Yellow, Earth-Green) (Make of 2.5 sqmm copper wire: Grandaly, L&T and plaza PVC conduit . Make: Finolex/Palaza/Bajaj/Kamplast). (b) Rate for cutting chases for conduit and flushing metal boxes including making good the disturbed wall deemed included in quoted rates. (c) Modular switches, sockets, cover plates and all connected, accessories shall be paid separately in respective items.
S&F in repair/replacement Modular switch one way 6A,1 Module, complete all as specified and directed .
S&F in repair/replacement Modular socket 6/10A-2/3 pin 2 Module complete all as specified and directed.
S&F in repair/replacement Modular switch one way 16A,1 Module complete all as specified and directed
Supplying & Fixing modular socket out let, 6 pin, 6/16 Amps, multipurpose 2 in 1, 2 module 230 volts, complete all as specified and directed.
Supplying & Fixing modular fan regulator electronic modular type stepped (rotary type) 2 module with 5 steps speed control complete all as per specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with bakelite back plate having matching colour to holder suitable for angle/batten fittings complete all as per specified and directed.
S&F ceiling rose surface bake lite two to three terminal isolated body fixed on PVC round block complete all as per specified and directed.
S&F modular white cover plate with frame 8 modular complete all as specifed and directed.
S&F modular white cover plate with frame 6 modular complete all as specifed and directed.
S&F modular white cover plate with frame 4 modular complete all as specifed and directed.
S&F modular white cover plate with frame 3 modular complete all as specifed and directed.
S&F modular white cover plate with frame 1 modular complete all as specifed and directed.
S&F in replacement LED tube light fitting 20Watt, 230Volt, 6000K, including LED 4 Feet batten type fitting fixtures complete with all accessories, internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as per specified and directed.
Supply & fix fans ceiling complete with BLDC regulator and remote control copper wiring and accessories 230 V,1200 mm sweep. BEE 5 star rated, BLDC type fixed on roof and connected to ceiling rose complete all as specified and directed.
Supplying and Fixing LED bulb of capacity 9 watts, 6000K complete with all accessories base (ISI marked) all as specified & directed.
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) 8 way fitted with copper bus bar rated 200 Amp (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link, earth bar complete all as per specified and directed.
S&F MCB SPN 40 Amps with 10KA breaking capacity of 'B' series in distribution board complete all as per specified and directed.
S&F MCB SP 6-32 Amps with 10KA breaking capacity of 'B' series in distribution board complete all as per specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 03 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. (Note: The rate quoted include cost of min 7.5 metre earthling wire.)
M&L for LED security lights luminaries, energy efficient of capacity 20 watts LED, 5700K, inbuilt surge protection device having IP-66 driver potted type completed fitted on bldg with bracakets made out of 32mm dia GI pipe medium grade 1.5 in length long with suitable size of 02 Nos MS flat clamps FI 25x3mm including nuts, bolts including connecting up with PVC copper conductor wire 1.5 Sqmm single core from security light to ceiling rose etc complete all as specified and as directed. Note: (i) Contractor shall produce LM 79 & LM 80 test report form OEM owned NABL accredited laboratory, (ii) Contractor shall give guarntee of complete fitting/ fixtures form minimum of 2 years from the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of fittings/fixtures at no extra cost, (iv) Contractor shall arrange complete material at site for approval of GE before incorporation in the work.
Ms Narinder Kumar Sehgal (BID ID -3249013)
M/S YOGESHWAR ASSOCIATES GOVT CONTRACTOR (BID ID -3250170)
R K Builders (BID ID -3247218)
M/S SATYA SAI CONSTRUCTION (BID ID -3249592)
M/s GIrdhari Lal Rakesh Kumar (BID ID -3250046)
M/S SURINDER KUMAR MAHAJAN (BID ID -3252864)
G.M. ENGINEERING SERVICES (BID ID -3249566)
Shiva Builders (BID ID -3252004)
HARI OM ENTERPRISES (BID ID -3252700)
AMNEET PAUL SINGH (BID ID -3251972)
M/S OM SAI RAM BUILDERS (BID ID -3249789)
Substantial Const. Co. (BID ID -3249763)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .