Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹15.2 L+₹43,877 (2.97%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹16.6 L+₹1.9 L (12.6%)Rejected-Finance 6 KAMMAVAR STREET MITTANAMALLEE IAF AVADI TIRUVALLUR TAMIL NADU 600055 | THIRUVALLUR | TAMIL NADU | 600055 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹17.0 L+₹2.2 L (14.9%)Rejected-Finance NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹18.9 L+₹4.1 L (27.6%)Rejected-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
27 Feb 2021, 6:00 pmClosed
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87630E8 SPL RPRS TO HT OH CONDUCTOR INTO HT UG CABLE OD AVADI UNDER GE AVADI, CHENNAI.
2021_MES_414520_1
87630E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE AVADI CHENNAI
₹44,000
Yes
1 Apr 2021
20 Jan 2021
1 Mar 2021
20 Jan 2021
27 Feb 2021
6 Feb 2021
20 Jan 2021 - 27 Jan 2021
Amount
REVISED BOQ UPLOADED ON 02 FEB 2021, BOQ UPLOADED ON 20 JAN 2021 CANCELLED.
SCH "A" PART-I (EXTERNAL ELECTRIFICATION)
Dismantling old unserviceable ACSR conductor of assorted sizes as in over head lines from poles and taken on credit complete all as specified and as directed.
The weight of ACSR conductor only shall be measured as per preamble given in Sl Page No.384 of SSR Part-II 2010.
Dismantling cross-arms of mild steel channel or angle sections etc., complete and taken on credit complete all as specified and as directed.
The porcelain insulators shall also be dismantled alongwith the conductors and taken on credit.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Common burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade,(earthed), 3 core, cross sectional area 95 sqmm in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(c) Precommissioning test shall be carried out at factory premises before despatch.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under roads / crossings etc., of bore of pipe 150mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls / poles etc., of bore of pipe 40mm for cable protection complete all as specified and as directed.
Cable route indicator dully marked with HT or LT cable, working voltage, size of cable and route made out of GI plate 3mm thick, 150mm dia fixed on angle iron ISA 25mm x 25mm x 3mm, 500mm long, suitably embedded in PCC 1:2:4, type B1 using 20mm graded stone aggregate of size 300mm x 300mm x 300mm on ground and the mild steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Cutting existing bituminous road surfaces to a depth not more than 150mm, and making good the surface with PCC 1:3:6, type C1, using 20mm graded stone aggregate to match to the adjacent surface after laying pipes / cable including removal of debris to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
The plan area of the road surface cut for laying pipes shall be measured for purpose of payment.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .