Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.6 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical Not Responsive | |
| 3 | Rejected-Technical ACHNAMBAL ZAFFRON COLONY PANTHACHOWK SRINAGAR J K INDIA 191101 | SRINAGAR | JAMMU AND KASHMIR | 191101 | - | Rejected-Technical Not Responsive | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Responsive | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Responsive |
| Sl No | Description | Qty | Unit | Barraq Enterprises L1 |
|---|---|---|---|---|
| 1.00Supply Items | ||||
| 1.00 | Providing, Installation and Commissioning of DC operated Contact Multiplying Relay with base having 2NO 2NC for making available potential free contacts for input to Smart Meters for capturing
(a) Circuit Breaker Status (Breaker ON & Breaker OFF) &
(b) Relay status (Over Current & Earth Fault)
Bidder shall quote the price on a Per CMR Basis | 4,680 | No | 1,224.08 ₹57,28,694.4 Lowest |
| 1.00 | Providing, Installation and Commissioning of AC operated Contact Multiplying Relay with base having 2NO 2NC for making available potential free contacts for input to Smart Meters for capturing
Circuit Breaker Status (Breaker ON & Breaker OFF)
Bidder shall quote the price on a Per CMR Basis | 200 | No | 1,013.33 ₹2,02,666 Lowest |
| 1.00 | Replacement of damaged breaker Auxiliary Switchs, indication lamps, cables wherever necessary for restoring Breaker Status Indication (ON / OFF indication) on C&R Panels for making available inputs to the Smart Meters
Bidder shall quote the price on a Per Switch Basis | 125 | No | 4,026.42 ₹5,03,302.5 Lowest |
| 1.00 | Relocating of Services (Installed 4 No CMRs/Auxillary Switches etc) from Old Panels to new ones including cost of wire, lugs, Ferrules,TBs etc
(Item to be executed only in case of change of C&R Panels in a substation post installation of CMRs etc.)
Bidder shall quote the price on a Per Panel Basis | 150 | No | 2,501.67 ₹3,75,250.5 Lowest |
| 1.00 | Supply of 30V / 36V DC operated Contact Multiplying Relays having 2 NO 2 NC alongwith base as Spares.
Bidder shall quote the price on a Per CMR Basis | 200 | No | 383.96 ₹76,792 Lowest |
| 1.01 | Annual Maintenance / On Field support for maintenance of the installed equipment to ensure availability of captured Signals (Circuit Breaker ON, OFF & Relay O/C and E/F Status)
Bidder shall quote the price on a Per Year Basis | 3 | Year | 1,58,349.24 ₹4,75,047.72 Lowest |
| 2.00NOTE: 1. Item 3 of BoQ above will be executed in the event of damaged circuit breaker auxiliary switch resulting in non availability of ON OFF indication on the feeder panel. 2. Item 4 of BoQ above will be executed in the event of change of feeder panels post execution and commissioning of CMRs as defined in items 1 and 2 above. | ||||
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
3 Sept 2024, 2:00 pmClosed
CEO, ITC Division, KPDCL
Office of the CEO, ITC Division PDD Complex Bemina
Retrofitting of 11kV Control and Relay Panels in 33/11kv substations of KPDCL to enable capturing of Circuit Breaker ON OFF and Over Current and Earth Fault Relay Status by way of SITC of Contact Multiplying Relays
2024_PDD_253696_1
CEO/ITC/06 of 2024 Dated 19/07/2024
Open Tender
Electrical and Maintenance Works
Turn-key
180 days
Kashmir
As Per SBD
6 documents required · 6 mandatory
₹3,000
Yes
CEO, ITC Division, KPDCL
₹2.0 L
Yes
Office of CEO, ITC Division, KPDCL
14 Oct 2024
20 Jul 2024
5 Sept 2024
20 Jul 2024
3 Sept 2024
25 Jul 2024
20 Jul 2024 - 24 Jul 2024
25 Jul 2024
Amount
Supply Items
Providing, Installation and Commissioning of DC operated Contact Multiplying Relay with base having 2NO 2NC for making available potential free contacts for input to Smart Meters for capturing (a) Circuit Breaker Status (Breaker ON & Breaker OFF) & (b) Relay status (Over Current & Earth Fault) Bidder shall quote the price on a Per CMR Basis
Providing, Installation and Commissioning of AC operated Contact Multiplying Relay with base having 2NO 2NC for making available potential free contacts for input to Smart Meters for capturing Circuit Breaker Status (Breaker ON & Breaker OFF) Bidder shall quote the price on a Per CMR Basis
Replacement of damaged breaker Auxiliary Switchs, indication lamps, cables wherever necessary for restoring Breaker Status Indication (ON / OFF indication) on C&R Panels for making available inputs to the Smart Meters Bidder shall quote the price on a Per Switch Basis
Relocating of Services (Installed 4 No CMRs/Auxillary Switches etc) from Old Panels to new ones including cost of wire, lugs, Ferrules,TBs etc (Item to be executed only in case of change of C&R Panels in a substation post installation of CMRs etc.) Bidder shall quote the price on a Per Panel Basis
Supply of 30V / 36V DC operated Contact Multiplying Relays having 2 NO 2 NC alongwith base as Spares. Bidder shall quote the price on a Per CMR Basis
Annual Maintenance / On Field support for maintenance of the installed equipment to ensure availability of captured Signals (Circuit Breaker ON, OFF & Relay O/C and E/F Status) Bidder shall quote the price on a Per Year Basis
NOTE: 1. Item 3 of BoQ above will be executed in the event of damaged circuit breaker auxiliary switch resulting in non availability of ON OFF indication on the feeder panel. 2. Item 4 of BoQ above will be executed in the event of change of feeder panels post execution and commissioning of CMRs as defined in items 1 and 2 above.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.57 MB
BOQ_737807.xls
BOQ • 0.31 MB
SBD.pdf
Tender Documents • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .