| 1 | L1₹28.5 LAccepted-AOC RAILWAY ROAD 9 10 KC MARKET 132001 2021R66 | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC LOA issued | |
| 2 | L2₹30.9 L+₹2.4 L (8.43%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹31.0 L+₹2.5 L (8.70%)Rejected-Finance H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.3 L+₹2.8 L (9.85%)Rejected-Finance MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L4 | Rejected-Finance L4 | |
| 5 | L5₹31.3 L+₹2.8 L (9.95%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L5 | Rejected-Finance L5 |
Tender Value
₹28.8 L
EMD Value
₹57,500
Closing Date
25 Sept 2023, 5:00 pmClosed
Amit Goyal
ED-Karnal
Providing 200 KVA Electrical Sub Station and 125 KVA DG set in CHC Bapoli Distt. Panipat. Recall
2023_HRY_300926_2
2023629E9B36 6508 41C0 853D 70A6D78B96C3665BAR
Open Tender
Electrical Works
Works
90 days
Panipat
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹57,500
Yes
4 Jan 2024
25 Aug 2023
26 Sept 2023
28 Aug 2023
25 Sept 2023
28 Aug 2023
Amount
[20.89.7]`Designing, Supply and erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 plus (-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel, making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer, outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge. The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 metres. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT`s) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k)Copper bus bar of suitable size l) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running, load on, Dc control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge` 7. 125 KVA
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP
[23.22.2.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.3. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB above 250 A and up to 630 A FP
[23.22.8.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.5. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 400 amp 415 volts
[23.24.3.11]MS STAND, BUS BAR CHAMBER AND PANELS 3.11. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 400 amp 4 bars of 100 cm each (cross section 63 mm x6 mm) chamber over all size 1.10 m x 55 cm x 23 cm
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame.
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.10.1]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 1. Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Metre. underground cable excluding the cost of cable/pipe complete in all respect.
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.3]HT CABLE 4.3. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :240 to 400 sqmm
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
[24.7.4]RCC FOUNDATIONS FOR DG SET 4. 125 KVA DG Set
[24.7]RCC FOUNDATIONS FOR DG SET "Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)" Unit: per cum
Pdg. And Fixing of wire mesh jali around the transfarmer of size 4` x 8` made out of 75 x 25 x 3.25 mm jali fixed with angel iron frame made out of M.S. Angel 50 x 50 x 6 mm.
Supply and erection of stay set with stay wire suitable for 9M long PCC pole made out of 7/3 SWG GI wire with U type M.S. Rod 5/8` dia duly threaded by means of angle iron of size 50 x 50 x 6 mm x 30 cm 6 feet long M.S. Rod buried in ground after fixing with cross channel size 75 x 40 x 6 mm x 60 cm long the stay wire will be binded on the top of the pole with help of suitable size of double U type M.S. Clamps and stay fixed with nuts and bolts the stay wire shall be insulated in the middle point with the help of egg insulator including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work.
Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. (Make and specification as per UHBVNL/UHBVNL) including Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc as required
Supply and Erection of rubber mat of size 1Mx2 M X 12mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In- charge of the work.
Supply and Erection of fire buckets of 9 Ltr. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire` as per fire protection necessary sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \ satisfaction of the Engineer m charge of the work
Supply and erection of ACSR conductor (ISI Marked) with accessories including stringing and sagging of conductor of various sizes as well as jointing and binding with insulator at support complete in all respect up to entire satisfaction of Engineer-in-charge of the work. ACSR Cond. 50 Sqmm (Make and specification as per UHBVNL/UHBVNL).`
Supply, stringing and sagging of GSL wire 8 SWG complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS channel 100x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS angle 50x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS flat 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Providing and fixing of Nut and Bolt of size as per ISI specification of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of 11KV GI Pin insulator with Pin Rashtriya / Jayshree / BHEL make with pin with all labor and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing `H`pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL.
Supply Erection Testing and Commissioning of 11kV indoor HT metering panel indoor / outdoor complete with C.Ts P.Ts Cubical .as per requirement / approved by UHBVNL consisting of the following. - Cubical panel free standing floor mounting type made out of sheet steel 16 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the UHBVNL. - 3 Nos. 11KV CTS of rating as approved by UHBVNL for indoor installation of approved make of UHBVNL. - 1 Nos. 11KVPTS 11000/10 VA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of UHBVNL. ` `The cubical panel will be completed in all respect including inter connection, internal wiring with PVC copper cable, modem and allied accessries its testing and approval of all item by UHBVNL cost of all testing/ approval charges or all items of UHBVNL with a guarantee of one year from the date of commissioning. including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work
Supply and Erection of Digital Electronic Trivector Meter 3 phase 4 wires 0.5 accuracy for recording reading in KWH / KVARH / KVAH of make and rating approved by UHBVNL with push button display operating system for different kind of readings suitable for dual metering including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work. (Make and specification as per UHBVNL/UHBVNL)
Supply of Disc insulator Rashtriya / Jayshree / BHEL make with Disc fitting TandC type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and erection of 35 Sqmm. 04 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 185 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 240 Sqmm. 3.5 core under ground aluminum Ard. cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work makes as per approved make list attached
Supply and erection of 70 Sqmm. 3 core Cable XLPE (E)11 KV HT aluminum conductor armoured cable ISI mark laid underground duly covered with sand and brick including digging and refiling of trench with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work makes as per approved make list attached
Supply Installation Testing and Commissioning of of Oil filled 11/0.433KV CU Wound 3 Phaze 50 Hz 200 KVA Transformer level 2 ,Standard / Type Is-1180 –,Service – Continuous Yes // Outdoor,Kva Rating 200 Kva Copper Wound,Rated Voltage 11000/0.433 Hsv On Hv Side 12 Kv,Rated Frequency Hz 50 Hz (±3%),Connections : A) Hv Delta B) Lv Star,No. Of Phases 3,Connection Symbol plus 5% -10% @ 2.5% Dyn11,Off Circuit Tap Changer Variation Hv Variation,Ref Ambient Temperature 50°C,Type Of Cooling Onan,Temperature Rise In Oil / Windings 40°C / 45 °C,Losses In Watts: Is Tolerance Applicable….No Load Loss @ Rated Voltage plus Load Loss @ Rated Current: Total Losses As Per 1180 L-3 @50% Losses – 603 W @100% Losses – 1911 W,Impedance Volt. @ Normal Tapping % ( Is Tol Applies) At 75 °C 4.5% ,Induced Over Voltage In Kv: A) 22 Kv Hv B) Lv 0.866 Kv,0,Equipment For Onan Cooling Radiators Mounted On Tank Yes,Terminal Arrangement : A) Hv Cable Box B) Lv Cable Box Bus Bar Extension and Flexible In Customer Scope,Core Material Crgo M4 0.27Mm Or Better,Lv Neutral Position Brought-Out On Tank,Altitude With-In 1000 M,Paint Shade 631 Of Is-5. Matt Finish Paint,Transformer Is – 2026-14,Oil – Mineral Oil Is: 335,Bushing Is – 2099/ Is-3347/ 8603,Type Of Bushings A) Hv 17.5Kv/ 250 Amps Porcelain Bushing B) Lv and Neutral (4 Nos.) Epoxy Bushing 1.1 Kv 1100 Amps,Silica-Gel Breather Provided,Cable Boxes Removable Without Disturbing Core Coil Yes}1 Make as per approved make list attached
J.B.S.Electrical Co.
Janta Electric Store
PS ELECTRIC
M/s JSB Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .