EE(ELECT),FTR HQ BSF JALANDHAR
EE(ELECT),FTR HQ BSF JALANDHAR
RENOVATION UPGRADATION OF 03 NOS 120 MEN JAWAN BARRACK OF 132 BN 170 BN AND WATER WING BSF MADHOPUR UNDER SHQ BSF GURDASPUR SH PROVISION OF DUCT COOLING SYSTEM SERVICE CONNECTION PANEL
2025_BSF_888799_1
151/Engg(E)/Tender/Ftr PB/2024-25
Open Tender
Electrical Works
Works
90 days
109 Bn BSF Madhopur under SHQ GSP
As per tender documents
10 documents required · 10 mandatory
₹0
₹21,921
Yes
22 Jan 2026
6 Dec 2025
16 Dec 2025
6 Dec 2025
15 Dec 2025
6 Dec 2025
6 Dec 2025 - 13 Dec 2025
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Earthing with G.I. earth pipe 4.5 mtr long x 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.a) 200 Amp, 16 KA, TPMCCB
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. A) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. A) Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. A) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. A) Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. A) Above 95 sq. mm and upto 185 sq. mm
Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V, 300 mm sweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required.
Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V, 380 mm sweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required.Make - Havells (Turboforce;FHEHDSPDB150) or equivalent specification make in Crompton/Bajaj/Orient.
Providing and fixing of 20 Watt, 6500K LED batten lighting fixture with extruded polycarbonate directly on ceiling/ wall, including connection with connector, testing and dismantling the existing complete etc. as required. Cat no LHEXACP7IN1W020 Havells(E-Lite LED Pride Plus Neo) make or equivalent model & specification in philips/Crompton-LDLSR-20-CDL/Bajaj
Providing and fixing of 60 watt LED Flood lightmade for energy saving, long life die-cast aluminium IP66 directly on the surface/wall including making connection, testing commissioning etc as required. Make Havells (JETA QUANTO PLUS) equivalent model and specification in Crompton/Bajaj/Philips.
Providing and fixing of maintenance free, dust and moisture free,Engineering plastic injection moding Cooler Body, Cooling pad- 4D honey combo cellulose wet pad with anti bacterial resins fibre body ducting air cooler of following specification : Air flow 18000 CMH, Cooling area 2500 sqft (without ducting), Motor-Inverter high torque motor 380 to 415 volt/50 Hz, 1.1 Kw ( Three phase turbo axial fan) with 1400 RPM, , Air pressure - 180 P.A., Water tank capacity - 35 Ltr, Air outlet size - 670 mm x 670 mm, etc as per direction of engineer in charge. Make - Sky air cooler model - Merqury or equivalent make and model in Symphony, Maharaja, Cool wind complete as per requirement or as decided by Engg-In-Charge.
Providing and fixing of 20 mm nominal outer dia chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plains& brass threaded fittings i/c jointing of pipes & fittings with one step CPVC solvant cement, trenching, refilling & testing of joints complete. make- Ashirvad/vectus/Astral or as per direction of Engg. incharge.
Providing and placing of double layer polyethylene (PVC) water storage tank (ISI Marked) of 500 Ltr capacity with cover and suitable lacking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank.Make- Sintex/Vectus/Frontline or as per direction of Engg. incharge.
Supplying and fixing 0.5 HP centrifugal monoblock motor to supplying water from main water tank to ducting cooler with following specification, make Havells, Model No. -CMM05, size-25x25, HP/KW -0.5/0.37, Head range- 10-15 mtrs, Discharge range-6000 - 2100 L/H, or equivalent make in Crompton/CRI or As per direction of Engg- In -Charge
Suppling and making of duct through 24 Gauge GSS sheet of suitable size ducting will be insulated through high quality insulating material etc as required as per direction of Engineer- in- Charge.
Supplying and fixing of the heavy duty and manualy air controling louvers/ shutters complete with matelic frame as per site requirement.
Providing and fixing of angle iron frame of suitable size for placing of duct cooler made out of 50 mm x 50 mm x 5 mm thick angle iron including making of stand as per site requirement and installation of duct cooler, as per direction of Engg- in -Charge, Make - Jindal/TATA/ equivalent ISI Marked.
SITC of various sizes water protected outdoor (Water proof) hut type compartmentalized type double door cubical panel both side opening having depth up to 600 mm suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated .Panel having separate detachable gland plate, end terminaion as per cable of size,angle iron base frame made out of 50mmx50mmx5mm angle iron of suitable size of the feeder pillar (minimum height 60cm), hinged door, both side opening with locking arrangement, earth bar/stud, led pilot light for phase indicator (R,Y,B) on top, 400A/415V 4 strip aluminum bus bar duly PVC sleeved, connection inter–connection with 25% extra current carrying capacity busbars to MCCBs spreader links and with solid copper conductor cable 10 sqmm/ solid aluminium rod for connection to MCBs and heavy duty connectors of required current carrying capacity to be fixed back side including incoming/Outgoing cables connection for three and single phase MCBs where as required, testing on load and marking of location for incoming and out going distribution i/c grouting the legs in existing floor with 1:3:6 cement concrete foundation and dsimantling the existing panel, incoming/outgoing cable connections etc complete as required i/c dismentling the existing feeder pillar and UG cable. (Panel should be as per design & drawing approved by Engg in charge).LED light min 5 watt with on/off switch to be provided in the panel.
Providing And Fixing Of 100 Amp MCCB three pole Breaking Capacity 10 ka with spreader links for AC Three phase, 415 v Ics=100% Icu, EZC Fixed thermal Magnetic trip unit (TMD) as per details specification in the LT panel and making inter connections with busbar as per the detail specifications mentioned in above new panel item etc as required.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
tender.pdf
Additional Documents • 0.61 MB
BOQ_934183.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .