| 1 | L1₹10.2 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹11.7 L+₹75,135 (6.88%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹12.3 L+₹1.4 L (13.0%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹14.2 L+₹3.2 L (29.8%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹14.2 L+₹3.3 L (30.4%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Jan 2020, 6:00 pmClosed
GE Chandigarh
GE Chandigarh
REPAIR AND REPLACEMENT OF INTERNAL WIRING ITEMS, FITTINGS, FIXTURES AND CERTAIN OTHER CONNECTED ITEMS AT K AREA UNDER GE CHANDIGARH.
2019_MES_303911_1
GE/CHD-70/2019-20
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
Class E Cat b i
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹40,000
Yes
4 Mar 2020
5 Dec 2019
8 Jan 2020
5 Dec 2019
7 Jan 2020
26 Dec 2019
5 Dec 2019 - 12 Dec 2019
Amount
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, pendants, regulators sockets etc, and removing from site and making good disturbed surfaces of walls, floors etc all as directed by Engineer in Charge.
Taking down existing unserviceable MCB DB/TPN along with MCBS complete by disconnecting all as directedby Engineer in Charge.
Taking down existing unserviceable T/Light fitting any type & Capacity
Taking down existing unserviceable sub main wiring with upto 2X6Sqmm aluminum/Copper cable all as directed by Engineer in Charge.
M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 1.5 Sqmm FRLS cable copper conductor for earth continuity and connected to common earth dolly connected including necessary MS terminal box with 3mm thicknes plastic laminated sheet cover of required size for the One light point controlled by one, one way 5 Amps switch, housing the switches, socket outlet etc. all as specified and as directed by Engineer in Charge.
All as per item No. 5 but One ceiling fan/ exhaust fan point controlled by one, one way 5 Amps switch
All as per item No. 5 but One 3 pin socket outlet 5 Amps on independent board
All as per item No. 5 but One 3 pin socket outlet 5 Amps on same board
All as per item No. 5 but One light point controlled by two, two way 5 Amps switches.
All as per item No. 5 but One bell/ buzzer point controlled by one bell push on same board with other switches or on independent board.
M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and modular type metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc., with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. MAKE : Polycab / Finolex / havells NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
All as per item No 12 here-in-before but with 2x6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete. MAKE : Polycab / Finolex / havells/Palaza.
Disconnection and removing the u/s 3x1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor drawn in the existing metal/ PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete. Note : Three runs of cable measured as one unit.
All as per Item No 14 here-in-before but of 3x2.5 Sqmm.
All as per Item No 14 here-in-before but of 3x4 Sqmm.
All as per Item No 14 here-in-before but of 3x6 Sqmm.
Supply and fixing switch piano flush type single pole one way 5 Amps, 230 volts.
Supply and Fixing switch socket flush type universal 2 in 1, 3 pin, 5 Amps 230 volts.
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts.
Supply and Fixing switch socket flush type universal 2 in 1, 3/6 pin 15 Amps 230 volts.
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body.
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type.
Supply and Fixing Buzzer/Ding Dong AC. 230 volts,single pole.
Supply & Fixing 6 Amps 1 way one module switch complete.
Supply and Fixing 6 Amps 2 way module switch complete.
Supply and Fixing 16 Amps one way one module switch complete.
Supply and Fixing 6 Amps bell push one module switch complete.
Supply and Fixing 6 Amps three pin socket two module complete.
Supply and Fixing modular multi socket outlet 16 Amps three pin socket complete.
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete. Make : Pressfit/Modi/ Prestolast
All as per Item No 31here-in-before but of size 25mm
S&F MCB DB, SPN, 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, SPN, 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB DB, TPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc., complete all as specified and as directed.
S&F MCB SP 6-32 Amps 230 volts 10 KA ISI marked of
All as per Item No 38 here in above but of capacity MCB SPN 40 Amps
All as per Item No 38 here in above but of capacity MCB SPN 63 Amps
All as per Item No 38 here in above but of capacity MCB DP 63 Amps
All as per Item No 38 here in above but of capacity MCB TPN 40 Amps
All as per Item No 38 here in above but of capacity MCB TPN 60 Amps
Disconnection and removing the u/s MCB plug and socket unit and S&F Single pole and neutral enclosure with a two pin earth plug and socket complete controlled by one single pole MCB 20 Amps 240 Volts, complete all as specified and as directed.
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X18/20 watts LED, 230Volt energy saving,recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X18/20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x18W to 20W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F as in repair batten for LED tube light 1X9/12 watts LED, 230Volt energy saving,recess, industrial batton type, powder coated, CRC Sheet complete with all as accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed by Engineer in Charge.
Supply and fixing in repair LED tube rod 1X10 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fix in the batten fitting 1x10W, complete all as specified and directed by Engineer in Charge.
Disconnection and removing the u/s light fitting from the fall ceiling carefully and S&F LED (2X2) indirect light fitting circular shape 36 Watts 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
S&F decorative Post top LED 40 Watt for 360* indirect light with IP 65 protection 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection and removing the u/s light fitting from the Surface mountend carefully and S&F Surface mounted LED (1X4) Panel indirect light fitting 40Watts, 230 volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
S&F Ceiling mounted Slim design LED recessed round Downlight with Superior light output and internal driver 22 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
S&F Ceiling mounted Slim design LED recessed Square Downlight with Superior light output and internal driver 18 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed.
Disconnection and removing the U/S LED lamp and S&F LED lamp 9 watts complete all as spfd and directed.
Supply and fix in repair LED Surface mounted round downlight with Superior light output and internal driver 18Watt 230volts with internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
M&L bus bar chamber size 40 cmx25cmx20cm with tin plated copper plated bus strip 4 nos and iron lead and suitable to accommodate 4 pole 63-100 Amps MCCB and provision of MS gland for cable entry with locking arrangement of cap 200 amps 415 volts 50 hz partly flushed to wall and including making good to disurbed potion and colour wash to match the existing surface . Note : MCCB shall be measured and paid separately
Supply and fix in repair MCCB 4 pole 100 Amps 16 KA complete with and including suitable size of MS box with locking arrangement flushed in wall complete all as specified and as directed.
S & F in relacement MCCB, three pole, 160 amps, 25 KA fixed thermal & adjustable magnetic setting complete all as specified and directed by Engr-in-charge.
All as per Item No 60 here in above but of capacity MCCB 125 Amp, 25KA.
All as per Item No 60 here in above but of capacity MCCB 100 Amp, 25KA.
All as per Item No 60 here in above but of capacity MCCB 63 Amp, 25KA.
Disconnecting and removing the unserviceable Geyser electrically operated of capacity 25 to 50 Capacity from its original position including disconnecting the electrical and water connections and to finding out the defects and refixing the same after making the same in serviceable condition in its original position connecting up of Electric and water connections, testing and commissioning complete all as specified and directed by Engg-in-Charge. Note : (i) Spare parts such as Inner copper container, thermostat, element, hot & cold water inter connected pipes and cord flexible will be measured and paid separatley. (ii) Misc items and brazing to the Inner copper container and welding to the outer container as required for satisfactory completion of Job deemed to be included in the unit quoted rate.(iii) Existing glass wool to be used after repairs.
S&F thermostat for Geyser 0 to 80 degrees capacity 230 volts as suits the existing geyser of any type and capacity all as specified and directed by Engg-in-Charge. Make :- Bajaj / Racold / Veenus / usha
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs Heating element 2 KW ISI Marked complate all as specified and as directed. MAKE:-RECOLD / VENUS / GILCO / PREMIER / THEETA
Supply and fix in repairs Safety valve
Supply and fix in repairs Indicating Lamp Round /Square
Supply and fix in repairs 23 to 30 cm long ,10 mm bore C.P Connection with brass union
Supply and fix in repairs Gun metal non return valve ,15 mm bore
S&F for inter connected PVC flexible pipe with both ends check nuts suitable for hot water and connecting the same between the geyser and pipe line. Make : Pressfit/Modi/Prestolast
S&F for inter connected PVC flexible pipe with both ends check nuts suitable for cold water and connecting the same between the geyser and pipe line. Make : Pressfit/Modi/Prestolast
Supply and fix in repairs Apparatus plate for 25 litre
Supply and fix in repairs Bottom plates in two holes for 25liter.
Supply and fix in repairs Plug top 3-pin, 16 Amp
Supply and fix in repairs Rubber O ring /gaskit for 25 ltrs
Supply and fix in repairs Sypon for 25 ltrs
Repair/Maint and Supply and fix in Electric water storage Heater (vertical type Geysers) 25 Ltrs 230 volts, AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement .Geysers to have glass lines tank, fero glass coated container,PUF insulation, glass coated heating element, 8 BAR rated pressurer, thermostat cut off etc.including cutting holes and making good the disturbed surface complete all as specified and as directed by Engineer in charge. Make : Havells/Venus/Bajaj.
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
S&F for replacement to unserviceable flexible PVC insulated lead in lieu of provided with new flexible PVC insulated sheathed copper conductor connection lead 3- core ,size 40/0.0076 cable suitable for Geyser Complete all as specified and as directed by Engineer-in-Charge.
Repair/Maint and Supply & fixing incl testing in repairs of Refrigerator single phase electric driven of 310/320 ltrs capacity complete all as specified and as directed by Engineer-in-Charge. Make: SAMSUNG/LG/Voltas/Godrej
Disconnection and Removing the AC& Cable connection and Copper pipe alongwith all connection items carefully from the existing indoor and out door units and Pump down the refrigerant from out door unit of tonnage 1.5/2 ton including stablizer from the existing position and shifting the AC unit at new place and refixing the out door and indoor units with necessary copper tubing including topping up of gas and connecting stablizer etc for its proper functioning all as direcred and specified by Engineer-in-charge.
Disconnection and removing the old unserviceable Copper Pipe between Indoor & Outdoor Unit and S&F New Copper Pipe of 15mm dia and connecting alongwith Insulation Sleeves to the existing position incl leak testing complete all as directed by Engineer-in-charge
All as per Item No 84 here in above but of capacity 7.5mm dia
Cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
S&F for sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP, 20Amp as in repair complete all as specified and as directed by Engineer-in-Charge.
S&F for 15mm bore stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge. Make :Kiran/Leader/Prayag
S&F for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge. Make :KIRAN/LEADER/PRAYAG
Taking down to 15mm bore steel tubing and connection including cleaning for re-fixing or remove from site complete all as directed by Engineer-in-Charge.
S & F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and directed by Engineer-in-charge. Make - JINDAL/SWASTIK/SURYAPARKASH.
M & L for Outdoor type Straight through, jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 95 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
M & L for Outdoor type end jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 70 to 95 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
M & L for Outdoor type end jointing kit, heat shrinakable for 1.1KV grade UG cable with 3.5/4 core Aliminium conductor of size 35 to 50 Sqmm 3.5 Core complete along with jointing material all as specified and as directed. Make: M-Seal/ Denson /Birla-3M
Supply anf fix in repair AC ceiling fan 1200 mm sweep with remote control conforming to BEE 5 star rating complete with set of aluminium blades, down rod and set of canopy all as specified and as directed by Engineer-in-charge Make : USHA/Crompton/Bajaj.
Supply and fix in repair AC Exhaust fan 250 mm sweep high air delivery low noise completeall as specified and as directed by Engineer-in-charge. Make : USHA/Crompton/ Bajaj.
Supply and fix in repair wall mounting AC fan 400 mm sweep with remote control conforming to BEE star rating completeall as specified and as directed by Engineer-in-charge. Make : USHA/Crompton/Havells/Bajaj
S & F in relacement MCCB, four pole, capacity 160Amp, 25KA
All as per Item No 98 here-in-before but of capacity MCCB 250Amp, 35KA
S & F in relacement MCCB four fole 200Amp, 35KA
All as per Item No 100 here-in-before but of capacity MCCB four fole 125 Amp, 35KA
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standard aluminiu conductor 2 core 6 sqmm in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular.
All as per Item No 102 here in above but 10 Sqmm, 2Core
Supply and fix for as in repair PVC insulated, unsheathed copper conductor cable 10 Sqmm, 3Core flate in shape suitable for submersible cable PVC insulated complete all as specified and as directed by Engineer-in -Charge.
All as per Item No 104 here in above but 16 Sqmm, 3Core
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width incl cutting of road/path and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
Taking down of LT XLPE/ PVC UG cable 1100 V grade, 3.5 core/4 core of size upto 240 Sqmm from the trenches for finding out the fault and relaying the serviceable cable after Repairs in the same trenches complete all as directed by Engineer - in charge . Note1 : - Excavation,RFR,Sand, Brick, cable jointing kits will be measured and paid seperately under the respective items. Note 2:- Replacing the damaged cable with New XLPE, LT UG Cablesof size 3.5 Core 16Sqmm to 120 Sqmm shall be measured and paid seperately under the respective items of the schedule as Supply only.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 3.5 core 16 sqmm nominal cross section in service connections compelte all as specified and directed by Engineer- in - charge.
All as per Item No 112 here in above but 3.5 core 25 sqmm.
All as per Item No 113 here in above but 3.5 core 35 sqmm
All as per Item No 113 here in above but 3.5 core 50sqmm
All as per Item No 113 here in above but 3.5 core 95sqmm
All as per Item No 113 here in above but 3.5Core 120sqmm.
Supply and laying / fixing , GI pipe light grade 40mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directedby Engr-in-Charge.Note: Boring of holes under road etc. shall be measured and paid separately.
All as per Item No 118 here in above but 50mm dia bore .
Taking down unserviceable street light fitting any from the position and replacement of accessories ie driver, surge protector and wiring circut etc and refixing at position complete with connection cable for satisfactory performance all as specified and as directed. Note :- Spares ie LED driver, surge protector and cable will be measured and paid for seperatly under respective item under this schedule here in after as "supply only".
S&F Flood Slim LED light output and internal driver 150 Watts, 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
S&F Flood Slim LED light output and internal driver 120 Watts, 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Disconnection & taking down the unserviceable building light high wattage (45/25 Watts) street light fittings and Supply & fixing energy efficient Intergral type LED 25/30W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte all as specified and directed.
S&F energy saving LED street light 40 to 45 watt luminaire with high power LEDs with lens of beam angle of 120 degree,luminaire made of pressure die cast aluminium body with built in heat sinks, painted with polyurethan/powder coated paint, enclosed with toughened glass including separate compartment for cable and incl sealed/compact driver for easy access during maintenance,suitable for operating on voltage 120 - 270 volt,AC,50 HZ,with surge protection of 5 KV , out put luminous efficiency not less then100 Lumen/Watt , CRI more then 80, conforming to IP 66, class 1 complete all as per Manufacturer's specifications including taking down old unserviceable fittings of any size/ wattage complete all as directed by Engr-in-Charge.
Disconnection & taking down the unserviceable GI bracket of size 25/32 mm dia from the pole / building and M&L for street light bracket made out of 25/32 mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding ,drilling holes as required and fixing with flat iron clamps 50x6mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular /concrete poles/building complete all as specified and as directed by Engineer-in-Charge. Make:Tata/Jindal/swastik
Supply only PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) 3 core for repair of street light wherever required at site and as directed by Engr -in-charge.
LED Driver suitable for up to 45Watt security light fitting.
LED Driver suitable for up to 60/70Watt security light fitting.
LED Driver suitable for up to 100/150 Watt security light fitting.
Cutting & trimming of tree trunks / branches of grith not more than 80 mm falling on or likely to fall on LT over head electrical lines for a clearence of 6 meter on ground from the nearest counductor / pole /earth etc. & desposal of unservicable materials to distance not exc.50 mtrs & clearing of site all as directed by Engg-In-Charge.
M & L as in repair stay assembly complete with accessories as shown in electrical plate No. 1 complete with saty wire stay clamp and loop type insulators and diameter of stay rod in 20 mm complete all as specified.and as directed
Cleaning the area of sewage, electric supply installations by cutting and removing jungle sturts, roots, bushes plants small trees etc and deposited to n.exc 50 mtr to 100 mtr out side installations as directed by Engr-in-Charge.
Cutting of road and Making good with same materials complete all as specified
Supply and fixing poly propylene composite LT phase separator, bolted type for ACSR conductor of any size, suitable for 05 wires, complete all as specified.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits situated inside the K area of M&L for earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to GI wire 4cmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, GI protection pipe of size 20 mm dia upto 7.5 mtr length , funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed by Engineer-in-Charge.
Testing of earth resistance with an earth megger after disconnecting the same from the equipment in presence of MES rep for all electrical equipments such as Transformers, HT/LT Panels, Two pole/4 pole structure, GOD, LA, Pump house Panels, Gen Set etc and writing earth resistance resuit on the earth cover with black or paint and in a separate earth test register including connecting the same after testing complete all as directed.
Supplying and fixing earth continuity conductor or main earthing lead 32mmX6mm, GI strip/earthlead, laid in pipe/fixed on walls or any other position including jointing by GI nuts, bolt and washer atevery joint complete all as specified & directed.
Supply and laying in repair steel water tubing complete with all fittings size 15mm bore medium grade ISI marked IS-1239-1976 Pipe laid in trenches on walls or in any posiion incl taking down complete all as directed by Engr-in-Charge. Make Jindal/Surya/Swastik
Re-fixing old steel tubes and connections of size 20/15 mm bore in new or old position (walls, ceilings, floors/trenches etc.) complete all as specified.
Cutting existing 15mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia, IN REPAIRS, complete all as specified. MAKE: SANT,BIR, ZOLOTA, KIRLOSKAR,PRAYAG
Removal of sludge from tank of size 1.50mx5.0m Depth, Removal of settled sludge, cleaning the sewage from Walls/Ceiling etc. Complete all as specified and as directed by the Engineer-in-charge.
S&F Cob Eyeball downlight LED recessed round Downlight with Superior light output and internal driver 12 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed.
Material and labour for Internal wiring for split unit of any capacity with single core copper conductor FRLS cable as per existing size only complete all as specified and as directed by Engineer-in-Charge.
Supply & filling/charging of gas refrigerant R-22/134a to Window/split type AC 1.5/2 Ton capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
Supply and filling/charging of gas refrigerant R-22/134a for Water Cooler 40/80Ltrs capacity of any make and model including detection of gas leakage, brazing and welding etc., restore the gas pressure and creating vacuum complete all as specified and as directed by Engineer-in-Charge.
Carried out of leak Proof test for detection of leakage of gas from the cooling unit & copper tubing for indoor/outdoor unit of air conditioner, Refrigerator, water cooler with liquid nitrogen gas arresting by gas welding method complete and charging of refrigerator into the Air conditioner/Refrigerator Cooler Complete.
Cleaning of water storage tank, detection of water leakage, brazing / welding to restore the leakage, scraping old paint, completely and painted with 2 coat of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler to external surface complete all as specified and as directed by Engineer-in-Charge.
Disconnecting of all incoming electrical connections to AMF panel to make it neutral, taking out unserviceable power contactor of capacity 400 Amp from the existing panel , taking out unserviceable relay board 24 volts, DC, and connection new contactor of capacity 400 Anp with all connections with connectors with copper thimble of suitable size complete incl following works all as specified and directed by Engineer-in-Charge
Material and labour of LT Panel making electric connections incl wiring by Conductor multistranded PVC insulated welding of doors , fixing hinges, Thimble Refixing of MCCBs and brazing etc incl complet all as spd and diercted by Engineer-in-Charge
Material and labour for lightening arrestor high tension ,expulsion type complete with all fittings, transmission class ,discharge capacity 30 kilo amp ,suitable for 11000 volt grade system fixed in position including disconnecting and taking down old and removal complete all as specified and direced by Engineer-in-Charge.
Aluminium Lugs for cable of size 25 to35 Sqmm
Aluminium Lugs for cable of size 50 to 70 Sqmm
Aluminium Lugs for cable of size 95 Sqmm
LONGIA ENGINEERS
Arun enterprises
M/s Bhisham Raj and Sons
V K Constructive Builders
Electromech Engineers
M/S MATLOOB AHMED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .