| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹22.8 L+₹3.3 L (16.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹22.8 L+₹3.4 L (17.2%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹23.9 L+₹4.4 L (22.7%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹55,800
Closing Date
16 Dec 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
SPECIAL REPAIRS TO ROOM NO 216 F BLOCK PROVN OF LAN NETWORK IN D E F BLOCK AN NCRF AND REPAIR/ MAIN OF AC DUCT INCLUDING CLEANING INSIDE SURFACE OF SUPPLY DUCTS OF HVAC SYSTEM IN CENTRAL AIR CONDITIONING FACILITY AT CABINET SECTT UNDER GE (E/M) BA
2020_MES_394182_1
GE/BH-53/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category a(i) and c(i)
8 documents required · 8 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹55,800
Yes
22 Jan 2021
10 Nov 2020
18 Dec 2020
10 Nov 2020
16 Dec 2020
25 Nov 2020
Amount
Demolition of brick work built in cement mortar including all quoins, pillars etc, complete all as specified and as directed.
M&L Brick work in cement mortar 1:6 using Sub class 'B' brick, straight or curved on plan exc 6m mean radius complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc including raking out joints, hacking for key scrubbing down with water etc, complete all as specified and as directed.
M&L 15 mm thick plastering in cement mortar 1:6, on brick work or concrete surfaces, finished even & smooth without using extra cement, in patches complete all as specified and as directed.
M & L for applying two coats of plastic emulsion paint of any tint over a coat of primer including 2 to 3mm thick wall care putty on newly plastered surfaces complete all as specified and as directed. (Make: Asian Royale Shine or equivalent of Make Mentioned in PS)
M & L for applying two coats of plastic emulsion paint of any tint over a coat of primer including 2 to 3mm thick wall care putty on existing plastered surfaces including complete removal of existing treatment complete all as specified and as directed. (Make: Asian Royale Shine or equivalent of Make Mentioned in PS)
Taking down chowkhat with shutter, without taking off shutters of any description area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and directed.
S&F factory made uPVC white colour sliding glazed window having three track three panels sliding window with fly proof S.S wire mesh (Two Nos. glazed & one No. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm, both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality including 6mm thick float glass & SS wire mesh complete all as per approved drawing, as specified and as directed.
S & F in repair door closer hydraulically regulated, designation No 3, universal type, suitable for door shutter 851 mm to 1000 mm in width and of weight 61 to 80 Kg each, aluminium alloy body, extruded section complete all as specified and as directed.
S & F in repair Antique finish, brass, mortice lock, 65 mm, 6 lever, vertical type, with duplicate key and handle set complete all as specified and as directed.
M&L for scraping and cleaning of Wooden doors / wall panelling to remove existing polish, filling putty or the required hardeners for repairing of any wooden marks, scratches or scars and treated with putty /primer to obtained similar texture and melamine coating on the surface with approved shade on the surface doors to obtain smooth and uniform looking complete all as specified and as directed.
M&L for GI metal false ceiling, laid in plain regular edge, white colour tiles of size 595X595X0.5mm thick with 8mm drop made of GI sheet having galvanizing of min 120 gms/Sqm (both side inclusive ) & electro statically polyester powder coated of thickness 60 microns (min) including factory painted after bending ceiling grid shall be following min sizes: main T section(24X38X0.3mm 3m long), Cross 'T' section (24X25X0.3mm 6m long), wall angle (24X24X0.3mm 3m long), hanger rod 4mm dia, Adjust clip (85X30X0.8mm), soffit cleat (27X37X25X1.6mm), Dash fastener (12.5 mm dia) including dismantling of old false ceiling of any description complete all as specified and as directed.
M&L for providing 12mm thick laminated wooden flooring with rubber backing as per approved sample, approved size of interlocking panels, Hi gloss PU polished surface of French bleed designs with weather shield max and V groove on all four sides including 12mm thick ply board wherever required including dismantling of old flooring complete all as per manufacturers instructions, as specified and as directed.
M&L in repair wall panelling fabricated out of 18mm thick (IS:303 BWR/BWP grade) commercial ply board, fixed to wall as per design and wall panelling with 4mm thick teak wood face veneer ply, design approved by Engr-in-Charge including 25X25 mm teak wood beading at edges and corners of matching lots with 6mm grove between panel as per the existing design, including preparation of surface and polishing the same of approved shade and colour, inclusive of 3 coats of melamine polish complete to proper line, level, and plumb as per instruction and approval complete all as specified and as directed.
S&F in repair 12mm thick coloured toughened designer stained glass (as per sample approved by user) in fixed partitions including powder coated aluminium framework of approved section as specified by Engr-In-Charge having minimum thickness 2mm complete all as specified and as directed.
S&F in repair 50mm wide, wooden venetian blinds, made out of 3mm thick, fine-grained bass wood flat wooden slates available in natural colours complete all as specified and as directed . (Make: Vista/Marvel/Hunter Douglas/Mac
S&F 20mm dia, non metallic, PVC, rigid conduit Including of all tees, bends elbow reducers bell mouth tube end and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc but exclusive of junction boxes complete all as specified and as directed.
All as per item No 17.00 here in before but 25 mm dia complete all as specified and as directed.
S&F 1 or 2 Module PVC surface box suitable for fixing 1 module cover plate complete all as specified and as directed. Make Legrand Cat Part No 573491 or equivalent model of Make L&T/Crabtree or any other Make mentioned in PS.
S&F 1 Module PVC cover plate complete all as specified and as directed. Make Legrand Cat Part No 573428 or equivalent model of Make L&T/Crabtree or any other Make mentioned in PS.
S&F 1 Module RJ-45 (Information Socket) Cat 6, UTP computer socket complete all as specified and as directed. Make Legrand Cat Part No 575700 or equivalent model of Make L&T/Crabtree or any other Make mentioned in PS.
Labour only for fixing LAN cable in conduit provided under item Nos 17.00 & 18.00 here in before in presence of user Rap complete all as specified and as directed. Note for item Nos 17.00 to 22.00: (i) All work related to LAN network shall be executed by the contractor in presence of user Rep. (ii) LAN cable shall be supplied on requirement bases by the user's rep directly to contractor at the time of laying of cable.
M & L for cleaning inside surface of supply ducts of HVAC system carefully by using high power vacuum, air compressor, robotic camera, air hammer, special nozzles, air sweep with other required accessories to make the surface completely free of mill scale, dirt , dust and any other foreign particles by taking special care and submitting inspection report of dust before and after cleaning of ducts using colour video inspection complete all as specified and as directed.
Supply, assembling and errection in repair C & SS rectangular/square duct made out of 20 gauge GI sheet `L' shaped hollow profile, duty factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints including 8mm galvanised iron suspended rod and fastener, nut, bolt, washer etc complete of size required or as directed by Engineer in Charge complete all as specified and as directed.
All as per item No 24.00 here-in before but using 22 gauge GI sheet complete all as specified and as directed.
All as per item No 24.00 here-in before but using 24 gauge GI sheet complete all as specified and as directed.
Notes for item Nos 23.00 to 26.00:-
The entire work shall be carried out at various floor in multi-storey building by OEM (M/s TRANE) or his authorised dealer only. MOU/Authorisation Letter from OEM (M/s TRANE) shall be submitted/uploaded by the bidder along with technical bid.
Duct cleaning shall be carried into various stages depending on the nature of the work involved. All area of the duct shall be decontaminated including the plenum and other far most areas.
The duct shall be decontaminated using a robot that performs the inspection of the duct as well as the decontamination process using compressed air. It agitates the dust using highly flexible whip, which shall be attached on top of the robot and shall be connected to the compressed air line/Air Compressor. The agitated dust shall then be collected by a Vacuum Chamber, which sucks the agitated dust from one end of the duct.
The contractor shall not use any chemical to apply in the duct. It shall be purely dry cleaning and shall involve non-toxic and environment friendly method of cleaning.
Vacuum Chamber shall be with a capacity of generating 5000 CFM of negative air pressure and capable of collecting 99.9% of the dust.
The diffusers and grills present in the duct work shall be thoroughly air washed without its removal.
All the equipment’s shall be adequately protected and covered by the contractor. The floor shall be cleaned from the dust accumulated during the work by the contractor.
NAD certification shall be submitted by the contractor/OEM before execution of work.
An edited video consisting of the initial inspection and after work completion shall be submitted by the Contractor/OEM to the client along with the report.
UV sterilisation of duct is mandatory along with cleaning and shall be done by the OEM through contractor. The quoted rates shall be inclusive of UV Sterilisation of Duct and nothing extra shall be admissible to contractor on this Account.
The non-hazardous dust/debris collected shall be disposed by the contractor at approved location without any extra cost to deptt. or packed and returned to the department/User, if Department/user requires it for further testing/analysis.
Hazardous dust/debris collected shall be packed according to the directions from the customer and returned to the customer for disposal.
Exact quantity of Duct shall be measured and paid as per actual measurement at site.
The work shall be carried out during day/night on working day, Sunday or holiday as per site available by the user.
OEM (M/s Trane) Through contractor shall submit the schedule for duct cleaning to Engineer In Charge in writing prior commencement of work on ground for necessary permission by the user.
JIWAN DASS THAREJA AND SONS
M/S Sunil Steel Works
GLIBS CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .