Public Works Department
H Basavaraj TA
Installation of Electric Poles and Phase Wire In Maski CMC Limit, Maski Constituency Under CM Amruth Nagarothan Phase-4 for the Year 2024-25
PWD/2025-26/EL/WORK_INDENT22360/CALL-2
PWD/2025-26/EL/WORK_INDENT22360/CALL-2
Open
Electrical
Electronic Documents, First(One Cover)
PWD Division Office Raichuru
6 documents required · 6 mandatory
₹1,050
₹84,000
6 Sept 2025
6 Sept 2025
11 Sept 2025
Installation of Electric Poles and Phase Wire to Kyatnatti Anjenaya Temple
RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Ordinary soil"
Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at
workspot) NOTE:- Consolidated amount for both loading and unloading. "
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM"
11 kV, Horizontal Cross Arm - Mild Steel (MS)
Caution/Danger Board
GI Barbed Wire (12 Mtr)
Spiral Earth Electrode
11 kV GI Pin for 11 kV Ceramic Shell Insulator
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)"
for guy set Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Ordinary soil"
Fixing Danger Board
Fixing of V-Shape/Horizontal cross arm including Single Top
Support Brace and Insulator fixing"
Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,)"
Digging of Pit for GUY SET
Complete Guy set (material code 2811101)
Providing poles and Transformer to IB maski
11 kV, Horizontal Cross Arm - Mild Steel (MS)
digging pit for guy set ordinary soil
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)
11 kV Ceramic Pin Insulator (Shell only)
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 KgWL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transforme...
Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM"
7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM"
Digging of Pit for GUY SET
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding
digging of pits"
Wiring for lighting/power circuit using one of FRLS PVC
insulted 1.1 kV grade multi strand copper with low
conductor resistance 2.5 Sqmm single core wire in open
are concealed system of wiring with...
PVC Wire - 120 Sqmm
Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil"
LT Protection Kit
(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)"
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)"
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007"
63 kVA, Aluminum Wdg, Star 2 (5 Star)
Erection of RCC Pole 9.5 Mtr long 350 Kg WL in a pit of 2.0
Mtr depth for 33KV line"
Fixing of 3 Nos Lightning Arrestor including wiring
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross
arm and wiring"
Fixing of LT Protection Kit
Digging of Pit for providing GI Pipe type Earthing
Providing Transformer to Kyatnatti Anjaneya temple
11 kV, Horizontal Cross Arm - Mild Steel (MS)
digging pit for guy set ordinary soil
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)
11 kV Ceramic Pin Insulator (Shell only)
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 KgWL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transforme...
Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM"
7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM"
Digging of Pit for GUY SET
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding
digging of pits"
Wiring for lighting/power circuit using one of FRLS PVC
insulted 1.1 kV grade multi strand copper with low
conductor resistance 2.5 Sqmm single core wire in open
are concealed system of wiring with...
PVC Wire - 120 Sqmm
Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil"
LT Protection Kit
(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)"
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)"
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007"
63 kVA, Aluminum Wdg, Star 2 (5 Star)
Erection of RCC Pole 9.5 Mtr long 350 Kg WL in a pit of 2.0
Mtr depth for 33KV line"
Fixing of 3 Nos Lightning Arrestor including wiring
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross
arm and wiring"
Fixing of LT Protection Kit
Digging of Pit for providing GI Pipe type Earthing
Ward No-23 Providing Transformer Sanbal road Shivkumar house Basavraj House
11 kV, Horizontal Cross Arm - Mild Steel (MS)
digging pit for guy set ordinary soil
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)
11 kV Ceramic Pin Insulator (Shell only)
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 KgWL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transforme...
Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM"
7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM"
Digging of Pit for GUY SET
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding
digging of pits"
Wiring for lighting/power circuit using one of FRLS PVC
insulted 1.1 kV grade multi strand copper with low
conductor resistance 2.5 Sqmm single core wire in open
are concealed system of wiring with...
PVC Wire - 120 Sqmm
Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil"
LT Protection Kit
(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)"
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)"
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007"
63 kVA, Aluminum Wdg, Star 2 (5 Star)
Erection of RCC Pole 9.5 Mtr long 350 Kg WL in a pit of 2.0
Mtr depth for 33KV line"
Fixing of 3 Nos Lightning Arrestor including wiring
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross
arm and wiring"
Fixing of LT Protection Kit
Digging of Pit for providing GI Pipe type Earthing
Installation of Electric Poles and Phase Wire In Maski CMC Limit
RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Ordinary soil"
Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at
workspot) NOTE:- Consolidated amount for both loading and unloading. "
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM"
11 kV, Horizontal Cross Arm - Mild Steel (MS)
Caution/Danger Board
GI Barbed Wire (12 Mtr)
Spiral Earth Electrode
11 kV GI Pin for 11 kV Ceramic Shell Insulator
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)"
for guy set Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Ordinary soil"
Fixing Danger Board
Fixing of V-Shape/Horizontal cross arm including Single Top
Support Brace and Insulator fixing"
Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,)"
Digging of Pit for GUY SET
Complete Guy set (material code 2811101)
Installation of Electric Poles and Phase Wire In Maski CMC Limit, Maski Constituency Under CM Amruth Nagarothan Phase-4 for the Year 2024-25
RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as
11 kV, Horizontal Cross Arm - Mild Steel (MS)
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8
digging pit for guy set ordinary soil
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Ordinary soil"
11 kV Ceramic Pin Insulator (Shell only)
Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at
workspot) NOTE:- Consolidated amount for both loading and unloading. "
DISC Insulator 45 kN Porcelain
11 kV GI Pin for 11 kV Ceramic Shell Insulator
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM"
11 kV, Horizontal Cross Arm - Mild Steel (MS)
For 25/63/100 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/62 Dtd 24.11.2018)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 KgWL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transforme...
Caution/Danger Board
Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM"
GI Barbed Wire (12 Mtr)
Spiral Earth Electrode
7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM"
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and
anchoring arrangement as per approveddrawing. (Excluding excavation of PIT)"
Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding
digging of pits"
Fixing Danger Board
Wiring for lighting/power circuit using one of FRLS PVC
insulted 1.1 kV grade multi strand copper with low
conductor resistance 2.5 Sqmm single core wire in open
are concealed system of wiring with...
PVC Wire - 120 Sqmm
Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil"
Fixing of V-Shape/Horizontal cross arm including Single Top
Support Brace and Insulator fixing"
LT Protection Kit
(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018)"
Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,)"
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)"
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007"
Digging of Pit for GUY SET
Complete Guy set (material code 2811101)
63 kVA, Aluminum Wdg, Star 2 (5 Star)
Erection of RCC Pole 9.5 Mtr long 350 Kg WL in a pit of 2.0
Mtr depth for 33KV line"
Fixing of 3 Nos Lightning Arrestor including wiring
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross
arm and wiring"
Fixing of LT Protection Kit
Digging of Pit for providing GI Pipe type Earthing
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
formats-1-10 new 25-26.xls
Others - Format 1 to 10 • 0.10 MB
kw-2 wi 22360.doc
Tender Document • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .