Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.7 CrAccepted-Finance AT CANAL AVENUE WARD NO 16 PO DIST BARGARH 768028 ODISHA | BARGARH | BARGARH | ODISHA | 768028 | ₹10.7 Cr | L-1 | Accepted-Finance Accepted by Tender Committee |
| 2 | L-2₹11.2 Cr+₹44.6 L (4.16%)Rejected-Finance AMBAGACHAPADA BHAWANIPATNA KALAHANDI ODISHA | KALAHANDI | ODISHA | 766001 | ₹11.2 Cr+₹44.6 L (4.16%) | L-2 | Rejected-Finance Rejected by Tender Committee |
| 3 | L-3₹11.3 Cr+₹55.5 L (5.18%)Rejected-Finance AT PO BAZARPADA DHARAMGARH KALAHANDI 766015 ODISHA INDIA | KALAHANDI | ODISHA | 766015 | ₹11.3 Cr+₹55.5 L (5.18%) | L-3 | Rejected-Finance Rejected by Tender Committee |
| 4 | L-4₹11.3 Cr+₹63.0 L (5.88%)Rejected-Finance | ₹11.3 Cr+₹63.0 L (5.88%) | L-4 | Rejected-Finance Rejected by Tender Committee |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically disqualified by Technical Committee |
Tender Value
₹12.6 Cr
EMD Value
₹12.6 L
Closing Date
20 Jan 2026, 5:00 pmClosed
MD OLIC BBSR
OFFICE OF MD OLIC N 17 2 NAYAPALLI BHUBANESWAR
Installation, Electrification, Energisation and Commissioning of Borewells in KALAHANDI District Pkg-04 BID ID-10
2025_OLIC_123864_1
9939 DT-24.12.2025
Open Tender
Civil Works - Lift Irrigation Schemes
Percentage
180 days
KALAHANDI
Please refer Tender Document DTCN
2 documents required · 2 mandatory
₹11,800
Yes
₹12.6 L
Yes
17 Sept 2026
29 Dec 2025
21 Jan 2026
29 Dec 2025
20 Jan 2026
29 Dec 2025
29 Dec 2025 - 8 Jan 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Conducting VES test 3 nos for each borewell including 20% cost on failed VES test as per direction of Engineer-in charge | 400 | No | 8,202.19 | ₹32,80,876 |
| 2 | Labour for drilling a perfectly vertical bore hole of 200mm dia for over burden and 150 mm dia for hard rock specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs with PLC facility (1200 cfm/300 psi) as required to suit the site condition as per direction of the Engineer-in-charge including use of own rigs with its accessories, tools, plants and consumables etc. for lowering of 200mm dia PVC/GI Pipes for housing with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC casing pipes if required to prevent collapse of over burden is to be provided by the contract including lowering and withdrawing after completion of the bore well) upto 100mtr. | 37,320 | No | 953.78 | ₹3,55,95,069.6 |
| 3 | Lowering the casing pipe of 200mm dia as per the necessity from ground level upto 45 meters depth and fitted and fixed up in perfectly vertical position, including cutting, threading and slotted pipe and supply and fixing all jointing materials, tools and plants etc. complete and keeping the top of the casing pipe threaded including plugging the bore well to prevent entry of foreign materials from above 0 to 30 meter and above. | 6,640 | No | 185.47 | ₹12,31,520.8 |
| 4 | Cost of 200mm dia PVC (Sch-80). Casing Pipe of reputed make as per ASTM 1785/2021 specification. Manufacturer name should prominently be marked with CIPET test certification in the body of the pipe in indelible ink or stenciled to the satisfaction of Engineer-in-charge | 275.2 | mtr. | 1,423.88 | ₹3,91,851.78 |
| 5 | Cost of 200mm dia PVC C.S. Casing Pipe of reputed make as per IS-12818/2010 specification. Manufacturer name should prominently be marked with CIPET test certification in the body of the pipe in indelible ink or stenciled to the satisfaction of Engineer-in-charge | 6,604.8 | mtr. | 932.26 | ₹61,57,390.85 |
| 6 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the well including suppply and use of all necessary equipment and labour as per the direction of the Engineer-in-charge | 400 | No | 6,836.7 | ₹27,34,680 |
| 7 | Conducting yield test through pumping for minimum 6-8 hours including supply of required pump set having 3.5 LPS discharge at 70 Mtr. head, 15KVA D.G. Set and a container of 200 ltrs. Capacity as required to suit the site condition as per the direction of the Engineer-in-charge including supply of tools plants labourers for lowering and lifting the pump set and measuring the yield of the bore well . | 400 | No | 6,098.41 | ₹24,39,364 |
| 8 | XLPE insulated ( heavy duty ) armoured aluminium electric cable of size 3 core x 6 sqmm. with allumium conductor for use in 3 phase system in working voltage up to 1100 volt at 50 HZ confirming to IS 7098 part -I- 1988 & as per the particulars mentioned . | 4,000 | No. | 77 | ₹3,08,000 |
| 9 | Cost of 63 mm. dia. HDPE 80 (PN 10) delivery pipe as per IS-4984 / 2016. | 13,000 | mtr. | 143.42 | ₹18,64,460 |
| 10 | Cost of 63 mm. dia. HDPE 80 (PN 6) delivery pipe as per IS-4984 / 2016. | 9,000 | mtr. | 95.66 | ₹8,60,940 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.44 MB
10KALAHANDI04DTCN.pdf
Tender Documents • 8.44 MB
BOQ_573471.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .