| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹36.0 L+₹2.0 L (5.94%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.3 L+₹6.3 L (18.7%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹41.9 L+₹8.0 L (23.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹43.2 L+₹9.3 L (27.3%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
1 Feb 2022, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIR/ MAINTENANCE / SERVICING / FILTERATION OF TRANSFORMER EARTHING SYSTEM, LIGHTINING PROTECTION AND OTHER CONNECTED WORKS AT NAVAL AREA AND COAST GUARD AREA UNDER GE HADDO, PORT BLAIR
2022_MES_499990_1
8596/GE/H/PB
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Haddo Port Blair
Class D Category b(ii)
9 documents required · 9 mandatory
₹500
GE Haddo
₹60,000
Yes
1 Mar 2022
6 Jan 2022
5 Feb 2022
6 Jan 2022
1 Feb 2022
20 Jan 2022
6 Jan 2022 - 15 Jan 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding. 1.5m in depth for foundation etc. or laying of cables n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil all as specified.
Returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in any type of soil.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point.
Supply & fix Pin type, composite silicon rubber polymeric type insulator 150mm height, 150mm dia for 11000 volts grade, 5 kN with ECR glass rod, forged steel top and bottom, silicon rubber housing and weather sheds, including one galvanized mild steel spindle, galvanized iron washer, spring and one galvanized iron nut all as specified and as directed including taking down existing unserviceable insulator. [Make: GK Electricals/ BHEL/ Jayshree/ WS Industries/ Southern Insulators/ Mysore/ ABB]
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted/ unserviceable cross arms.
Supply & fix long rod insulator, composite silicon rubber polymeric type 290mm height, 100mm dia for 11000 volts grade, 45 kN with ECR glass rod, forged steel tongue and cleaves, silicon rubber housing and weather sheds all as specified and as directed including taking down existing unserviceable disc type insulator. [Make: GK Electricals/ BHEL/ Jayshree/ WS Industries/ Southern Insulators/ Mysore]
M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in coping of pole all as directed including use and waste of necessary form work including weathering, slightly rounded or chamfered angles and throating all as specified and as directed by Engineer-in-Charge.
Material & Labour for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of pole all as directed including use & waste of necessary form work including weathering, slightly rounded or chamfered angles and throating all as specified and all as specified and as directed by Engineer-in-Charge.
Material & Labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 32X6mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion all as specified and as directed by Engineer-in-Charge.
Supply & fix Earth continuity conductor or main earthing lead of GI earth strip of size 32x6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, fixed with necessary clamps and nuts, bolts etc. including taking out unserviceable strip all as specified and as directed by Engineer-in-Charge.
Material & Labour for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to copper earth strip of 20x3mm size by means of bolts, nuts, check nuts and washers of copper and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of Schedule Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
Supply & fix Earth continuity conductor or main earthing lead of copper earth strip of size 20x3mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, fixed with necessary clamps and nuts, bolts etc. including taking out unserviceable strip all as specified and as directed by Engineer-in-Charge.
Material & Labour for isolating, cutting, removing the existing damaged end termination and Supply & fix outdoor end termination, Heat shrinkable type suitable for HT UG cable, XLPE insulated of size 3 core x 70 to 95 sq.mm, 11KV [Earthed] grade including preparation complete all as specified and as directed by Engineer-in-Charge. [Make: M-Seal/ Super seal/ 3M/ Denson/ Raychem]
All as per item no.13 here in above but for HT UG cable of size 3 core x 120 to 240Sqmm, 11KV grade complete all as specified and as directed by Engr-in-charge. [Make: M-Seal/ Super seal/ 3M/ Denon/ Raychem]
Material & Labour for isolating, cutting, removing the existing damaged end termination and Supply & fix indoor end termination, Heat shrinkable type suitable for HT UG cable, XLPE insulated of size 3 core x 70 to 95 sq.mm, 11KV [Earthed] grade including preparation complete all as specified and as directed by Engineer-in-Charge. [Make: M-Seal/ Super seal/Denson/ Raychem/3M]
All as per item no.15 here in above but for HT UG cable of size 3 core x 120 to 240Sqmm, 11KV grade complete all as specified and as directed by Engr-in-charge. [Make: M-Seal/ Super seal/ 3M/ Denon/ Raychem]
Taking up the corroded/ deteriorated GI pipe from the road crossings/ obstructions and supply & laying GI Pipe 100mm dia medium grade including cutting existing road and making good with PCC after completion of laying of GI pipes all as specified and as directed by Engineer-in-Charge. [Make: Tata/ Prakash/ Jindal/ Zenith/ Bansal]
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3.5 core x 95 sq.mm. (laid in trenches, ducts, pole, wall etc.) including taking out old unserviceable LT cable from trenches/pole/ducts etc. all as specified and as directed by Engineer-in-Charge: Note: (i) Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation earth work will be measured and paid separately.
All as per Item No. 29 herein before but cable of size 3½ core x 120sq.mm
All as per Item No. 29 herein before but cable of size 3½ core x 240sq.mm
All as per Item No. 29 herein before but cable of size 3½ core x 400sq.mm
Supply and lay graded stone aggregate of 63mm size, spread and leveled around 4 pole/ 2 pole structure/ transformer yard all as specified and all as specified and as directed by Engineer-in-Charge.
Removing old burnt/ damaged end termination for LT cable 1100 Volt grade, 3½ core 70 to 150sq.mm and supply and making new end termination with suitable size of lugs duly crimped after isolating supply to transformer/ LT pillar box/ LT panel and disconnecting burnt/ faulty cable from the bunch of cable gland and reconnecting the cable with new nuts, bolts and washers of nickel chromium plated applying petroleum jelly after end termination, testing and commissioning complete all as specified and as directed by Engineer-in-Charge
All as per Item No. 23 herein before but for cable of size 3½ core x 185 to 300sq.mm
All as per Item No. 23 herein before but for cable of size 3½ core x 400 to 500sq.mm
M&L for preparation of old decorated surfaces of walls of transformer plinth by scraping and wire brushing and applying one coat of weather shield (APEX) paint complete all as specified and as directed.
Cutting bushes, levelling the area around E/M installation such as sub stations, 4/2 pole structure etc. including surface excavation not exceeding 30cm deep and averaging 15cm deep and averaging 15cm deep and getting out roots, jungles etc. throw away not less than 50 mtr from the site and making good all as specified and as directed by Engineer-in-Charge.
M&L for writing SM No MES No. on plants and machinery with synthetic enamel paint/ stickering with letters of height 8cm complete all as specified and as directed by Engineer-in-Charge.
Taking out LT panel/junction box of any size by disconnecting all incoming and outgoint cables including breaking of PCC foundation for transporting and fixing in other place safely as directed including re-fixing of LT panel board with new PCC foundation, angle supports, nuts, bolts and washers including transportation like crane, truck etc without distrubing existing electrical system complete all as specified and as directed. Note:- (i) Necessary excavation earthwork, PCC for new place work will be measured and paid seperately. (ii) The cost of braking PCC and removing of Poles is deemed to be incuded in the Quoted rate. (iii) The cost of transportation for crane, truck etc to shift the removed panels from one pleace to another place is deemed to be included in the Quoted rate.
M&L for online centrifuging (filtration/ dehydration) of transformer oil including checking dielectric strength of oil before and after filtration for transformers located under GE Haddo area with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of oil. Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work. (iii) The contractor shall ensure no wastage of transformer oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge. (v) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration
M&L for preparation of old painted surfaces of floor mounted inddor/ outdoor type transformer from 100 KVA to 500 KVA capacity by cleaning/ rubbing with coarse cloth/ wire brushes to remove dust deposits, oil, grease and repainting by applying one spray coat of synthetic enamel paint without disturbing/ damaging the electrical net work system/ equipment including marking of details of capacity/ rating/ incoming/ outgoing in capital English alphabets all as specified and as directed by Engineer-in-Charge.
All as per Item No. 31 herein before but from 750KVA to 2000KVA.
S&F in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 2000 KVA transformers complete including connecting with proper rubberized gasket and necessary suitable GI fittings of existing type for fixing the assembly complete all as specified and as directed by Engineer in Charge. Make : Patel Electrical Industries or equivalent recommende by OEM
Supply, filling and for topping up the transformer with new transformer oil duly filtered with filtration plant. Make : Power Oil Ltd/Savita/Castrol. Note : (a) The transformer oil shall be type EHV confirming to IS - 3351983. (b) Mineral oil grade shall be used. (c ) The transformer oil should have a high dielectric strength not less than 60 KV/Min.
Taking down burnt defective drawnout/inlet Valve (Brass 1 1/2" size) and supply and fixing new drawn out/Inlet valve (brass 1 1/2") suitable for any make of 100 to 2000KVA Transformer all as specified and as directed by Engineer-in-charge.
Taking down defective unserviceable LT bush porcelain insulator and supply and fix new LT bush porcelain insulator with oil seal for transformer outdoor/indoor up to capacity of 500 KVA including opening the top cover for fixing of LT Bush if necessary complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 36 herein before but from 750KVA to 2000KVA.
Taking down defective unserviceable HT bush porcelain insulator and supply and fix new HT bush porcelain insulator for transformer outdoor/indoor up to 500KVA including opening the top cover for fixing of LT Bush if necessary complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 38 herein before but from 750KVA to 2000KVA.
M&L for isolating the HT supply of transformer, disconnecting HT and LT connections of transformer by opening clamps, bus bar extension and isolating the cables from transformer, outdoor of 100 to 2000 KVA capacities, checking of transformer pressure release valve, oil condition and carrying out tests such as HV/LV megger test, ratio test, magnetic balance test, short circuit test including opening the inspection cover/top lid after drain out of oil as required to check the lead condition from winding to bus rods including necessary soldering/jointing, fixing of new sleeves etc, and charging of transformer and making all necessary connections / assembly & control circuits all as specified and directed by Eng-in-Charge.
Taking down unserviceable sheet gasket (Cork sheet), Supply and fix synthetic rubberized cork sheet gasket 6mm thick 2' x 3' size approx sheet thick as required at site for top cover HT/LT bushes at places existing and tighting all the bushings and top cover to avoid any oil leakages of capacity 100 KVA to 500 KVA complete all as specified and as directed by Engineer-in-Charge.
All as per Item No. 41 herein before but from 750KVA to 2000KVA.
Disconnecting defective out door/indoor transformers, 11KV/433 V of various capacities up to 2000KVA from HT/LT sides taking down transformer oil completely, storing oil in suitable container (to be provided by the contractor), lifting the top cover and core assembly carefully and checking the conditions, refilling the transformer Coil completely after necessary repairs, re-fixing core assembly including fixing the top cover and painting to transformer complete all as specified and as directed by Engineer-in-Charge. Note : (a) Rewinding of transformer shall be measured and paid separately. (b) In case of major repairs/replacement in transformer, which can not be undertaken at site, the transformer shall be shifted to civil workshop and refixed at site after rewinding by Hydra and connected accessories (complete transformer). (c) Dismantling of core and repairs shall be measured and paid separately. (d) Rate quoted shall be deemed to be inclusive of Shifting of transformer to workshop and back. (e) Complete gaskets, nuts and bolts shall be replaced by the contractor and the quoted rate is deemed to be included.
M&L for lifting of transformer core of capacity 100 to 500 KVA and keeping the core inside oven chamber to remove moisture and increasing of the insulation value of core and drying the core assembly for minimum 3 days at a temp of 120°C. Note :- (a) Cost for lifting/lowering the core of transformer by crane is inclusive. (b) Labour for fixing the connection/removal of connection inside the heating chamber is inclusive. (c) Power consumption for heating core for improving insulation value is inclusive. (d) Temperature 120°C to be maintained and inclusive in the rate quoted.
All as per item no 44 above but of capacity 750 KVA to 2000 KVA.
Taking down burnt defective high tension copper coil of Transformer and supply and fix new HT copper coil made out of proper/ required as per the existing size copper wire enameled of high quality matching with the existing impedance and pre- insulation all as specified and directed. Note : (a) The cost of coil shall be inclusive of varnish sleeving of insulating material. (b) Cost of taking down the clamps, upper channels and core & HT links and re-clamp, positioning with separators, brazing etc completely shall be deemed to be included in the quoted rate.
Taking down burnt defective Low tension copper coil/copper strip of Transformer/DG Set alternator and supply and fix new LT copper coil/copper strip of existing size made out of proper/ required copper wire enameled of high quality matching with the existing impedance and pre- insulation all as specified and as directed by Engineer-in-Charge. Note : (a) The cost of coil shall be inclusive of varnish sleeving of insulating material. (b) Cost of taking down the clamps, upper channels and core & LT links and re-clamp, positioning with separators, brazing etc completely shall be deemed to be included in the quoted rate.
Taking down unserviceble tinned copper bus bar of various sizes from HT/LT side cable bushing rods from the transformer of 500KVA to 2000KVA capacity by disconnecting all HT/LT cables and supply and fix electrolyte tinned copper bus bar of suitable size and length including making holes as required at site to the transformer LT/HT side cable bushing rods and re-connecting of all disconnected cables complete all as specified and as directed by Engineer-in-Charge.
Supply and fix offload tap changer assembly suitable for 11/433KV, any make upto 500KVA transformer with 7 tapping position including opening top cover, conservator etc as fixed against repairs all as specified and as directed by Engineer-in-Charge.
All as per Item No.49 above but of capacity 750 - 2000 KVA.
Dismantling of existing cement mortor, taking down the existing transformer platform complete all as specified and as directed by Engineer-in-Charge.
Material and labour for air termination single pointed aluminium rod 12 mm dia, 300mm long and taking down the unserviceable/broken one including removing from site all as specified and as directed by Engineer-in-Charge.
Material and labour for aluminium strip of size 25 x 3.15 mm with saddle or fixed with screws etc., for roof conductor and down conductor, above ground including taking down unserviceable/broken aluminium strip all as specified and as directed by Engineer-in-Charge. Note : Fixing of insulators will be paid separately.
Material and labour for test point terminal block made of gun metal or phosphorus bronze of size 75 x 25 x 10 mm drilled and screwed including 3 Nos. 8 mm dia, 25 mm long hexa headed screwed including taking down unserviceable one and remove from site all as specified and as directed by Engineer-in-Charge.
M&L for shifting of Transformer of capacity upto 2000KVA from MES power house to variours substations/transformer locations at haddo area by road and removing the faulty transformer from the plingth and fixing/errecting of the healthy tansformer with the hydra/crane support, making necessary HT/LT cable connections, earth connections and restoration of power supply as and when required at site all as specified and as directed by Engineer-in-Charge.
SKV Engineering
Sree Tirumala Enterprises
ISLAND SALES ENTERPRISES
BHARAT MULTITECH INDUSTRIES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .