Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC R O VILLAGE POST OFFICE DOHAG TEHSIL JOGINDER NAGAR DISTRICT MANDI H P | L1 | Accepted-AOC Accepted | |
| 2 | L2₹38.6 L+₹1.3 L (3.36%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.0 L+₹2.6 L (7.01%)Rejected-AOC R O VILL AIMA P O TEHSIL PALAMPUR DISTT KANGRA H P | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.9 L+₹3.5 L (9.41%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.3 L+₹3.9 L (10.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹53.6 L
EMD Value
₹86,082
Closing Date
7 Jul 2022, 11:00 amClosed
Executive Engineer
JSV Division Rohru
SH C O RCC Intake Chambers 3 Nos CO RCC Storage Tank of various capacities 15000 ltr cap 1 No 10000 ltr cap 2 nos C O Retaining wall to protect the storage tank 15 50 mtrs Providing fencing around the Civil structure Head weir and Layin
2022_HPIPH_62345_1
JSV-RD-AB-Tender 22-5870-94
Open Tender
Civil Works
Item Rate
180 days
Rohru Town
Tender Document
8 documents required · 8 mandatory
₹800
Yes
EE Rohru
₹86,082
Yes
3 Sept 2022
30 Jun 2022
7 Jul 2022
30 Jun 2022
7 Jul 2022
30 Jun 2022
Amount
Excavation in foundation trenches etc. in earth work lift upto 1.50 mtrs. stacking the excavated soil not more than 3 mtr. Clear from the edge of excavation and then returning the stacked soil in 15cm. Layer when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth all kinds of soil within all leads and lifts and as directed by the Engineer-in-charge.
Excavation in foundation and trenches etc.(for pipes & pits) in earth work in all kinds of soil such as pick work, jumper work, blasting soft or hard rock or by chiselling soft or hard rock where blasting is prohibited in all leads and lifts including trimming / dressing of sides and bed, stacking the excavated soil clear from the edge of excavation and returning the excavated soil after completion of work in 15cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated soil complete in all respect as per direction and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:6:12(1cement: 6sand: 12 graded stone agg.40mm nominal size) and curing complete excluding cost of centering and shuttering including complete in all respect as per direction and to the entire satisfaction of the Engineer-in-Charge. in Foundation and plinths
Providing and laying cement conc. 1:3:6(1 cement:3 sand:6 graded stone agg. 40mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in foundation and plinth with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete 1:5:10(1cement:5sand:10 graded stone aggregate of 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining walls/breast walls, the size of plums shall usually be 150mm to 300mm as per H.P.P.W.D specification including all leads and lifts
Providing and laying cement conc 1: 1½ :3 (1cement:1:1½ sand :3 graded stone agg. 20mm nominal size) and curing com-plete excludidng cosot of form work and reinforcement for RCC work in foundation and plinth with in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge in:-
Foundation,footing basis of columns & the likeand mass concrete.
Walls (any thickness) but not less that 0.10 Mtrs. hick including attached pilasters buttresses plinth and string course from top of foundation upto floor two levels.
P/L cement conc. 1:2:4(1 cement:2 sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
In suspended floor roofs landing shalves & their support balconies,beams, girders bressumers cantilevers upto floor two level
Providing form work with steel plate 3.15 m.m thick welded with angle iron 30x30x5 m.m so as to give a fair finish including centering ,shuttering, propping etc. height of propping and centering below supporting floor to ceiling upto all heights and removal of the same for in-situ reinforced conc.and plain conc.work in :-
Vertical surfaces such as walls (any thickness)portions and the like including attached pilaster buttresses plinth and string course and the like
Flat surface such as soffits and suspended floors, roofs, landings and the like: Floors etc. up to 200mm in thickness within all leads and lifts
Edge of slab and break in floor and walls under 200cm. Thickness within all leads and lifts.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position i /c binding wire complete up to floor two level complete in all respect as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.
Providing and laying No fine concrete in 1:4 (1cement: 4stone aggregate 40mm nominal size) and curing complete with weep hole or pores etc. curing complete excluding cost of form work and reinforcement for reinforced concrete work including all leads and lifts.
Random rubble masonary/Polygonal rubble masonary (coursed or brought to courses with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 in cement mortar 1:6 ( 1 cement : 6 sand)as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
C/O Dry rubble masonry in breast wall/ retaining wall, and revetment walls and parapet wall etc. including all leads and lifts
Boulder filling behind retaining wall/crate wall as per the satisfaction and direction of Engineer in Charge.
Wire crates made of G.I.wire filled with boulders with square cut faces against the wire, (Boulder filling to be measured and paid for separately) i/c all leads and lifts. (a) G.I.Wire 5mm thick corresponding to SWG-6(15Cmx15cm.Mesh).
Wire crate made of G.I wire filled with boulders with square cut faces against the wire (Wire crate to be measured and paid for separately)in all leads and lifts as per the direction of Engineer-in-Charge.
Providing and fixing of 1.80 Mtrs. high fencing with 2.50Mtrs.angle iron posts 2.5Mtrs.centre to centre with nine horizontal line and two diagonals of galvanized steel barbed wire (IS: 278-1962 Type-I) weighting 9.38 Kg./ per 100Mtrs.strained fixed to posts with G.I. staples, i/c painting of posts complete cost of post, struts, and storing bolts shall be paid for separately i/c in all leads and lifts as per the entire satisfaction & direction of the Engineer In-charge .
Providing and supplying of fencing post 2.50 Mtrs. long made of 50x50x5mm MS. angle and section having eleven holes at equal spacing for barbed wire. Fencing post should be welded with 20 Cm. long 45x45x5mm hold fast. The angle should be painted with red oxide paint and as per PWD. Specification.
Providing and fixing Man Hole cover with frame & stair case of M.S. sheet and angle size 600x600mm(weight of Main-Hole & stair case arenot less 35kg & 75 kg). Including welding and cutting charges as per direction of Engineer in Charge.
Laying jointing of G.I pipes (L.G) ,tube fitting in trenches i/c earth work complete for inlet and scour pipe including all leads and lifts.32 mm (L.R)
Providing and fixing gun metal wheel valve (with hand wheel ) including all leads and lifts
Providing and placing in horizontal layers filtering media duly graded, screened cleaned and washed as per specified in all respectas per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.
Bottom Layer: Broken stone 50mm to 75mm
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.
10mm Cement plaster in single coat in fair side of brick /stone masonry for interior plastering up to floor two level including arises internal rounded angles chamfers and/or rounded angels not exceeding 80mm in earth and finished even and smooth including all leads and lifts a) 1:3 (1Cement:3sand).
Laying, jointing and testing in trenches galvanized mild steel screwed and socketed pipes of following diameter and class, tube fittings in trenches i/c carriage of pipes from Sub-Divisional Store to site of work,(Earth work in trenches to be measured and paid for separately) complete in all respect and to the entire satisfaction of the Engineer-in-charge: (LR):
15mm dia (LC).
20mm dia (LC).
25mm dia (LC).
32mm dia (LC).
Yogesh Chauhan
subhash chand Govt Contractor
Ankit Gictu Contractor
Harsh chauhan
ANKUSH
sanjeev kumar
CHATTER SINGH RATHORE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .