Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹121.4 CrAdmitted-Finance | ₹121.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹139.5 CrAdmitted-Finance SATNA MADHYA PRADESH 485005 | SATNA | MADHYA PRADESH | 485005 | ₹139.5 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical D NO 958 T V S COLONY ANNA NAGAR WEST EXTENSION CHENNAI 600101 | CHENNAI | CHENNAI | TAMIL NADU | 600101 | - | - | Rejected-Technical Financial BQR not Satisfied |
| 4 | Rejected-Technical 175 2 SOUTH STATE BANK NAGAR CHETTIPALAYAM ERODE TAMIL NADU 638002 | ERODE | TAMIL NADU | 638002 | - | - | Rejected-Technical Technical BQR not Satisfied |
| Sl No | Description | Qty | Unit | Shah Infra Towers Pvt Ltd L1 | UNIVERSAL CABLES LIMITED L2 |
|---|---|---|---|---|---|
| 1.00 | Schedule I | 1 | No. | 33,14,25,486.5 ₹33.1 Cr | 40,50,81,131.04 ₹40.5 Cr |
| 2.00 | Schedule II | 1 | No. | 66,51,72,705.6 ₹66.5 Cr | 73,81,93,800.53 ₹73.8 Cr |
| 3.00 | Schedule III | 1 | No. | 3,21,02,942.3 ₹3.2 Cr | 3,87,85,122.1 ₹3.9 Cr |
| 4.00 | Total GST Amount (@18%) | 1 | No. | 18,51,66,204.19 ₹18.5 Cr | 21,27,70,809.66 ₹21.3 Cr |
Tender Value
Refer Docs
EMD Value
₹83 L
Closing Date
23 Jul 2025, 3:00 pmClosed
Chief Engineer/ Transmission
Chief Engineer/ Transmission V Floor, TANTRANSCO HQ, 144, Anna Salai, Chennai- 600 002.
Design,Detailed Engg,Supply,ETC of 230/110kV AIS SS with ICTs, swtgrs, CRP,SAS,CtrlRoom,Civil Works at Kongalnagaram and Provision of 1no 230kV Bay at exg Anaikadavu 400kV AIS SS on Total Turnkey Basis under Pkg 8 of GEC2 funded by MNRE and KFW
2025_EB_560628_1
T-2320
Open Tender
Electrical Works
Tiruppur
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹83 L
Yes
Chennaii
2 Dec 2025
23 May 2025
24 Jul 2025
23 May 2025
23 Jul 2025
17 Jun 2025
23 May 2025 - 6 Jun 2025
30 May 2025
Amount
Schedule I
Schedule II
Schedule III
Total GST Amount (@18%)
Description of Work / Item(s)
Amount
Clearing juliflora jungla with uprooting including labour,lead and disposed away from the site
Clearing juliflora jungla with uprooting including labour,lead and disposed away from the site
Cutting and levelling the ground using JCB / Hitachi/ other machineris as per the direction of site engineer including all labour lead and lift etc complete.
Supplying and Filling the yard with approved quality of gravel including cost of gravel levelling with JCB / other machineris , consolidation as per specification & with power roller including all labour lead and lift etc complete.
Earth work excavation for Hard Gravelly soil SS 20B for foundation including all labour charges including initial lead, lift, etc. complete.
Earth work excavating and depositing on bank in Soft disintegrated rock, laterite, soft rock or kankar, with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in MR and DMR not requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in MR and DMR requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Providing anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m alround the building using BIFLEX-C termite 250ml for 10lit of water etc. complete.
Supplying and filling M.sand for foundation and basement including watering and consolidation including cost of sand all labour lead lift etc. complete
Plain cement concrete M15 with minimum cement content not less than 240 kgs using 12 to 20mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
RCC M 25 with miimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. ( excluding cost of steel reinforcement. For Raft concrete.)
RCC M 25 with minimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, for columns including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. ( excluding cost of steel reinforcement. For column concrete.)
Upto Ground floor roof
RCC M 25 with minimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, for Grade beams,plinth beams including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Retaining wall, cable duct side walls and cover slabs etc.,
RCC M 25 with min. cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, for Lintels including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Continuous lintel concrete.
Ground floor
RCC M 25 with min. cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, Shunshade including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. but excluding cost of steel reinforcement. For Sunshade concrete 60cm projected, 80mm Tk. at wall and 50mm Tk. at free end.
Ground floor
RCC M 25 with min. cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, Roof beams including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Roof Beam concrete.
Ground floor
RCC M 25 with minimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, for 130mm thick slab including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Roof slab concrete 130mm Tk.
Ground floor
RCC M 25 with min. cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, for side wall including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Roof slab concrete 100mm Tk. Ground Floor
PCC M20 with min. cement content not less than 300 kgs using 12-20mm graded hard machine broken granite stone 100mm thick , flooring including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. For Floor concrete.
RCC M 25 with min. cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone, precast slab including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. ( excluding cost of steel reinforcement.) For precast cover slab concrete.
Providing steel reinforcement for RCC works including cost of steel rod binding wire and placing in postion of the steel reinforcement all materials, lead and lift etc., complete.
Brick work in CM 1:5 using II class chamber burnt bricks for basement & superstructure including cost of all materials, all labour lead lift etc ., complete. super structure, including cost of all materials, all labour charges, lead, lift, etc. complete.
Ground floor
Brick work in CM 1:3 using II class chamber burnt bricks for partition wall, including cost of all materials, all labour charges, lead, lift, etc. complete.
Plastering with cm 1:5, 12mm thick for walls including cost of cement, all materials,curing, labour, lead and lift etc., complete.
Plastering with cm 1:3, 12mm thick for ceiling, beams, sunshade,plinth etc. including cost of cement, all materials,curing, labour, lead and lift etc., complete.
Weathering course over roof slab with PCC M20 to an average thickness of 100mm and to required slope and providing one course of Solar Reflective Ceramic Tiles 305x305x7 mm, set in C.M 1:3 mixed with crude oil 10% by weight of white cement and pointing with colured cement mixed with crude oil. (including water proofing treatment over roof to prevent leakage)
Damp proof course using cement mortar 1:3, 20mm thick with water proofing compound including cost of all materials lead lift etc., complete.
Painting two coats of newly plastered ceiling surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting the inside walls with two coats of best quality interior emulsion of approved colour over a interior primer coat of all materials, etc., complete.
Painting the outside walls with two coats of exterior emulsion over a primer coat of approved colour and quality including cost of all matreials, lead and lift etc., complete.
Painting with 2 coats acid proof paint of approved colour over a priming coat of white cement for battery room including cost of all materials, labour, lead, lift etc complete for interior walls.
Flooring with approved acid proof tiles over cement mortor 1:3 20mm thick in floor including pointing with white cement finishing the joints flush pointing the surface etc complete.
Flooring with vetrified tiles of size 600x600 mm of approved Quality, design & colour (Johnson/Kajaria/Somany/ or equivalent make)laid in cement mortar 1:3 -20mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the joints, including cost of all materials, labour, lead, lift, etc. complete
Dadooding walls with approved quality of glazed tiles, size and design (johnson or equivalent make) laid in cement mortar 1:2 -10mm thick including pointing with same coloured cement using 0.4kg/sqm, finishing the jointsand pointing flush with the surface , including cost of all materials, labour, lead, lift, etc. complete.
Supply and fixing in position of double leaf anodised aluminium glazed main door using door outer frame 101.60 x 44.45 x 2.10mm @ 1.608Kg/M and door inner frame side and vertical 53.70 x 44.45 x 2.30mm @ 1.238 Kg/M, door bottom section 83.50 x 44.45 x2.40mm@ 1.679Kg/m and diveder and top of door frame 47.62 x 44.45x 2.17 mm@ 1.072 Kg /M glazing clips of 17.30 x 19.0 x 0.60mm @ 0.083 Kg/M with std.quality hydraulic floor spring, automatic door closure, rubber beedings, hinges, handle, etc., with 5.50mm thick sun cool glass, etc., complete. Double leaf main door
Supply and fixing in position of anodised aluminium partially glazed single leaf door using outer frame 101.60 x 44.45 x 2.10mm @ 1.608Kg/M and door inner frame side and vertical 53.70 x 44.45 x 2.30mm @ 1.238 Kg/M, door bottom section 83.50 x 44.45 x2.40mm@ 1.679Kg/m and diveder and top of door frame 47.62 x 44.45x 2.17 mm@ 1.072 Kg /M glazing clips of 17.30 x 19.0 x 0.60mm @ 0.083 Kg/M, rubber beedings, hinges, handle, hydraulic floor spring, automatic door closer etc, and with 12mm tk. one side laminated board at bottom half portion and top half portion with 5.50mm thick sun cool glass including cost of all materials, lead, lift, etc, complete Single leaf door
Supply and fixing of solid PVC door with frame made out of rigid thermo vinyl polymer extruded section ofsize 62mmx51mm with 2mm wall thickness,shall be reinforced with special polymeric rods of size 255mmx30mmx25mm and with EPDM gaskets along the frame. The door shutter frame of 40mm thickmade out of one piece moulded rigid thermo vinyl polymer extruded sectionof size 25mmx40mm with 2mm wall thickness is mitered and joinedat corners by stainless steel/ aluminium screws. The infill of the door shutterconsists of a seamless one piece multichamber hollow rigid thermo vinyl polymer sectionof size 762mmx35mm with 1mm wall thickness and with prelaminated glossy finish on either side of door shutter of suitable size including cost of all materials lead lift etc., complete. .
Supply and fixing in position of UPVC Windows of size 1.2mx1.5m as per ISS 1038-1958 (1245 ISS)using window frame bottom two track sliding with glazing clips rubber gaskets ,sliding wheel & 5.5 mm thick sun cool glass panelling including cost of all materials ,locking arrangements ,labour,lead,lifts etc complete.
Supply and fixing of UPVC Ventilator of 0.75m x0.45 m fully glazed lover type as per standard specification with approved section for frame and glass 4mm thick including cost of all materials ,lead,lift ,labour etc complete.
Fabrication, supplying and fixing of MS framed single leaf with GI sheet 18 gauge door using MS angle 40x40x6mm for door frame and MS angle 35x35x5mm for shutter frame with necessary stiffeners using MS flats of size 19x5mm including painting with two coats of enamal paint over one coat of red oxide paint including cost of all materilas, labour, lead, lift etc, complete.
Fabrication, supplying and fixing of MS angle framed window half glazed and half shutter using MS angle of size 35x35x5 mm for window frame and 25x25x5mm for shutter and MS flats 19x4 mm thick for window grill with locking arrangement including painting with two coats of enamal paint over one coat of red oxide paint including cost of all materilas, labour, lead, lift etc, complete.
Supplying and fixing MS grills for windows ,ventilators ,gates MS angle .Flat and square rods as directed by the Engineer at site including painting two coats with enamel paint over a coat of primer cost of materials, labour, lead and lift etc., complete.
Supplying and fixing of Europian type water closet with flushing cistern of Neycer/Parry ware with P"" or "S" trap ,seat cover 15 mm dia connectin hose .2 nos 15 mm dia CP angle valve ,hand shower -1 No. including cost of all materials ,lead lift etc complete as directed by department Engineer at site
Supplying and fixing in position IWC ORISSA PAN of size 580X420mm white glazed earthen ware of approved make & quality with 'P' or 'S' trap conforming to IS - 2556 Part XII [Parryware or Equivalent] with sand cushion and forming flooring around the cloast using 40mm broken brick jelly in lime concrete 1:2:5 [1/lime, 2/sand & 5/brick jelly] 100mm thick and finishing the top to required slope and giving connection to sewer line including the cost of all materials, labour, lead, lift, T&P, etc. complete.
Supplying and fixing in position White glazed Flat back urinal - Size 455 x 350mm of approved make and quality [Parryware -Aquaseal urinal or equivalent] and with PVC pipe connection [Kohinoor], 32mm PVC waste pipe [Kohinoor], 12/15mm GM wheel valve ISI, fixing the urinal to the valve with necessary TW plugs, brass screws etc, connecting to the water main as directed at site including the cost of all materials abour, lead, lift, T&P etc. complete.
Supply and fixing of wash basin of size 560x410mm white and of approved quality and make[Parryware or equivalent] with 12/15mm dia brass CP pillar tap [waterman], 32mm PVC waste pipe [Kohinoor], 12/15mm CP angle cock [ISI], 15mm brass nipple, 15mm nylon connection [Kohinoor] etc. fixing the basin in the wall with GI/Alu. brackets and rag bolt and nut, giving necessary water connection etc., and mirror with beveled edge fixed with suitable CP brass screws etc., complete.
Supplying and fixing of 110mm dia, best quality ventilating shaft 3.65m height with PVC cowl at top and fixing in poistion inlcuding cost of all materials, curing labour, leads and lits etc., complete.
Supplying and fixing in position 110 mm dia PVC soil pipe- 6kg/sq.cm [Finolex or equivalent] with special clamps & PVC shoe at bottom including the cost of all materials, labour, lead, lift, T&P, etc., complete
Supplying and filling with 40mm HBG metal in dispersion trench, rain water harvesting pit including cost of metal, all labour, lead,lift, consolidation etc. complete.
Supply and fixing 110mm PVC down fall pipe 6kg/cm2 avonplast or Finolex make with required bend, tee and GI wall clamp at 90cm intervals including cost of materials, labour, lead and lift etc., complete.
Providing and laying PVC high density 15 ksc pipe including cost of all materials, labour, etc., complete.
50 MM DIA PVC PIPE
40 MM DIA PVC PIPE
32 MM DIA PVC PIPE
25 MM DIA PVC PIPE
20 MM DIA PVC PIPE
Supplying and fixing in position of gun metal gate valve leader make of best quality including cost of materials lead lift labour etc complete.as directed by department Engineer at site
50 MM dia
40 MM DIA
32 MM DIA
20MM DIA
Supplying and fixing in position of gun metal wheel valve leader make of best quality including cost of materials lead lift labour etc complete.as directed by department Engineer at site
25mm dis
20mm dia
Providing and fixing of long body chromium plated heavy duty metal tap of 12mm size including cost of all materials, labour, etc., complete.
Supplying and fixing in position aluminium partition partly glazed & partly paneled above 12mm thick both side prelaminated boards [ MDF exterior grade] and 5mm thick machine frosted float glass 9modi, saint gobine or Equivalent0 using aluminium box section of not less than 63x38.4x2mm x 1.174kg/m for vertical @ 955mm c/c approx and horizantals[4Nos] including cost of all materials, labour, lead, liftT&P etc. complete.
Providing inspection chamber with manhole cover depth varying from 0.75 to 1.5m including cost of all materails lead lift etc complete.
M.H with SFRC 0.6x 0.6
Fabrication & erection of Name Board of vinyal sticker laminated in alco panel using 18 gauge M.S. sheet with outer in suitable angle and stiffener at the rear side of MS flat supported on M.S. channel ISMC height from the G.L. and 1m.
Supplying and fixing in position sun control polyester flim, reflective type 75 microns thick (gareware or equivalent )including the cost of all materials, labour, lead, lift, T&P, etc. Complete.
Providing false ceiling by using 12.50mm thick perfonated gypsum board in panels using 6mmGI rod suspender ,16 gauge aluminium "T" and "L" including all materials, labour, lead and lift etc., complete.
Supplying and sticking the name / designation stickers in doors identifying the rooms including cost of material, labour etc. complete.
Providing locking arrangements with 6 lever Godrej lock with 3 keys including cost of all materials, labour, lead and lift etc., complete.
Providing Sintex water tank of capacity of 1000 lits including cost of material, labour, lead, lift, transportation and placing in position over head room etc., as directed by the engineer at site.
Supplying and fixing in position of Stainless steel grade 302 , hand rail of 75mm pipe to height of 1000 mm and support of 25mm above square / round including cost of all materials, labour, lead, lift, T&P etc. complete.
Providing MS channels and chequred plates of 8mm thick inside the control room including cost of all mateiral,labour, lead, lift painting etc., complete
Supplying and fixing black granite stone 0.90 x 0.60 m size Engraved Foundation detail and year of construction fixing in wall at entrance, Digital wall clock 2 Nos, floor coir mat 2000x600 for Entrance 1000x500 - 2 No. for office of approved make and quality including the cost of all materials, leads, lifts etc., complete
Painting the name of Substation over entance wing wall in both Tamil and English using colouring with enamel paints etc., including cost of all material, labour, lead, lift etc., complete
Drilling of borewell in various soil /hard rock etc., including transportation of Power drill machineries first by taking a pilot bore of 180 mm dia and then drilling 150 mm dia at the bore well point fixed at site.( 0-200m)
Drilling of borewell in various soil /hard rock etc., including transportation of Power drill machineries first by taking a pilot bore of 180 mm dia and then drilling 150 mm dia at the bore well point fixed at site. -(200-350m )
Supplying and providing Heavy duty 180 mm PVC casing pipe with ISI
Supplying &Inserting 40mm dia HDPE hose pipe of make FLOWTEC or equivalent ISI make for suction inside the borewell with supporting clamp including cost of all materials, labour, lead & lift etc., complete as driected by the department engineer at site.
Supplying & Inserting 20mm dia HDPE hose pipe of FLOWTEC or equivalent ISI make for air pipe inside the borwell with supporting clamp including all materials, labour, lead & lift etc., complete as directed by the department engineer at site.
Supplying providing and fixing of 15 mm Dia GI pipe " B " class
Supplying and fixing of 180 mm dia PVC End cap approved best quality
Fixing of bore well point by well qualified geologist labour T & P including all lead lift etc complete as directed by the department engineer at site.
Supplying and erection of 5 HP air compresser 3 phase electrical motor of approved brand with all related accessories as per IsI in all respect including oil level indicator switch board with 3 Nos. test lamp, 3 Nos. fuse carrier, 1 No. 15AMPS DPIC swithch with L&T make starter with guard and providing earthing to main with no. 8 tinned copper rod and 6' long 40mm dia GI pipe for earting and earth pit filled with charcoal and salt as per standard spectification and laying motor bed by concrete and placing motor over bed, labour charge for placing motor over bed including cost of all materilas lead and lift etc, complete as driected by the department engineer at site.
Supplying and erection of 2HP mono block 3 phase electrical motor of approved brand with all related accessories as per IsI in all respect including oil level indicator switch board with 3 Nos. test lamp, 3 Nos. fuse carrier, 1 No. 15AMPS DPIC swithch with L&T make starter with guard and providing earthing to main with no. 8 tinned copper wire rod and 6' long 40mm dia GI pipe for earthing and earth pit filled with charcoal and salt as per standard spectification and laying motor bed by concrete with placing motor over bed, labour charge for placing motor over bed including cost of all materilas lead and lift etc, complete as driected by the department engineer at site.
Wiring with 2 x 1.5 sq.mm (22/0.3) PVC insulated SC unsheathed multistrand Copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with Steel switch box and 5A F.T switch with continuous earthwire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (SD 23)
Supply and run of 2x 1.5 sq.mm (22/0.3) PVC insulated Multistrand unsheathed copper conductor of 1100 V grade. (SD 43)
Wiring with 2x1.5 sq.mm (22/0.3) PVC insulated SC unsheathed Cu.conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall ,with 150x100x113mm Tw switch box with 3 mm thick hylum sheet cover for 5 A 3 Pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC Plug point.(SD38)
Wiring with 2 x 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor cable of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150 mm x 100 mm x 113 mm Steel switch box with 3 mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion, with suitable colour for concealed power plug point. (SD 40)
Supply and fixing of 3 phase 4 wire 4 way ICDB of 16 A per way with 32 A TPN MC switch with suitable MS cable entry boxes trunking box and internal connections on suitable angle iron frame work. (SD 173)
Supply and fixing of 32 A TPNMC switch on suitable angle iron frame work with MS cable entry box with earth connection only. (SD 163)
Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated multi strand unsheathed copper conductor of 1100 V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour. (SD 60)
Supply and fixing of single flu. fitting complete with LED light with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from the terminals to the fitting with flu. tube.
4' X 20w Single Industrial type fitting
4'x20 W Single Box type fitting
Supply and fixing of 4'x20 W Twin type Mirror optic suspension type fitting (Philips /Crompton / Wipro) complete with louvers cover complete with LED light with conduit pipe suspension, with PVC unsheathed copper leads from the terminals to the fittings with flu. tubes. (SD 91)
Supply and fixing of W.T bulk head fitting (Philips / Bajaj / K.Lite / Crompton Greaves) suitable for LED lamp with guard and 1No 20 W LED bulb.
Supplying and fixing of 2 x 36 W LED Street light fittings crompton make (SFE 1624 HSBN) including cost of all materials, labour, lead, lift etc., complete, as per standard specification.
Supply and fixing of fancy glass shade and 18 W LED for BH point.
Supply and fixing of 1400 mm (56") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. (SD 107)
Supplying and fixing of 1200mm sweep AC ceiling fan with electronic requlator with 300mm down rod on the existing clamps of approved quality of Crompton/Rally/ usha/bajaj including cost of all materials lead lift etc complete.
Supply and fixing of 375 mm (15") sweep (heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
Supply and fixing of 600 mm sweep (heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
Supplying and fixing of RCCB safe trip of appd LEGRAND , ISI make , 25amps with suitable box including cost of all materials labour, lead, lift, etc., complete as per standard specification.
Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make). (SD 179)
Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work. (SD 234)
Supplying and fixing of split Air Conditioner (3 phase -2 Ton capacity), Industrial grade of approved make (Dikin or equivalent) with all accessories including stabilizer( V guard) with reputed make including cost of all materials, leads, lift, fixing charges, etc., complete as per standared specification complete.
Supply and fixing of 20 Amps DP plug and socket in sheet enclosure with 32 A DP MCB in flush with wall with earth connection (For AC plug) [Legrand (MDS) / Hager (L&T) make]. (SD 134-B)
Supplying and laying of 4 core 16 Sqmm copper PVC armoured LTUG cable including cost of cable, lead, lift, labour charge, etc., complete.
Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 Amps per way with 63 A TPN MC switch with suitable trunking box MS cable entry and internal connection in suitable angle iron frame work,with earth connections. (SD 176)
Supplying and fixing of 4 pole 32 Amps Isolator 1 No with MCB box 4 pole including terminal block for testing purpose at relay and CC room, cost of all materials, lead, lift, labour charge, etc., complete.
Supplying and laying 25 mm dia 10 kg PVC pipe of approved quality for AC unit water drain pipe including cost of all materials, lead, lift, labour charge, etc., complete.
Drilling 4½" dia hole in brick wall and fixing suitable size PVC pipe in wall for providing cables for out door condencing unit including cost of all materials, lead, lift, labour charge, etc., complete.
100 mm dia
50 mm dia
Supplying and fixing 5/8" copper tube for connecting AC panel to AC out door unit including cost of all materials, lead, lift, labour charge, etc., complete.
Laying fixing if Controflex (slicagel) compound in around ventilator for protection of rain water.
Supplying and fixing of 100mm dia. stoneware pipe with open joint and covered with pan tiles including all cost of materails lead lift etc complete.
Supplying and fixing in position of best quality mirror (22" x 16") with aluminium frame over wash basin including cost of all materials labour, lead, lift, etc. complete as directed by the engineer at site
Supplying and fixing of approved quality of aluminium towel rod with powder coating of size (2 ft) and fixing the same over teak wood round block and soap tray (PVC) in bath room including cost of all materials lead lift labour etc complete as directed by department Engineer at site
Supplying and fixing of PVC shower and Nickle control valve complete
Supply & fixing marble partition of 25 mm thick 600 mm wide and 1200 mm high including necessary cement mortar with white cement concrete for urinals as directed by department Engineer at site
Supplying, Fixing of buzzers with 5A bell push switch etc complete.
Providing opening for cable,Exhaust fan AC duct, water pipe line etc in brick work/RCC in building and retaining wall& cble duct including cost of machinaries labour etc complete
Brick wall
RCC concrete
Painting with two coats of approved enamel paint over one coat of primer for all M.S door window ,gater etc. including cost of all materilas,labour ,lead and lift etc. complete.
Providing projected border 20 Cm width in CM 1 : 3. 20 mm thick including cost of all materials, labour, lead, lift, etc., complete.
Providing projected border 7.5 Cm width in CM 1 : 3. 20 mm thick including cost of all materials, labour, lead, lift, etc., complete.
Supply and fixing of multi way PVC floor trap 100 x 75 mm as directed by the Engineer at site cost of all materials, labour, lead, lift, etc., complete.
Suply and fixing double side polished 38 mm thick cuddappa slab for cub boards including cost of all materials, labour, lead, lift, etc., complete.
Providing Decorative terracoata tiles over the sun shade slabs / portico etc., and painting two coats including cost of all materials, labour,lead, lift, etc., complete.
Manufacturing, supplying and fixing in position of RCC jally of 5 Cm thick in Cement concrete 1:2:4 using 20 mm machine crushed stone jelly (Excluding cost of reinforcement steel) including cost of mould, finishing , curing, lifting, fixing in position et
Supplying and laying in position of ceramic channel of 150mm wide for drain of best quality and approved make complying with standard specifications and as directed by the engineer at site including the cost of all materials labour, lead, lift, T&P etc. complete.
Providing sealant materials in the expansion joint in the terrace floor up to a depth of 52mm, cleaning the edges properly to remove dust, stain, oil etc, finishing the edgs with polimer modified mortar viz. mixture of cement, sand with water & poly propylene with water proofing compound, applying Epoxy adhesive on the grooves of 1000 series products & also on the concrete surface, compress & install 'REACT 1000 - A01-044' of vexcolt/ Uk or equivalent for 40mm width in the expansion joint, finishing the system flush with to existing surface, including the cost of all materials, lead, lift, T&P, etc. complete.
Forming expansion joints in roof slab with 18 gauge GI sheets as per 2B plan W.No 2/41 revised TNBP specification.
Supply steel furniture manufacture by 'TANSI' or any other ISI mark including cost of all materials, labour, lead and lift etc., complete. sample to be approved by department Engineer
S Type chair (Local rate)
Three drawer steel table
Steel side rack open type 4 self
Steel half bench
Revolving Chair
Operator Table 6'x5'
PVC Chair of reputed make
Plinth for breaker, Equipments, LLM, ICT, DG set and Compound Wall
Earth work excavation in hard stiff clay, stiff black cotton hard red earth,shales, muram, gravel, stoney earth and earth mixed with small size boulders in all soils with an initial lead, lift, etc., complete.
Earthwork excavation in MR and DMR not requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in hard rock requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in hard rock by wedging & Chiselling .with an initial lead of 10m and lift of 2m etc complete.
Supplying and filling M sand for foundation and basement including watering and consolidation in15 cm layers including cost of sand all labour lead lift etc. complete
Plain cement concrete M15 with min.cement content not less than 240 kgs using 12 to 20mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
RCC M 25 mix with minimum cement content not less than 362 kgs, using 12-20mm graded hard machine broken granite stone without formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for raft concrete ( excluding cost of steel reinforcement.)-matt Concrete
RCC M 25 with minimum cement content not less than 362 kgs, using 12-20mm graded hard machine broken granite stone with formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for Pedestal and other concretes ( excluding cost of steel reinforcement.)
RCC M 25 with minimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone with formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for Pedastal and other concretes ( excluding cost of steel reinforcement.)
Plain cement concrete M20 with minimum cement content not less than 300 kgs using 12 to 20mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
Providing steel reinforcement for RCC works including cost of steel rod binding wire and placing in postion of the steel reinforcement all materials, lead and lift etc., complete.
Providing casing pipe line for laying cable to breaker plinths with 110 mm dia PVC pipe 6 kg/cm2 including all specials and cost of all material, lead, lift, etc., complete as per standard specification.
Supplying and fixing the paver block colour coated of 65 mm thick to the foot path of the operational switches inside the 230/110 yard including the cost of all materials, leads, fixing charges, lifts etc., complete
Brick work in CM 1:5 using II class chamber burnt bricks for basement & superstructure including cost of all materials, all labour lead lift etc ., complete. super structure, including cost of all materials, all labour charges, lead, lift, etc. complete.
Plastering with cm 1:3, 12mm thick for ceiling, beams, sunshade,plinth etc. including cost of cement, all materials,curing, labour, lead and lift etc., complete.
Supplying, transporting fabrication, fixing Labour charges for fixing of appd quality of MS Rails (90 LBS) for transformer plinth in proper alignment and interconnections the Steelo rails with flat on both ends by welding including cost of rail, all materials labour charges, lead, lift etc. complete, as per standard specification
Supplying and spreading 75mm thick of 20mm metal over crusher dust of 100 thick including cost of labour for spreading lead, lift, etc. complete.
Supplying and fixing readymade earth collars of size 75 cm dia with 60 cm height and shell thickness of 50 mm with cover slab including cost of all materials, transport to site, labour, lead, lift, etc., complete as per standard specification.
Refilling the foundation pits of towers after stub setting and concreting with excavated earth other than sand in layers of 150mm thick, including charges for spreading watering, consolidation as per standard speclification and as directed by the Engineer at site including all labour charges lead and lifts etc., complete.
Manufacturing & supplying of RCC strut for fencing post of size 0.15 x0.15x3.4 M and transporting up to the location including cost of all materials lead lift etc complete
Manufacturing & supplying of RCC main fencing post of size 0.15 x0.15x3.70 M including .61m in the concrete area and top slanding portion of 0.65m and transporting & fixing in the location including cost of all materials lead lift etc complete
Supplying and fixing in position 300mm long eye bolts with nuts and washer for tying the barbed wire in corner post etc., including cost of all materials, lead, lift, labour charges etc., complete.
Supply and Fixing of Galvanised Chain link fence wire 10 SWG 50 x 50 mm with GI Flat 50x8mm at 6.00 m interval including transporting to the site.Quality and make to be approved by Department Engineer at site
Supplying and laying Labour charges for tying barbed wire 6 rows horizantally and sprial binding at 0.5m interval including straightening ,tying with GI binding wire , lead, lift,etc, complete as directed by department Engineer at site.
Fabricating, supplying and fixing of Main gate using structural steel angles, flats, plates, squares etc., as per specification and as directed and painting with two coats of approved colour enamel paint over one coat of red oxide primer including cost of steel and painting materials, lead, lift, labour, as per standard specification, etc., complete.
Colour washing with two coat of colour cement over over one coat of cement primer for exterior surface including cost of all materials, labour lead, lift brush etc., complete.
Supplying and fixing of colour coated roofing sheet of 0.50mm thick for D.G set room including all leads.lifts,labour etc complete
Fabrication ,Galvanising and supplying of tower parts as per bill of materials and as per specifiations at site including cost of all material, labour, lead, lift etc., complete
Labour charges for transport and erection of tower parts including tightining of bolt and nuts with washers ,final checking before loading the structures including labour, lead, lift etc., complete
Supplying of GI bolt and nuts,washers of various sizes conforming latest IS standards including cost of all material, labour, lead, lift etc., complete
Fabrication and supplying of Foundation bolt threading for a length of 15 cm at top and hot dip galvanising of bolt including supply of 3 nos of GI nuts and washers and fixing in the position as directed by the engineer at site including assembling of template etc., cost of template, all material, labour, lead, lift etc., complete
Assembling of template for lattice Structure including cost of template, transport charges all labour lead, lift, etc, complete.
Disposal of excavated earth including all leads and lifts etc complete
Supply and fixing of 100 mm dia "B" class GI pipe of approved quality and make as directed by the engineer at site including cost of all specials materials, transport, etc, complete
Supplying and fixing of GM gate valve of 100 mm dia of approved quality and make ,lead, lift,, etc. complete
Supply and fixing of 230 KV auto transformer expanded bellow including cost of all connected materials such as gaskete, bolts, nuts, etc., complete
Cable Duct and Road Works
Earth work excavation in hard gravelly soil. Stiff black cotton soil, hard red earth, shales, Murram, gravel, stoney earth mixed with small sized boulders etc., complete as per standard specification.
Providing and Laying , Spreading and compacting graded stone aggregates Wet mix MACADAM including premixing the material with the water At OMC in mechanical mixing plant carriage of mixed material by tipper to site laying of uniform layers with pavers in sub base / Base course on well prepared surface watering and compaction with power roller to achieve the desired dnsity including cost of material labour charges rentals for machinery fuel and all other incidental charges etc., complete as per clause 406 of MORTh rev 5 and as direeted by the TANTRANSCO engineer incharge at site.
Plain cement concrete M15 with minimum cement content not less than 240 kgs using 20mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
RCC in M25 with minimum cement content not less than 362 kgs using 12 to 20 mm HBG machine crushed metal for matt concrete with out form work including cost of cement, all materials labour, curing, all leads & lifts, vibrating charges, as per standard specification, etc., complete. ( but excluding cost of steel reinforcement)
RCC in M25 with minimum cement content not less than 362 kgs using 12 to 20 mm HBG machine crushed metal for cable duct wall with form work including cost of cement, all materials labour, curing, all leads & lifts, vibrating charges, including cost of centering, shutting, as per standard specification, etc., complete. ( but excluding cost of steel reinforcement)
RCC in M25 with minimum cement content not less than 362 kgs using 12 to 20 mm HBG machine crushed metal for cable duct wall with form work including cost of cement, all materials labour, curing, all leads & lifts, vibrating charges, including cost of centering, shutting, as per standard specification, etc., complete. ( but excluding cost of steel reinforcement)
Cable duct -cover slab
RCC M 25 with minimum cement content not less than 362 kgs mix using 12-20mm graded hard machine broken granite stone, including cost of all materials, form work, centering, curing, all labour charges, lead, lift, etc. complete. But excluding cost of steel reinforcement. For Culvert slab concrete 250 mm Tk.
Providing steel reinforcement MS/RTS rods up to 16 mm dia for reinforced concrete works, including cost of steel MS/RTS rods, binding wire, labour charges for cutting, straightening bending as per type design drawing, placing aligning, and tying properly with all leads and lift as per standard specification, etc., complete
Labour charges for transporting of all types of cable duct cover slab to working site to curing tank, curing tank to keeping them alignment in position including lead, lift etc., complete
Disposal of Excess of surplus earth away in low lying area with a lead of 100 Mts including spreading and levelling labour, lead, lift as per standard specification, etc., complete.
Labour charges for cutting of insert plates to required length and fixing and keeping in cable duct including all leads,lifts, etc complete.
Providing expansion joint for road concrete as per specification in both direction using prevalid aspheltics pad 20 mm thick to full width and depth of 150mm thick plastering with CM 1:3, 20 mm thick including cost of cement, all materials, labour, curing, all leads, and lifts, etc., complete.as per standard specification.
Supply of GI Angle & Insert plate
Providing and laying 50mm consolidated thick Bituminous macadam using 0.20 Cum of 26.50-13.20mm, 0.43 Cu.m of 13.20- 2.36mm and 0.08 Cum of 2.36mm & below size IRC metal with 37 Kgs of VG30/VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and consolidated by 8 - 10 tonne vibratory/Pnematic roller to the required density etc., including labour charges for attending to paver to site etc., including hire charges and fuel charges for 20-30 ton CMP with bitumen boiler, tipper trucks, 9m paver finisher, vibratory/pnematic rollers and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using central hot mix plant clause 504 of MORTH Rev-5.
Providing and laying Premix Carpet with seal coat Type-A to 20mm thick using 0.18 cum of 13.20mm, 0.09 cum of 11.20mm and 0.09cum of 6.70mm with 24.40 kgs of VG30 bitumen for premixing per 10sqm including cost and conveyance of all materials to site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in hot mix plant 20-30 ton capacity conveying the mixer to work site spreading the mix to uniform thickness of 50mm with the specified grades and cross sections and consolidated by Vibratory/Pneumatic roller of 8-10 tonne power roller to the required density etc. including labour , including hire charges and fuel charges hot mix plant with bitumen boiler, , Vibratory/Pneumatic rollers and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using central hot mix plant clause 505 of MORTH Rev-5
230KV Bay Extension Work at Anaikadavu for 230KV Kongalnagaram Feeder
Earth work excavation in hard stiff clay, stiff black cotton hard red earth,shales, muram, gravel, stoney earth and earth mixed with small size boulders in all soils with an initial lead, lift, etc., complete.
Earthwork excavation in MR and DMR not requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in hard rock requiring blasting.with an initial lead of 10m and lift of 2m etc complete.
Earthwork excavation in hard rock by wedging & Chiselling .with an initial lead of 10m and lift of 2m etc complete.
Plain cement concrete M15 with min.cement content not less than 240 kgs using 12 to 20mm HBG metal for foundation without formwork including cost of cement, all materials, labour, lead, lift, etc. complete.
RCC M 25 mix with minimum cement content not less than 362 kgs, using 12-20mm graded hard machine broken granite stone without formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for raft concrete ( excluding cost of steel reinforcement.)-matt Concrete
RCC M 25 with minimum cement content not less than 362 kgs, using 12-20mm graded hard machine broken granite stone with formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for Pedestal and other concretes ( excluding cost of steel reinforcement.)
RCC M 25 with minimum cement content not less than 362 kgs using 12-20mm graded hard machine broken granite stone with formwork including cost of all materials, curing, all labour charges, lead, lift, etc. complete.for Cable duct Cover slab concretes ( excluding cost of steel reinforcement.)
Providing steel reinforcement for RCC works including cost of steel rod binding wire and placing in postion of the steel reinforcement all materials, lead and lift etc., complete.
Providing casing pipe line for laying cable to breaker plinths with 110 mm dia PVC pipe 6 kg/cm2 including all specials and cost of all material, lead, lift, etc., complete as per standard specification.
Brick work in CM 1:5 using II class chamber burnt bricks for basement & superstructure including cost of all materials, all labour lead lift etc ., complete. super structure, including cost of all materials, all labour charges, lead, lift, etc. complete.
Plastering with cm 1:3, 12mm thick for ceiling, beams, sunshade,plinth etc. including cost of cement, all materials,curing, labour, lead and lift etc., complete.
Supplying and spreading 100mm thick of 20mm metal over crusher dust of 100 thick including cost of labour for spreading lead, lift, etc. complete.
Supplying and fixing readymade earth collars of size 75 cm dia with 60 cm height and shell thickness of 50 mm with cover slab including cost of all materials, transport to site, labour, lead, lift, etc., complete as per standard specification.
Supply and Fixing of Galvanised Chain link fence wire 10 SWG 50 x 50 mm with GI Flat 50x8mm at 6.00 m interval including gate ,transporting to the site.Quality and make to be approved by Department Engineer at site
Colour washing with two coat of colour cement over over one coat of cement primer for exterior surface including cost of all materials, labour lead, lift brush etc., complete.
Fabrication ,Galvanising and supplying of tower parts as per bill of materials and as per specifiations at site including cost of all material, labour, lead, lift etc., complete
Supplying of GI bolt and nuts,washers of various sizes conforming latest IS standards including cost of all material, labour, lead, lift etc., complete
Labour charges for transport and erection of tower parts including tightining of bolt and nuts with washers ,final checking before loading the structures including labour, lead, lift etc., complete
Fabrication and supplying of Foundation bolt threading for a length of 15 cm at top and hot dip galvanising of bolt including supply of 3 nos of GI nuts and washers and fixing in the position as directed by the engineer at site including assembling of template etc., cost of template, all material, labour, lead, lift etc., complete
Assembling of template for lattice Structure including cost of template, transport charges all labour lead, lift, etc, complete.
Refilling the foundation with excavated earth including spreading and levelling labour, lead, lift as per standard specification, etc., complete.
Disposal of Excess of surplus earth away in low lying area with a lead of 100 Mts including spreading and levelling labour, lead, lift as per standard specification, etc., complete.
Labour charges for cutting of insert plates to required length and fixing and keeping in cable duct including all leads,lifts, etc complete.
supplying of GI insert plate of size including all leads and lifts etc complete
Providing and laying PVC high density 10 ksc pipe including cost of all materials, labour, etc., complete.
32 MM DIA PVC PIPE
20 MM DIA PVC PIPE
Supplying and fixing in position of gun metal gate valve leader make of best quality including cost of materials lead lift labour etc complete.as directed by department Engineer at site
32 MM DIA
20MM DIA
Providing and fixing of long body chromium plated heavy duty metal tap of 12mm size including cost of all materials, labour, etc., complete.
Labour charges for transporting of all types of cable duct cover slab to working site to curing tank, curing tank to keeping them alignment in position including lead, lift etc., complete
Description of Work / Item(s)
Amount
Transformers
Supply of 230/110 KV, 160 MVA, 3 Phase, 50 HZ, YNaO, Outdoor Auto Transformer and all accessories, with Terminal Connectors and with Neutral CT for enabling REF Protection and OLTC with RTCC panel and must be compatible with the SAS and NIFPS (Nitrogen Injection Fire Protection System with Spares (Spare Nitrogen Cylinder - 1 No, Heat sensor for Fire detectors - 3 Nos, Regulator Assembly-1 No)
Supply of Station Transformer, 200 KVA, 22 KV/433 V Station Transformer with 22 KV HG Fuse Sets, 22 KV LAs - 6 Nos, Structure materials complete Set, 4 Way FRP Pillar Box, 22 KV (1250 A) Isolators 5 Nos with 22 KV Outdoor PT - 2 Nos (2 Core) with junction Box for Terminal connection, Insulators, all Consumables, Cables and all accessories for Station Transformer
Supply of 250 KVA DG Set Complete Set with all accessories and Protections Outdoor type, Protection Relay Panel, Extension of Exhaust Pipe with suitable size and quality MS Pipe upto Building outside through Silencer and properly insulating with suitable thermal insulating materials, Plinth concreting, Erection of AMF Panel with Battery Set, Control and Power Cable laying including all Consumables and commissioning and DG Room at First Floor Level, Steps leading to DG Set provided with Hand Rails.
Equipments
Supply of 245 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Supply of 145 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Supply of 245 KV, 2000 A, 5 Core, Single Phase Outdoor Current Transformer with Support Structure, T.C and all accesssories (1 No Junction Box for 3 CTs) (Ratio: 2000 - 1200 - 800 - 400/1 A, 0.2s & PS)
Supply of 145 KV, 2000 A, 5 Core, Single Phase Outdoor Current Transformer with Support Structure, T.C and all accesssories (1 No Junction Box for 3 CTs) (Ratio: 2000 - 1200 - 800 - 400/1A, 0.2s & PS)
Supply of 230 KV, 3 Core, Single Phase, Outdoor Line Voltage Transformers (LVT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 LVTs) (Ratio: 230KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Supply of 230 KV, 3 Core, Single Phase, Outdoor Potential Transformers (PT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 PTs) (Ratio: 230KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Supply of 110 KV, 3 Core, Single Phase, Outdoor Line Voltage Transformers (LVT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 LVTs) (Ratio: 110KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Supply of 110 KV, 3 Core, Single Phase, Outdoor Potential Transformers (PT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 PTs) (Ratio: 110KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Supply of 230 KV Lightning Arrester with Support Structure and all accessories
Supply of 110 KV Lightning Arrester with Support Structure and all accessories
Supply of 245 KV, 2000 A, Isolator with Earth Switch (Motor Operated) with Insulator, Support Structure, T.C and all accessories
Supply of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator, T.C, all accessories including Gear Arrangement and without Support Structure (Top Mounted By pass Switch)
Supply of 245 KV, 2000 A, Single Phase Bus Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 145 KV, 2000 A, Isolator with Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 145 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 145 KV, 2000 A, Single Phase Bus Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 245 KV Solid Core Insulators (Bus Post Insulator) with Support Structure and Terminal Connectors
Supply of 145 KV Solid Core Insulators (Bus Post Insulator) with Support Structure and Terminal Connectors
Battery, Battery Chargers & Power Room Accessories
Supply of 220 V, 300 Amphere Hour (AH) Battery (Transparent SAN Container) complete Set with Steel/Wooden Stand, Insulators and Terminal Connectors, Electrolyte, Hydrometer, Room Thermometer and Digital Multimeter
Supply of 220 V DC, 60 Amps Battery Charger with Potential Free Contacts for all indications for SAS Interface.
Supply of 48 V, 250 Ampere Hour (AH) Battery (Transparent SAN Container) complete Set with Teak Wooden Stand, Insulators and Terminal Connectors, Electrolyte, Hydrometer, Room Thermometer and Digital Multimeter
Supply of 48 V DC, 80 Amps Battery charger with Potential Free Contacts for all indications for SAS Interface.
Supply of AC Distribution Panel with Two incomer - As per Field Requirement (AC Under Voltage, Over Voltage Static Relays included)
Supply of 220 V DC Distribution Panel with DC Fail Alarm provision and as per Field Requirement (DC Under Voltage, Over Voltage Static Relays and DC E/F Relay included) with all necessary cablling for 220V DC charger 3 Nos and 220V DC battery 2 sets
Supply of 48V DC Distripution Panel with DC Fail Alarm provision and as per Field Requirement (DC Under Voltage, Over Voltage Static Relays and DC E/F Relay included) with all necessary cablling for 48 V DC charger 3 Nos and 48V DC battery 2 sets
400 A AC Change Over Switch
Supply of 60 A DC Change Over Switch with Bypass arrangement as per Field Requirement
Supply of 80 A DC Change Over Switch with Bypass arrangement as per Field Requirement
BMK - AC Junction Box (FRP) with MCBs as per Field Requirement
BMK - DC Interlock Box (FRP) with MCBs as per Field Requirement
BOQ OF CONTROL & PROTECTION PANELS WITH SAS
Control & protection panel for 230 kV Feeder (with BCU)
Control & protection panel for 230 kV Transfer Bus coupler Bay(with BCU)
230kv Bus bar protection panel (with 15 Circuits)
Control & protection panel for 230 kV/110kv Auto transformer (with BCU) - Both 230KV and 110KV side
Control & protection panel for 110 kV Feeder (with BCU)
Control & protection panel for 110 kV Bus coupler Bay (with BCU)
110KV Bus bar protection panel ( with 18 Circuits)
Synchronising cum Islanding Panel for 110KV Bays
Sub-Station Automation System (Total - 18 Nos Bays; 230KV Nays: 7 Nos and 110KV Bays: 11 Nos Bays) with Metering data concentrator for energy meter data acquisition and DR collection with remote accessibility system
Spares for Control & protection panels and for SAS
Supply of Scientific & Testing Instruments
Computerized Relay Testing Kit with Advanced Package and Latest Laptop (Omricon make CMC-356 essential Package + Advanced Distance + Differential + Advanced Transplay + GOOSE + OCC + OC IDMT & Dir Element Module + Transducer testing option + 3 Years warranty + Laptop + CMGPS588 + 400 PTL temPlates to test automatic testing + PTP Time Synch option + Transport casing - Rugged Hard Carry Case with Trolley.
Multi Function Transformer Testing Kit ( Omricon make CPC- 100 with CPTD12 + CT / VT / CVT + CP RC + Transformer Test Card + Switch Box for Automatic testing + Primary Injection up to 2000 A )
Circuit Breaker Analyzer Multi Break Kit with DCRM and Laptop Computer M/s.Omicron Make CIBINO 500 with all Accessories.
Fluke 87 V True RMS Industrial Multimeter with Tempreature.
10 KV Digital Insulation Tester (Rechargeble Battery operated) Megger Make S1-1068-10 KV with all Accessories.
Automatic Tan Delta Test Kit with variable Frequency
Handheld Digital True Rms AC/DC Currents upto 2000 A Clamp Meter ( Fluke 355 True RMS Clamp Meter 2000 A AC/DC )
Digital Mini Clamp Meter (for mA Current Measurement Range 3mA -30mA - 300mA - 3A, 30A, 60A ) Fluke 369/Megger DCM 305E with all Standard Accessories, Functions and Features enabled.
Digital Earth Resistance Clamp on Meter (Megger DET14C or equivalent advanced model)
Bit Error Meter (E1 Tester)
Ferruling Machine letawin LM550A/PC with all spares and standard accessories
Digital Level Meter (Electronika make ET-91)
Thermovision Camera (IR Cameras with the resolution of 640x480 pixels like FLIR Model T820 or equivalent Models with Laptop)
OTDR (Optical Time Domain Reflecto) Meter (Yokogawa Make AQ7285A Model with Power Meter & Light Source features enabled /Equivalent Model in EXFO make OTDR)
Optical Power Meter EXFO FPM 602/VIAVI OLP 35
Optical Laser Source Meter EXFO FLS 300 12D 23BL/VIAVI OLS 36
Optical Spilicing Equipment (Fujikura FSM 88S)
SF6 Gas Analyzer to measure dew Point Purity of SF6, SO2 (WIKA Model GA11 or EMT Model IR Zero waste SF6 Analyzer)
1 KV Digital Insulation Tester Megger MIT 320 with all standard accessories
Transformer Oil BDV Kit Megger OTS - 100AF
Current Transformer Analysing Kit (Omicron CT Analyser)
DC Earth Fault Locator Taurus make
Supply of Clamps & Connectors for Main Scheme
220/110 KV - Double Tension Fitting for Twin Zebra Conductor Space 225 mm with Turn Buckle - RDTS - 2
220/110 KV - Double Tension Fitting for Twin Zebra Conductor Space 225 mm with out Turn Buckle - RDTS - 2A
Corona Bell for 75mm Alu. Bus Bar - Clamp No: 74/94
Corona Bell for 50 mm Alu. Bus Bar
Free End Clamp for 75 mm Alu. Bus Bar
Seating Block for 75mm Alu. Bus Bar
PG Clamp for Zebra Conductor
Reducer Clamp for 75mm Alu. Bus to Twin Zebra
230 KV Rigid Type Spacer Clamp to suit Twin Zebra ACSR at 225 mm Spacing Clamp No: 73
110 KV Rigid Type Spacer Clamp to suit Twin Zebra ACSR at 225 mm Spacing Clamp No: 93
T-Clamp for 75 mm Bus to Single Zebra (75SZ)
T-Clamp for 75 mm Bus to Twin Zebra (220 KV TEE Connector to suit 3" IPS Alu.Tube on Twin Zebra ACSR (VA) - Clamp No: 61)
T-Clamp for Single Zebra to Twin Zebra (220 KV TEE Connector to suit Single Zebra ACSR on Run to Twin Zebra ACSR on tap - Clamp No: 66)
132 KV TEE Connecter to suit Single Panther ACSR on Run to Twin Zebra ACSR on Tap - Clamp No: 86
C - Type Fired Boltless Wedge Connectors for Zebra to Zebra ACSR Conductor - Clamp No: WDG)
230 KV Connector on BPI Insulator to suit Twin Zebra ACSR (HA) - Clamp No : 20 RT
110 KV Connector on BPI Insulator to suit Twin Zebra ACSR (HA) - Clamp No : 30 RT
230 KV Terminal connector on Underhaung BPI Insulator to suit Twin Zebra ACSR through Type - Clamp No : 21 T
110 KV Terminal connector on Underhaung BPI Insulator to suit Twin Zebra ACSR through Type - Clamp No : 31 T
Welding Sleeves to suit 75mm Aluminium Bus Bar - 88.9 OD/ 73.66 ID - Clamp No: 75
Supply of Control and Power Cables with Glands, Tag and other Accessories
Armoured Copper Control Cable 2 CX 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 4 Sq.mm
Armoured Copper Control Cable 8 C X 2.5 Sq.mm
Armoured Copper Control Cable 8 C X 4 Sq.mm
Armoured Copper Control Cable 14 C X 2.5 Sq.mm
Armoured Copper Control Cable 20 C X 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 16 Sq.mm
Armoured Copper Cable 4 X 120 Sq.mm
Armoured Copper Cable 2 X 70 Sq.mm
Supply of ISI mark ST Gland 19 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 22 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 25 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 28 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 32 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 35 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 50 mm as per direction of the Field Engineer.
Supply of Lugs, Ferrules, Sleeves, Cable Tie, Insulation Tape and other accessories for providing Cable Core End Termination
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.600 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.450 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.300 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Earthing System
Supply of materials for Earth Pit of 115 mm dia to a depth of 6 m including cost of materials for Earth electrode using M.S.Rod 40 mm dia, M.S.Angle, Red Soil and Bentonite powder of 30 Kg and other sundries as per approved drawing . Identification Board of size 300 X 150 mm 14 SWG, GI Bolt, Nut & Washers as directed by the Field Engineer as per DRG No: TR/GCC/CBE/230-110-33-22-11-EP/044
Supply and providing of 600 mm mean Dia, 300 mm Height, 36 mm Thick Cement Coller for identification of Earth electrode location including 1 perimeter and 2 coats of Colour wash as directed by the Field Engineer
Supply of MS Flat 75 x 12 mm for Earth Mat and linking connections to Earth electrode - 136.65 MT
Supply of MS Flat 65 x 10 mm for Earth Raiser for all 230 KV Structures, 230 KV Equipments, 230 KV Auto Transformer, all Panels, Earth Spike Connection to Main Mat/Pit and LLM Structures
Supply of MS Flat 50 x 8 mm for Earth Raiser for all 110 KV Structures, 110 KV Equipments Terminal Towers, Fencing Poles and Yard Lights
Supply of Earth Spikes by using 40 mm M.S. Rod & GI Earth Pipe at a height of 3 m, MS Angle, Bolt, Nut with Washers (40 mm Dia, 3 m length)
Supply of Station Auxiliaries
Supply of 230 KV Solid Core Insulators for Main Scheme
Supply of 110 KV Solid Core Insulators for Main Scheme
Supply of 11 KV, 120 KN Antifog Strain Disc Insulators
Supply of 75 mm Dia Aluminium Bus Bar (IPS Tube)
Supply of 50 mm Dia Aluminium Bus Bar (IPS Tube)
Supply of ACSR Zebra Conductor (54/3.18 mm + 7/3.18 mm)
Supply of GI Checkered Plate 6 mm thick for Control Room Cable Duct Cover
Supply of Rubber Mat 2000 X 1000 X 10 mm
Supply of Trolley mounted adjustable Telescopic GI Ladder 12 metre Height (Motor Operated)
Supply of Aluminium Ladder 8 metre Length
Supply of Aluminium Ladder 4 metre Length
Supply of Discharge Rod 10 Feet, (SS Type) made up of Hard PVC, Copper Flats and 6 Sq.mm.Cable as per IS Standard & as directed by the Field Engineer
Supply of Earth Rod 10 Feet, (SS Type) made up of Hard PVC, Copper Flats and 6 Sq.mm.Cable as per IS Standard & as directed by the Field Engineer
Supply of First Aid Box
Supply of Gauntlets
Supply of Digital Clock for GPS Time calibration
Supply of Portable Emergency Lamp with Rechargeable Type as per IS Standard & as directed by the Field Engineer
Supply of Emergency Lamp wall mounted with Battery Back up
Supply of Flexible Copper Tape/Rope, Flexible braided Copper for interlinking Panel Earthing and for providing connectivity whereever necessary/any other purpose/on any sizes including the cost of Copper Lugs at both ends as directed by the Field Engineer
Supply of Illumination for Switch Yard, Light Mast Tower and GI Tubular Pole as per Specification and Design, including all Materials, AC JB, DBs and Consumables using LED Technology for arriving lux 30 for 230 KV DAIS SS
Supply of Yard Light Stepped Tubular Pole 8 m Length Double Bracket Pole with base Plate (400 x 400 x 10 mm) 114.30 mm OD, x 5.40 mm thick, 4500 mm Length, 88.90 mm OD, x 4.85 mm thick, 1750 mm Length, 76.10 mm OD, x 3.25 mm thick, 1750 mm including cost of LED Light, Double Pole MCB, Fittings, Junction Box and Painting in complete shape as per direction of Field Engineer and approved drawing.
Supply of Various size GI/MS Iron & Steel Items such as R.S.Joist, Channels, Angles, Plates, Flats etc., for mounting Channel of Control and Protection Panels, Cable Tray for OD CT, PT & LVT, CC Equipments, AC, DC, Battery Charger, Inverter, RTCC Panel Strucures, Boards, Platforms Equipments & Transformer, Fire Equipment Stands, Water & Fire Bucket Stands, Equipment Board, Bay Marking Boards, Earth Pit Name Plate Boards and Fabrication of all TemPlates .,including painting and others whatever as required by the Field Engineer.
Supply of Red Oxide Paint of reputed make including cost of Paint, Brush and consumables etc., for Painting of all Earth Raisers and MS Materials
Supply of Aluminium Paint including cost of Paint, Brush and consumables etc., wherever necessary
Supply of Anti Corrossive Black Paint of reputed make including cost of Paint, Brush and consumables etc., for Painting of all Joints in Earth Raiser connections and Earth Mat
Supply of Enamel Paint of reputed make of various colours for Colour coding Painting of Bottom of all Structures, Equipments and Name Boards as per Field Requirement
Supply of Reflector Sticker of reputed make for Colour coding of all Equipments and Structures and any other Details of Breakers, Panels, chargers and General Key Boards as required and as directed by Field Engineer,
Supply of LC/Key Board of size 3000 mm length, 1500 mm height made out of 75 X 25 mm Aluminium Frame embeded with 12 mm Prelaminated Wooden Particle Board using Screw on rear 2 Nos Plain Glass of 5 mm thick fixed with Metal Roller moving on Aluminium Channel should be provided on Front with Locking arrangements, Lock with Duplicate Keys. LG Glass piece should be fastened on the Glass Shutters for opening and closing Wall Clamp made out of 6 mm Plate should be provided on as per Drawing along with Hook for Keys with Token and as directed by the Field Engineer including cost of all Materials.
Supply of Fire Fighting Equipements
Supply of Mechanical Foam (AFFF) type Trolley mounted 45 or 50 litre capacity AFFF Fire Extinguishers with initial charge, complete with Hose & Air induction Nozzle and in general all accessories confirming to the latest issue of IS 13386 with ISI Certification mark
Supply of Mechanical Foam Portable type 9 litre capacity Fire Extinguishers with initial charge complete with Chromium plated GM Cap, high pressure Nylon braided discharge Hose with specially designed Foam designed Nozzle and in general all accessories strictly confirming to the latest issue of IS 10204 with ISI Certification mark
Supply of Dry Chemical Powder type Trolly mounted Cylindrical shape 25 kg capacity Fire Extinguisher with initial charge & complete with Rubber or braided Hose, Dry Powder with level Indicator and all accessories confirming to the latest issue of IS 10658 with ISI Certification mark
Supply of Dry Chemical Powder type Cylindrical shape 9 or 10 kg capacity Fire Extinguisher withl initial charge & complete with Rubber or braided Hose, Dry Powder with level Indicator and all accessories confirming to the latest issue of IS 2171 and 1 with ISI Certification mark
Supply of Dry Chemical Powder type Cylindrical shape 5 or 6 kg capacity Fire Extinguisher withl initial charge & complete with Rubber or braided Hose, Dry Powder with level Indicator and all accessories confirming to the latest issue of IS 2171 and 1 with ISI Certification mark
Supply of Fire Protection Alarm System for Control Room and Cable Gallery
Manufacturing and Supply of Fire Bucket of 10 litre capacity made out of 26 (0.46 mm) SWG M.S Sheet painted with white & Red Enamel Paint in side & out side respectively; Bottom of Bucket shall be 'U' shaped out side of the Bucket shall be written as Fire in English & Tamil in white Enamel Paint, including cost of all Materials.
Manufacturing and Supply of Sand Drum made out of Oil Drum of Size 580 mm dia and 420 mm height with Conical Cover made out of Tin Sheet provided with Handle including the cost of Barrel, Sand and Consumables as directed by the Field Engineer.
Supply of Fire Shed suitable to storing outdoor Fire Fighting Equipments near Auto Transformer and 230 KV Breakers
Supply of Fire Equipment Stand suitable to Battery Room
Supply of Fire fighting Equipments Display Boards and First Aid Safty Chart Boards as directed by the Field Engineer.
Supply of CCTV Cameras of reputed make with high resolutions (704 x 480) for Day and Night Monitoring of the entire Switch Yard Area of size 200 x 120 m with 2000 m, Necessary connecting Cables including One Number Digital Video Recorder of reputed make with multiple Port of 24 way with all accessories & Two Numbers LED TV of reputed make of size 42" for monitoring of CCTV Cameras with 15 Days Storage Capacity (As per VMS Specification).
LT Metering Box (Double Compartment)
3 Phase 50- 100 A Static Energy Meter, 0.2 Accuracy
DSLP (Direct Stroke Lightning Protection) for Control Room and Switch Yard
Supply of Solar Panels on top of Control room at Kongalnagaram 230kV AIS SS
Communication equipments
Hybrid type Optical Line Terminal Equipment/(FOTE ) (SDH,PDH & MPLS-TP) (each 1 No. for proposed Kongal Nagaram 230kV SS, Edayarpalayam 400kV SS and Anaikadavu 400kV SS )
8 command stand alone Digital Tele Protection Coupler( 8 Nos. for proposed Kongal nagaram 230kV SS & 2 Nos. each for Anaikadavu 400kV SS, Edayarpalayam 400kV SS, O.K Mandapam 230kV SS and Myvadi 230kV SS)
Hybrid EPAX (16S/16T) ( Analog, Digital & VOIP)
VOIP Telephones with CAT6 shielded Cable, Ethernet switches and other accessories (each 3 No. for proposed Kongal Nagarm 230kV SS, Anaikadavu 400kV SS, O.K Mandapam and Myvadi 230kV SS)
Analogue Telephone with 4pair Telephone Cable and necessary accessories (Each 3 nos for proposed Kongal Nagarm 230kV SS, Anaikadavu 400kV SS, O.K Mandapam and Myvadi 230kV SS)
supply of Standalone Rack Panel for accommodating 4 nos Fibre optic 1" Rack with 4x19" rack provision 2000X800X800 mm with mm Thichkness and necessary fibre entry provision.
Mandatory Spares and tools for Hybrid FOTE equipment as per specification
Mandatory Spares and tools for DTPC equipment as per specification
Wall mount FODP equipped for 48F for Kongal Nagaram 230Kv SS
Extension of 1 no. 230KV bay at Anikadavu 400KV AIS SS for 230KV Kongalnagaram Feeder
Supply of 245 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Supply of 245 KV, 2000 A, 5 Core, Single Phase Outdoor Current Transformer with Support Structure, T.C and all accesssories (1 No Junction Box for 3 CTs) (Ratio: 2000 - 1200 - 800 - 400/1 A, 0.2s & PS)
Supply of 230 KV, 3 Core, Single Phase, Outdoor Line Voltage Transformers (LVT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 LVTs) (Ratio: 230KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Supply of 230 KV Lightning Arrester with Support Structure and all accessories
Supply of 245 KV, 2000 A, Isolator with Earth Switch (Motor Operated) with Insulator, Support Structure, T.C and all accessories
Supply of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Supply of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator, T.C, all accessories including Gear Arrangement and without Support Structure (Top Mounted By pass Switch)
Supply of 245 KV Solid Core Insulators (Bus Post Insulator) with Support Structure and Terminal Connectors
Indoor Panels (With SAS)
230 KV Control & Protection Panel for 230 KV Feeder
BMK - AC Junction Box (FRP) with MCBs as per Field Requirement
BMK - DC Interlock Box (FRP) with MCBs as per Field Requirement
Communication Equipments
Supply, Erection, Testing and Commissioning of ADSS 48 Fibre Cable with HDPE Pipe from Terminal Towers to Control Room includung Splicing Charges and all accessories etc., at Anaikadavu 400/230-110 KV AIS SS for 230 KV Kongal Nagaram
Supply of Control and Power Cables with Glands, Tag and other Accessories
Armoured Copper Control Cable 2 CX 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 4 Sq.mm
Armoured Copper Control Cable 8 C X 2.5 Sq.mm
Armoured Copper Control Cable 8 C X 4 Sq.mm
Armoured Copper Control Cable 14 C X 2.5 Sq.mm
Armoured Copper Control Cable 20 C X 2.5 Sq.mm
Armoured Copper Control Cable 28 C X 2.5 Sq.mm
Armoured Copper Control Cable 4 C X 16 Sq.mm
Co - Axial Cable
Supply of ISI mark ST Gland 19 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 22 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 25 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 28 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 32 mm as per direction of the Field Engineer.
Supply of ISI mark ST Gland 35 mm as per direction of the Field Engineer.
Supply of Disconnecting Type terminal Blocks suitable for CT Circuits in Panels/ Box as required and as directed by the Field Engineer required size
Supply of Mounting channels (Rail) suitable for CBTM 5 terminal block in Panel/ Box as required and as directed by the Field Engineer
Supply & fixing of Nut type CBTM 5 Or equivalant Terminal Block in Pannel/Box as required and as directed by the Field Engineer
Supply of Lugs, Ferrules, Sleeves, Cable Tie, Insulation Tape for providing Cable Core End Termination
Supply of ISI mark Backlite HRC / Rewirable Fuse Holders 16 A of reputed make in Panels/junction Boxes for AC / DC / PT Circuits wherever required & as directed by the Field Engineer.
Supply of ISI mark HRC Fuse without Fuse holder 2/ 5/ 10 A of reputed make in Panels/junction Boxes for AC / DC / PT Circuits wherever required & as directed by the Field Engineer.
Supply of ISI mark Poecelain rewirable Fuse unit 16 A of reputed make in Panels/junction Boxes for AC Circuits wherever required & as directed by the Field Engineer.
Supply of ISI make MCB in panels/ Boxes of reputed make as directed by the field Engineer - 3 Pole 32 Amps
Supply of ISI make MCB in panels/ Boxes of reputed make as directed by the field Engineer - 3 Pole 63 Amps
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.600 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.450 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Supply of GI Ladder type Cable Tray 2.5 m Length, 0.300 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Earthing System
Supply of materials for Earth Pit of 115 mm dia to a depth of 6 m including cost of materials for Earth electrode using M.S.Rod 40 mm dia, M.S.Angle, Red Soil and Bentonite powder of 30 Kg and other sundries as per approved drawing . Identification Board of size 300 X 150 mm 14 SWG, GI Bolt, Nut & Washers as directed by the Field Engineer as per DRG No: TR/GCC/CBE/230-110-33-22-11-EP/044
Supply and providing of 600 mm mean Dia, 300 mm Height, 36 mm Thick Cement Coller for identification of Earth electrode location including 1 perimeter and 2 coats of Colour wash as directed by the Field Engineer
Supply of MS Round Rod 40 mm Dia for Earth Mat and linking connections to Earth electrode
Supply of MS Flat 75 x 12 mm for Earth Mat and linking connections to Earth electrode
Supply of MS Flat 65 x 10 mm for Earth Raiser for all 230 KV Structures, 230 KV Equipments, 230 KV Auto Transformer, all Panels, Earth Spike Connection to Main Mat/Pit and LLM Structures
Supply of MS Flat 50 x 8 mm for Earth Raiser for all 110 KV Structures, 110 KV Equipments Terminal Towers, Fencing Poles and Yard Lights
Supply of Earth Spikes by using 40 mm M.S. Rod & GI Earth Pipe at a height of 3 m, MS Angle, Bolt, Nut with Washers (40 mm Dia, 3 m length)
Supply and provision of M8, M9, M10, M12 & M16 full thread GI bolt, nuts & GI washer of various size for erection of insulator or any other purpose wherever required and as directed by the Field Engineer.
Supply of G.I. Earth wire 7/3.55mm as per latest IS Code 2062.
Fixing of Flexible Copper tape/rope for interlinking Panel Earthing and for any other purpose as directed by the Field Engineer
Supply of Clamps & Connectors for Main Scheme
Bolted type Double Tension fitting with double anchoring points, suitable for 230 KV Quadraple Moose 225 mm spacing - RTS - 10 (With Turn Buckle)
Bolted type Double Tension fitting with double anchoring points, suitable for 230 KV Quadraple Moose 225 mm spacing - RTS - 10A (Without Turn Buckle)
Bolted type Double Tension fitting with double anchoring points, suitable for 230 KV Twin Moose 225 mm spacing - RDTS - 2 (With Turn Buckle)
Bolted type Double Tension fitting with double anchoring points, suitable for 230 KV Twin Moose 225 mm spacing - RDTS - 2A (Without Turn Buckle)
230 KV Rigid Type Spacer Clamp to suit Quadraple moose ACSR at 225 mm spacing (Clamp No. 70)
230 KV T Connector for Single Zebra to Single Zebra
230 KV Rigid Type Spacer Clamp to suit Twin Zebra ACSR at 225 mm spacing (Clamp No. 73Z)
230 KV Rigid Type Spacer Clamp to suit Twin Moose ACSR at 225 mm spacing (Clamp No. 73M)
T-Clamp for Single Zebra to Twin Moose (220 KV TEE Connector to suit Single Zebra ACSR on Run to Twin Zebra ACSR on tap - Clamp No: 66)
230 KV T Connector to suit Twin Moose to Twin Moose ACSR (Clamp No. 64)
230 KV Terminal Connector on BPI to suit Twin Moose ACSR (HA) (Clamp No. 20RT)
230 KV Suspension Fitting to suit Twin Moose ACSR (2SSDT)
T-Clamp for 75 mm Bus to Twin Moose (220 KV TEE Connector to suit 3" IPS Alu.Tube on Twin Moose ACSR (VA) - Clamp No: 61)
230 KV T Connector to Suit Twin Moose to Single Moose ACSR (Clamp No. 65)
230 KV Connector on BPI to suit 3" Bus Through / Sliding Type (Clamp No. 2TS)
230 KV Corona Bell for to suit 3' Bus Bar
230 KV Terminal connector on Underhaung BPI Insulator to suit Twin Zebra ACSR through Type - Clamp No : 21 T
Welding Sleeves to suit 75mm Aluminium Bus Bar - 88.9 OD/ 73.66 ID - Clamp No: 75
Supply of 230 KV Solid Core Insulators for Main Scheme
Supply of 11 KV, 160 KN Antifog Strain Disc Insulators
Supply of 11 KV, 120 KN Antifog Strain Disc Insulators
Supply of 75 mm Dia Aluminium Bus Bar (IPS Tube) (15 Nos)
Supply of ACSR Moose Conductor
Supply of ACSR Zebra Conductor (54/3.18 mm + 7/3.18 mm)
Painting
Supply of Enamel Paint of reputed make of various colours for Colour coding Painting of Bottom of all Structures, Equipments and Name Boards as per Field Requirement
Supply of PVC Reflector Sticker of reputed make for Colour coding of all Equipments and Structures and any other Details of Breakers, Panels, chargers and General Key Boards as required and as directed by Field Engineer
Description of Work / Item(s)
Amount
Erection of Auto Transformer & Station Transformer
Erection, Testing & Commissioning of 230/110 KV, 160 MVA, 3 Phase, 50 HZ, YNaO, Outdoor Auto Transformer and all accessories, with Terminal Connectors and with Neutral CT for enabling REF Protection and OLTC with RTCC and must be compatible with the SAS and NIFPS
Erection, Testing and commissioning of 250 KVA DG Set complete Set with all accessories and Protections Outdoor type, Protection Relay Panel, Extension of exhaust Pipe with suitable size and quality MS Pipe upto building outside through silencer and properly insulating with suitable thermal insulating Materials, Plinth concreting, Erection of AMF Panel with Battery Set, Control and Power Cable laying including all Consumables and Commissioning and DG Room at First Floor Level, Steps leading to DG Set provided with Hand Rails.
Erection of Station Transformer, 200 KVA, 22 KV/433 V Station Transformer with 22 KV HG Fuse Sets, 22 KV LAs - 6 Nos, Structure Materials complete Set, 2 Nos 4 Way FRP Pillar Box, 22 KV Isolators 2 Nos with 22 kV Outdoor PT - 2 Nos (2 Core) with junction Box for Terminal connection, Insulators, all Consumables, Cables and all accessories for Station Transformer
Erection of Equipments
Erection of 245 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Erection of 145 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Erection of 245 KV, 2000 A, 5 Core, Single Phase Current Transformer with Support Structure, JB and all accesssories (1 No Junction Box for 3 CTs)
Erection of 110 KV, 2000 A, 5 Core, Single Phase Current Transformer with Support Structure, JB and all accesssories (1 No Junction Box for 3 CTs)
Erection of 230 KV Outdoor 3 Core, Single Phase Line Voltage Transformers (LVT), 0.2 & PS, 230KV/√3 / 110V/√3-110V/√3-110V/√3 with Support Structure, JB and all accessories (1 No Junction Box for 3 LVTs)
Erection of 230 KV Outdoor 3 Core, Single Phase Potential Transformers (PT), 0.2 & PS, 230KV/√3 / 110V/√3-110V/√3-110V/√3 with Support Structure, JB and all accessories (1 No Junction Box for 3 PTs)
Erection of 110 KV Outdoor 3 Core, Single Phase Line Voltage Transformers (LVT), 0.2 & PS, 230KV/√3 / 110V/√3-110V/√3-110V/√3 with Support Structure, JB and all accessories (1 No Junction Box for 3 LVTs)
Erection of 110 KV Outdoor 3 Core, Single Phase Potential Transformers (PT), 0.2 & PS, 230KV/√3 / 110V/√3-110V/√3-110V/√3 with Support Structure, JB and all accessories (1 No Junction Box for 3 PTs)
Erection of 230 KV Lightning Arrester with Support Structure
Erection of 110 KV Lightning arrester with Support Structure
Erection of 245 KV, 2000 A, Isolator with Earth Switch (Motor operated) with Insulator and Support Structure.
Erection of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator and Support Structure.
Erection of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) Insulator, with out Support Structure (Top Mounted By pass Switch) including Gear Arrangement
Erection of 245 KV, 2000 A, Single Phase Bus Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Erection of 145 KV, 2000 A, Isolator with Earth Switch (Motor operated) with Insulator and Support Structure Motor operated
Erection of 145 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator and Support Structure motor operated
Erection of 145 KV, 2000 A, Single Phase Bus Earth Switch (Motor operated) with Insulator, Support Structure, T.C and all accessories
Erection of 230 KV Bus Post Insulator with Support Structure with 230 KV Solid Core Insulators
Erection of 110 KV Bus Post Insulator with Support Structure with 110 KV Solid Core Insulators
Erection of Battery, Battery Chargers & Power Room Accessories
Labour for Erection of 220 V, 300 Amphere Hour (AH) Battery (Transparent SAN Container) complete Set including two coats of painting of Acid proof paint on wooden stand and neatly stacking the Battery Cells and fixing of connecting Plates.
Labour, Consumables for the Initial filling and First charging of the 220 V, 300 Amphere Hour (AH) Battery (Transparent SAN Container) complete Set to the required mAH input and there after atleast 3 cycles of Charge/Discharge of the Battery Set till the Battery is charged to its full capacity as directed by the Field Engineer along with Tools for charging of Battery
Erection of 220 V DC, 60 Amps Battery Charger with Potential Free Contacts for all indications for SAS Interface.
Labour for Erection of 48 V, 250 Amphere Hour (AH) Battery (Transparent SAN Container) complete Set including two coats of painting of Acid proof paint on wooden stand and neatly stacking the battery cells and fixing of connecting Plates.
Labour, Consumables for the Initial filling and First charging of the 48 V, 250 Amphere Hour (AH) Battery (Transparent SAN Container) complete Set to the required mAH input and there after atleast 3 cycles of Charge/Discharge of the Battery Set till the Battery is charged to its full capacity as directed by the Field Engineer along with Tools for charging of Battery
Erection of 48 V, DC, 80 Amps Battery charger with Potential Free Contacts for all indications for SAS Interface.
Erection of 220 V DC Distribution Panel with DC Fail Alarm provision and as per Field Requirement (DC Under Voltage, Over Voltage Static Relays and DC E/F Relay included) with necessary cabling between battery and battery charger
Erection of 48 V DC Distribution Panel with DC Fail Alarm provision and as per Field Requirement (DC Under Voltage, Over Voltage Static Relays and DC E/F Relay included) with necessary cabling between battery and battery charger
Erection of AC Distribution Panel with Two incomer - As per Field Requirement (AC Under Voltage, Over Voltage Static Relays included)
Erection of 400 A AC Change Over Switch
Erection of 60 A DC Change Over Switch with Bypass arrangement as per Field Requirement
Erection of 80 A DC Change Over Switch with Bypass arrangement as per Field Requirement
Erection of CRP and SAS Panels
Labour for erection of aII Simplex Indoor/Outdoor Panels/ ACJB (FRP), DCIB (FRP) including Supply & Fabrication of MS Flat 65 X 10 mm for mounting arrangement and earthing of Panel including Hardwares etc.,
Control & protection panel for 230 kV Feeder (with BCU)
Control & protection panel for 230 kV Transfer Bus coupler Bay(with BCU)
230kv Bus bar protection panel (with 15 Circuits)
Control & protection panel for 230 kV/110kv Auto transformer (with BCU) - Both 230KV and 110KV side
Control & protection panel for 110 kV Feeder (with BCU)
Control & protection panel for 110 kV Bus coupler Bay (with BCU)
110KV Bus bar protection panel ( with 18 Circuits)
Synchronising cum Islanding Panel for 110KV Bays
Sub-Station Automation System (Total - 18 Nos Bays; 230KV Nays: 7 Nos and 110KV Bays: 11 Nos Bays) with Metering data concentrator for energy meter data acquisition and DR collection with remote accessibility system
Erection of Control and Power Cables with Glands, Tag and other Accessories
Labour for erection of Cable in Duct/Trench - Neat laying in the ducts with Identification Aluminium tags in all duct corners for easy Identification of Cables, including fabrication of Clamps and fixing at uniform intervals as directed by the Field Engineer - Upto 8 Core
Labour for erection of Cable in Duct/Trench - Neat laying in the ducts with Identification Aluminium tags in all duct corners for easy Identification of Cables, including fabrication of Clamps and fixing at uniform intervals as directed by the Field Engineer - Above 8 Core
Labour for laying of Cable up to 8 Core & Clamping on Structure inluding neat dressing with Identification Aluminium tags etc.,
Labour for laying of Cable above 8 core & Clamping on Structure including neat dressing with Identification Aluminium tags etc.,
Labour for erection 19 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 22 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 25 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 28 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 32 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 35 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 50 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour Charges for Cable Core End Termination.
Erection of GI Ladder type Cable Tray 2.5 m Length, 0.600 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Erection of GI Ladder type Cable Tray 2.5 m Length, 0.450 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Erection of GI Ladder type Cable Tray 2.5 m Length, 0.300 m Width and 2 mm thickness with coupling Plate and Bolt Nuts
Erection of Earthing System
Providing Earth Pit of 115 mm dia to a depth of 6 m, labour for fabrication of Earth Electrode using M.S.Rod 40 mm dia & insert Electrode in to the bore and refilling with Red Soil and Bentonite Powder of 30 Kg and other sundries. Identification Board of size 300 X 150 mm 14 SWG. lettering and 12 mm M.S.Round Rod to be fixed in the Board and Anti Corrocive black Paint should be Painted top of the Earth Rod & its holding portion as directed by the Field Engineer as per DRG No: TR/GCC/CBE/ 230-110-33-22-11-EP/044
Labour Machineries, Consumables for erection of Earth Mat & Earth Raisers. (Electricity Supply will be brone by Department)
Labour for excavation & refilling of trunch of avg.width of 0.3 m & avg depth of 0.8 m for earth mat below fixed yard level
Labour, Machineries, Consumables for Earth Raisers for Equipments and Structures. (Electricity Supply will be brone by Department)
Labour Machineries, Consumables for fabrication & erection of Earth Spikes without Materials including sharpening of Top portion & Galvanising, welding & Clipping the Earthwire to Earthmat/EarthPit
Erection of Strung Bus & Bus arrangements
Erection of 230 KV Strung Bus Labour for Strining of Strung Bus including Hoisting of Iron, Insulator and erection of Eye Bolt and Hardware Fittings (1 Span, 6 Run)
Erection of 110 KV Strung Bus Labour for Strining of Strung Bus including Hoisting of Iron, Insulator and erection of Eye Bolt and Hardware Fittings (1 Span, 6 Run)
Labour for Erection of 75 mm IPS Aluminium Tube Bus Bar with out making bends with appropriate machineries and consumables
Labour for Erection of 50 mm IPS Aluminium Tube Bus Bar with out making bends with appropriate machineries and consumables
Labour for providing Droppers and Jumpers Up to Height of 6m
Labour for providing Droppers and Jumpers Up to Height of 6 m to 10 m
Labour for providing Droppers and Jumpers above a Height of 10 m
Labour for Erection of 230 KV Insulators Double Pole Stack Under Hang or Suspension
Labour for Erection of 110 KV Insulators Single Pole Stack Under Hang or Suspension
Erection of Station Accessories
Erection of Rubber Mat 2000 x 1000 x 10 mm
Erection of GI Checkered Plate 6 mm thick for Control Room Cable Duct Cover including Cutting labour
Erection of Flexible Copper Tape/Rope, Flexible braided Copper for interlinking Panel Earthing and for providing connectivity whereever necessary/other purpose as directed by the Field Engineer
Erection, Testing of Illumination for Switch Yard, Light Master Tower and Tubular Pole as per Specification and Design including all Materials, AC JB, DBs and Consumables using LED Technology for arriving lux 30
Erection of Double Fitting LED Pole 6 & 8 metre and Laying of Cable inside the Pole including testing for burning condition.
Labour for erection of Yard Light Box including fabrication of Clamping arrangements
Labour, Machineries, Consumables for Fabrication of Light Section with joints wherever necessary (Sectional Weight below 14 Kg /m)
Labour for the Erection of the Fabricated Steel Structures Heavy section (below 14 kg/m )
Labour charges for One Primary coat of Red Oxide Painting of various Structures after proper surface preparation using approppriate Machinery to remove Rust/Scales etc.,
Labour charges for Two coat of Aluminium Painting of various Structures after proper surface preparation using approppriate Machinery to remove Rust/Scales etc.,
Labour charges for One coat Enamal Painting / Anti Corrosive Painting of chequrred plates, Equipment Board, Identification of Earth Pit Board and Yard Light Pole, Structure Earthing, Earth Mat, Earth Pit, shoe Paint of Iron & Steel items after proper surface preparation using approppriate Machinery to remove Rust/Scales etc., as directed by the Field Engineer.
Labour Only for Painting of Second Finish Coat of all Sections
Fixing of Reflector Sticker of reputed make for Colour coding of all Equipments and Structures and any other Details of Breakers, Panels, chargers and General Key Boards as required and as directed by Field Engineer
Erection of Fire Fighting Equipements
50 Litre Trolley mounted Foam type Fire Extinguisher
9 Litre Portable Foam type Fire Extinguisher
25 Kg Trolley Mounted DCP Type Fire Extinguisher
9 OR 10 Kg DCP Type Fire Extinguisher
5 OR 6 Kg DCP Type Fire Extinguisher
Erection of Fire Protection Alarm System for Control Room and Cable Gallery
Erection of LC/Key Board of size 3000 mm, length 1500 mm height made out of 75 x 25 mm aluminium frame embeded with 12 mm prelaminated wooden Board removable with moving Glass Shutter of 5 mm thick, locking arrangements Lock with Duplicate Keys, Wall Clamps, Key Hooks and Drawing for Electrical Layout and details as directed by the Field Engineer including cost of all Materials.
Erection of CCTV Cameras of reputed make with high resolutions (704 x 480) for Day and Night Monitoring of the entire Switch yard area of size 200 x 90 m with 2000 m, Necessary connecting Cables including One Number Digital Video Recorder of reputed make with multiple Port of 24 way with all accessories & Two Numbers LED TV of reputed make of size 42" for monitoring of CCTV Cameras with 15 days Storage capacity (As per VMS Specification).
LT Metering Box (Double Compartment)
DSLP (Direct Stroke Lightning Protection) for Control room and Switch yard
Erection, testing & commissioning of Hybrid type Optical Line Terminal Equipment/(FOTE ) (SDH,PDH & MPLS-TP) (each 1 No. for proposed Kongal Nagaram 230kV SS, Edayarpalayam 400kV SS and Anaikadavu 400kV SS )
Erection, testing & commissioning of Digital Protection Coupler ( 8 Nos. for proposed Kongal nagaram 230kV SS & 2 Nos. each for Anaikadavu 400kV SS, Edayarpalayam 400kV SS, O.K Mandapam 230kV SS and Myvadi 230kV SS)
Erection, testing & commissioning of Hybrid EPAX along with VOIP/Analogue telephones and accessories
Wall mount FODP equipped for 48F for Kongal Nagaram 230Kv SS
Erection of Solar Panels on top of Control room at Kongalnagaram SS
Extension of 1 no. 230KV bay at Anaikadavu 400KV AIS SS for 230KV Kongalnagaram Feeder
Erection of 245 KV, 2000 A, Outdoor SF6 Breaker with all accessories and Support Structure
Erection of 245 KV, 2000 A, 5 Core, Single Phase Current Transformer with Support Structure, JB and all accesssories (1 No Junction Box for 3 CTs)
Erection of 230 KV, 3 Core, Single Phase, Outdoor Line Voltage Transformers (LVT) with Support Structure, T.C and all accesssories (1 No Junction Box for 3 LVTs) (Ratio: 230KV/√3 / 110V/√3-110V/√3-110V/√3, 0.2 & PS)
Erection of 230 KV Lightning Arrester with Support Structure
Erection of 245 KV, 2000 A, Isolator with Earth Switch (Motor operated) with Insulator and Support Structure.
Erection of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) with Insulator and Support Structure.
Erection of 245 KV, 2000 A, Isolator without Earth Switch (Motor operated) Insulator, with out Support Structure (Top Mounted By pass Switch) including Gear Arrangement
Erection of 230 KV Bus Post Insulator with Support Structure with 230 KV Solid Core Insulators
Erection, testing and commissioning of 230 KV Control & Protection Panel including SAS integration with existing NR make SAS for 230 KV Feeder at existing Anaikadavu 400 KV SS end.
Erection of BMK - AC Junction Box (FRP) with MCBs as per Field Requirement
Erection of BMK - DC Interlock Box (FRP) with MCBs as per Field Requirement
Earthing System
Providing Earth Pit of 115 mm dia to a depth of 6 m, labour for fabrication of Earth Electrode using M.S.Rod 40 mm dia & insert Electrode in to the bore and refilling with Red Soil and Bentonite Powder of 30 Kg and other sundries. Identification Board of size 300 X 150 mm 14 SWG. lettering and 12 mm M.S.Round Rod to be fixed in the Board and Anti Corrocive black Paint should be Painted top of the Earth Rod & its holding portion as directed by the Field Engineer as per DRG No: TR/GCC/CBE/ 230-110-33-22-11-EP/044
Labour Machineries, Consumables for erection of Earth Mat & Earth Raisers. (Electricity Supply will be brone by Department)
Labour for excavation & refilling of trunch of avg.width of 0.3 m & avg depth of 0.8 m for earth mat below fixed yard level
Labour, Machineries, Consumables for Earth Raisers for Equipments and Structures. (Electricity Supply will be brone by Department)
Labour Machineries, Consumables for fabrication & erection of Earth Spikes without Materials including sharpening of Top portion & Galvanising, welding & Clipping the Earthwire to Earthmat/EarthPit
Substation Auxiliary works.
Erection of 230 KV strung Bus using Quadraple Moose Conductor, fixing Bolted type Tension fitting with Corona Ring, (adjustable plate & spring on one side & fixed on another side), yoke plate (Top - adjustable, Bottom - fixed), double anchRing with fittings & accessories with 2 X 13 Disc Insulators & Spacer (1 Span of 3 Runs) (Note:- 20 % Extra Rate for LC Work for Labour only)
Erection of 230 KV strung Bus using Twin Moose Conductor, fixing Bolted type Tension fitting with Corona Ring, (adjustable plate & spRing on one side & fixed on another side), yoke plate (Top - adjustable, Bottom - fixed), double anchoRing with fittings & accessories with 2 X 13 Disc Insulators & Spacer (1 Span of 3 Runs)
Labour for Erection of 75 mm IPS Aluminium Tube Bus Bar with out making bends with appropriate machineries and consumables (Note:- 20 % Extra Rate for LC Work for Labour only)
Labour for Erection of 75 mm IPS Aluminium Tube Bus Bar with out making bends with appropriate machineries and consumables
Labour for Dismantling Droppers and Jumpers Up to height of 6 m to 10 m (Note:- 20 % Extra Rate for LC Work for Labour only)
Labour for providing Droppers and Jumpers Up to height of 6m
Labour for providing Droppers and Jumpers Up to height of 6m to 10 m
Labour for Providing Droppers and Jumpers Up to height of 6m to 10 m (Note:- 20 % Extra Rate for LC Work for Labour only)
Labour for providing Droppers and Jumpers above 10 m from Ground Level
Fixing of Flexible Copper tape/rope for interlinking Panel Earthing and for any other purpose as directed by the Field Engineer
Cable Laying & Wiring Works
Labour for erection of Cable in Duct/Trench - Neat laying in the ducts with Identification Aluminium tags in all duct corners for easy Identification of Cables, including fabrication of Clamps and fixing at uniform intervals as directed by the Field Engineer - Upto 8 Core
Labour for erection of Cable in Duct/Trench - Neat laying in the ducts with Identification Aluminium tags in all duct corners for easy Identification of Cables, including fabrication of Clamps and fixing at uniform intervals as directed by the Field Engineer - Above 8 Core
Labour for laying of Cable up to 8 Core & Clamping on Structure inluding neat dressing with Identification Aluminium tags etc.,
Labour for laying of Cable above 8 core & Clamping on Structure including neat dressing with Identification Aluminium tags etc.,
Labour for excavation & refilling of trunch of avg.width of 0.3 m & avg depth of 0.4 m for laying of Control Cable/ Yard light Cable below fixed yard level
Labour for erection 19/22 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 25 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 28 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 32 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Labour for erection 35 mm Cable Glands by providing required No of holes in the Gland plate/ Panels and mechanism/ Control cubical, removing the Cable sheeths, cutting of armour to the required length and makingup the Cable with Gland and fixing the Cable with Gland in the required location.
Fixing of terminal block /disconnected type terminal block as required and directed by the Field Engineer
Labour Charges for Cable Core End Termination.
Fixing of all types of MCB, Fuse holder and Fuse of all range wherever required as directed by the field Engineer.
Painting
Labour charges for One coat Enamal Painting / Anti Corrosive Painting of chequrred plates, Equipment Board, Identification of Earth Pit Board and Yard Light Pole, Structure Earthing, Earth Mat, Earth Pit, shoe Paint of Iron & Steel items after proper surface preparation using approppriate Machinery to remove Rust/Scales etc., as directed by the Field Engineer.
Labour Only for Painting of Second Finish Coat of all Sections
Labour charges for writing details in Finished Surface Boards including cost of Enamel Paint (Dulex, Asian, Berger preferred) and other Consumables as directed by the Field Engineer.
Fixing of Reflector Sticker of reputed make for Colour coding of all Equipments and Structures and any other Details of Breakers, Panels, chargers and General Key Boards as required and as directed by Field Engineer,
ESHS Cost Schedule for Total Tendered Work
Resources allocated to ESHS management
Drafting and updating the ESHS documentation, reporting, inspections
Implementation of the Health and Safety Plan: Meetings, health care centre, medical check ups, emergencies and evacuations, safety protective equipment, hygiene
Accommodation, drinking water, meals and transportation of staff(*) (*) : The Bidder shall detail the financial conditions of the supply of accommodation, meals and transport to its staff: Accommodation Meals Transport
Training and local recruitment management costs
Protection of adjacent areas, biodiversity,prevention of erosion and wastewater management
Traffic, noise and atmospheric emissions management, land take
Waste and hazardous products management
Vegetation clearing and site rehabilitation
UNIVERSAL CABLES LIMITED (BID ID -1405420)
UNIVERSAL CABLES LIMITED (BID ID -1405420)
UNIVERSAL CABLES LIMITED (BID ID -1405420)
UNIVERSAL CABLES LIMITED (BID ID -1405420)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid