Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹29.6 LAdmitted-Finance GSTIN: 09BXKPA5804N1Z6 | -15.00% | ₹29.6 L | L1 | Admitted-Finance |
| 2 | L2₹30.1 LAdmitted-Finance GSTIN: 06AFBPA9508H1ZR, 08AIQPG8212J1ZZLIG FLATS 29 B RAMPURA DELHI NORTH WEST DELHI DELHI 110035 UDYAM DL 11 0082911 | NORTH WEST DELHI | DELHI | 110035 | -13.56% | ₹30.1 L | L2 | Admitted-Finance |
Tender Value
₹34.8 L
EMD Value
₹69,560
Closing Date
30 Apr 2026, 4:00 pmClosed
Executive Engineer (BM-PK)
Room No.1615, 16th Floor, Palika Kendra, New Delhi.
Repair of Existing Balconies Treatment, rain water pipe and allied Civil items at NDCC-II building YMCA side.
2026_NDMC_290196_1
NIT No.01/EE (BM-PK)/2026-27
Open Tender
Civil Works
45 days
NDMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹69,560
12 May 2026
22 Apr 2026
30 Apr 2026
22 Apr 2026
30 Apr 2026
22 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) | |||||
| 2Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness | |||||
| 3Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter | |||||
| 4Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (1) Single tee with Door 110x110X110 mm | |||||
| 4.2 | Single without Door110x110X110 mm | - | Each | - | - |
| 4.3 | Bend 87.5 110mm bend | - | Each | - | - |
| 5Providing and applying waterproofing treatment to sound, moisture free concrete surface using liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks up to 2mm. It shall be applied in two coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. the membrane formed shall confirm to following minimum properties : 1. Elongation : 400% as per ASTM D 412 2. Tensile Strength : 2.5N/mm 2 as per ASTM D 412 3. Adhesion in –peel test : 50 N as per ASTM C-836 4. Recovery from 350% elongation : 95% as per ASTM D 412 5. Water Vapor Transmission 2.3mm film : 0.6 g/m2/hr 6. Initial Hardness Shore A : min 60 as per ASTM D 2240 7. Root resistant : Protection screed required System included supply, application and termination of coating all complete as per the manufacturer methodology. Clean the RCC slab/screed surface & wall for treatment by removing dust, dirt and layers of concrete over the surface etc. by mechanical tools and wire brushing. Pressure grouting at construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufactures’ recommendations. Providing and apply in liquid applied single component pitch free polyurethane coating in 2 coats at coverage rate of 2kg/sqm to a achieve a minimum DFT of 1.3 mm. (Fiber cloth…./reinforcement should not be used in between two coats of PU as it has adverse effect on elongation property and also affects bonding with slab). Termination shall be done 300 mm above vertical wall by providing groove cut of 30mm x 30mm & seal it with shrinkage compensated polymer modified mortar. Membrane shall be protected using 8mm thick dimple board for protection as per manufacture’s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology excluding the cost of protection board. | |||||
| 6Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) | |||||
| 7Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. | |||||
| 8Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.40 MB
BOQ_385233.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid