| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC PULWAMA JAMMU KASHMIR 192301 INDIA | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.8 L+₹13,350 (0.56%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | Rejected-Technical 205 KRISHNA NAGAR GOLA KA MANDIR NEAR AIRTEL TOWER NO 01 MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | - | Rejected-Technical Criteria not fulfilled as per NIT. |
| Sl No | Description | Qty | Unit | DUGGAL CONSTRUCTION CO L2 | Peerzada And Sons L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed. | 220 | Cum | 80 ₹17,600 Lowest | 300 ₹66,000 |
| 2.00 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed. | 198 | Cum | 20 ₹3,960 Lowest | 150 ₹29,700 |
| 3.00 | Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 22 | Cum | 20 ₹440 Lowest | 250 ₹5,500 |
| 4.00Taking down GI pipe line from trench/wall/floor/roof stacking it reuse or issued to contrctroctor as credit of following sizes | |||||
| 4.01 | GI pipe of 15mm bore | 100 | RM | 10 ₹1,000 Lowest | 10 ₹1,000 Lowest |
| 4.02 | GI pipe of 20mm bore | 150 | RM | 10 ₹1,500 Lowest | 15 ₹2,250 |
| 4.03 | GI pipe of 25mm bore | 150 | RM | 10 ₹1,500 Lowest | 15 ₹2,250 |
| 4.04 | GI pipe of 40mm bore | 200 | RM | 10 ₹2,000 Lowest | 20 ₹4,000 |
| 4.05 | GI pipe of 50mm bore | 200 | RM | 10 ₹2,000 Lowest | 25 ₹5,000 |
| 5.00Refixing old rerived srviceable GI pipe line on trench/wall/floor/roof of following sizes | |||||
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
3 Dec 2025, 6:00 pmClosed
Maj Ashish Kanyan
GE Kapurthala
Repairs/maintenance of GI/CI/DI pipe line including connected items at Old Mil Stn Kapurthala under GE Kapurthala.
2025_MES_733070_2
8094/E8
Open Tender
Civil Works
Item Rate
270 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹53,000
27 Feb 2026
19 Nov 2025
5 Dec 2025
19 Nov 2025
3 Dec 2025
26 Nov 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Taking down GI pipe line from trench/wall/floor/roof stacking it reuse or issued to contrctroctor as credit of following sizes
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
Refixing old rerived srviceable GI pipe line on trench/wall/floor/roof of following sizes
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
S&F GI tubing medium grade in any length with all fitting laid in trench/wall/floor/roof and connecting up with water supply main complete all as specified and directed
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
Taking down CI pipe line from trench stacking it reuse or issued to contrctroctor as credit of following sizes
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Refixing old rerived srviceable CI pipe of any description in trench of following sizes
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
S&F CI pipein any length laid in trench and connecting up with water supply main complete including jointes all as specified and directed
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
S&F in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed.
S&F in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified
All as per srl item No 11 here in before but 100 mm dia.
All as per ser item No 11 above here in before but 150 mm bore
M&L valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
M&L for lead joint suitable for CI pipe 80 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified and directed.
S&F in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 18 above here in before but 25 mm bore
All as per item ser No 18 above here in before but 30 mm bore
M &L for earth work in trenches / pit and bailing out water to rectfying leaking joint of CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 21 above here in before but 100 mm bore
All as per item ser No 21 above here in before but 150 mm bore
M&L for Painting of all CI pipes, sluice valves of main over head tank with 2 coat of synthetic enemal paint Pipe after applying one coat of primer,marking letters as directed Note Scope envolve Pipe from Top of Over head tank to Pump House all pipe over the ground in pump house is to be painted all as directed.
M&Lr and services for taking sample water in sterlised bottles from various borewells for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride) (ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish Box Make - RMCO
Supply only Calcium based granuler disinfect suitable for treatment drinking water in 45 kg plastic drum complete all as specified and directed Make: Rayal Seema/Aquafit/Daclibac
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy
Supply& Fixing bettery 12 volts 180AH Make Exide/Luminous.
S&F on load chage over switch 100 Amp, 4 pole 415 Volt, AC Supply including sheet metal enclosure factory made complete all as specified and directed.
Takeing down old u/s bleching dozing pump along with all accessories and Supply and install connecing. Testing and commissioning of High Pressuure single Head adjustable "AQUAFIT" Dosing system Model No VST 1005 and VST 1006 of the following specification. Adjustble High Pressure 5 Kg/Sq. cm. power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, Max output 10 Ltr with mandatory accessories like lead Tubing, connecting ferrules, check valves, etc (A) Preparation tank Model No VST 1005 of net capacity 100 Ltr, FRP dosing tank dia 650 x net Height 375 + conical 300. Gross height with stand 1000 mm consisting of : (i) Water inlet line (ii) Outlet with stainer (iii) Drain (iv) overflow (v) conical bottom for sludge depositing (vi) Pot hole with cover (vii) level gauge (viii) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (B) Service Tank Model No VST 1006 dia 480 x height 575 net capacity 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 900 RPM Single Phase flange mounted moto with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall Make : VARIMA of equivalent CG.
Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 30 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S& F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 25 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
Disconnecting the existing non functional submersible pump set from supply, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 80/100mm dia and existing submersible cable of any size from the bore well 150/200mm bore (approximately 100 mtr depth of pump set from GL) complete all as specified and directed. NOTE: 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost.
Lowering down of the submersible pump set after repair of any description and any capacity & in any position, in bore well alongwith column pipe 80/100mm dia and submersible cable of any size (approximately 60 mtr depth of pump set from GL) complete all as specified and directed including making necessary electric connections & testing the pump set after lowering. NOTE: 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes/pump sets/submersible cable and making necessary connections and including reconnecting water supply system. The required materials like column pipes/ /submersible cable/pump sets etc (new/old retrieved materials) shall be provided by the department to contractor for fixing and lowering in bore wells)
Supply only galvanised iron water tube 100mm bore in 3 meter length , heavy grade, ISI marked, conforming to IS-1239 (latest) for column pipe in required length but each length not more than 3.00 mtr, both end screwed with long threads/ flanged complete all as specified and directed. (NOTE: Fixing and jointing of the column pipes with sockets/flanfge, nut bolt wasers, rubber gasket are deemed to be included in the rates quoted by the contractor for lowering of the column pipes with pump sets)
Development of bores in well position with using suitable air compressor of suitable pressure (not less than 250 CFM) and capacity as approved for obtaining optimum yield and for obtaining sand free water including cast of M&L , T & P etc for developing complete all as specified & directed.
Development of bore well by over pumping with minimum 25% higher capacity of pump set after development with compressor complete all as specified and directed.
Yield test for tube well with the help of notch tank 90 degree by continuous pumping to determine safe pumping yield
Draining out water from OHT by operating wash out valve ,Cleaning of over head tank (staging from 6 meter to 18 Meter) (inside) by scraping with the help of hard brushes and physical cleaning of over head tank (reservoir) by descaling / brooming silt and other deposit in side (bottom of dome). collecting and taking them out with help of manual labour and depositing not exceeding 50mtr all as directed. Cleaning of inner surface of OHT by applying the bleaching powder solution (1:10) and left it for 1/2 hour for making surface algee/ bacteria free .clean the surface with water and drying it quick with the help of electric air blower. Applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom including writting date of cleaning with white paint on back painted surface two places and painting of inner steel ladder of tank all as specified and directed:-
S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 100 Amp 4 pole 16 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 pole 10 KA 415 Volt complete all as specified and directed.
M&L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 25 to 30 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified and directed.
All as per item 49 above here in before but capacity 35 HP
All as per item 49 above here in before but capacity 10 HP of turbine motor pump including replacerment of ball bearings.
All as per item 49 above here in before but capacity 12 HP of turbine motor pump including replacerment of ball bearings.
All as per item No 49 here in before but forNon clog motor of capacity 10 HP including replacement of ball bearings and alignment of motor starter and slote.
All as per item No 49 here in before but for submersible pump motor of capacity 2 to 5 HP including replacement of ball bearings and alignment of motor starter and slote.
Repair / replacment of unserviceable part of submersible pump capacity 25 to 30 HP such as gun metal bush impeller assembly remetaling/turning to shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per item No 55 here in before but for submersible pump for capacity 35 HP to 40 HP.
All as per item No 55 here in before but for non clog submersible pump for capacity 05 HP to 10 HP.
All as per item No 55 here in before but for openwell submersible pump motor of capacity 2 to 7.5 HP including replacement of ball bearings and alignment of motor starter and slote.
S&F Submersible pump set , Electric driven having discharge 1000 LPM at 84 mtr head including suitable capacity of electric mototr not less than 30 HP suitable for operation of 415 volts 50 C/S AC supply.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 16 sqmm in replacement of old U/S cable Make : Rallison / Plaza/Fenolax.
S&F aviation light LED type fixed on the top of OHT of any height including necessary fixing accessories complete all as specified and directed.
S&F CI double flanged Non -return valve, class 'B', High pressure PN 1.6 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed of the 150mm dia bore:- Make : Kirloskar/BIR/Minar
All as per item No 63 above here in before but 100 mm bore dia
Supply and filling pea gravel of size 3 to 10 mm to a packed thickness into the side of existing bore well (which is hollow space between casing pipe and true bore ) all as directed complete all as specified and directed.
DUGGAL CONSTRUCTION CO (BID ID -3494306)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender.pdf
Tender Documents • 1.25 MB
BOQ_829246.xls
BOQ • 2.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .