| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹18.8 L | L1 | Accepted-AOC Found L1 Bidder |
| 2 | L2₹20.5 LRejected-Finance | ₹20.5 L | L2 | Rejected-Finance Found L2 Bidder |
| 3 | L3₹21.2 LRejected-Finance | ₹21.2 L | L3 | Rejected-Finance Found L3 Bidder |
| 4 | L4₹29.3 LRejected-Finance | ₹29.3 L | L4 | Rejected-Finance Found L4 Bidder |
| 5 | Rejected-Technical WUYAN PAMPORE J K 191102 INDIA | PULWAMA | JAMMU AND KASHMIR | 191102 | - | - | Rejected-Technical Not Eligible as per NIT criteria. |
| Sl No | Description | Qty | Unit | U V ENGINEERS L4 | Blue Star Ltd L1 | V Save Electronics Pvt Ltd L3 | M/s Alpha Tech Engineers L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | VRF System
Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system suitable for 220 +/- 10 % volt, 50 Hz, 1 phase AC supply for outdoor units and 220 ± 10 % volt, 50 Hz, 1 phase AC supply for indoor units with stepless modulation complete with indoor and outdoor units,individual remote controller and compatible for centralised controller, interconnected refrigerant piping, full charge of refrigerant gas and oil, control cabling, loading & unloading etc.as per site requirements and details given in the specifications and having following items: (Refrigerant to be used shall be R410 A).
Hi Side - Outdoor Units
Outdoor unit cooling / Heat Pumps, having cooling COP not less than 3.1 at AHRI conditions and conditions equipped with efficient fully inverter scroll/rotary compressor, special heat exchanger, top discharge type, low noise condenser fan, auto check function for connection error, auto address setting and minimum capacity as mentioned below incuding MS angle frame of size 50mm x50mm x 5mm as per OEM standard complete with all accessories.
ODU - 4 HP (Heating & Cooling) | 10 | EACH | 1,82,000 ₹18.2 L | 1,00,000 ₹10 L | 1,30,550 ₹13.1 L | 1,32,000 ₹13.2 L |
| 2.00Low Side - Indoor Units - (Ceiling Mounted Cassette Units) Supply, Installation, Testing and Commissioning of Indoor Units for variable refrigerant flow airconditioning system suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with pre-filter,fan section with low noise fan, multispeed motor, coil section with DX (Direct Expansion) coil, outer cabinet, drain pan, drain water lift-up mechanism, insulation, pipe connections, fresh air intake etc. complete with PVC insulated FRLS copper conductor electric wire upto 1.5 metre length for electrically connecting the IDU with minimum capacity as given below as per specifications. | |||||||
| 2.10 | Ceiling Mounted Cassette Four Way Flow with Cassette Panel 3.00 TR Cooling Capacity with Corded Remote Controller. (Please note that the dimension of main unit shall be as per Toshiba Indoor Model No. RAV-SM 1104UT-E i.e HxWxD = 319mm x 840mm x 840mm) | 6 | EACH | 70,000 ₹4.2 L | 48,500 ₹2.9 L | 59,946 ₹3.6 L | 42,000 ₹2.5 L |
| 2.20 | Under Ceiling Mounted Cassette one Way Flow with Cassette Panel 2.50 TR Cooling Capacity complete with Corded Remote Controller (Please note that the dimension of main unit shall be as per Toshiba Indoor Model No. RAV-SM 804CT-E i.e HxWxD = 210mm x1180mm x 680mm) | 4 | EACH | 50,000 ₹2 L | 63,500 ₹2.5 L | 49,955 ₹2.0 L | 37,000 ₹1.5 L |
| 3.00 | Transmission Control Wiring
Providing and fixing transmission/control wiring PVC insulated of 2 core x 1.5 sq.mm copper conductor shielded flexible wire in 25 mm PVC conduits between outdoor to indoor and remote control unit.
(Make of cable : KEI/ POLYCAB/ HAVELLS)
(Make for conduit: BEC /AKG /POLYPACK/PRECISION /MIHIR/PRINCE.) | 70 | Meter | 180 ₹12,600 | 270 ₹18,900 | 120 ₹8,400 | 100 ₹7,000 |
| 4.00Refrigerant Piping for VRV/VRF System Supply, installation, testing and commissioning of following interconnecting copper refrigerant pipe suitable for VRF system of airconditioning conforming to JISH 3300: 1997, recessed/concealed or laid and supported on the existing slotted cable trays, duly insulated with closed cell elastomeric nitrile rubber type tubular insulation of nominal thickness as specified between indoor and outdoor units as per specification. Make: RAJCO / MANDEV / MEXFLOW | |||||||
| 4.10 | 15.9 mm (5/8 inch) OD with 0.80 mm wall thickness (Insulation : 13 mm) | 70 | Meter | 800 ₹56,000 | 925 ₹64,750 | 1,000 ₹70,000 | 600 ₹42,000 |
| 4.20 | 9.5 mm (3/8 inch) OD with 0.80 mm wall thickness (Insulation : 13 mm) | 70 | Meter | 500 ₹35,000 | 775 ₹54,250 | 1,000 ₹70,000 | 300 ₹21,000 |
| 5.00Drain Pipe Supply, installation, testing and commissioning of following Drain piping made of rigid uPVC pipe Class - 3 (6 kg/cm2) confirming to IS 4985-2000 complete with fittings, supports etc. as per specifications and duly insulated with 9 mm thick closed cell nitrile rubber insulation. | |||||||
| 5.10 | 25 mm dia (with insulation) | 70 | Meter | 180 ₹12,600 | 230 ₹16,100 | 90 ₹6,300 | 140 ₹9,800 |
Tender Value
₹23.9 L
EMD Value
₹71,599
Closing Date
20 Oct 2025, 6:00 pmClosed
SM Engg.(E)
Srinagar Airport
Provision of VRF System in Passenger Boarding Bridge at Srinagar International Airport
2025_AAI_250674_1
AAI/SNR/Engg-E/VRF
Open Tender
Electrical Works
120 days
Srinagar Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
₹71,599
22 Dec 2025
27 Sept 2025
22 Oct 2025
28 Sept 2025
20 Oct 2025
28 Sept 2025
28 Sept 2025 - 13 Oct 2025
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
FINALNITVRF.pdf
Tender Documents • 12.25 MB
BOQ_287642.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid