Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹27.0 L+₹1.5 L (5.85%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 3 | L3₹28.0 L+₹2.4 L (9.56%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 4 | L4₹28.9 L+₹3.3 L (13.1%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 5 | L5₹29.8 L+₹4.3 L (16.8%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
28 Jan 2020, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215
REPAIR TO COMPOUND WALL, FENCING, DRAIN AND OTHER MISC WORK AT SMQ/OMQ AREA AND COMPREHENSIVE MAINTENANCE OF INTERNAL E/M FITTINGS/FIXTURES UNDER GE (AF) HASIMARA
2020_MES_312727_1
C/8355/19-20/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹50,000
Yes
26 Feb 2020
7 Jan 2020
29 Jan 2020
7 Jan 2020
28 Jan 2020
22 Jan 2020
Amount
SCHEDULE 'A' PART-I Disamntling RCC post or struts any section, including taking out embedded portion in concrete and making good disturbed ground including cleaning and cutting of grass, shrubs, bushes, etc complete all as specified and directed.
Disamntling RCC post or struts any section, including taking out embedded portion in natural ground and making good disturbed ground including cleaning and cutting of grass, shrubs, bushes, etc complete all as specified and directed.
Dismantling fencing wire mesh, any type complete complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Rolled Mild Steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed
M & L for mild steel round bar 10mm dia and over cut into length, bend to shape required including cranking bending spirally for hoping as in tie bar for fixing chain link fencing complete all as specified and directed.
S & F in repair Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S & F in repair concertina coil fencing with punching tap concertina coil 960mm dia 13 mtres openable length having 53 Nos rounds per 6 metres length, single coil, fixed on wall with existing angle iron 'Y' shaped with horizontal reinforced barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing, stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron complete all as specified and as directed. (Note: (i) Weight of concertina coil shall be ascertain by a BOO to be convened by Accepting Officer (ii) Barbed wire shall be measured and paid seperately under respective items here-in-before)
All as per serial item No. 12 above but fixing only in repair of any dia complete all as directed. (Note: Old serviceable loosed concertina coil shall be refixed at site after taking down complete)
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance n.exc 100m complete all as directed by the Engr-in-Charge
Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Reinforced Cement Concrete 1:1.5:3, type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed.
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
S & F TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for Mild steel framed work such gates etc, portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in benching, coping, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel, drains etc complete all as specified and directed.
Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm including form mould, mitred/stopped etc. complete all as specified and as directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 making impressions of expanded metal whilst the concrete is green complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
Material and labour for 25 mm thick pre-polished cement concrete chequered tiles, glossy finish , smooth in design , compressive strength 300 kg/Sqcm, ISI marking (IS-13801-1993), set, jointed in neat cement slurry and pointed with white cement mixed with pigment to match over and including 20mm thick scread bed in cement mortar 1:6 complete all as specified and directed
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including pressed steel terminal box (having wall thickness 1.22mm for box upto a size 200x300mm and 1.63mm thick beyond the size 200x300mm) (Sunk Type) fixed with suitable sizes cadmium plated iron screws and washers etc. covered with 3.0mm thick backelite sheet for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and directed.
All as per item No 39 above but one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No 39 above but one 3 pin Switch socket combination, 5 Amps on Independent board complete all as specified and directed.
All as per item No. 39 above but wiring with cables of size 2.5 sqmm & cables of size 1.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specified and directed.
S & F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and as directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
S & F Ceiling rose, 3 terminal, PVC/polycarbonate, isolated body complete all as specified and directed.
S & F in repairs, Switch piano, flush type, 5 Amps, single pole, one way, 240 Volts complete all as specified and directed.
S & F in repairs, Ceiling rose, 3 Terminal, PVC/polycarbonate, isolated body complete all as specified and directed.
S & F in repairs, Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repairs, Switch socket combination 2 in 1, 6 pin, 6/16 Amps, flush type, 240 volts complete all as specified and directed.
S & F Stepped type electronic fan regulator delux rotary type complete all as specified and directed.
S & F in repairs, Stepped type, electronic fan regulator, 220 volts, rotary type complete all as specified and directed.
S & F in repairs Capacitor (oil filled) of capacity 2.5 mfd, 220 Volts complete all as specified and directed.. (Make : Universal or equivalent as approved).
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 18 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 20 and equivelant model of make as specified in list of manufacturer).
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 18 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 20 and equivelant model of make as specified in list of manufacturer).
S & F wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 9 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 10 and equivelant model of make as specified in list of manufacturer).
S & F in repair wall mounted slim LED batten, with extruded aluminium housing, with integrated LED driver with LED lamp, 9 Watt and connecting up complete all as specified and directed. (Make : Surya Cat No. SLE BT 10 and equivelant model of make as specified in list of manufacturer).
S & F in repairs, Bell, Ding-Dong, AC, 230 volts, single pole complete all as specified and directed.
S & F in repairs, lamp holder, insulated body with back plate suitable for batten fittings complete all as specified and directed.
S & F in repairs Modular switch 1 way 6A, 1 Module 250 volts complete all as specified and as directed. (Make: Legrand Cat No. 6730 00 or equivelant of make as per list of manufacturer's)
S & F in repairs Modular switch 1 way 16A, 1 Module 250 volts complete all as specified and as directed. (Make: Legrand Cat No. 6730 08 or equivelant of make as per list of manufacturer's)
S & F in repairs modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. (Make: Legrand Cat No. 6730 44 or equivelant of make as per list of manufacturer's)
S & F in repairs modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. (Make: Legrand Cat No. 6730 83 or equivelant of make as per list of manufacturer's)
S & F in repairs modular Fan step regulator, 120W - 2 module complete all as specified and directed. (Make: Legrand Cat No. 6730 29 or equivelant of make as per list of manufacturer's)
S & F in repair modular Bell push 6A, 1 module complete all as specified and directed. (Make: Legrand Cat No. 6730 18 or equivelant of make as per list of manufacturer's)
S & F in repair modular White cover plate with frame, 2 module complete all as specified and directed. (Make: Legrand Cat No. 6732 46 or equivelant of make as per list of manufacturer's)
S & F in repairs modular White cover plate with frame, 3 module complete all as specified and directed. (Make: Legrand Cat No. 6732 47 or equivelant of make as per list of manufacturer's)
S & F in repair modular White cover plate with frame, 4 module complete all as specified and directed. (Make: Legrand Cat No. 6732 48 or equivelant of make as per list of manufacturer's)
S & F in repair modular White cover plate with frame, 8 module complete all as specified and directed. (Make: Legrand Cat No. 6730 50 or equivelant of make as per list of manufacturer's)
Taking down from any position and Dismantling ceiling fan (any size/sweep/make), repair the same by cleaning, overhauling, necessary lathe work etc and taking out existing burnt out winding wire of motor and rewinding the same after proper cleaning with super enamelled copper wires as per existing gauge and turn to achieve the desired RPM, necessary insulating materials, insulating varnishing, cleaning and reassembling the ceiling fan after replacement of unserviceable minor parts such as split pin, lock nuts, rubber packing, clamp of condenser, blade nuts, rubber reel insulator, nuts bolts, plastic fan canopy etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc and testing complete on completion and re-fixing the fan in existing position including provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop from site of work)
All as per item No 70 above but for exhaust fan upto 600mm sweep complete and ditto.
Supply only Capacitor for ceiling fan of capacity 2.5 mfd (PVC body) + 5%, 220 volts, 50 Hz conforming to IS - 1709 AAPHS, temperature Max 85 degree centrigate complete all as specified and directed. (Make: NICCO, SIEMENS, EPCOS, Universal & TIBCON)
Supply only Gun metal bush for suitable size of existing motor shaft for ceiling fan complete all as directed. (Make:- Orient, Usha, Ganesh ,Khaitan, MIE)
Supply only Ball bearing No 6200/6201/6202/6203 complete all as directed (Make : TATA/SKF/NBC/HCH).
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing MCBs complete all as specified and directed. (Make : Legrand Cat No. 5076 10 or equivalent model as approved)
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts, IP 43 & IK 09 protection suitable for housing MCBs complete all as specified and directed. (Make : Legrand, Cat No. 5076 11 or equivalent model as approved)
S & F sheet metal enclosure, double door MCB DBs, phosphatised, powder coated, single pole & neutral (SPN), 12 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed. (Make : Legrand, Cat No. 5076 12 or equivalent model as approved)
S & F factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, VTPN, 6 way, 415 Volts suitable for fixing MCCBs complete all as specified and directed. (Make : Legrand Cat No. 5077 51 or equivalent model as approved)
S & F MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' series, 10KA capacity complete all as specified and directed. (Make: Legrand Cat No. 4086 14 - 17 or equivelant of make as per list of manufacturer)
S & F in repairs MCB, SPN, 240 Volts, 6-32 Amps, 'C' series, 10KA capacity complete all as specified and directed. (Make: Legrand Cat No. 4086 09-17 or equivelant of make as per list of manufacturer)
S & F MCB, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity, 240 Volts complete all as specified and directed. (Make: Legrand Cat No. 4085 87-95 or equivelant of make as per list of manufacturer)
S & F in repairs MCB, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity, 240 Volts complete all as specified and directed. (Make: Legrand Cat No. 408587-95 or equivelant of make as per list of manufacturer)
S & F in repairs MCCB, 4 pole, 415 V with fixed thermal & fixed magnetic setting, 63 Amps of breaking capacity 36 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 93 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 4 pole, 415 V with fixed thermal & fixed magnetic setting, 100 Amps of breaking capacity 16 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 15 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 4 pole, 415 V with fixed thermal & fixed magnetic setting, 160 Amps of breaking capacity 25 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 57 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 3 pole, 415 V with fixed thermal & fixed magnetic setting, 100 Amps of breaking capacity 25 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 45 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 3 pole, 415 V with fixed thermal & fixed magnetic setting, 160 Amps of breaking capacity 25 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 47 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 3 pole, 415 V with fixed thermal & fixed magnetic setting, 125 Amps of breaking capacity 16 KA complete all as specified and directed. (Make: Legrand, Cat No. 4200 06 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 4 pole, 415 V with fixed thermal & fixed magnetic setting, 200 Amps of breaking capacity 25 KA complete all as specified and directed. (Make: Legrand, Cat No. 4202 18 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 3 pole, 415 V with fixed thermal & fixed magnetic setting, 250 Amps of breaking capacity 36 KA complete all as specified and directed. (Make: Legrand, Cat No. 4202 39 or equivelant approved make as per list of manufacturer)
S & F in repairs MCCB, 4 pole, 415 V with fixed thermal & fixed magnetic setting, 250 Amps of breaking capacity 36 KA complete all as specified and directed. (Make: Legrand, Cat No. 4202 49 or equivelant approved make as per list of manufacturer)
Supply, install, testing & Commissioning, Geysers, water heater, 25 ltrs capacity, Storage type electrically operated on single phase 230 Volts AC, 5 Star rating with all accessories and connection of inlet & outlet pipe line including connecting up with 3 single core PVC insulated, multistranded copper conductor cables including taking down existing unserviceable water heater complete and removing to MES store yard complete all as specified and directed. (Make : Havells, Model : GHWAPTTWH025 or equivelent model as approved by the Engr-in-Charge/GE)
S & F Exhaust fan, 200 mm sweep, AC, single phase complete with all accessories and electric connection including taking down existing unserviceable fan and removing to MES store yard complete all as specified and directed (Make : Havells, Model : Ventil Air DX white or equivalent model of Bajaj/Usha/ Khaitan/Orient as approved)
S & F in repair post top lanterns, black painted, cast aluminium, spun aluminium funnel shape with clear acrylic cover, light opening on canopy with baffles and accessories including 2 Nos CFL 2 x 11 watts lamp, including connection complete all as specified and directed. (Make:- C & S Model No. LTGL001or equivalent model of make as per List Manufacturer's as approved).
S & F in repair semi automatic star delta starter, suitable for 7.5 to 10 HP pump motor rating AC-3 duty, 415V, 50 Hz, 3 phase in poweder coated enclosure with gasket including electrical connections complete all as specified and directed. (Make: C & S/Siemen's/L&T/ABB or equivelant as per list of manufacturer)
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 25x4mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one as specified and as directed.
M/S. NARENDRA KUMAR GARG
M/S DEY ENTERPRISE
M/S RATHIN ENTERPRISES
B L SHARMA
M/S. KUMAR CONSTRUCTION CO.
M/S ANIL KUMAR BAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .