₹74,000
Closing Date
16 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT
REPAIR/MAINTENANCE OF ELECTRICAL ASSETS/EQPT AT VARIOUS LOCATION AND OTHER MISC WORK UNDER GE (E/M) LUCKNOW
2020_MES_353874_1
CWE/LKO/EM/T-10 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LUCKNOW
MES contractors enlisted in Class D and category b(ii) and for un enlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹74,000
Yes
31 Jul 2020
18 Jun 2020
18 Jul 2020
18 Jun 2020
16 Jul 2020
4 Jul 2020
60 days
Amount
Supply and fixing in repairs 1.5 volts Lithium battery, rechargable suitable for fixing in relays of RMUs as per sample complete all as specified and directed.
S & F in repairs Air Circuit Breakers (ACBs) 4 Pole, 415 Volts 630 Amps, AC 50 Hz, with breaking capacity 50 KA, conforming to IS/IEC 60947-2 with thermal magnetic release (manual drawout type) main CTs for three phase, with shunt trip coil of suitable capacity including dismantling the old one from the site complete all as specified and directed. Make - L&T/ ABB/ CG
Supply & Fixing Battery 2 Volt, 100 AH for battery bank installed at sub stations complete with termination clips complete all as specified and directed.
Supply & Fixing battery charger suitable for charging to battery bank 2 volts 100 AH (24 Nos) including digital type volt meter, Amp meter etc complete all as specified and directed.
Supply, fixing and testing in repairs Power Pack units with maintenance free solid batteries in sheet metal enclosure with arrangements for mounting on the existing 11 KV VCBs panels with nuts and bolts and capable of providing 30 V DC current to the VCBs during power failure for a continuous period of not less than 12 hours, for functioning of relays, charging motor and other parameters complete all as specified and directed.
Supply and fixing in repairs Voltage Transformer of ratio 1100 RT3/110RT3V Acc. Class 1.0 Burden 200VA STC 25KA for 1 sec including copper extension strips of required size and rating complete all as specified and directed by Engineer-in-Charge.
Supply & install HT 33 KV, single phase out door oil cooled PT of ratio class 0.5-3 burden 50 VA complete all as specified and directed.
Supply & install HT 33 KV, single phase out door oil cooled CT of ratio 400/5-5 Amp class 1/5P 10 burden 15 VA complete all as specified and directed.
Supply & install HT 11 KV, single phase out door oil cooled PT of ratio class 0.5-3 burden 50 VA complete all as specified and directed.
Supply & install HT 11 KV, single phase out door oil cooled CT of ratio 400/5-5 Amp class 1/5P 10 burden 15 VA complete all as specified and directed.
Supply and fix in repair batery bank of capacity 24 volt consisting of (02 Nos each of 12 V maintencance free battery of 120 AH capacity make Exide/Amron) with replacement of battery bank of capacity 24 V, consisting of (24 Nos) of 02 Volts Each 120 AH maintenance free "exide" make for system voltage 24 V, including disconnection of old U/S Battery bank complete all as specified and directed.
Supply and fix cable jointing kit 11 KV(Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit 11 KV(Earthed) grade cable for outdoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 95 sqmm, Indoor/Outdoor type complete all as specified and directed.
M&L for disconnecting burnt end or portion of 50 sqmm to 400 sqmm 3 core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying the same, and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals of HT cable to pole/VCB / main switch etc complete all as specified and directed.
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc. all as specified and directed.
M & L for opening the existing RMUs of 11 KV rating, disconnecting the HT cables of any size and servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing & gas charging for repair and replacement of defective components of RMU, lamp indicators, caliberation of relays & digital meters, over load protection relay, time delay relay / earth fault relay, charging spring etc. Cleaning the fixed and moving contact inside the RMUs properly, servicing and greasing all moveable mechanism, replacement of defective fuses, wiring and reassembling and testing complete all as specified and directed. Note :-(i) The contractor shall arrange for the standby supply for testing of relays, (ii) The rates quoted by the contactor shall include cost of any other spare parts/relay not mentioned herein but essentially required for functioning of the system.(iii) Testing of above job to be carried out by engineers of authorised dealer/services centre of concerned OBC (iv) No extra payments will be made to the contractor for the same.(v) Unit rates quoted by tenderers shall deem to include for, bolts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
S & F in repairs copper bus bars of 200 Amps rating suitable for LT/HT Panels as per existing dimensions including drilling holes and nuts, bolts and washers of suitable size & taking out old burn out old bars complete all as specified and directed.
S & F in repairs Aluminium bus bars of 200 Amps rating suitable for LT/HT Panels as per existing dimensions including including drilling holes and nuts, bolts and washers of suitable size & taking out old burnout old bars complete all as specified and directed.
Supply and install HT triple pole 33 KV outdoor type gang operated air -break switch suitable for horizontal or vertical mounting on steel frame fixed type with drop out fuse having 12 insulators of rating upto 200 Amp, mechanically complete all as specified and directed.
Supply and install HT triple pole 11 KV outdoor type gang operated air -break switch suitable for horizontal or vertical mounting on steel frame fixed type with drop out fuse having 12 insulators of rating upto 200 Amp, mechanically operated complete all as specified and directed.
Supply and fixing lightning arrester, HT, suitable for 33 KV, expulsion type complete with all fittings, transmission class, discharge capacity 10 KA complete and connecting to conductors and earthing complete all as specified and directed.
Supply and fixing lightning arrester, HT, suitable for 11 KV, expulsion type complete with all fittings, transmission class, discharge capacity 10 KA complete and connecting to conductors and earthing complete all as specified and directed.
Supply and fix in repairs Post insulator of type 11 KV, E-22, IS 2544 with height 254 mm, tensile strength (Kg) 20 KN and compressive strength in (Kg.m.) 40 KN suitable for fixing with the existing GOD's complete all as specified and directed.
M &L for Repair to ring main tee non expandable type one VL two OD with fault making and breaking isolator complete replacement of main insulator, bus bar and joint with fish plate gaskets and one No. fuse carrier assembly HT 11 KV suitable upto 20 Amps of existing model complete all as specified and directed.
Supply and fix in replacement HRC fuse for Ring main unit , HT 11 KV, 10 to 16 A capacity, of existing make and model complete all as specified and directed.
Supply and fix in replacement fuse carrier assembly with HRC fuse suitable for Ring main unit 20 Amps unit HT 11 KV as per sample complete all as specified and directed.
Taking down carefully any type of point wiring complete including conduits/casing capping with fittings such as light fittings, sockets, switches ceiling roses, boards out lets etc and removing the material and making good the disturbed surfaces of walls, floor etc
M & L for point wiring complete as specified with 1100 Volts grade 1.5 Sqmm two single core PVC insulated unsheathed cable with stranded copper conductor drawn through PVC conduit with all accessories concealed in wall / ceiling including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet with 2.8 mm thick hylam/ plastic laminated sheet top cover including cutting chases, pinning in, making good to facings where required and painting in cement mortar & with 1.5 Sqmm PVC insulated unsheathed copper conductor cable as earth wire connected to common earth dolly for the following :-
One light/fan/Exhaust fan/security light point controlled by one switch
One 3 pin socket outlet 5 amp on same board
One 3 pin socket outlet 5 amp on independent board
All as per item No.29 herein before but 2.5 Sqmm PVC insulated and unsheathed copper conductor for switch socket combination 6 pin 15 amps on independent board
S&F in repair switch Piano flush type 5 amp single Pole one way complete all as specified and directed.
S&F in repair switch socket combination flush type multipurpose 3 pin suitable for 5 Amps plug top controlled by one switch complete all as specified and directed.
S&F Switch Socket combination multipurpose 3 pin 5 & 15 Amps flush type complete all as specified and directed.
S&F in repair ceiling rose surface bakelite surface 65 x 50mm 3 terminals fixed on and including PVC block complete all as specified and directed.
S & F Energy efficient Fluorescent light fitting 1 x 36W with instant start, flicker electronic operation. Easy to fit snap on adjustable installer including tube rod complete all as specified and directed.
M&L for sub main wiring with four runs (3 Phase + 1 Neutral) of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 4 Sqmm size incl 25 mm dia PVC conduit fixed in wall (concealed) incl one run 2.5 Sqmm PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed.
M&L for sub main wiring with two runs of single core PVC insulated unsheathed 1100V grade multistranded copper conductor cable 6 Sqmm size incl 25 mm dia PVC conduit fixed in wall (concealed) incl one run 4 Sqmm PVC insulated unsheathed copper conductor cable as earth wirecomplete all as specified and directed.
S & F step regulator electronic rotary type 230 volts.complete all as specified and directed.
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc inlcuding writing MES No. with balck colour synthetic enamel paint complete all as specified and directed.
M & L for taking out old u/s ceiling fans from various substaitons and cutting the worn out winding and rewinding with suitable guage copper wire complete all as specified and directed.
M & L for capacitors for ceiling fans of 2.5 MFD complete all as specified and directed.
M & L for taking out old worn out bearing of the ceiling fans and fixing with new bearring of suitable size complete all as specified and directed.
M & L for taking out the old u/s exhaust fans upto 600mm sweep from various substations/locations and cutting the worn out windings and rewinding the same with suitable guage copper wire, including capcitor of suitable capacity, and other repair work as required, including painting with two coats of synthetic enamel paint of existing tint/colour complete all as specified and directed.
M & L for taking out the old u/s ceiling fans upto 1400mm sweep from various substations/locations and cutting the worn out windings and rewinding the same with suitable guage copper wire, including capcitor of suitable capacity, any other repair work required, including painting with two coats of synthetic enamel paint of existing tint/colour complete all as specified and directed.
S & F DB TPN 4 Way, 415V with 200 Amps rated bus bar of IP-43 'B' Class complete all as specified and directed.
S & F DB SPN 04 way of IP-43 'B' Class with 200 amps rated bus bar, 415V with single door complete all as specified and directed.
S & F DB SPN 06 way of IP-43 'B' Class with 200 amps rated bus bar, 415V with single door complete all as specified and directed.
S & F MCB Four Pole upto 32 Amps capacity, 415V of 'B' Class complete all as specified and directed.
S & F MCB SP upto 20 Amps 230 Volts of 'B' Class. complete all as specified and directed.
S & F MCB Single Pole & neutral upto 32 Amps 230 Volts of 'B' Class, 415 V complete all as specified and directed.
S & Fix in repairs MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 10 KA including spreader terminals complete all as specified and directed.
S & Fix in repairs MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 KA including spreader terminals complete all as specified and directed.
S & F in repairs MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 KA including spreader terminals complete all as specified and directed.
S & F in repairs MCCB 4 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 KA including spreader terminals complete all as specified and directed.
S & F in repairs MCCB 4 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 KA including spreader terminals complete all as specified and directed.
S & F in repairs MCCB 4 Pole of capacity 400 Amps, 50 Hz, 415V with rupturing capacity of 50 KA including spreader terminals complete all as specified and directed.
S & F MCCB in repairs MCCB 4 Pole of capacity 630 Amps, 50 Hz, 415V with rupturing capacity of 50 KA including spreader terminals complete all as specified and directed.
Supply and fixing as in repair LED Bulb 18 W pin type suitable for fixing of holder complete all as specified and directed.
Supply and fixing as in repair LED Tube rod 36 W suitable for fixing of fitting complete all as specified and directed.
Supply and fixing as in repair LED street light pressure die cast aluminium housing suitable for 45W IP 66 protection including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fitting complete all as specified and directed.
S&F Exhaust fan with louvers complete AC Three phase 415V of size 600 mm sweep, including making all necessary connection complete all as per specified and directed.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated including fastener and fan hook complete all as specified and directed.
M&L lamp holder , insulated body, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M&L for installation, testing and commissioning of Inverter sine wave 2300 VA capacity including trolly complete all as specified and directed.
M&L for installation of Tubler Battery 12V, 180 AH, DC suitable for inverter complete all as specified and directed by engr-in-charge
M/s Reliable Electromech Systems
M K Engineers and Contractors
Unnati Engineers
Prime power system
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .