Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC lowest bid quoted | |
| 2 | L2₹26.5 L+₹5.3 L (25.2%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted | |
| 3 | L3₹28.8 L+₹7.7 L (36.3%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
27 Nov 2021, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
REPAIR REPLACEMENT OF DEFECTIVE WIRING SUB MAIN DBS INTERNAL FITTINGS ALONGWITH CONNECTED ACCESSORIES AT VSV AREA AT AF STN GURGAON UNDER AGE EM AF GURGAON OF GE AF GURGAON
2021_MES_484968_1
CA NO GE/GUR-/NIT-72/2021-22
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹78,000
10 Dec 2021
29 Oct 2021
29 Nov 2021
29 Oct 2021
27 Nov 2021
12 Nov 2021
Amount
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
Taking down unserviceable sub main wiring of any type/size including wires, conduits/battens etc complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable MCB DB's/AC's box of any size/rating complete all as specified and directed by Engr-in-charge.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed FRLSH Grade cable 1100 volts grade confirming to IS: 694 for phase and neutral drawn in and including medium duty concealed PVC conduit confirming to ISI marked not less than 20mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :- Note: - This is maint work for routine daily complaints and keeping in view the fact contractors has to deply Elect & Helper to complete the daily works alloted and the work shall be completed within 48 hrs failing which Rs 200/- per complaint/day shall be recovered from the contractor.
One light point controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One fan point/Exhaust fan controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size all as specified and directed.
One 5 pin socket oulet 5/6 amps on same board including single core stranded copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth dolly all as specified.
One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sqmm of size all as specified and directed.
One light point controlled by two 2-way switches, with cables 1.5 sqmm size all as specified and directed.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed FRLSH Grade cable 1100 volts grade confirming to IS: 694 drawn in and including medium duty PVC casing caping confirming to ISI marked not less than 20mm including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :-
One light point controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One fan point/Exhaust fan controlled by one switch with cables 1.5 Sqmm size all as specified and directed.
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size all as specified and directed.
One 5 pin socket oulet 5/6 amps on same board including single core stranded copper conductor 1.5 Sqmm PVC insulated and unsheathed cable drawn in same conduit as earth wire to the common earth and connecting to earth dolly all as specified.
One 5 pin socket oulet 5/6 amps on independent board including single core straned copper conductor 1.5 sqmm PVC insulated and unsheathed cable drawn in nsame conduit as earth wire to the common earth and connecting to earth dolly all as specified.
-Ditto- item No 5.05 but one 3 pin socket outlet, 15 Amps on independent boards with cables 2.5 Sqmm size complete all as specified and as directed.
M&L for point wiring complete with stranded copper conductor 4 Sqmm size (Nominal area) PVC insulated unsheathed FRLSH cable 1100 volts grade confirming to IS: 694 drawn in and including medium grade concealed PVC conduit confirming to ISI marked not less than 25mm dia with concealed sunk-in pressed steel terminal boxes of required size not less than 1.2 mm thick factory made and painted with stove enamelled black paint top cover 2.80 mm thick plastic laminated sheet of required colour fixed with brass screwes and cup washers including single core stranded copper conductor 4 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for one 6 pin socket outlet two in one 16/6 Amps on an independent board. (for geysers point) Note : 1) For item No 2, 5 & 6 Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. No Extra payment will be done on this account 2) The work is of day to day repair nature. Contractor has to engage a supervisor to collect the complaint slips from the department on day to day basis and complete the job in 2 days.
-Ditto item No 7 but with cable 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm stranded copper unsheathed complete all as specified and as directed.
Supply and fix in repairs switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
Supply and fix in repairs switch piano, flush type single pole, two way, 5 Amps, 240 volts all as specified and directed at site.
Supply and fix in repairs bell push flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
Supply and fixing in repairs socket outlet 2 in 1, 3 pin 5 Amps all as specified and directed at site.
Supply and fix switch in repairs socket combination 5 Amps/16 Amps, 5 in 1, flush type all as specified and directed at site.
Supply and fix in repairs ceiling roses, 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
Supply and fix in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed at site.
Supply and fixing in repairs calling bell ding dong, AC 230 volts, single pole complete all as specified and directed at site.
Supply and fix in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps/16 Amps, 2/3 pin combined 2 module complete all as specified and as dirceted.
Supply and fix in repairs modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular bell push 6 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs White cover plate with frame, 1 module complete all as specified and as directed.
Supply and fix in repairs White cover plate with frame, 2 module complete all as specified and as directed.
Supply and fix in repairs White cover plate with frame, 3 module complete all as specified and as directed.
Supply and fix in repairs White cover plate with frame, 4 module complete all as specified and as directed.
Supply and fix in repairs White cover plate with frame, 6 module complete all as specified and as directed.
Supply and fix in repairs metal flush box 1/2 module complete all as specified and as directed.
Supply and fix in repairs metal flush box 3 module complete all as specified and as directed.
Supply and fix in repairs metal flush box 4 module complete all as specified and as directed.
Supply and fix in repairs metal flush box 6 module complete all as specified and as directed.
Supply and fix in replacement of 20 watt (4ft long) decorative box type fitting with blue coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
Supply and fix in replacement of 12 watt 2 ft decorative box type fitting with coloured end caps for LED tube etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block and testing complete all as specified and directed at site.
Supply and fix in replacement of surface mounting 12W LED frame less panel square in shape fixture with white powder coated CRCA housing and elegent diffuser complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Cat Part No: LD00118018 Make: Polycab
Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemed to be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job.
Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed. Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
Supply and fix in replacement of LED building light luminaire 30 watt, pressure die cast aluminium housing with heat resistant toughened glass & IP66 protection complete all as specified and as directed. Make:- Cat.No. PCGLS 01 30 of polycab or equivalent in Havells/Crompton.
M&L for in replacement of bracket made from GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 mtr in length and fixed on wall/pole including necessary MS clamps, nuts, bolts and washers including welding and painting complete all as specified and as directed.
Supply and fix lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting including with one number 12 watt LED lamp complete all as specified and directed.
Taking down of fitting bracket/ceiling/bulk head/tube light fitting of any size complete all as specified and as directed.
S&F in replacement of 3mm thick hylum sheet top cover of size 11" x 9" on switch boards wherever damaged the switch boards including the cutting, fixing and screwing etc all as specified and directed at site.
S&F in replacement of 3mm thick hylum sheet top cover of size 8"x 5" on switch boards wherever damaged the switch boards including the cutting, fixing and screwing etc all as specified and directed at site.
S&F in replacement of 3mm thick hylum sheet top cover of size 4"x4" on switch boards wherever damaged the switch boards including the cutting, fixing and screwing etc all as specified and directed at site.
S&F domestic surface mounting 1 gang box for fixing of socket outlet and switches complete all as specified and as directed.
S&F domestic surface mounting 2 gang box for fixing of socket outlet and switches complete all as specified and as directed.
S&F domestic surface mounting 3 gang box for fixing of socket outlet and switches complete all as specified and as directed.
S&F domestic surface mounting 4 gang box (double domestic) for fixing of socket outlet and switches complete all as specified and as directed.
S&F domestic surface mounting 5 gang box (double domestic)for fixing of socket outlet and switches complete all as specified and as directed.
S&F domestic surface mounting 6 gang box (double domestic)for fixing of socket outlet and switches complete all as specified and as directed.
Supply and fix in replacement MCB, DB , SPN 8 way suitable for single phase 240 volts with 100 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCB's single/double pole complete all as specified and directed at site.
Supply and fixing in replacement of MCB signle pole 5-32 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fixing in replacement of MCB single pole and neutral 40 /63 Amps 230 volts 'B' series complete all as specified and as directed at site.
Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and directed by Engineer-in-Charge. Make:- Model No 607841 of Make Legrand or equivalent in Siemens/Hagger/L&T.
Supply & fix in replacement of plug and socket for metal clad box complete all as specified and directed by Engineer-in-Charge. Make:- Legrand or equivalent in Siemens/Hagger/L&T.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core FRLSH Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F submain wiring with unsheathed multi-stranded FRLSH Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core FRLSH Grade and one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
S&F vertical type load line distribution board, double door, 4 way AC, 3 phase 415 volts, TPN bus bar 200 Amps rating and earth bus and din rail including 01 No. MCCB 3 pole 415 volts, 50 Hz, 100Amps 10 KA breaking capacity as incomer complete .
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 63 Amps with breaking capacity 16 KA and dismantling of old unsv MCCB and connecting testing with MCCB complete all as specified and directed.
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 100 Amps with breaking capacity 16 KA and dismantling of old unsv MCCB and connecting testing with MCCB complete all as specified and directed.
Supply and fixing in replacement of MCB SPN 32-40 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fixing in replacement of MCB TPN 40-63 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fixing in replacement of MCB TPN 100 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fixing in replacement of MCB TP 40-63 Amps 230 volts 'B' series complete all as specified and as directed.
Supply and fix in repairs recessed mounted high transparent diffuser fitting suitable for 600 mm x 600 mm modular/ POP/Gypsum ceiling complete with all accessories and including connecting up with twin core sheathed flexible copper conductor cable with high brightness LEDs with driver of capacity 36W LED 6000K complete all as specified and as directed.Make:- Polycab or equivalent in Havells/ Crompton.
Supply & fix capacitor of 2.5 mfd complete all as specified and directed.
-Ditto item No 65 but 3.15mfd complete all as specified and directed.
-Ditto item No 65 but 4.0 mfd complete all as specified and directed.
Supply and fix PVC insulation tape 18mm width and 25 m Length complete all as specified and directed.
Suply and fixing and connecting flexible copper twisted twin core of size 23/.00076 complete all as specified and directed by Engineer-in-Charge.
S & F plug top 6 Amps, 240 volts complete all as specified and as directed.
S & F plug top 16 Amps, 240 volts complete all as specified and as directed.
S & F heavy duty PVC cable 1100 volts grade , insulated aluminium stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed.
S & F heavy duty PVC cable , 1100 volts grade insulated aluminium stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed.
S & F heavy duty PVC cable, 1100 volts grade insulated aluminium stranded conductor, twin core wire of size 10 sqmm complete all as specified and as directed.
Supply and fixing rubber shackle complete with bolt, nut, split pin complete all as specified and as directed.
Material and labour for shifting & fixing of old serviceable exhaust fan and making circular opening by cutting stone wall 40cmx40cm thickness 38cm complete with inserting hume pipe collar of internal dia 225mm & length 38 cm and filling all around (between wall and outer dia of hume pipe collar) with PCC (1:2:4) B0 12.5mm graded aggregate and grouting 04 Nos bolts of size not less than 10mm dia and 100mm long with nut & washer and making good to distrubed surface..(Note:- Neccessary support in high rise building (ground floor to third floor) for working from out side shall be deemed inclusive).
Material and labour forShifting & fixing ceiling fan with down rod including necessary holes, nuts and bolts, pin as directed by Engineer-In-charge.
Material and labour for fixing fan down rod 15mm dia 2 ft long including necessary holes, nuts and bolts, pin in replacment of old u/s down rod as per site requirement all as directed by Engineer-In-charge.
Material and labour for fixing fan canopy in replacment of old broken u/s canopy as per site requirement all as directed by Engineer-In-charge.
Supply and fixing of ceiling fan 1200mm sweep 230Volts complete with electronic step type regulator 5 star rating and accessories as required for hanging, mounting complete as specified and directed by Engr-in-Charge. Model ES-40 Make:- Havells or equivallent model in Bajaj/ CG/ Usha
Material and labour for fixing plastic body exhaust fan blades for 250 mm sweep in replacment of old u/s platic body exhaust fan blade as per site requirement all as directed by Engineer-In-charge.
Supply & fix capacitor of 0.85/1.00 mfd complete all as specified and directed.
Material and labour for fixing fan motor alongwith suitable blades with holding cap as per existing make/model suitable for plastic body exhaust fan upto 250 mm sweep in replacment of old u/s motor of exhaust fan all per site requirement all as directed by Engineer-In-charge.
S&F ventilation fans plastic body, 150mm sweep Ventil Air DXW Make: Havells or equivalent model in Bajaj/ Phillips/ CG
S&F ventilation fans plastic body, 100mm sweep Ventil Air DXW Make: Havells or equivalent model in Bajaj/ Phillips/ CG
S&F water heater vertical type ivory in clour Cat Part No GSI/3025, rated power 2 KW, Make: Havells
S&F ceiling fan 1250mm sweep, aerodyanamic profile blades for silent operation with high twist angles leading to high air delivery, rust free re-inforced ABS blades, dust and mark resistant caoting pearl white Stealth Air make: Havells or equivalent model in CG/Usha
S&F ventilations fans metal 300mm sweep, double ball bearings, heavy duty motor with protective steel bird guard model Ventil Air DB make: Havells
Surjit and Sons
D P ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .