HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, MES, SHILLONG, MEGHALAYA
IMPROVEMENT OF HT LT DISTRIBUTION WITH CABLE AND FEEDER PILLAR BOXES UNDER GE SHILLONG
2024_MES_681817_1
89786/SHL
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
SHILLONG
ALL AS PER NIT AND TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,000
GE SHILLONG
₹1.3 L
Yes
24 Dec 2024
29 Oct 2024
12 Dec 2024
30 Oct 2024
10 Dec 2024
22 Nov 2024
Amount
NOTE (Applicable for all items):- The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A'
Supply, installation, testing & commissioning of 33KV 630Amps 25kA-3sec Indoor type floor mounted compact SF6 Gas Insulated Switchgear with internal copper bus bars, consisting of with two Nos. motorized Load Break Switch as incomer and two nos motorised Vacuum Circuit Breaker as outgoings along with Bus connect Air Insulated PT Panel. All live parts, bus bars, LBS & VCBs connections, ON-OFF offload switch, Earth switch of feeder should be enclosed in one tank sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. SF6 Gas Tank and cable chamber should be tested for an internal arc fault of 25kA for 1 sec with AFLR classification. All four modules LBS and VCB should be enclosed in one SF6 tank to avoid multiple connections. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown at site (to avoid dismantling of SWG and rectification at OEM factory for minor gas leakage issues due to bushing breakage). The Gas Insulated switchgear should be complete with all accessories and should be suitable to connect cable upto 1RX3Cx400sqmm. VPIS, cable supports, all front cable terminations, mechanical indications for VCB, OFF load switch & Earth switch, Manometer as per with IEC standards 62271-1, 100, 200. Altitude of installation up to 1500m as per IEC 60120. The unit shall include the following with all necessary standard fitting required at site. Product from License partner / Authorized Integrators are not accepted.
VACUUM CIRCUIT BREAKER feeder 630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity-2 Nos. Motor operated 630 A Vacuum circuit breaker having spring stored mechanism. ON-OFF off load switch and earthing switch downstream vacuum circuit-breaker. Menometer per tank per feeder. “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 25KA/ 3 sec, Making Capacity - 62.5KA, VCB must confirm operating sequence O-0.3sec-CO-3Min-CO and 10000 mechanical operation., Power frequency withstand voltage - 70KV & Impulse withstand voltage - 170KV Front cover mechanism - IP2X. Green(ON)/Red(OFF) push buttons to operate VCB. Indication Lamp for ON, OFF, TCS, TRIP, SPRING CHARGE etc., Auxiliary powered numerical protection relay having Over Current, erath fault, Over Voltage & Undervoltage with IEC61850 complaint rear RJ45 port with programable 10 DO & 16DI. Multifunction meter with MODBUS communication - 1No. (Each VCB) Cast Resin Ring core CT for metering on cables 100-50/1A, Class: 0.5 2.5 VA - 3 Nos Cast Resin Ring core CT for protection on cables 100-50/1A, 5P10 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication, Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Switchgear VCB, Vaccum Interrupter, Relay must be of same make and SCADA compatible suitable to system
LOAD BREAK SWITCH feeder 630A Load Break Switch module for making of fault current alongwith Earth Swicth of full making capacity-2 Nos. (Mechnical inter lock between 2 load break switch - 2 lock and one key to avoid parallel operation of LBS) Motor operated 630 A Load Break Switch having snap action mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 25kA/ 3 sec Making Capacity - 62.5KA, Power frequency withstand voltage - 70KV, Impulse withstand voltage - 170KV Front cover mechanism - IP2X, Cable covers - 3X, Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Fault passage Indicatory to be given along with LBS module One Bus Connected Air insulated equipment / metering cubicle consisting of following 3 nos. Single Phase PTs - 33kV/V3/110/V3 ,Cl-0.5 & 3 P , 50VA Space Heater with thermostat, Suitable Analog Voltmeter with VSS 24V DC and 230V AC supply shall be extended at Site by Client. Supply of Electricals Bushing of 36kV of offered SF6 Insulated SWG with suitable O-Rings - 3Nos (1set) in spare (Mandatory) for replacement at site. Final commissioning should be done in supervision of SWG OEM only.
Supply, Fixing and termination of Indoor 36kV Screen Connectors suitable for 3kV XLPE cable upto 1RX3CX400Sqmm ,as per recommended make of 36kV Sf6 Insulated SWG supplier. Screen Connectors should be terminated in 36kV CSG by "certified jointer" only duly certified by SWG Manufacturer or supplier of Screen Connector.
Material & Labour for earthing complete with copper earth plate electrode size 600x600x3.15 mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including copper strip 20x3 mm earth lead by means of bolts, nuts, check nuts and washers of copper/brass material and GI pipe light grade 25mm bore dia for protection of earth lead strip and 40mm bore dia GI pipe light grade for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTE: The unit rate includes for protection pipe and Copper strip from top of earth plate upto 5.00 meter above ground level
Material & Labour for earthing complete with galvanised steel earth plate electrode size 600x600x6 mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 40mm bore dia for protection of earth lead strip and 40mm bore dia GI pipe light grade for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTE: The unit rate includes for protection pipe and GI strip from top of earth plate upto 5.00 meter above ground level
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 3KVA complete all as specified and directed
Supply installation testing and commissioning SITC OTI & WTI module with RS 485 Port for distribution transformer 11 kV/ 433 kV complete all as directed.
Supply and fix HT 33 KV out door type gang operated air-break switch double stack type suitable for horizontal/vertical mounting fixed type with Earth switch complete with 9 insulators of rating upto 400 Amps including taking down old complete all as speified and directed
Supply, laying & testing cable 33000 Volts (E) XLPE insulated with Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of size 1 core 185 sq mm complete all as specidied and as directed.
Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for single core XLPE, armoured, Al conductor cable of size 185 sqmm complete all as specidied and as directed.
Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated including taking down old complete all as specidied and as directed.
Material & Labour for ACSR conductor of suitable size including taking down old complete all as specidied and as directed.
Supply and fix lightning arrestor HT 33 KV 10 KA station class complete all as specidied and as directed.
Material & Labour for 32 x 6 mm copper strip including connection from earthing in continuation to end point complete all as specidied and as directed.
Material & Labour for 100 mm bore GI tubing light grade ISI marked for protection of cable including necessary joint complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specidied and as directed.
Material & Labour for brickwork in Cement Mortar (1:4) using sub class B bricks, old size straight or curved on plan exceeding 6 Mtr mean radius, for construction of cable duct including cover complete all as specified and as directed.
Material & Labour for 15mm thick in cement mortar (1:4) rendering on fair face of brick work finished even & smooth without using extra cement, complete all as specified and as directed.
PURBANCHAL BUILDERS (BID ID -3181208)
SAGGI ELECTRIC COMPANY (BID ID -3176102)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .