Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
12 Feb 2024, 3:00 pmClosed
Project Director, INRPC
Project Director, INRPC, BARC Tarapur
Refurbishment of 415V LT Panels for providing Construction Power Supply at INRP Site and Minor Assorted Installation Works at INRP Main Substation Tarapur
2024_NRB_788993_1
BARC(T)/NRB/INRPC/ELE-50/2023
Open Tender
Electrical Works
Item Rate
180 days
BARC Tarapur
Refer Tender Documents
3 documents required · 3 mandatory
₹0
₹69,800
PD Office INRPC BARC Tarapur
3 May 2024
8 Jan 2024
13 Feb 2024
12 Jan 2024
12 Feb 2024
29 Jan 2024
12 Jan 2024 - 22 Jan 2024
23 Jan 2024
Amount
Refurbishment of 415 V LT Panels (3 Nos) of various Ratings as per Technical Specification and Annexures
Installation of SS Pipe inside Hume Pipe for interconnecting Transformer bay and soak pit including Butt joint and DPT test (SS Pipe of length 6 mtr each will be provided as FIM)
Single Phase Centrifugal pump of 1 HP rating, Head 5-15 M, Flow rate 15000-6000 LPH (minimum) with suitable DOL Starter panel (MOC: Double door Pregalvanised GI sheet steel) and complete accessories including suitable RRL hose pipe of lengh 30 metre (minimum) and Adapter/Coupler for connecting pipe to pump
Supply
Installation
Installation of Vertical Air termination of Length 1 Mtr 25 mm dia Copper rod with 5 Nos of spikes as per Technical specification and Drawing Note: The Lightning Arrestor shall be issued as FIM by the Department and Lightning Mast is of 7 Mtr height
Supply of 25 x 3 mm thick Copper strip with Tinning for mounting on parapet / surface of wall for Lightning Conductor for Horizontal Air termination including connection / terminating with nut, bolt, spring, washer etc as required
Laying of 25 x 3 mm thick Copper strip over Cable Tray and Jointing to be done by overlapping and with 2 sets of Brass nut bolt and spring washer spaced at 50 mm as per Technical specification and Drawing
90 Watt LED for Outdoor Lighting having housing of high pressure Die cast Aluminium, Lumen ≥ 10000, Efficacy > 110 lm/W, CRI ≥ 70, CCT - 5700 K, PF ≥ 0.95, THD < 10%, IP66 protection and Surge protection upto mimimum 4 KV
Supply
Installation
Supplying, stacking and laying of 230 mm thick rubble soling stones as under floor base including packing with smaller stone and compacting, ramming including spreading and consolidation of binding material, moorum etc. complete all as per specifications and as directed by the Engineer-in-Charge
Supply of 2 Volt 200 AH Tubular Gel VRLA Battery
Cutting and Removal of LT dead Cables of various sizes from Cable Trench (depth- 2.5 M) at site Substation. Dead Cables may be twisted at some location inside Trench
400 sqmm 3.5C
35 sqmm 3.5C
2.5 sqmm (Flexible)
Control Cable
Supply of Vacuum Interrupter with Silicone Embedding for 33 KV 1250 A HT Vacuum Circuit Breaker of type VY30M32H
Supply of RCC Hume pipe NP2 class of size 300 mm as per Technical specification
Installation of RCC Hume pipe NP2 class including Road cutting of suitable Width and Depth 1000 mm complete with RCC collars, Jointing with Cement mortar 1:2 ( 1 Cement : 2 Fine sand ) 100 mm thick encasing the pipe with concrete of 1:2:4 grade, backfilling and Concreting (1:2:4 ) with M30 grade Concrete
Supply and Making of Heat shrinkable Unpressurised cable Jointing kit TSF Type for jelly filled Copper Telephone cable of following sizes
0.5 Dia 10/20 pair
Supply
Installation
0.5 Dia 50 pair
Supply
Installation
0.5 Dia 100 pair
Supply
Installation
0.5 Dia 200/400 pair
Supply
Installation
9U wall mount network rack (600(Width) x 500 mm(Depth)) of 19" size side openable with minimum 2 cooling fans (90 cfm), 5 socket PDU, 2 cable manager and fully loaded with all accessories
Supply
Installation
28-port (24x1 Gbps RJ-45 Copper port, 4x1/10 Gbps SFP port) smart web-managed layer-2 network switch
Supply
Installtion
24-Port CAT6 patch panel of 1U size suitable for 19" rack fully loaded with all wiring support accessories
Supply
Installation
Fully Loaded drawout type, LC type 24-port Fiber Distribution (LIU) System of 1U size suitable for mounting in 19" rack
Supply
Installation
23 AWG CAT6 unarmoured UTP cable LSZH type
Supply
Installation
Indoor IP based 2MP vandal resistant (IK10) Dome IR camera (POE) along with mounting accessories
Supply
Installation
Outdoor IP based 4MP Motorised Focused Zoom (MFT) varifocal IR Bullet camera (POE) along with mounting accessories
Supply
Installation
32-Channel NVR with 1080p resolution support and H.265 or better decoding with minimum 20 TB Storage Capacity
Supply
Installation
10 TB HDD for CCTV Storage
Supply
Installation
2 Pair, 0.5 mm dia, Copper Conductor, Unarmoured Telephone Cable
Supply
Installation
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .