EE(E)/ELD-10/DDA
EE(E)/ELD-10/DDA,B2B, Janakpuri, ND-58.
Repairing, overhauling, servicing, and painting of the fire-fighting and fire alarm system at 273 (276) EWS houses, Manglapuri, Dwarka, including obtaining renewal of Fire NOC from Delhi Fire Services.
2026_DDA_894232_1
34/EE (E)/ELD-10/DDA/2025-26
Open Tender
Electrical Works
60 days
EE(E)/ELD-10/DDA
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹30,460
Yes
23 Jan 2026
16 Jan 2026
22 Jan 2026
16 Jan 2026
21 Jan 2026
16 Jan 2026
Overhauling checking, servicing, greasing of the Main fire Pump after necessary repairs/ relplacement of internal defective parts as required and re-testing & commissioning of the Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure minimum pressure of 3.5kg./sq.cm at highest and farthest outlet, at specified flow of 2280 LPM at 90m head conforming to IS :1520. the Job also includes putting the same in automatic operation mode of the Main pump set to make it functional as per Delhi Fire Service requirements complete as required.
Overhauling checking, servicing, greasing and refixing of the Jockey Pump after necessary repairs/ relplacement of internal defective parts as required and re-testing & commissioning of the Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 LPM at 90 m head conforming to IS: 1520 the Job also includes putting the same in automatic operation mode of the Main pump set to make it functional as per Delhi Fire Service requirements complete as required.
Overhauling checking, servicing, greasing and refixing of the Terrace Pump after necessary repairs/ relplacement of internal defective parts as required and re-testing & commissioning of the Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 450 LPM 35 mtr head squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class- F insulation conforming to IS: 325 the Job also includes putting the same in automatic operation mode of the Main pump set to make it functional as per Delhi Fire Service requirements complete as required.
Reconditioning, Overhauling, Checking, Servicing Diesel Engine i/c changing engine oil, lube oil/ lube oil filter, cleaning of fuel strainer & pre-filter, checking & servicing of fuel injector, flushing the radiator, cleaning of filter element, servicing of belt drives, inspecting & servicing of V-belt (2 Nos.), checking & adjusting valve clearance, setting of fuel pump timing etc., of Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure minimum pressure of 3.5kg./sq.cm at highest and farthest outlet, at specified flow of 2280 LPM at 90m head conforming to IS :1520. complete as reqd.
Reconditioning, overhauling, servicing, cleaning of existing installed Alarm Valve including repairs/replacement of internal defective parts, greasing, oiling, changing gasket etc. so as to make them in proper functional condition etc. complete as required as per site location.
Dismantling, removing, and reinstalling the existing Hose reel 30 mtr. long (20mm nominal) internal dia water hose thermo plastic(textile reinforced) type-2 as per IS: 12585 i/c providing the clamping etc., complete as reqd.
Supplying and Fixing of 4mm thick Glass in Fire Door of size upto 2.1 x 1.2 mtr. complete as required.
Providing, fixing, testing & commissioning of 15 mm dia quartzoid bulb type Pendent/Upright sprinklers of rating 68 degree centigrade with required accessories complete as required.
Reconditioning,overhauling,servicing,cleaning and welding including making proper connection of all existing wet riser, sprinkler and hydrant system consisting of different sizes butterfly/sluice valves/Non Return Valve/Strainer, hydrant valve, hosereel drum, air vessel, fire brigade connection, wet riser and hydrant piping etc. including repairs/replacement of internal defective parts,greasing,oiling so as to make them in proper functional condition etc complete as required as per site location and obtaining renewal of NOC from Delhi Fire Service.
Repair of the existing of 4 zone micro processor based intelligent addressable main fire alarm panel, including replacement of internal defective parts, re-wiring etc. providing glass of main door as required i/c re-testing & commissioning etc., complete as required & operating at 24 VDC comprising of audio & visual alarm indication of Fire, continuous status indications of Health/Fire/Faulty Zones, Fire/Fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. Silence alarm and a switch for resetting the whole system with audio-visual indications etc., as required.
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Repair of the existing repeater panel including replacement of internal defective parts, re-wiring etc. providing glass of main door as required i/c re-testing & commissioning etc., complete as required. operating at 24 VDC comprising of audio & visual alarm indication of Fire, continuous status indications of Health/Fire/ Faulty Zones, Fire/Fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. Silence alarm and a switch for resetting the whole system with audio-visual indications etc., as required. (Agni Panel)
Repair of the existing of 4 zone micro processor based intelligent addressable main fire alarm panel, including replacement of internal defective parts, re-wiring etc. providing glass of main door as required i/c re-testing & commissioning etc., complete as required & operating at 24 VDC comprising of audio & visual alarm indication of Fire, continuous status indications of Health/Fire/Faulty Zones, Fire/Fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. Silence alarm and a switch for resetting the whole system with audio-visual indications etc., as required. Make: Edward
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Make: Edward
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Repair of the existing repeater panel including replacement of internal defective parts, re-wiring etc. providing glass of main door as required i/c re-testing & commissioning etc., complete as required. operating at 24 VDC comprising of audio & visual alarm indication of Fire, continuous status indications of Health/Fire/ Faulty Zones, Fire/Fault test switches, zone isolation switch with indicators and also test switch for system test, sounder alarm. Silence alarm and a switch for resetting the whole system with audio-visual indications etc., as required. Make: Edward
Supply, Installation, Testing & commissioning of 24 V Power supply for repeater panel complete as required.
Supply, installation, testing & commissioning of 12V 7AH battery Acid maintence free Battery for repeater panel complete with cable terminals etc. including connections, inter-connections etc., as required.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
(a) Overhauling,servicing,cleaning, testing and commissioning of existing fire alarm system installed at DDA Housing complex maglapuri effecting necessary repairs / replacement of internal defective parts of addressable fire alarm system & devices re-testing & commissioning etc., complete as required, so as to make them in proper functional condition etc. as per CPWD specifications for fire alarm system and obtaining renewal of NOC from Delhi Fire Service. b) The job includes Restructuring, Re-programming & Re-addressing of existing "Edward" make intelligent addressable Addressable Fire Alarm System by Edward certified Engineer of consisting of existing devices viz optical smoke detector, Heat Detector, Multi Detector, Manual Call Point, Signal Module for input & output sounder with strobe, monitor module, control module etc., with software tools using latest applicable improvised version of the software complete as required.
Cleaning , denting and Painting of all equipments of fire fighting System installed at 273(276) EWS housing Manglapuri which includes MS Pipe of sizes i.e., 150mm, 100mm, 75mm, 63mm,50mm,40mm,32mm,and 25mm, fire hydrant boxes, hose cabinets, Fire shaft doors, fire fighting panel, motor, Pumps ,all supporting angles, brickets and clamps with minimum two coats of synthectic enamel paints of approved makes and manufacturing of required shade after proper cleaning the surface of all the above said installation etc complete as required at site.
Fabrication, Supply, and installation of a hut-shaped roof with central ridge, sloped sides, and adequate overhang for rain protection shed structure using plain galvanized iron sheet of size 8ft x 6ft fixed with self tapping screws and washers and mild steel L shaped angles of 40 mm x 40 mm x 5 mm, cut, welded and anchored to form the frame and trusses, supporting the structure & making boundary with 40 mm x 40 mm x 5 mm MS angle including covering this boundary with suitable sized and thick GI mesh wire including making suitable size of door with frame along with the locking arrangement. Painting and priming with anti-rust enamel paint on all steel members. Making hole in concrete and anchoring the MS angle to concrete base by making suitable size RCC foundation etc. complete as required. (suitable for 50 & 100 KVA DG Set) (i) 7.92 Mtr. x 5.18 Mtr. x 4.57 mtr
Supply, replacement , testing and commissioning of three phase MK1 type DOL starter suitable for three phase 5 HP ventillation fans i/c connection etc. complete as required at site.
Providing laying, testing & commissioning of 'C'class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (i) 150 mm
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (i) 150 mm
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.88 MB
Tendernotice_2.pdf
PDF • 2.52 MB
BOQ_939926.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid