Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹10.1 L+₹51,950 (5.43%)Rejected-Finance NO 16 TULASA NIWAS GANESH NAGAR SAMBRA BELAGAVI 591124 | BELAGAVI | BELAGAVI | KARNATAKA | 591124 | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹10.2 L+₹60,910 (6.37%)Rejected-Finance H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | L3 | Rejected-Finance Third lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Jan 2025, 6:00 pmClosed
GE AF Sambra
GE AF Sambra ATS Sambra Belgaum 591124
REPAIR / MAINTENANCE OF SEWAGE PUMP HOUSE, STP, SWIMMING POOL, DG SETS AND CONNECTED ITEMS AT AFS SAMBRA
2024_MES_686726_2
GE(AF)/SAM/TOK-39 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Sambra
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE AF Sambra
₹20,000
Yes
15 Mar 2025
3 Jan 2025
29 Jan 2025
3 Jan 2025
27 Jan 2025
15 Jan 2025
Amount
M&L for complete removal of existing treatment on FRP tank 150 ltrs capacity mounted on heavy duty MS fabricated frame and applying two coats of yellow synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
S&F in repairs Level Gauge for 150 Ltrs FRP Tank complete all as specified and as directed.
M&L for dismantling the dosing pump assy (Up to 1 HP) from dosing system after removing of nut, bolts etc and taking out the same to civil workshop/at site for repair/replacement of u/s parts and descalling of roller assembly , injection check valve , feed rate controler including replacement of suction & discharge tube & nut bolt , ferrule including servicing of pump assy etc refixing and testing etc all as directed by Engr-In-Charge.
S&F in repair agiator having SS sweep blade duly FRP coated in Chemical Dosing Sysyem complete all as specified and as directed.
S&F in repairs pressure gauge with isolating valve and siphon 0-7Kgf range with 40mm dia premium quality material body to withstand pressure rating as per site requirement complete all as directed by Engineer-In-Charge.
S&F in repair water tubing, Unplasticised PVC pipes, of pressure rating 10 kgf/cm2 laid on floors of 15mm bore complete all as specified and directed.
S&F in repair gun metal globe gate valve with iron wheel based screwed both ends for iron pipe complete of 15mm dia complete all as specified and as directed.
S&F in repair DOL (Direct on Line) Motor Starter for 0.75HP Motor set including Contactor, over load relay, & connected wiring complete all as specified and as directed.
M&L for angle, channels or tee sections, fixed independently, without connection plate, etc for (Fe 410 grade ) including necessary drilled holes, welded together complete all as specified and as directed.
S&F AVR of 7.5 to 40 KVA suitable for DG Set, including necessary connections with PVC insulated suitable size wire including removing the unserviceable AVR for complete all as specified and directed.
S&F AVR of 50 to 62.5 KVA suitable for DG Set, including necessary connections with PVC insulated suitable size wire including removing the unserviceable AVR for complete all as specified and directed.
S&F AVR of 75 to 160 KVA suitable for DG Set, including necessary connections with PVC insulated suitable size wire including removing the unserviceable AVR for complete all as specified and directed.
S&F Power contactor 4 pole 7.5 to 40 KVA, Type MCX 12 suitable for DG Set AMF panel, including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor for complete all as specified and directed.
M&L Power contactor 4 pole 50 to 62.5 KVA, Type MCX 22 suitable for DG Set AMF panel including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor comlete all as specified and directed.
M&L Power contactor 4 pole 75 to 160 KVA Type MCX 33 suitable for DG Set AMF panel, including necessary connections with PVC insulated suitable size wire including removing the unserviceable contactor complete all as specified and directed.
M&L for LT under ground XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade in trenches / passing through pipes of following cross-sectional area including taking out existing unserviceable cables of following sizes from its existing location complete all as specified and as directed:-
2 core, 10 sqmm
2 core, 16 sqmm
4 Core,16 Sqmm
4 core, 25 sqmm
3.5 core, 50 sqmm
S&F double walled corrugated HDPE Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler with rubber rings,pipe joint lubricant with all fittings as required at site complete all as specified and as directed
S&F double walled corrugated HDPE Pipe IS-16205, size outer dia 40 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler with rubber rings,pipe joint lubricant with all fittings as required at site complete all as specified and as directed
Excavation in trenches not exceeding 1.5m depth for laying cables and getting out in hard / dense soil for laying cable/erecting poles complete all as specified and directed
Returning and filling in soil including spreading leveling watering and well ramming in layers not exceeding 25cm complete all as specified and directed
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
S&F in replacement PVC insulated flat twin core sheathed cables standard aluminium conductor 1.1 KV grade of size 6 sqmm cable complete all as specified and directed
S&F in replacement PVC insulated flat twin core sheathed cables standard aluminium conductor 1.1 KV grade of size 10 sqmm cable complete all as specified and directed
S&F in replacement PVC insulated flat twin core sheathed cables standard aluminium conductor 1.1 KV grade of size 16 sqmm cable complete all as specified and directed
S&F in replacement Microprocessor based 2 loop capacity Network analogue addressable type with network card fire alarm control panel with min. 800 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 120 detectors and 120 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, Flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required and panels shall have provision of intigraton with BMS System. (UL/EN Approved) Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and as directed. Make Honeywell DX Notifire /Bosch Avenar8000 /Schneider ESMI
S&F in replacement addressable Manual call point (Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwriters laboratories listed, semi flush type complete all as specified and directed. Make: Honeywell/Bosch/Schneider
S&F in replacement addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as specified and directed. Make: Honeywell/Bosch/Schneider
S&F in replacement Analog addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC (Above Ceiling & below ceiling) complete all as specified and as directed.Make: Honeywell/Bosch/Schneider
S&F in replacement Conventional Beam detector complete as required for hall & indoor open area complete all as specified and directed. Make: Honeywell/Bosch/Schneider
S&F fault isolator module with automatic resetting arrangement complete all as specified and directed. Make: Honeywell/Bosch/Schneider
M&L for overhauling of Washer Heavy Duty of 50 kg Capacity Front Loading of make Fabcare including replacement of unserviceable parts complete all as specified & directed:- (Note:-Spare parts shall be measured & paid separately as 'Supply' under respective items here-in-after)
Supply only the following parts for heavy duty front loading washer complete all as directed:-
Door Glass Kit 25mm x 25mm of Washer Heavy Duty
Rivets Forward of Washer Heavy Duty
Timer of Washer Heavy Duty
Temperature Controlar of Washer Heavy Duty
Gland Door of Washer Heavy Duty
Heater 9KW of Washer Heavy Duty
Pressure Switch of Washer Heavy Duty
Water Inlet Valve of Washer Heavy Duty
Overhauling of Hydro extractor of 30 kg Capacity of make Fabcare including replacement of unserviceable parts complete all as specified & directed:- (Note:-Spare parts shall be measured & paid separately as 'Supply' under respective items here-in-after)
Supply only the following parts for Hydro extractor complete all as directed:-
Timer of Hydro Extractor
Single Phase Preventer of Hydro Extractor
Spring of Hydro Extractor
Rubber Buffer of Hydro Extractor
MCB 4P 40 amps of Hydro Extractor
Overhauling of Drying tumbler of 30 kg Capacity of make Fabcare including replacement of unserviceable parts complete all as specified & directed:- (Note:-Spare parts shall be measured & paid separately as 'Supply' under respective items here-in-after)
Supply only the following parts for Drying tumbler complete all as directed:-
Door Glass Kit 30mm x30mm of Drying Tumbler
Heater Luping of Drying Tumbler
Teflon Wire 10 mm of Drying Tumbler
Grease of Drying Tumbler
Supply & laying PVC FRLS armored cable 1.5sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct/ along pole/wall etc including making connection complete and making good the disturbed surface matching with existing surface complete all as specified and directed. (Note: the cost of Al thimbles/lugs and cable gland etc is inci in quoted rate and no extra payment will be made for it).
S&F in replacement remote Response indicator for ceiling detectors & Cabin Detectors complete all as specified and directed. Make: Honeywell/Bosch/Schneider
S&F in replacement programming User Interface based network panels having capable of each fault and plan representing each facility being monitored with nominclature depicting the actual locations of the various systems; and/or sensors locations. The User Interface shall be located in monitor room in one of the blocks on panel.
PURVIK CONSTRUCTIONS (BID ID -3224532)
DHAIRYASIL RAMAKANT DESAI (BID ID -3219716)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .