| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC B 248 BASEMENT BLOCK B CHITTARANJAN PARK NEW DELHI 110019 11 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | L1 | Accepted-AOC Work order Issued | |
| 2 | L2₹2.0 L+₹34,000 (20.0%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹2.3 L+₹57,000 (33.5%)Rejected-Finance 3C 3RD FLOOR BALA PRASAD TOWER DIAGONAL ROAD BISTUPUR JAMSHEDPUR EAST SINGHBHUM JHARKHAND 831001 | EAST SINGHBUM | JHARKHAND | 831001 | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹2.4 L+₹70,000 (41.2%)Rejected-Finance | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹2.8 L+₹1.1 L (62.4%)Rejected-Finance GROUND FLOOR 72 BUSINESS PARK CROSS ROAD C MAROL INDUSTRIAL AREA MIDC ANDHERI EAST MUMBAI MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
3 Jul 2024, 4:00 pmClosed
AE
NRS Hospital Sub Division
STRUCTURAL HEALTH ASSESSMENT OF Dr B C Roy LECTURE THEATRE BY NDT TESTING AND VISUAL SURVEY REPORT PREPARATION AND BOQ FOR RESTORATION WORK OF Dr B C Roy LECTURE THEATRE NRS MEDICAL COLLEGE and HOSPITAL
2024_WBPWD_692495_1
. WBPWD/AE/NRSH/NIeQ-02/2024-25
Open Tender
CIVIL WORKS
Item Rate
30 days
NRS Medical College and Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Yes
2 Jan 2025
12 Jun 2024
5 Jul 2024
12 Jun 2024
3 Jul 2024
14 Jun 2024
Amount
Visual Survey: Visual inspection for surface damages, damage classification. The visual inspection shall largely cover areas of high distress, corrosion, moisture, leakage, abnormal variations in structure, algae and fungus growth, efflorescence, etc. Visual inspection would be documented in the form of worksheets, photographic records, and distress over drawings. Simple tools and instruments like camera with flash light, magnifying glass, binoculars, chisel and hammer, etc shall be used for measuring the distresses as per site requirement.
Report submission with Test Results Interpretation: Preparing and submitting comprehensive report consisting of findings from visual inspection, test data, interpretation of results, conclusions and final recommendations along with sketch indicating the location of the test. Report does not include the repair scheme/DPR or BOQ related to the project.
Repairing Methodology and retrofitting scheme: For structural serviceability and safety, periodic maintenance scheme, futuristic protection of structure including comment on the stability of the roof. The recommendation for structural repair and rehabilitation to the structures shall have detailed technical specifications, materials to be used and design details, vulnerability indices and order of urgency to repair.
DPR and BOQ: Agency shall prepare and submit the DPR in 2 copies which include all diagnosis results (if any), interpretations, conclusion, site photographs, BOQ and conceptual scheme for Rehabilitation/ retrofitting works (feasible and economic options) with Rate analysis, material specification, execution drawing for strengthening of structure along with technical Specifications and periodic inspection and maintenance manual.
UT Thickness for Steel Section Size Assessment: Thickness of a solid/hollow element is measured by UT gauged which is principled on the time taken by the ultrasound wave to return to the surface as per ASTM E797 / E797M. It is useful in section detailing of steel members and it ascertains the section loss due to ongoing corrosion in all types of steel elements. It is used to cross verify the elements whether same drawing section drawings were followed during construction or not.
Ration percentage of Binding Mortar/plaster by chemical test:- Binding material (mortar) or surface plaster properties to be evaluated for determination of percentage of constituent elements (sand:cement or Lime: Surkhi or other binding particle percentage), composition details of plaster/ binding mortar, estimated compressive strength of bindingmaterials, fineness of mortar and grade or type of binding mortar/surface plaster following IS 1905.
Brick/Masonry unit compressive Strength: To check the compressive strength of burnt brick/other masonry unit (like stone/ACC block/brick tiles etc.) as per IS 3495 :1992 part I, IS 1077 : 1992 and knowing the Water Absorption capacity of brick as per IS 1077: 1992, IS 3495 :1992 part 2
Radiographic Inspection Services
MANUPAMA TECHNOLOGIES PVT.LTD
SRK Infratech Pvt.Ltd.
Bureau Veritas (India) Pvt Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .