| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L1 | Accepted-AOC LOWEST QUOTED AMOUNT | |
| 2 | L2₹4.9 L+₹63,064 (14.7%)Rejected-Finance SANJAYPALLY CANNING SOUTH 24 PARGANAS 743329 | CANNING | SOUTH 24 PARGANAS | WEST BENGAL | 743329 | L2 | Rejected-Finance bid is not L1 | |
| 3 | L3₹5.0 L+₹70,359 (16.4%)Rejected-Finance 2 SURI LANE GROUND FLOOR KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹12,275
Closing Date
17 Jan 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Jhargram Electrical Div.,PWDte
GOVERNMENT OF WEST BENGAL OFFICE OF THE EXECUTIVE ENGINEER JHARGRAM ELECTRICAL DIVISION, P.W.Dte. Jamboni More, Dist. Jhargram, Pin- 721507
Construction of four storied building at Jhargram in the District of jhargram Emmergent EI works for Source Cable
2021_WBPWD_356695_2
WBPWD/EE/JED/eNIQ27/2021-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
JHARGRAM
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,275
16 Mar 2022
10 Jan 2022
19 Jan 2022
10 Jan 2022
17 Jan 2022
10 Jan 2022
120 days
Amount
Supply and delivery of the following cable:-
1.1 KV 4 core 185 sqmm Aluminium armoured cable. ( Polycab/ Glosdter/ Havells) [ Meter room TO Panel ]
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
100x50x1.25mm (18SWG)
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying only Cable of 185 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 core 185 smm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 core 185 smm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supply & Fixing of 12 mm Hylem Sheet ( 24 inchx30inch ) with necessary fixing arrangement on wall with MS fastner arrangement grouting on wall with necessary supply & fixing 415 v 200 Amp porcelain make rewitrable type Fuse Unit---3 no with one Neutral link porcelain make, with extention strip ( Havells make) cat no. with fixed on ply wood with necessary arrangement.
Supplying and fixing 32A,240V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall.(make-Standard/Havells)
Supplying and fixing 415V, 415A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(make- Siemens/L&T/Havells)
S&F of fully diffused recessed mounted 2'X2' LED Suitable for indoor spaces.(make-Philips,cat no-RC380B LED36S-6500 G5 L60 W60 PSD OD OC/ RC380B LED36S-6500 G5 L60W60 PSD OD or Euivalent CG as per direction of EIC.)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making arthing attachment, painting and mending good damages to building works.(on Board)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe
PARBATI INFRATECH
MAHESWAR ELECTRICAL INDUSTRIES
stage.html
html • 0.05 MB
technical_695359.pdf
PDF • 0.26 MB
techsummary_695359.pdf
PDF • 0.14 MB
finance_695359.pdf
PDF • 0.26 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_695359.pdf
PDF • 0.14 MB
AOCeniq27.pdf
PDF • 0.30 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .