Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹32.0 L+₹5.6 L (21.0%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹33.0 L+₹6.6 L (25.0%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹34.4 L+₹8.0 L (30.1%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹36.8 L+₹10.3 L (39.0%)Rejected-Finance NO 99 IE DG INDUSTRIAL ESTATE DOLLYUNJ POST BOX NO 554 JUNGLIGHAT POST SRI VIJAYA PURAM 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
30 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
CERTAIN REPAIRS TO SERVICE DUCTS AND RELATED WORKS AT IN JETTY UNDER AGE E/M AT GE HADDO, PORT BLAIR
2020_MES_380561_1
8492/GE/H/PB
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Port Blair
D b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹84,000
Yes
5 Dec 2020
24 Sept 2020
3 Nov 2020
24 Sept 2020
30 Oct 2020
19 Oct 2020
24 Sept 2020 - 1 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. NOTE: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 m but not exceeding 3.0 m, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. NOTE: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for poles/stays/feeder pillar boxes etc., complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings of poles/stays including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Lifting RCC cover slabs of size 2 to 4 metres long, 1 to 2 metres width and upto 300 mm thick and about 2.5 to 4.0 tons in weight lying on jetty (as required at suitable intervals all along the jetty) by cutting/chipping the clearance groove all around, stacking aside carefully using suitable lifting machinery/crane without causing any damage to the existing structure, carrying out cleaning of cable duct of size 2 to 4 metres in width and 1.0 metre depth, lifting and placing the cables aside, any numbers of size 3½ core x 240 to 500 Sqmm or taking slightly above the duct with and including cost of minor tools etc., pumping out the stagnated water from the duct, removing all mud/sludge and clean the entire duct, cleaning the cables and placing back in position side by side or on supporting angles and replacing the RCC cover slabs back in position over the duct at Naval wharf and pointing the joints with CM (1:2) and removing the rubbish from site to outside MD land complete all as specified and as directed. NOTE: Cover slabs at suitable intervals only need to be lifted to facilitate cleaning of jetty duct and removal of unserviceable trash lying inside the jetty duct such as cables, pipes etc., and removal/pumping out of mud and stagnated water. Each cover slab lifted shall be measured and paid as ONE UNIT (JOB) whereas cleaning of duct shall be for full length of jetty complete. The tenderer shall make note of this requirement and no claim whatsoever shall be entertained at a later stage.
Lifting of RCC cover slabs, each of size 2.0m x 1.0m (approx) and of 150mm thickness (approx) and about 0.2 to 0.6 tons in weight from position lying over cable duct or cable trench by cutting/chipping the clearance groove all around the slab, without causing any damage to the existing structure, keeping aside, carrying out cleaning of duct and laying of cables with and including cost of minor tools etc., and replacing the covers back in existing position over duct after completion of work and pointing the joints in CM (1:2) complete all as specified and as directed. NOTE: Each cover slab lifted shall be measured and paid as ONE UNIT.
Disconnecting old serviceable HT/LT UG cables of size 3 core / 3½ core, 95 to 500 Sqmm from its connections, drawing out from the pipe underneath jetty slab from power house to jetty, jetty to cope box points, checking the cable for faults with megger, rectifying the faults, if any by using cable joints and re-using the serviceable cable in the same location by drawing through pipes fixed with suitable clamps/saddles and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed. NOTE: Removal of jetty slab covers and replacing back in position shall be measured and paid separately under relevant item of this BOQ.
Disconnecting old unserviceable HT/LT UG cables of size 3 core / 3½ core, 95 to 500 Sqmm from its connections, drawing out from the pipe underneath jetty slab from power house to jetty, jetty to cope box points, checking the cable for faults with megger and removing the same from site complete all as specified and as directed. NOTES: (a) Removal of jetty slab covers and replacing back in position shall be measured and paid separately under relevant item of this BOQ. (b) The old unserviceable cable shall become contractor's property against Schedule of Credit.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 300 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 400 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 500 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed. NOTE for all items of cable: 1. Cable test results like continuity test, megger test shall be submitted to Engr-in-charge before the cable is laid. 2. Necessary excavation and earth work shall be measured and paid separately under relevant items of this schedule.
M&L for removing carefully existing cables, earth strips/wires of any type from existing damaged cable trays of any size, type and from any location etc., and supply and fix new hot dip galvanized iron perforated cable trays of size 250mm wide x 50mm high, made of 2 mm thick GI sheet, vertically/horizontally on walls/ buildings/ floors/ roofs etc., including fixing them with necessary fasteners / nuts and bolts, coupler plates and all connected accessories as per site requirement, replacing and securing the existing cables, earth strips/wires back in position on new cable trays complete all as specified and as directed. MAKE: MANIBHADRA ELECTRICALS PVT. LTD. or equivalent reputed make as approved by the GE.
M&L for removing carefully existing cables, earth strips/wires of any type from existing damaged cable trays of any size, type and from any location etc., and supply and fix new hot dip galvanized iron perforated cable trays of size 100mm wide x 50mm high, made of 2 mm thick GI sheet, vertically/horizontally on walls/ buildings/ floors/ roofs etc., including fixing them with necessary fasteners / nuts and bolts, coupler plates and all connected accessories as per site requirement, replacing and securing the existing cables, earth strips/wires back in position on new cable trays complete all as specified and as directed. MAKE: MANIBHADRA ELECTRICALS PVT. LTD. or equivalent reputed make as approved by the GE.
M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including bolts, nuts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including dismantling old unserviceable steel sections complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for de-carbonising/ cleaning of entire LT panel boards/ pillar boxes of 415/380/230 Volts, 3 phase bus bar chamber and electrical connections after removing the bus bar from the bus bar chamber, cleaning with CTC and ensure proper de-carbonizing including new bakelite insulators of adaquate size wherever required, re-fixing the same after applying Becktrol (Red) solution to the spout, checking all the connections, tightening back in position using new bolts, nuts, washers and thimbles for incoming and outgoing system complete all as specified and as directed.
M&L for mild steel chequered plates conforming to Fe-410-W (Gde-E-250) Quality 'A', of any thickness by cutting/ making into required shape, providing necessary angular supports and handles with 6 mm dia rod as per the site conditions by welding etc., including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and laid over cable trenches of various substations including dismantling old unserviceable ones complete all as specified and as directed.
Supply, laying, testing and commissioning DI (ductile iron) pipes 200mm dia, Class K-9, flanged at both ends with internal cement mortar lining and external zinc coating (minimum 130 Grams/Sqm) and bitumen finishing layer (minimum 70 micron thickness), conforming to IS- 8329:2000 (Amended No. 1) in any length alongwith jointing materials such as rubber gasket, laid in same trench or on masonry pillar supports after and including taking out old unserviceable CI/DI water pipes with fittings and recovering lead joints by burning complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM / JINDAL NOTE: (i) DI specials will be measured and paid separately under relevant items of this BOQ. (ii) Excavation & earth work will be measured and paid separately under relevant items of this BOQ.
Supply, laying, testing and commissioning DI (ductile iron) pipes 250mm dia, Class K-7, spigot and socketed ends with internal cement mortar lining and external zinc coating (minimum 130 Grams/Sqm) and bitumen finishing layer (minimum 70 micron thickness), conforming to IS- 8329:2000 (Amended No. 1) in any length alongwith jointing materials such as rubber tyton joints, , laid in same trench or on masonry pillar supports after and including taking out old unserviceable CI/DI water pipes with fittings and recovering lead joints by burning complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM / JINDAL NOTE: (i) DI specials will be measured and paid separately under relevant items of this BOQ. (ii) Excavation & earth work will be measured and paid separately under relevant items of this BOQ.
Supply, laying, testing and commissioning DI (ductile iron) pipes 100mm dia, Class K-7, spigot and socketed ends with internal cement mortar lining and external zinc coating (minimum 130 Grams/Sqm) and bitumen finishing layer (minimum 70 micron thickness), conforming to IS- 8329:2000 (Amended No. 1) in any length alongwith jointing materials such as rubber tyton joints, laid in same trench or on masonry pillar supports after and including taking out old unserviceable CI/DI water pipes with fittings and recovering lead joints by burning complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM / JINDAL NOTE: (i) DI specials will be measured and paid separately under relevant items of this BOQ. (ii) Excavation & earth work will be measured and paid separately under relevant items of this BOQ.
M&L for Cast iron fittings (specials) such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing of double socket etc), Tee pieces, single branch, Y-junction, double branch, tail piece, cross (all sockets or spigot and socketed ends), collars, caps and plugs up to 150mm dia or bore of pipe complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM/ JINDAL
M&L for Cast iron fittings (specials) such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing of double socket etc), Tee pieces, single branch, Y-junction, double branch, tail piece, cross (all sockets or spigot and socketed ends), collars, caps and plugs from 200 to 250mm dia or bore of pipe complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM/ JINDAL
S&F Galvanised iron strip 32x6mm buried in ground or fixed to walls/poles with necessary clamps, bolts and nuts including taking down old unserviceable strip complete all as specified and as directed.
M&L for preparation of old painted surfaces of LT panels/ feeder pillar boxes by cleaning/rubbing with coarse cloth/ wire brushes to remove dust deposits, oil, grease, levelling the undulations using oil putty and painting by applying one spray coat of synthetic enamel paint of existing tint without disturbing/ damaging the electrical net work system/ equipment including marking the details such as capacity/ rating/ incoming/ outgoing/ Danger notice board in capital English alphabets with red colour radium sticker of required size complete all as specified and as directed.
M&L for Precast RCC pole (1:2:4) type B1, 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom, Class 9 with two coats of cement based paint including taking down old unserviceable pole complete all as specified and directed. MAKE: Conformed to ISI (or) Approved by Andaman Electricity Department
S&F Air circuit breaker of capacity 2000A, 50KA, 440 Volts, AC, 4 pole, manually draw out, electrically operated with microprocessor based tripping sysytem against short circuit, instantaneous and earth fault protection along with motor mechanism, closing coil, shunt release and instantaneous under voltage release pre trip alarm and indvidual fault LED indications complete all as specified and as directed. MAKE: L&T Cat part No.SL96066 or equivalent in SCHNEIDER/SIEMENS/ABB. NOTE: Cost includes necessary fabrication and modification to Panels and bus bars for fixing ACB as per site requirement.
Fabricate, supply, install, test and commissioning of cope box of size 0.9mx0.9m and 1.0m height made out of 50x50x6mm angle iron frame covered with 6mm thick aluminium sheet all over fixed with stainless steel bolts, nuts and washers, provision for bottom cable entry, top opening hinged lid with handle and two side canopy with cable entry 06 Nos and copper bus bars of 2000 Amps capacity and with cable entry 03 Nos and copper bus bars of 800 Amps capacity and bakelite sheet of 20 mm thick, 80 cm (2x40cm) long as separators of bus bars, cope box mounted over existing RCC jetty slab by making necessary cutting, chipping and making good the disturbed surfaces and finally connecting to existing cables including taking out old unserviceable cope box complete all as specified and directed.
CHANDER SEKER ENTERPRISE
SRI HARSHITA ELECTRICALS
Sree Tirumala Enterprises
SMS Engineering Corporation
BHARAT MULTITECH INDUSTRIES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .