| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC G 5 2 1 PANCHADEEP CO OP HSG SOCIETY SECTOR 29 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹48.1 L+₹32,151 (0.67%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹50.3 L+₹2.6 L (5.39%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹52.2 L+₹4.4 L (9.31%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹53.0 L+₹5.3 L (11.0%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
10 Nov 2023, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
REPAIRS TO SUNKEN FLOOR, LEAKAGE/SEEPAGE, AT SPDC, NSD, WED AND DSRV AND REPAIRS TO FOOTPATH, CHAIN LINK FENCING, ETC AT SPDC, NSD AND REPAIRS TO ROLLING SHUTTERS, ROOF SHEETS, CEILING, VALLEY GUTTERS AT WED, SAW MILL AND NSD UNDER GE (NW) MANKHURD
2023_MES_623786_1
8263/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹95,000
5 Dec 2023
18 Oct 2023
11 Nov 2023
18 Oct 2023
10 Nov 2023
24 Oct 2023
Amount
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc and removing debris outside MD land complete all as specified
Taking down rolling shutters n.exc 10 Sqm each and refixing to its original position after cleaning all parts, straightening rails, changing damaged strips, bottom rail, guide rail, helical spring, worm gear, lock plate etc as required including scaffolding and other safety measurements Note: lath strips, bottom rail, spring, gears etc will be measured and paid separately
Taking down rolling shutters exc 10 sqm and n.exc 15 sqm each and refixing to its original position after cleaning all parts, straightening rails, changing damaged strips, bottom rail, guide rail, helical spring, worm gear, lock plate etc as required including scaffolding and other safety measurements Note: lath strips, bottom rail, spring, gears etc will be measured and paid separately
Taking down rolling shutters exc 15 sqm and refixing to its original position after cleaning all parts,changing damaged strips, straightening rails, bottom rail, guide rail, helical spring, worm gear, lock plate etc as required including scaffolding and other safety measurements Note: lath strips, bottom rail, spring, gears etc will be measured and paid separately
Taking down gear box from existing position and repairing the gear shaft and provn of new gear box in position complete all as specified and directed
M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified
M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on old surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 16 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on old surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the old surfaces of existing exterior walls, parapet walls, chajjas, soffit of beams, columns etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Notes (i) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for providing CRS TMT bars any dia in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members, complete all as specified and directed.
Demolition of brick/cement concrete (unreinforced) of any description and in any position not other wise specially provided for complete and removing the retrieved debris out side MD land, all as specified and directed
Demolition of brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removing debris outside MD land
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MD land, complete all as specified and directed.
Dismatling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings as specified
Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc to a distance exceeding 500m and not exceeding 1.0km complete all as specified and directed by the Engineer-in-charge
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in leveling course over RCC roof/ terrace surfaces to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC(water proofing compound) as per manufacturer's instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately as "supply only".
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in hold fast, bed plate etc including necessary form work complete all as specified and as directed.
M&L for 75mm thick Cement concrete type C- 2, 1:3:6 (40mm graded aggregate)
M&L for providing PCC 1:4:8 type D2 (using 40mm graded aggregate) as sub base 75mm thick complete all as specified and directed.
i) M&L for preparation of surface including cleaning of all dirts and provide the following water proofing treatment in Accessible Roof/Inaccessible Roof & terrace, narrow width over the roof gutter of store houses or chajjas etc. ii) Apply oil bound bitumen primer @ 0.25 gm/Sqm manufacturer by the same agency as that of APP with density of 0.87-0-89 Kg litr at 25 c on the prepared dry roof surface provide and lay APP modified water proofing membrance reinforced with non wooven polyster matt with physical properties as under :- (aa) Membrane Weight - not less than 3.0 Kg/Sqm (ab) Non woven polyster weight - 160 gm /Sqm (ac) Joint Tensile strength Longiutinal - 650 N/Sqcm Tranverseand longitudnal - 350/Sqcm (ad) Tear strength Longiutinal - 300N /cm Tranverse - 250N/cm Direction (ae) Impermeability underwater pressure 2Kgf/Sqcm (iii) APP membrane shall be laid using butaretorch by Torch on application with minimum 10cm side overlap and 15cm end lap. The laying of membrance shall be got, done through an authroiset applicate of Manufacture of membrane. (iv) Over the membrane provide a finishing with solar reflective bitumen aluminium to inaccesible roof. paint @ 0.10 Kg/Sqm as prescribed by manufacturer
M & L for preparation of existing surface by cleaning, removing of loose material and filling cracks with polymer modified mortar using Epoxy mortar, and applying Smartcare PU Magnum or equivalent is a polyurethane elastomeric waterproofing liquid membrane which offer superior mechincal, chemical, thermal, UV & weather resistant properties,as it is based on pure, elastomeric , hydrophobioc polyurethane coatings at a coverage of 1.6kg per sqmt in 2 coats, of make - ASIAN/ SIKA/ STP/FOSROC or equivalent
Supply and Application of 5 Layer SHR Waterproofing Coating System on leaking concrete surface by thorough surface preparation followed by one absorption coat of Thermacool WP 51, nano-tech modified, UV resistant elastomeric clear coat having min. 50% solids, then overcoating with 2 Coats of Thermacool WP51 + Cement mixture as waterproofing coat having +450% Elongation, Tensile Strength min. 2.2 MPa and then top-coated with 2 Coats of Thermacool 0.3C pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) Solar IR Heat Reflective coating conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 sqm/Ltr/2 coat, DFT 100 - 120 microns using brush, roller, airless spray gun as applicable. The product should have been tested at IIT or NABL Approved Lab and application is to be done by Thermacool approved applicator only
Supply only Integral waterproofing compound.
S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
M&L for fixing 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. Fixed with L-type or J-type or cranked hook bolts as specified and directed
M&L Asbestos cement one piece plain angular ridge 6mm thick Fixed with L-type or J type or cranked hook bolts as specified and directed
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs complete all as specified and directed by EIC.
M&L Vitrified Coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs complete all as specified and directed by EIC.
Glazed ceramic coloured tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match (dado) including 10 mm thick back coat of cement plaster on fair faces of brick work 1:3
M&L for coloured Parking tiles, heavy duty of size 300x300x10 mm thick, set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the colour of the tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed. Make : JOHNS0N /SOMANI/ORIENT BELL/KAJARIA.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion, as per requirement, complete all as specified and directed.
M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages : Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid . (ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls all complete all as specified and directed.
S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal with access door
S&F 110mm bore PVC (SWR) bend with access door
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white with integral foot rests with flush pipe of 32mm dia including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with flush pipe of 32mm dia including necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
S&F vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia pillar tap, CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.in repair
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm and Supply & fixing 15 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Unplasticised PVC pipes of 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
S&F in repairs 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, of suitable length as per site requirement connecting to WC etc, and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
S&F in repairs CP stop cock 15mm bore fancy type chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP pillar taps 15mm bore, cast copper alloy, chromium plated fancy type complete all as specified and directed.
S&F in repairs waste fitting of 32 mm bore brass, chromium plated for glazed ware wash basin etc complete all as specified and directed.
S&F in repairs waste fitting of 40 mm bore brass , chromium plated for glazed ware for sink coulpling etc complete all as specified and directed.
S&F in repairs waste pipe for WHB 32mm bore fixed to wash hand basin coupling length pipe 0.90 mtrs each complete all as specified and directed.
S&F in repairs waste pipe for kitchen sink 40mm bore fixed to sinks coupling length pipe 0.90 mtrs each complete all as specified and directed.
S&F in repairs stainless steel grating in round shape 100mm dia complete all as specified and directed.
S&F in repairs stainless steel grating in round shape 100mm dia with one hole for waste pipe complete all as specified and directed.
Supply only plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete all as specified and directed..
S&F GI Tubes 15mm bore, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
S&F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
S&F in repair chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
S&F in repairs Health faucet with 1 mtr tube & hook complete all as specified and directed.
S&F in repairs two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
M&L for Machine pressed precast concrete interlocking 60mm thick precast cement grade M-35 with grey cement and pigment having compresive strength 35 N/mm2 laid with over and including sand cushinig of average thickness 25mm after consolitation set and level the tiles on proper level with interlocking complete all as specified and directed.
Dismantling fencing wire mesh, any type
Supply only Chain link MS galvanisd fencing, any size or type
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
M&L for plane cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in foundations/post holes.
S & f Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240
M&L applying 2 coats of synthetic enamel paint over a coat of red oxide on new steel surfaces over 10 cm width or girth including preparation of surface complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L broken stone or boulders hardcore of gauge n.exc 63mm, deposited, spread and levelled and well rammed in layers n exc. 15 cm thick, watered and rammed to a true surface.
S&F for 300mm dia reinforcement concrete pipes, class NP 3, laid and jointed complete with collars.
M & L Brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed
S & F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E 165
Cleaning, greasing, oiling and servicing for smooth functioning of all parts of rolling shutters of any size including gear box etc as required including scaffolding and other safety measurements complete all as specified and directed
Supply only mild steel spring made out of 6 mm to 11 mm dia high tension steel wire conforming to IS 4454 having 65 to 100 helical for rolling shutter for smooth working complete all as specified and directed (dia of spring 100 mm to 150 mm) complete all as specified and directed
Supply only worm gear made out of mild steel suitable for rolling shutter mentioned here-in-before
Supply only MS 75mm wide lath strips 1mm thick for rolling shutter including mild steel clips at either ends duly painted with two coats of synthetic enamel paint (shades to match with the existing) over a shop coat of red oxide primer complete all as specified and directed.
Supply only MS 75mm wide lath strips aluminium double wall type from 1.6mm thick aluminium corrugated profile slats with bottom profile of alluminium with bottom rubber sealing side guide of aluminium profile with rubber insert on both ends complete all as specified and directed.
Supply only mild steel bottom rail with lock plate and two handles 150 mm wide and 3 mm thick including necessary locking arrangement on both sides and painting to bottom rail with and including two coats of synthetic enamel paint to match with existing over a shop coat of red oxide primer complete all as specified and directed
Supply only guide rail 3 mm thick suitable for rolling shutter complete alla s specified and directed including holdfast, block concrete and making good complete all as specified and directed
Replacement of existing unserviceable gear box with new gear box made out of 1mm thick mild steel sheet including painting with two coats of synthetic enamel paint over a coat of red oxide primer, size of gear box 15cm x 15cm x 15cm complete all as specified and directed.
S & F in repair ball bearing for rolling shutters complete all as specified and directed
S&F Steel rolling shutters, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete:gear operated type with bevel gear box and crank handle
M&L preperation of new surfaces and applying two coats of synthetic enamel paint over a coat of red oxide to steel Surfaces of any description over 10cm grith or width, not otherwise described
M&L preperation of old painted surfaces and applying one coats of synthetic enamel paint over a coat of red oxide to steel Surfaces of any description over 10cm grith or width, not otherwise described
M&L preperation of old surfaces and applying one coats of aluminium paint over a coat of aluminium red oxide to steel Surfaces of any description over 10cm grith or width, not otherwise described
M&L preperation of old surfaces and applying two coats of aluminium paint over a coat of aluminium red oxide to steel Surfaces of any description over 10cm grith or width, not otherwise described
M&L for dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F Anodised aluminium snap grid frame work for false ceiling all as specified fixed using Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions
S&F 1.0mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with welded or soldered joints.
S&F for polycarbonate plain sheet twin wall section with thickness not less than 5mm fixed in aluminium frames including necessary fixing arrangement all as specified and directed. Note : Aluminium frame shall be measured and paid separately
S&F in repairs Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. Note : A sum of Rs 28,980.00 towards sch of credit shall be deducted to arrive the contract sum.
mp construction co
Joy builders
Parmatma Enterprises
AM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .